Search PubMedSearch

Biomedical subjects

F C Taylor

Publications and source records attributed to F C Taylor.

At least 19 recordsLinked to original sources

Endovascular stent infection.

We report a case of iliac stent infection. Nine days after a 24-hour infusion of urokinase and right iliac artery stent deployment, the patient had fever, in addition to severe groin pain and petechiae isolated to the stented limb. The hospital course was complicated by sepsis, adult respiratory distress syndrome, liver dysfunction, and renal insufficiency. Stent removal and iliac/femoral artery resection, as well as an above-knee amputation, were life-saving. Arterial and stent cultures grew Staphylococcus aureus. Stent infection with arterial necrosis is a devastating, rare endovascular complication. Given its potential seriousness, we would recommend the use of prophylactic antibiotics before stent deployment.

Amputation, Surgical

Stenting without thrombolysis for aortoiliac occlusive disease: experience in 14 high-risk patients.

Stenting without thrombolysis of 16 occluded iliac artery segments and one occluded infrarenal abdominal aorta was attempted in 14 patients. All patients were either considered to be prohibitive operative risks or had contraindications to thrombolytic therapy. Indications for limb reperfusion included rest pain, disabling claudication, or dry gangrene. Successful recanalization was achieved primarily in 13 patients with self-expandable Wallstents, balloon-expandable Palmaz stents, or a combination of the two stents. Follow-up was carried out in all patients in whom recanalization was successful. All stented patients showed symptomatic improvement, and the mean preprocedure ankle/brachial index, which was 0.31, improved to 0.78 after the procedure (p = 0). Complications included a vertebrobasilar stroke during the procedure in one patient, perforation during angioplasty of a stenotic but nonoccluded external iliac artery in one, and dissection of the distal external iliac artery in one. Distal embolization did not occur. Percutaneous recanalization of aortoiliac occlusions without initial thrombolysis is possible and has a high potential for technical success. Additional data and longer follow-up are still needed, but this procedure may provide a reasonable, less invasive option in some patients at high surgical risk or in patients who have contraindications to thrombolytic therapy.

Aged

Dimenhydrinate pretreatment in patients receiving intra-arterial ioxaglate: effect on nausea and vomiting.

OBJECTIVE: To determine the effectiveness of the antihistamine dimenhydrinate (Dramamine) as a prophylactic agent against the nausea and vomiting that occasionally accompany the use of ioxaglate. PATIENTS AND METHODS: Three hundred patients (165 men and 135 women, ranging in age from 18 to 89 [mean 62] years) undergoing noncoronary arteriography received dimenhydrinate or placebo before the injection of the low-osmolality contrast material ioxaglate (Hexabrix). The patients were observed and questioned about nausea and vomiting, as well as many other possible reactions to the contrast material. RESULTS: There were no statistical differences in the occurrence of adverse reactions between the groups receiving dimenhydrinate and placebo (chi 2 or Fisher's exact test, p > 0.05). CONCLUSION: Dimenhydrinate, as administered in this study, was ineffective as a prophylactic agent against adverse reactions accompanying administration of ioxaglate.

Adolescent

Recurrent urinary conduit bleeding in a patient with portal hypertension: management with a transjugular intrahepatic portosystemic shunt.

OBJECTIVE: To determine if a transjugular intrahepatic portosystemic shunt can control recurrent urinary conduit bleeding in a patient with portal hypertension. METHODS: Following transjugular catheterization of the right hepatic vein, a long curve Colapinto needle was advanced through the liver parenchyma into the portal vein near its bifurcation. After a guide wire exchange, a catheter was advanced into the portal system and venogram was obtained. Following another guide wire exchange, a balloon angioplasty catheter was used to create the shunt by dilating the parenchymal tract between the hepatic and portal veins. A self-expandable stent was used to ensure patency of the shunt. RESULTS: After shunt placement, bleeding from the ileal conduit and stroma decreased significantly. A duplex ultrasound at five-month follow-up demonstrated the shunt to be completely patent. CONCLUSIONS: Based on this limited experience, it appears that the transjugular, intrahepatic, portosystemic shunt is an acceptable method to control massive, recurrent urinary conduit bleeding in patients with portal hypertension.

Aged

Comparison of filters in an oversized vena caval phantom: intracaval placement of a bird's nest filter versus biiliac placement of Greenfield, Vena Tech-LGM, and Simon nitinol filters.

