Endothelin and cardiac arrhythmias: do endothelin antagonists have a therapeutic potential as antiarrhythmic drugs?

Endothelin-1 (ET-1), the predominant isoform of the ET peptide family and a potent vasoconstrictor, has been shown to aggravate ischemia-induced ventricular arrhythmias. However, there is also evidence that ET-1 may have a direct arrhythmogenic action that is not solely attributable to myocardial ischemia. Proposed mechanisms for the arrhythmogenic effects of ET-1 are prolongation or increased dispersion of monophasic action potential duration, QT prolongation, development of early afterdepolarizations, acidosis, and augmentation of cellular injury. As for an ionic basis for the observed electrophysiologic effects, ET-induced Ca(2+) release from intracellular stores, generation of inositol triphosphate, inhibition of delayed rectifier K(+) current, and stimulation of the Na(+)/H(+) exchanger may be involved. Recently, some studies have shown that ET receptor antagonists, which promise to be powerful tools in cardiovascular medicine, may also demonstrate antiarrhythmic properties. This review describes the current state of knowledge on the interactions between the ET system and cardiac arrhythmias, and discusses the therapeutic potential of ET antagonists as antiarrhythmic drugs.

Action Potentials↗

Sudden cardiac death after coronary artery bypass grafting is not predicted by signal-averaged ECG.

BACKGROUND: Sudden cardiac death (SCD) is a major cause of death despite successful revascularization in patients with coronary artery disease. The signal-averaged ECG (SAECG) is a sensitive predictor of SCD and could be used in the screening strategy to select patients for prophylactic cardioverter implantation. METHODS: The SAECG was recorded in 561 patients (mean age: 60 +/- 8.8 years) within 10 days of coronary artery bypass grafting. Signal-averaged ECG was performed with a bandpass filtering of 40 to 250 Hz for more than 250 beats until a noise level of 0.6 microV was achieved. All patients were followed for 5.5 +/- 1.2 years after the procedure. RESULTS: Preoperative angiographic ejection fraction was at least 60% in 393 patients (72%), 40% to 60% in 126 patients (23%), and 40% or less in 28 patients (5%). There were 34 deaths, 10 of which were SCD. Late potentials were found in a total of 150 patients (27%) and were equally frequent preoperatively and postoperatively and among patients with (30%) and without (27%) SCD. The only predictors for overall mortality were age and a reduced ejection fraction. CONCLUSIONS: Signal-averaged ECG did not predict prognosis in low-risk patients undergoing coronary artery bypass grafting.

Coronary Artery Bypass↗

Serum levels and differential expression of CD44 in childhood leukemia and malignant lymphoma: correlation with prognostic criteria and survival.

BACKGROUND: The CD44, a cell surface proteoglycan, participates in a variety of function including tumor dissemination and metastasis. However, there are no available data on the prognostic significance of CD44 expression of tumor tissue correlated with serum sCD44 level in childhood leukemias and lymphomas. METHODS: Serum levels and leukemic cell tumor tissue expression of CD44 were detected in 54 children with acute leukemia and malignant lymphoma. Serum samples were obtained from all patients before treatment and during remission. Twelve age-matched healthy children were included as a control group. RESULTS: The serum CD44 levels were significantly higher in patients with Hodgkin's disease (HD), non-Hodgkin's lymphoma (NHL), Burkitt's lymphoma (BL) and acute lymphoblastic leukemia (ALL) than those in the control group. The median values were 1627.0, 1336.0, 1318.5, 1730.4, 902.7 ng/mL, respectively, and P<0.001, P<0.01, P<0.01, P<0.05 in comparisons, respectively. However, there was no significant difference between acute myeloid leukemia (AML) and the control group (median values: 900.3 and 902.7 ng/mL, respectively, P>0.05). Serum sCD44 levels significantly declined in HD, NHL and ALL patients who were in complete remission (median values: 684.0, 573.8 and 1101.1 ng/mL, respectively, P<0.05 in each comparison). Patients with HD had higher levels of serum sCD44 and correlated well with higher erythrocyte sedimentation rate (ESR), B-symptoms and advanced-stage disease (P<0.05, P<0.05 and P<0.01, respectively). Expression of CD44 was significantly high in patients with HD and NHL who were in advanced stages of disease. High serum CD44 level was also associated with high tumor tissue expression of CD44 in patients with HD and BL. In addition, patients with higher levels of serum sCD44, had a poorer outcome and survival than those with lower sCD44 levels in HD and NHL groups. CONCLUSIONS: A high serum sCD44 level and/or tumor tissue expression at diagnosis is associated with poor prognostic criteria and/or unfavorable outcome in childhood leukemias and lymphomas.

