Clinical and radiologic outcome of off-pump coronary surgery at 12 months follow-up: a prospective randomized trial.

BACKGROUND: After more than a decade of experience with off-pump coronary bypass surgery, still no consensus exists concerning its benefit on clinical outcome compared to the on-pump technique. In this 12-month follow-up, we compare off-pump and on-pump surgery on the appearance of graft patency, myocardial function, and clinical outcome. METHODS: One hundred twenty patients were randomized to off-pump or on-pump coronary surgery. Angiography was performed intraoperatively, at 3 and 12 months. Global myocardial function was estimated by magnetic resonance imaging (MRI) preoperatively and 12 months postoperatively, as well as functional class and stress testing. RESULTS: After 12 months internal mammary artery patency was 94% in the off-pump group and 96% in the on-pump group. Vein graft patency was 80% and 87%, respectively. No statistically significant difference between the two groups existed. There were no differences in exercise capacity improvement and attenuation of symptoms between the groups. CONCLUSIONS: At 12-months follow-up, off-pump coronary bypass surgery provided the same angiographic graft patency as the on-pump technique. Improvement in functional class and exercise capacity was the same in both groups.

Aged↗

Wireless continuous arterial blood pressure monitoring during surgery: a pilot study.

Patient monitoring devices supporting wireless transmission can facilitate transport and ambulation of patients in hospitals. To replace wired sensors with wireless sensors, the accuracy and resistance to interference of the wireless sensors have to be documented. We compared the performance of a wireless arterial blood pressure biomedical sensor prototype with standard wired sensors in a clinical setting. Four patients undergoing laparoscopic abdominal surgery were recruited for testing of the device. Lines to a wireless arterial blood pressure sensor and standard wired sensor were connected to the same arterial cannula inserted in the right radial artery. Data from both systems were logged for postprocedure statistical comparison. During the procedure, 13 other electric devices were used, either continuously or intermittently. A sample-by-sample comparison was performed for both wired and wireless data. Statistical tests showed mean difference of 0.71, standard deviation of 0.14, and confidence interval of -1.28 to 1.56), indicating no significant electromagnetic interference on invasive arterial blood pressure monitoring caused by biomedical devices used during surgery. The wireless pressure biomedical sensor with Bluetooth wireless transmission of signals did not interfere with biomedical devices used in the operating room or vice versa.

Abdomen↗

Early recognition of regional cardiac ischemia using a 3-axis accelerometer sensor.

Perioperative mortality in coronary artery bypass grafting is usually caused by reduced left ventricular function due to regional myocardial ischemia or infarction. Post-operative graft occlusion is a well-known problem in coronary surgery. A sensitive tool to detect graft occlusion and monitor myocardial function may give the opportunity to revise malfunctioning grafts before departure from the hospital. This paper describes how a new method can detect cardiac ischemia using a 3-axis piezoelectric accelerometer. In three anesthetized pigs, a 3-axis piezoelectric accelerometer was sutured on the lateral free wall of the left ventricle. The left anterior descending (LAD) was occluded for different time periods and the accelerometer data were sampled with a PC. Short-time Fourier transform was calculated based on the accelerometer time series. The results were visualized using a 2D color-coded time-frequency plot. In the area of occlusion, a change to stronger power of higher harmonics was observed. Consequently, a difference value between the instant frequency pattern and a reference frequency pattern showed a rise in absolute value during the occlusion period. The preliminary results indicate that early recognition of regional cardiac ischemia is possible by analyzing accelerometer data acquired from the three animal trials using the prototype 3-axis accelerometer sensor.

Acceleration↗

Laparoscopic liver resection: experience of 53 procedures at a single center.