For patients with an oversized inferior vena cava (IVC) (diameter greater than 28 mm, corrected for magnification) who require vena caval filtration for prophylaxis against pulmonary emboli, the accepted treatment has been the biiliac venous placement of Greenfield filters. Because of its wide strut span, the Bird's Nest filter (BNF) has been successfully placed in patients having an oversized IVC. However, the effects of the BNF on caval blood flow and its clot-capturing ability in an oversized IVC are not clearly understood. The authors created a flow phantom simulating an oversized IVC with "iliac" tributaries of normal inner diameter to analyze flow turbulence, pressure gradients, and the clot-capturing ability of the BNF, tested within the "caval" segment of the phantom, and the Greenfield, Vena Tech-LGM, and Simon nitinol filters, tested in the "iliac" segments. All filters were tested for flow disturbances before and after clot capture. The authors' results demonstrate that within an oversized IVC, the BNF creates less flow disturbance and is less occlusive with clot capture than biiliac filters. The BNF displayed a clot-capturing ability equal to that of biiliac filters. Thus, for patients with an oversized IVC, these results suggest that placement of a single intracaval BNF is preferable to biiliac placement of filters.

Humans

Vena Tech vena cava filter: experience and early follow-up.

Vena caval filters, such as the Vena Tech filter, that employ low-profile introducer systems have provided physicians with a variety of options for percutaneous placement. From April 1989 to April 1990, 81 patients underwent percutaneous placement of the Vena Tech filter at the authors' institution. Follow-up has been obtained to evaluate the filter with regard to the prevention of pulmonary embolism, the maintenance of caval patency, and mechanical stability. Two cases of pulmonary embolism have been seen following filter placement. Three cases of caval thrombosis have occurred, with recanalization of the cava seen in two of these cases. There have been one broken filter and one case of incomplete filter opening. Limited filter tilting and migration have occurred, though in no case has filter tilt or migration been clinically significant. This experience with the Vena Tech filter suggests that it is safe and effective for the prevention of pulmonary embolism.

Adolescent

Incomplete opening of LGM (Vena Tech) filters inserted via the transjugular approach.

Over a 12-month period, 216 LGM vena caval filters were placed in 216 patients at four institutions. The transjugular approach was used in 31 of 216 insertions (14%); 185 of 216 filters (86%) were inserted via the femoral route. Incomplete opening of filters was encountered in 13 of 31 transjugular insertions (41%) and none of 185 transfemoral insertions. Delayed spontaneous filter opening occurred in three of 12 cases (25%) of incomplete opening (in which follow-up was available) at 5 minutes, 4 days, and 2 months after insertion. One filter opened completely after catheter manipulations. Several mechanisms explaining this complication are proposed. In its present form, the LGM filter should not be inserted via the jugular route. Since the filtering capabilities of the incompletely opened LGM device have been shown to be diminished in vitro, it may be advisable to place a second filter cephalad to an incompletely opened LGM filter.

Equipment Failure

Use of the Bird's Nest filter in oversized inferior venae cavae.

An inferior vena cava (IVC) diameter of greater than 28 mm has been considered a contraindication to the intracaval placement of Greenfield, LG-Medical (LGM), and Simon nitinol filters, necessitating biiliac placement of these devices. With the Bird's Nest filter (BNF), the maximum span of the struts, which immobilize the device, is 60 mm; this allows the placement of the BNF in an oversized IVC having a diameter of greater than 28 mm. Over a 44-month period, 799 IVC filters (547 BNF, 136 Greenfield filters, and 116 LGM filters) were inserted. BNFs were placed in 18 patients (2.3%) with an oversized IVC (diameter range, 29-42 mm); all filters were placed via the femoral route. Patient records were reviewed to determine if problems were associated with filter insertion (including insertion site femoral vein thrombosis) and to determine the prevalence of filter migration, caval thrombosis, and new or recurrent pulmonary emboli (PE) after insertion. No difficulties were encountered during insertion. There was no documented case of device migration, caval thrombosis, or clinically apparent new or recurrent PE. The data suggest that the BNF is the filtering device of choice in patients with an oversized IVC.

Adult

Late presentation of splenic trauma after routine colonoscopy.

Splenic trauma is a rare complication of colonoscopy and is often not readily diagnosed. A computerized tomographic scan enabled us to diagnose splenic trauma without hematoperitoneum in a patient presenting with abdominal and left shoulder pain 10 days post-colonoscopy. The scan information and the patient's clinical status allowed for nonoperative treatment of the injury.

Colonoscopy

Left femoral vein approach for the percutaneous placement of the Bird's Nest Filter.

The Bird's Nest Filter femoral catheter set has proven to be too short in some patients to permit placement in close proximity to the renal veins via the left femoral vein approach. The use of the longer, but otherwise identical Bird's Nest Filter jugular catheter set via the left femoral vein eliminates this problem.

Femoral Vein