Adolescent↗

Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs.

Magnetic resonance imaging (MRI) is a widely accepted tool for the diagnosis of a variety of disease states. However, the presence of an implanted pacemaker is considered to be a strict contraindication to MRI in a vast majority of centers due to safety concerns. In phantom studies, the authors investigated the force and torque effects of the static magnetic field of MRI on pacemakers and ICDs. Thirty-one pacemakers (15 dual chamber and 16 single chamber units) from eight manufacturers and 13 ICDs from four manufacturers were exposed to the static magnetic field of a 1.5-Tesla MRI scanner. Magnetic force and acceleration measurements were obtained quantitatively, and torque measurements were made qualitatively. For pacemakers, the measured magnetic force was in the range of 0.05-3.60 N. Pacemakers released after 1995 had low magnetic force values as compared to the older devices. For these devices, the measured acceleration was even lower than the gravity of the earth (< 9.81 N/kg). Likewise, the torque levels were significantly reduced in newer generation pacemakers (< or = 2 from a scale of 6). ICD devices, except for one recent model, showed higher force (1.03-5.85 N), acceleration 9.5-34.2 N/kg), and torque (5-6 out of 6) levels. In conclusion, modern pacemakers present no safety risk with respect to magnetic force and torque induced by the static magnetic field of a 1.5-Tesla MRI scanner. However, ICD devices, despite considerable reduction in size and weight, may still pose problems due to strong magnetic force and torque.

Contraindications↗

Correlation of impedance minute ventilation with measured minute ventilation in a rate responsive pacemaker.

Although rate responsive pacing based on impedance minute ventilation (IMV) is now standard, there is almost no data confirming the relationship between IMV from an implanted pacemaker and measured minute ventilation (VE) during exercise. Nineteen completely paced adults implanted with Medtronic Kappa 400 pacemakers underwent symptom-limited maximal metabolic treadmill testing using a modified Minnesota Pacemaker Response Protocol. Minute ventilation (VE, L/min) was simultaneously measured using the flowmeter of a respiratory metabolic gas analysis system and the transthoracic impedance minute ventilation circuitry of the pacemaker. Correlation coefficients (r) were used to find the best fit line to describe the relationship between the two measurements. Mean (+/- SD) r values for the first, second, and third order polynomial equations and for log and exponential equations were: 0.92 +/- 0.08, 0.94 +/- 0.04, 0.95 +/- 0.04, 0.91 +/- 0.06, and 0.91 +/- 0.07, respectively. None of the r values were statistically different from the first order equation. Transthoracic IMV as measured by the Medtronic Kappa 400 is closely correlated to measured minute ventilation and is represented well by a first order (linear) equation.

Adult↗

Atypical left atrial flutter after intraoperative radiofrequency ablation of chronic atrial fibrillation: successful ablation using three-dimensional electroanatomic mapping.

Curative treatment of chronic atrial fibrillation (AF) remains a challenging task for electrophysiologists. Eliminating the initiating triggers by focal radiofrequency ablation in a subset of patients with paroxysmal AF and modifying the maintaining substrate by performing linear lesions within the left atrium in patients with prolonged episodes of AF are among the alternative approaches for management of these patients. Recently, a new intraoperative treatment procedure aimed at eliminating left atrial anatomic "anchor" reentrant circuits by induction of contiguous lesions using radiofrequency energy under direct vision was introduced. However, atypical left atrial flutter may occur during follow-up after intraoperative ablation of AF. These arrhythmias most likely are due to discontinuities in linear lesions; therefore, they can be successfully mapped and ablated in a subsequent percutaneous catheter ablation procedure. We report and discuss the case of a patient who underwent successful intraoperative ablation of chronic AF, but who developed atypical left atrial flutter postoperatively. Three-dimensional nonfluoroscopic electroanatomic mapping revealed a gap in the linear lesion line connecting the left upper and right upper pulmonary vein orifices. Ablation at the exit site of the breakthrough was successful.

