Search PubMed⌕ Search

Biomedical subjects

F E Boada

Publications and source records attributed to F E Boada.

21 records · Page 2Linked to original sources

Spectrally weighted twisted projection imaging: reducing T2 signal attenuation effects in fast three-dimensional sodium imaging.

A scheme for the reduction of T2 signal attenuation effects in three-dimensional twisted projection imaging is presented. By purposely reducing the sample density at the high spatial frequencies, a considerable reduction in readout time is achieved. The reduction in readout time leads to decreased T2 signal attenuation which translates into improved signal-to-noise ratio (SNR). The SNR improvement is achieved without decreasing the image's resolution since the point spread function depends on the sample weighting as well as the T2 attenuation. The results indicate that SNR improvements of up to 40% can be achieved using the proposed scheme.

Brain↗

Quantitative tissue sodium concentration mapping of normal rat brain.

A quantitative in vivo method for obtaining maps of tissue sodium concentration (TSC) by MRI is compared to the invasive, global 22Na radionuclide dilutional technique in the normal rat brain. The MR method uses a three-dimensional projectional acquisition scheme to minimize signal losses from transverse relaxation. Internal calibration standards are used to convert the signal intensity into TSC after correction for B1 inhomogeneities by using the ratio of 23Na and 1H images obtained with identical B1 distributions and sensitivities at the two frequencies. Over the biological range of concentrations, the TSC, measured as the ratio of MR signals of 23Na and 1H, gives a linear response with concentration. In the normal rat brain, the mean TSC measured using the MRI method (TSC = 45 +/- 4 mM, animals = 5) is not significantly different from the global 22Na radionuclide method (TSC = 49 +/- 6 mM, animals = 7).

Animals↗

Quantitative in vivo tissue sodium concentration maps: the effects of biexponential relaxation.

The biexponential relaxation behavior of the sodium nucleus affects the accuracy of quantitative measurement of in vivo tissue sodium concentration (TSC). Theoretical analysis and in vivo experimental results are used to demonstrate the extent of the large bias in the measured TSC that arises when the relaxation behavior in vivo differs significantly from that of the calibration standards which is when a significant fraction of the total sodium signal decays with a relaxation time much shorter than the echo time (TE) used for imaging. This bias can be as large as 20% for measurements of TSC in a normal rat brain with TE = 2 ms. Our findings indicate that shortening the echo time (TE < 0.5 ms) by projection imaging is a reliable means of obtaining accurate in vivo estimates for TSC using MR.

Animals↗