BACKGROUND/PURPOSE: The short-term outcome following laparoscopic liver resection at a single center is presented. METHODS: Fifty-three procedures were carried out in 47 patients, between August 1998 and April 2004 (6 patients were resected on two occasions). A previous laparotomy and/or hepatectomy had been done in 83% and 26% of the procedures, respectively. Colorectal metastasis was the main indication for treatment (42/53). A total laparoscopic approach was applied. RESULTS: Three of the 53 (6%) procedures were converted to laparotomy. In one additional procedure, radiofrequency ablation was done instead of resection. Sixty liver resections were done during the 49 procedures completed laparoscopically as planned (9 patients had concomitant resections performed). Nonanatomic (45/60) and anatomic (15/60; left lobectomies) resections were done. Tumor tissue was found in the resection margins of 6% of the specimens. The free margin was very short in 8% of the specimens. The morbidity was 16%. There was no mortality. Blood transfusions were given following 26% of the procedures. The median hospital stay was 3.5 days (range, 1-14 days) and the median number of days on which there was a need for opioids was 1 (range, 0-11 days). CONCLUSIONS: Laparoscopic liver resection can be performed safely and seems to offer short-term benefits to the patients. Randomized studies are required to further evaluate the potential benefits of this treatment.

Adult↗

Patient-reported outcome after randomization to on-pump versus off-pump coronary artery surgery.

BACKGROUND: Clinical experience with off-pump coronary artery bypass surgery raises the question of a patient experienced benefit compared with on-pump surgery. This prospective and randomized study compared patient-reported outcome between surgical groups, as change scores at 3 months after surgery and longitudinally as time-averaged change from baseline through the first year after surgery. METHODS: In all, 120 patients were randomly assigned to on- or off-pump coronary artery surgery. A questionnaire for patient self-report of angina (Canadian Cardiovascular Society scale), health status (Short Form 36, sleep and sexual difficulty), and overall quality of life (Quality of Life Scale) was administered at baseline and at 3, 6, and 12 months after surgery. RESULTS: Patient groups were comparable with regard to age, symptoms, comorbidity, and surgical characteristics. Both groups experienced a median of two classes relief of angina at 3 months (p < 0.0005), maintained throughout follow-up. Paired t tests revealed significant improvement on all Short Form 36 subscales at 3 months after surgery, with the exception of physical role functioning in the on-pump group. No independent main effects of surgical group were observed in the between-groups covariance models. The longitudinal effect of sex was significant in four Short Form 36 subscales: physical functioning, bodily pain, and role limitation due to physical or emotional problems. Overall quality of life scores were stable in both groups. CONCLUSIONS: Both on-pump and off-pump patients reported less angina and improved health status after surgery. There were no significant differences between surgical groups in health status or overall quality of life, neither cross-sectionally nor longitudinally.

Aged↗

Cerebral ischemic injury and cognitive impairment after off-pump and on-pump coronary artery bypass grafting surgery.

BACKGROUND: Off-pump coronary artery bypass grafting surgery reduces the intraoperative cerebral embolic load and may therefore cause less brain injury. The main aim of this study was to compare off-pump and on-pump surgery with regard to the frequency of new postoperative cerebral ischemic lesions and the prevalence of postoperative cognitive impairment. We also assessed whether preoperative cerebral ischemic injury predicts the risk for cognitive dysfunction after surgery. METHODS: One hundred twenty patients with ischemic coronary artery disease were prospectively randomized to undergo off-pump or on-pump surgery. A detailed neuropsychological assessment and a cerebral magnetic resonance imaging examination were performed on the day before and at 3 months postoperatively. The neuropsychological assessment was repeated at 12 months. RESULTS: There was no significant (p = 0.17) difference between off-pump (8.2%) and on-pump (17.3%) surgery with regard to new postoperative cerebral lesions. The prevalence of cognitive impairment after surgery was also similar in the two groups (3 months: off-pump 20.4%, on-pump 23.1%, p = 0.74; 12 months: off-pump 24.1%, on-pump 23.1%, p = 0.90). The degree of preoperative cerebral ischemic injury was significantly associated with cognitive dysfunction after on-pump (p = 0.02) but not after off-pump (p = 0.22) surgery. None of the patients with normal preoperative radiologic findings were found to have cognitive impairment at 3 months postoperatively (p = 0.04). CONCLUSIONS: Long-term cognitive function and magnetic resonance imaging evidence of brain injury were similar after off-pump and on-pump coronary artery bypass grafting surgery. Preoperative cerebral magnetic resonance imaging can be used to predict the risk for cognitive dysfunction after coronary artery bypass grafting surgery.