Aged↗

Avoiding inappropriate ventricular tachycardia detection due to T-wave oversensing in an implantable cardioverter defibrillator: a novel application of the electrogram width criterion.

Appropriate sensing is an essential function of an implantable cardioverter defibrillator (ICD). T-wave oversensing by an ICD can be a serious problem in some patients, causing overestimation of the heart rate, inappropriate tachyarrhythmia detection and therapy delivery. Decreasing the sensitivity or programming longer refractory periods can sometimes overcome T-wave oversensing, but these measures may interfere with the ability of the ICD to correctly detect tachyarrhythmias. This report proposes a novel application of the electrogram (EGM) width criterion using a recently introduced detection enhancement algorithm intended to improve the specificity of ventricular tachycardia detection, to avoid T-wave oversensing. Based on the course of a case with persistent T-wave oversensing and review of previously published reports, oversensing problems in ICDs and management strategies are discussed.

Defibrillators, Implantable↗

How different from pacemaker patients are recipients of implantable cardioverter-defibrillators with respect to psychosocial adaptation, affective disorders, and quality of life?

OBJECTIVE: To assess differences in psychosocial adaptation, quality of life, and incidence of affective disorders between patients with pacemakers and those with implantable cardioverter-defibrillators (ICDs). DESIGN: Patients aged 40-70 years who underwent a first pectoral implantation of a pacemaker or an ICD system were studied. All subjects were asked to complete the hospital anxiety and depression scale (HAD), the short form general health survey (SF-36), and a specially designed device related questionnaire. Data analysis was performed for three patient groups: pacemaker (n = 76), ICD patients who received therapeutic shocks (n = 45), and ICD patients who did not receive shocks (n = 31). RESULTS: There were no differences between the three patient groups in HAD scores or in any of the SF-36 subscales or summary ratings. Probable depressive disorder (depression score > 10) was observed in 5.2%, 6.5%, and 6.6%, and probable anxiety disorder (anxiety score > 10) in 13.1%, 9.7%, 13.3% of the pacemaker, non-shocked ICD, and shocked ICD patients, respectively. There were no sex differences. However, patients in the shocked ICD group were more likely than those in the other groups to report limitations in their leisure activities, to perceive their device as a "life extender," and to admit anxiety about battery depletion and technical problems. Forty per cent of shocked ICD patients would be interested in joining a support group. CONCLUSIONS: Despite having distinctly different medical histories and treatments, patients with pacemakers and ICDs responded similarly to validated tools of health status assessment. ICD patients who had received shocks perceived their device as prolonging their life and had greater anxiety about technical problems. Their endorsement of the potential benefits of a support group warrants further investigation.

Adaptation, Psychological↗

Threshold tracking pacing based on beat by beat evoked response detection: clinical benefits and potential problems.

Continuous monitoring of pacemaker stimulation thresholds and automatic adjustment of pacemaker outputs were among the longstanding goals of the pacing community. The first clinically successful implementation of threshold tracking pacing was the Autocapture feature which has accomplished automatic ventricular capture verification for every single stimulus by monitoring the Evoked Response (ER) signal resulting from myocardial depolarization. The Autocapture feature not only decreases energy consumption by keeping the stimulation output slightly above the actual threshold, but also increases patient safety by access to high-output back-up pulses if there is loss of capture. Furthermore, it provides valuable documentation of stimulation thresholds over time and serves as a valuable research tool. Current limitations for its widespread use include the requirements for implantation of bipolar low polarization leads and unipolar pacing in the ventricle. Fusion/pseudofusion beats with resultant insufficient or even non-existent ER signal amplitudes followed by unnecessary delivery of back-up pulses and a possible increase in pacemaker output is not an uncommon observation unique to the Autocapture feature. The recent incorporation of the Autocapture algorithm in dual chamber pacemakers has been challenging because of more frequent occurrence of fusion/pseudofusion beats in the presence of normal AV conduction. Along with a review of the previously published studies and our clinical experience, this article discusses the clinical advantages and potential problems of Autocapture.

Algorithms↗

Clinical evaluation of a pacemaker algorithm that adjusts the pacing rate during sleep using activity variance.

