Factors affecting transthoracic impedance during electrical cardioversion.

Successful cardioversion is dependent on the delivery of sufficient current. Current is determined by energy and transthoracic impedance (TTI). Our purpose was to assess factors affecting TTI in humans. Twenty-eight patients undergoing elective cardioversion were monitored up to 48 hours after shock delivery. We also studied 10 normal subjects, who did not receive shocks, for comparison. TTI declined 8% in the first hour in patients who received shocks, but also 6% in the normal subjects who wore the same pads for 1 hour but received no shocks. Twenty-four hours later, TTI returned to baseline in the nonshocked subjects but remained reduced (93% of control, p less than 0.05) in the shocked patients. There was a correlation between the total energy delivered and the decline in TTI (r = 0.69). TTI was 9% lower at end-expiration than at end-inspiration (55 +/- 3 vs 50 +/- 3 ohms, mean +/- standard error of the mean, p less than 0.01, paired t test). In the normal subjects, when a nonsalt-containing coupling agent (ultrasound coupling gel) was compared with a salt-containing gel (Redux paste), TTI was 20% higher (65 +/- 5 vs 54 +/- 4 ohms, p less than 0.01) with the nonsalt-containing gel. When no coupling agent was used, TTI was markedly higher, 160 +/- 18 ohms (p less than 0.01 vs control). After 1 hour, TTI decreased 6% in the normal subjects when salt-containing gel was used, but did not change when a nonsalt gel was used.(ABSTRACT TRUNCATED AT 250 WORDS)

Arrhythmias, Cardiac↗

Energy, current, and success in defibrillation and cardioversion: clinical studies using an automated impedance-based method of energy adjustment.

The purposes of this study were two. First, we wanted to evaluate in patients a technique for automated adjustment of selected energy for defibrillation or cardioversion based on transthoracic impedance. Second, we wanted to define the relationship of peak current and shock success in various arrhythmias. Applying a previously validated method of predicting transthoracic impedance in advance of any shock, we modified defibrillators to automatically double the operator-selected energy if the predicted impedance exceeded 70 omega. Success rates of shocks given for ventricular and atrial arrhythmias from these modified energy-adjusting defibrillators were compared with success rates for shocks given from standard defibrillators. We prospectively collected data on 347 patients who received a total of 1009 shocks. Low-energy (100 J) shocks given to high-impedance (greater than or equal to 70 omega) patients had a poor success rate; in such high-impedance patients significant improvement in shock success rate was achieved by the energy-adjusting defibrillators. For example, when 100 J shocks were selected for high-impedance patients in ventricular fibrillation the energy-adjusting defibrillators achieved a shock success rate of 75%, whereas standard defibrillators achieved a shock success rate of only 36% (p less than .01). Similar improvements were seen for ventricular tachycardia and atrial fibrillation. Thus, automated energy adjustment based on transthoracic impedance is a beneficial approach to defibrillation and cardioversion. For ventricular fibrillation, atrial fibrillation, and atrial flutter there was a clear relationship between peak current and shock success.(ABSTRACT TRUNCATED AT 250 WORDS)

Arrhythmias, Cardiac↗

Pediatric defibrillation: importance of paddle size in determining transthoracic impedance.

Transthoracic impedance is a major determinant of successful defibrillation or cardioversion, but no data are available concerning the range and determinants of transthoracic impedance in children. Transthoracic impedance was measured in ten ambulatory infants, 6 weeks to 9 months of age, and 37 children, 1.5 to 15 years of age, using a previously validated "test pulse" technique that measures transthoracic impedance without actually delivering a shock. We used hand-held "pediatric" (21 cm2) and "adult" (83 cm2) electrode paddles coated with either Redux paste or Redux creme. Transthoracic impedance in children was 108 +/- 24 omega (range 61 to 212 omega) using pediatric paddles. Using adult paddles lowered the transthoracic resistance by 47% to 57 +/- 11 omega (range 29 to 101 omega), P less than .05. In infants, transthoracic impedance (measured only with pediatric paddles) was 94 +/- 17 omega (range 74 to 124 omega). Using Redux paste as the coupling agent reduced transthoracic impedance by 13% (P less than .05). Transthoracic impedance was significantly but poorly related to body weight and body surface areas, but the correlations were not sufficiently high to be clinically useful. These data indicate that the larger adult electrode paddles will minimize transthoracic impedance and should be used when the child's thorax is large enough to permit electrode to chest contact over the entire paddle surface. This transition occurred at an approximate weight of 10 kg.

Adolescent↗

Defibrillator electrode-chest wall coupling agents: influence on transthoracic impedance and shock success.