Adult↗

Preoperative cerebral ischemic lesions predict physical health status after on-pump coronary artery bypass surgery.

BACKGROUND: Risk assessment is integral to patient selection and counseling before coronary artery revascularization. We studied the predictive ability of cerebral magnetic resonance imaging of preoperative and postoperative cerebral ischemic injury on self-reported physical and mental health at 3 months after coronary artery bypass surgery with or without use of cardiopulmonary bypass. METHODS: In a prospective clinical trial comparing on-pump and off-pump surgery, 120 patients responded to a questionnaire for self-report of angina (Canadian Cardiovascular Society scale) and physical and mental health status (Short Form 36) at baseline before preoperative cerebral magnetic resonance imaging. Preoperative sets of both magnetic resonance imaging and self-assessments were available for 103 (85.8%) patients. These patients were grouped according to classification of preoperative cerebral magnetic resonance imaging findings. Analysis of covariance determined the association of (1) preoperative magnetic resonance imaging status, (2) new postoperative cerebral lesions, and (3) actual use of cardiopulmonary bypass to physical and mental health. RESULTS: At 3 months after surgical intervention, 98 of 103 patients completed follow-up. The analysis revealed an interaction effect of preoperative cerebral ischemic injury and use of cardiopulmonary bypass on physical health (F = 9.07, P = .003) independent of age. No independent effects on health status were found of baseline magnetic resonance imaging or new cerebral lesions at 3 months. CONCLUSIONS: This study strongly suggests that the combination of preoperative cerebral ischemic injury and use of cardiopulmonary bypass can predict postoperative health status at 3 months. Cerebral magnetic resonance imaging might be a more specific indicator than age for preoperative assessment of vulnerability or resilience during rehabilitation after on-pump cardiac surgery.

Adult↗

Cerebral microembolization during off-pump coronary artery bypass surgery with the Symmetry aortic connector device.

OBJECTIVE: The use of aortic connector systems for proximal vein grafts in off-pump coronary artery bypass grafting might minimize aortic manipulation by eliminating the need for partial aortic clamping. The objective of this study was to asses whether use of a Symmetry connector (St Jude Medical, Inc, St Paul, Minn) reduced intraoperative cerebral embolization. METHODS: Thirty-two consecutive patients underwent off-pump coronary artery bypass grafting. Sixteen patients received at least one mechanical proximal vein graft anastomosis with a Symmetry aortic connector system. Sixteen patients representing the control group underwent operations with standard suturing techniques using partial aortic clamping. During surgical intervention, all patients were monitored continuously with multifrequency transcranial Doppler scanning, which detected and differentiated cerebral emboli. RESULTS: There were significantly more cerebral emboli in the Symmetry group (median, 36) compared with the control group (median, 11; P = .027). This was due to a higher number of gaseous emboli in the Symmetry group than in the control group (median, 27 vs 8; P = .014), whereas there was no significant difference regarding the number of solid emboli (median, 7 vs 3; P = .139). CONCLUSION: Use of a Symmetry connector system during proximal vein graft anastomosis increased the number of emboli to the brain compared with a standard technique in coronary bypass surgery without cardiopulmonary bypass.

Aged↗

Simulators in surgery.

The introduction of minimally invasive surgery has demonstrated the need for training surgical skills outside the operating room using animal models or simulators. As laparoscopic surgery involves displaying images on a screen, virtual reality simulation of the surgical tasks is feasible. Different types of simulators have become available. The existing trainers can be divided into three groups: mechanical, hybrid, and virtual reality. This article aims at giving an overview of the different simulators available and the potential of simulators in the education of surgeons with focus on virtual reality simulators. All simulators aim at training psychomotoric skills and some simulators also allow training in decision-making and anatomical orientation. In the future virtual reality simulators may become a tool for training and validation of surgical skills and monitoring the training progress.

Journal Article↗

Living donors' experiences 1 wk after donating a kidney.