Even though rate responsive pacemakers are able to regulate pacing rates based on sensor activity, they are set with a minimum rate that is not adjusted to provide rate decreases during sleep. The aim of this study was to evaluate the performance of the "Sleep Rate" feature, as compared to patient diaries and a validated method that identifies sleep from wrist actigraphy. In 19 patients (15 men; age 69 +/- 8 years) with Pacesetter Trilogy DR+ pacemakers, the base rate and the sleep rate were set to 80 and 50 ppm, respectively. When the patients returned 2 days later, data recorded by the pacemaker and wrist actigraph were analyzed to find the agreement in corresponding sleep/wake periods. In 17 (89%) patients, the pacemaker went into the sleep mode. The total sleep time derived from actigraphy significantly exceeded the time during which the pacemaker was in sleep mode (1156.8 +/- 83.4 vs 307.3 +/- 77.2 minutes). Frequent reversions out of the sleep mode limited the total sleep time derived from the pacemaker. Cumulative analysis of the pacemaker data showed that the maximum time in the sleep mode was 78 minutes, and exceeded 1 hour in six instances, 30 minutes in 32 instances, and 15 minutes in 83 instances. Epoch by epoch comparisons revealed a good agreement (93.6 +/- 1.8%) during wakefulness between the corresponding actigraph and pacemaker epochs. However, only 24.6 +/- 3.7% of the corresponding epochs during sleep were identical, and the overall agreement was 54.4 +/- 3.7%. Except for one patient who reported palpitations, patients did not suffer from a pacemaker rate change. The Sleep Rate feature provides rate reduction during sleep, while assuring rapid frequency response during physical activity. However, the current algorithm does not allow long periods of slow pacing rate during continuous sleep, possibly due to its conservative design and the presence of movement arousals, which has to be improved in future generation algorithms.

Aged↗

Autonomic nervous system-controlled cardiac pacing: a comparison between intracardiac impedance signal and muscle sympathetic nerve activity.

A recently introduced rate responsive cardiac pacing system is based on information derived from the intracardiac impedance signal containing information on the inotropic state of the ventricle. This study compared the inotropic state index (ISI) with muscle sympathetic activity (MSA), both being modulated by the autonomic nervous system. Nine patients (66 +/- 3 years, mean +/- SEM) with Inos2DR pacemakers were included. Each patient was studied at rest and during cold pressor test (CPT). Microneurography of the peroneal nerve was performed to measure MSA continuously, which was digitally stored along with continuous surface ECG and blood pressure. The intracardiac impedance signal was transmitted by the pacemaker and stored simultaneously. Linear correlation between ISI and MSA was calculated for the period of the CPT. During CPT, mean systolic blood pressure increased from 122 +/- 4 to 149 +/- 6 mmHg (P < 0.0001), diastolic blood pressure increased from 74 +/- 8 to 86 +/- 4 mmHg (P = 0.02), and intrinsic heart rate increased from 69 +/- 7 to 75 +/- 7 beats/mill (P = 0.019). ISI increased by 21 +/- 7% (P = 0.018), MSA by 26 +/- 6% (P = 0.004). ISI and MSA were positively correlated during the CPT in eight of nine patients (R2 = 0.86-0.99, P < 0.0001). Negative correlation was found in one patient (R2 = 0.94). This study demonstrates parallel increases of the ISI and MSA during CPT. ISI and MSA showed a close linear relationship during provoked changes of sympathetic activity. These results provide further evidence that the sympathetic nervous system is responsible for the observed ISI changes.

Aged↗

Autonomic effects of radiofrequency catheter ablation.

Radiofrequency (RF) catheter ablation has become the treatment of choice for a variety of supraventricular tachycardias. Autonomic dysfunction may occur during application of RF current; these abnormalities resolve quickly when current delivery is terminated. We present a case of sinus node arrest and AV block in a 69-year-old woman induced by RF catheter ablation of an AV nodal slow pathway. The proposed mechanisms are a Bezold-Jarisch-like phenomenon or paradoxical activation of cardiac C fibres by direct neural sympathetic stimulation or RF-induced myocardial injury. Based on a review of previously published reports, autonomic effects of RF ablation are discussed.

Aged↗