The purpose of this study was to determine if the difference in transthoracic impedance produced by different coupling agents affects the success of shocks for defibrillation. Three different coupling agents, Harco pads (Hewlett-Packard), Littman pads (3M) and Redux paste (Hewlett-Packard), were assessed in 10 anesthetized dogs in which ventricular fibrillation was induced by electrical stimulation of the right ventricle. Defibrillation was attempted 15 seconds later, using 50, 100 and 150 joules (selected energy). Actual delivered energy, current, impedance and the percent of the shocks that achieved defibrillation were determined for the three coupling agents. Redux paste gave significantly lower impedance and higher current than the two disposable performed coupling pads tested. Despite this, there were no significant differences in shock success among the three coupling agents. Thus, in this experimental model, over a three-fold energy range, disposable coupling pads were as effective as electrode paste for defibrillation despite the slightly higher impedance of the disposable pads.

Alcohols↗

Automated impedance-based energy adjustment for defibrillation: experimental studies.

In defibrillation, current flow depends on the energy selected and the transthoracic impedance. If transthoracic impedance is high, current flow may be inadequate to defibrillate. We developed a method by which high transthoracic impedance is automatically compensated for by an increase in operator-selected energy when impedance is high. Transthoracic impedance was predicted in advance of the first shock by passing a low-level current between the defibrillator electrodes during the defibrillator charge cycle; a microprocessor monitored current flow and determined impedance. In 28 mongrel dogs we manipulated transthoracic impedance by placing glycerin-soaked gauze pads between the paddle electrodes and the chest. If the predicted impedance exceeded a preset value, the delivered energy was automatically increased by 40% or 100%. Using this impedance-based energy adjustment technique, we found significant improvements in current flow and success rate of shocks when energy was automatically increased to compensate for high transthoracic impedance. The use of transthoracic impedance as a basis for energy adjustment appears a promising technique to minimize the hazards of high electrical energy; it allows low-energy shocks in most patients while avoiding inappropriate low energies in patients with high impedance. Clinical trials are justified.

Animals↗

Advance prediction of transthoracic impedance in human defibrillation and cardioversion: importance of impedance in determining the success of low-energy shocks.

The purposes of this study were to evaluate a method that predicts transthoracic impedance in advance of defibrillating shocks in humans and to assess the importance of transthoracic impedance in low-energy defibrillation. Via defibrillator electrodes we applied 31 kHz current to the chest during the defibrillator charge cycle, before the defibrillating shock was actually delivered. The current flow was limited by transthoracic impedance; a microprocessor monitored the predischarge current flow and determined the predischarge impedance by calibration against known resistance values. Actual impedance to the defibrillating shock was also determined and compared with the predicted impedance. With this approach we predicted impedance in 19 patients who received 66 shocks for ventricular and atrial arrhythmias. Predicted impedance (y) correlated very well with actual impedance (x):y = .90x + 11.3; r = .97. To determine the importance of impedance in defibrillation and cardioversion, we prospectively gathered data from 96 patients who received shocks of various energies for ventricular or atrial arrhythmias. In patients with high transthoracic impedance (greater than 97 omega), low-energy shocks (less than or equal to 100 J) for ventricular defibrillation had only a 20% success rate as opposed to a 70% success rate for low-energy shocks in patients with low or average impedance (p less than .05). We conclude that transthoracic impedance can be accurately predicted in advance of defibrillation and cardioversion. This method permits the preshock identification of patients with high impedance in whom attempts to defibrillate with low-energy shocks are inappropriate.

Arrhythmias, Cardiac↗

No evidence for involvement of KCNN3 (hSKCa3) potassium channel gene in familial and isolated cases of schizophrenia.

Several studies have reported in schizophrenia a decrease of age of onset in successive family generations, and this observation is consistent with anticipation. Anticipation is known to result from expansion of CAG repeats in several neurodegenerative disorders. Longer alleles of the KCNN3 gene, which contains a highly polymorphic CAG repeat, and encodes a neuronal small conductance calcium-activated potassium channel, have recently been shown to be over-represented in sporadic cases of schizophrenia. In this report, we tested the hypothesis of an association between longer alleles of CAG repeat in the KCNN3 gene and schizophrenia in 20 families with clinical evidence for anticipation and in 151 unrelated schizophrenic cases. No significant difference in the distributions of allele frequencies was observed between familial cases of schizophrenia and controls, and between unrelated cases and controls. Furthermore, no intergenerational CAG repeat instability was detected in the 20 families. Our results do not support the involvement of the KCNN3 (hSKCa3) gene in the etiology of schizophrenia.