In Norway living kidney donors account for approximately 40% of all renal transplants. There is a shortage of information about how living kidney donors experience the donation process during the initial recovery from surgery. The aim of this study was to explore physical and psychosocial issues related to the experiences of living kidney donors 1 wk after open donor nephrectomy. A total of 12 living kidney donors participated in the study. Data were collected by individual in-depth interviews and analysed using empirical phenomenological method. Being a living kidney donor is a complex experience. The informants expressed strong feelings of responsibility and obligation concerning the recipients and had a positive attitude towards the donation. On the other hand, the donors experienced it strange to be a fit individual and go through a major operation. Several of the donors reported that it was painful to go through donor surgery and regarded the recovery period as troublesome. Some donors also reported the double role of being both a patient and a relative to be a stressful experience. This study reveals the importance of being aware of the complex situation of living kidney donors. Health professionals need to understand the nature of the donation process and the donors' needs. It is essential to focus on physical, mental and interpersonal factors when counselling potential living kidney donors.

Adolescent↗

Clinical and Angiographic Outcome of Coronary Surgery with and without Cardiopulmonary Bypass: A Prospective Randomized Trial.

Abstract Background: Off-pump coronary artery bypass surgery has emerged as an alternative technique to traditional onpump surgery. The aim of this randomized study was to compare perioperative morbidity and mortality and intraoperative and short-term graft patency in off-pump and on-pump coronary artery bypass grafting. Methods: One hundred twenty patients were randomized for coronary revascularization with or without cardiopulmonary bypass. In all patients grafts and anastomoses were monitored with transit time Doppler ultrasonography and angiography. Angiography was repeated 3 months after the procedure in 115 of the patients. Results: Angiography 3 months postoperatively revealed that internal mammary artery patency was 98% in both groups. Vein graft patency was 83% in the off-pump group and 91% in the on-pump group, a difference that was not statistically significant. One perioperative death was recorded in each group. Two strokes were recorded in the on-pump group, none in the off-pump group. Conclusion: In this prospective, controlled study, perioperative and short-term outcome of off-pump coronary surgery equaled that of on-pump surgery.

Journal Article↗

Improvement of coronary artery fistula surgery by intraoperative imaging.

Complete surgical closure of coronary artery fistulas may be difficult because of complex anatomy and often multiple sites of origin. This study therefore assessed whether intraoperative fistula imaging would contribute to and improve the final surgical result. Seven adult patients underwent operation for coronary arteriovenous fistula during a 10-year period. In all 4 patients who had image guidance, the operation was guided by immediate imaging to achieve complete and persistent closure. In contrast, 2 of 3 patients who underwent operation without image guidance had residual left-to-right shunts at follow-up. Image guidance was helpful and increased the success rate of surgical closure of coronary artery fistulas.

Adult↗

Intraoperative angiography leads to graft revision in coronary artery bypass surgery.

BACKGROUND: Graft anastomosis quality in coronary artery bypass surgery can be assessed by intraoperative angiography. The aim of the present study was to quantify the on-table revision rate initiated by intraoperative angiography. METHODS: Intraoperative angiography was carried out in 186 patients undergoing coronary artery bypass surgery, with a total of 427 grafts. The operation was performed on-pump in 34%, off-pump through a sternotomy in 49%, and as a minimally invasive direct coronary bypass grafting (MIDCAB) procedure in 17%. The angiography was performed intraoperatively while the patients were still in general anesthesia, with the possibility for on-table revision. Follow-up angiography was carried out after a mean of 346 days. RESULTS: Eighteen of 427 grafts (4.2%) were revised due to the findings at intraoperative angiography. Revision rate after on-pump surgery was 1.1%, after off-pump through a sternotomy 6.4%, and after MIDCAB 6.5%. In 6 patients the lesions were located at the distal anastomoses and in 12 patients in the conduit. All but one was successfully revised, and at 1-year follow-up all these 17 grafts were patent. CONCLUSIONS: Intraoperative angiography saves a potential number of grafts that otherwise could have been occluded. An increased implementation of intraoperative quality assessment in coronary artery bypass surgery can lead to improved outcome.

Adult↗

Detection of ischemia and new insight into left ventricular physiology by strain Doppler and tissue velocity imaging: assessment during coronary bypass operation of the beating heart.

BACKGROUND AND OBJECTIVES: Detection of myocardial ischemia in humans by strain Doppler and tissue velocity imaging was validated in a novel, experimentally designed study model during coronary bypass operation of the beating heart. METHODS: Assessment of ischemia was made with an opened chest and pericardium inherent in the operative procedure. Longitudinal strain and tissue velocity of interventricular septal regions were measured by transesophageal echocardiography during occlusion of the left anterior descending coronary artery (LAD). RESULTS: Unexpectedly, baseline velocities demonstrated that the apical and basal septum moved toward each other during systole. This occurred when the apex was dislodged from the pericardial sac to obtain access to the LAD, without any change in strain. The preceding motion of all septal regions toward the apex was reestablished after the heart was repositioned within the pericardium. In 16 patients with antegrade LAD flow, strain Doppler detected ischemia during LAD occlusion by disclosing systolic lengthening of the apical septum ( P <.01) and reduced shortening of the mid septum ( P <.05). The location and degree of ischemic changes coincided with the concomitant deterioration of wall motion. Tissue velocity changed in the basal and mid septum ( P <.05) but not in the apical region, explained by tethering effects and the distinctive motion pattern at baseline. There was no evidence of ischemia by invasive hemodynamic measures. In 7 patients with retrograde LAD flow, there were no significant changes in strain or tissue velocity measurements during LAD occlusion. CONCLUSIONS: Strain by Doppler is a sensitive means for detecting myocardial ischemia, also capable of correctly localizing the ischemia, as opposed to tissue velocity assessment. However, velocity measurements provided new physiological information by disclosing the normal longitudinal motion of the heart to be dependent on the pericardial sac enveloping the apex, irrespective of the structural integrity of the pericardium.

Aged↗

Intraoperative and intermediate-term angiographic results of coronary artery bypass surgery with Symmetry proximal anastomotic device.

OBJECTIVE: The objective of this study was to investigate the patency in saphenous vein coronary bypass grafts in which the proximal anastomoses were performed with automatic connector devices or with a traditional suture technique. METHODS: Forty-six patients underwent coronary artery bypass grafting without cardiopulmonary bypass by using one thoracic graft and one or more saphenous vein grafts. Grafts were attached to the aorta with a Symmetry connector (St Jude Medical, Inc, St Paul, Minn) in 23 patients, and partial occlusion of the aorta and sutured anastomoses were used in 23 other patients. Grafts were studied intraoperatively with transit time flowmetry and angiography and revised if necessary. Angiography was repeated after 3 to 5 months. RESULTS: Intraoperative graft patency did not differ between the 2 groups. Follow-up angiography demonstrated excellent thoracic graft patency. Vein graft patency decreased to 50% in the Symmetry group, whereas it was 90% in the suture group ( P = .01). Twenty-five percent of the Symmetry grafts had significant stenosis in the connector. CONCLUSION: Saphenous vein grafts anastomosed to aorta with the Symmetry proximal connector have low intermediate patency compared with those with traditionally sutured anastomoses. We do not recommend the routine use of this device in coronary artery bypass operations.

Aged↗

Integrating surgery and radiology in one suite: a multicenter study.

PURPOSE: The study was performed to evaluate the performance of digital fixed-mounted angiographic C-arm systems in the operating room as used by surgeons, cardiologists, and interventional radiologists. METHODS: An observational study in the operating room was performed, along with a structured questionnaire and semi-structured interviews. Twenty interventions were observed at 5 sites. Workflow was analyzed. RESULTS: Integration of high-end angiographic imaging equipment in the operating room enables image-guided surgery with high-quality images, on-table quality assessment of surgical procedures, and "one-stop shopping" procedures. Integrated suites were run by surgery as well as radiology departments, and are used for a variety of procedures, including vascular, cardiothoracic, open surgical, percutaneous, and combined procedures. