Search PubMed⌕ Search

Biomedical subjects

F Covino

Publications and source records attributed to F Covino.

5 recordsLinked to original sources

Aortic dissection with fistula to left atrium: diagnosis by transesophageal echocardiography with successful repair.

The aorta-atria fistula is an infrequent complication of aortic dissection, and it is rarely diagnosed before death. A 41-year-old man who 8 years previously had undergone prosthetic aortic valve replacement had an aortic dissection complicated by aorta-left atrial fistula. This patient had acute left heart failure associated with a systolic and diastolic murmur at the lower left sternal border suggesting an aortic prosthetic malfunction. The cardiac diagnosis was made with transesophageal echocardiography and Doppler color flow imaging; it was notable that the cardiac lesions were not detected by transthoracic echocardiography. On the basis of the echocardiographic findings, the patient underwent successful emergency replacement of the dissecting ascending aorta with closure of the aorta-left atrial fistula. Transesophageal echocardiography is the procedure of choice for defining this abnormality. In this case a prompt surgical repair consisting of replacement of the affected segment of the aorta with the prosthesis and closure of the fistula provided optimum resolution of the clinical situation.

Adult↗

Aortic dissection with fistula to right atrium after heart transplantation: diagnosis by transthoracic and transesophageal echocardiography.

Aortic dissection with rupture into the right atrium is an extremely rare and rapidly fatal condition that may occur after cardiac surgery. We report the case of a 59-year-old woman with a 6-year history of heart transplantation who presented with subacute illness characterized by chest pain and severe cardiac decompensation accompanied by a continuous murmur in the precordium. The diagnosis of aortic dissection complicated by right atrial fistula was made by the combination of transthoracic and transesophageal echocardiographic examination.

Aortic Dissection↗

[Thrombosis of aortic valve prostheses: its incidence, morphological aspects and surgical treatment].

BACKGROUND: The authors report their experience on the diagnosis, pathological findings and surgical treatment of prosthetic aortic valve thrombosis. METHODS: Between January 1976 and June 1998, 1289 mechanical prostheses were implanted in aortic position at our institution: a prosthetic obstruction was found in 12 cases. Thrombolysis was performed in two cases and as a result, pathological findings were not available and the patients were excluded from the study. Ten patients underwent surgical treatment. RESULTS: Thrombectomy was performed in one case and prosthetic replacement was done in 9 patients. One patient died postoperatively of low-output syndrome, the others were discharged and no recurrence of thrombosis has been observed at follow-up. Primary thrombosis was found in 6 cases, and pannus formation was observed in 4 patients. All patients with primary thrombosis had a history of poor anticoagulation. Patients with pannus formation had a tilting disc prosthesis. CONCLUSIONS: Use of bileaflet prostheses and adequate anticoagulation can further lessen the incidence of this dreadful complication.

Adult↗

Early experience with the Jyros bileaflet valve in the mitral position: high incidence of valve thrombosis.

The Jyros valve is a new bileaflet valve with the unusual feature that the hinge is expected to rotate continuously inside the housing. Nine isolated Jyros mitral prostheses were implanted from July to October 1993. All patients survived the surgical procedure and during the follow up underwent transthoracic (TTE) and transesophageal echocardiograms (TEE) for the evaluation of hinge rotation. Neither TTE nor TEE were able to show hinge rotation in any patient at any time. Five patients had prosthetic thrombosis. In the successfully treated with thrombolysis. In the remaining patient thrombolysis was contraindicated. Eight patients are alive; one died of gastro-intestinal bleeding a few months after discharge. The absence of hinge rotation may be the triggering mechanism of valve thrombosis although no explanted prostheses were available for examination. Further studies are necessary to understand the mechanism of valve thrombosis with the Jyros bileaflet prosthesis.

Adult↗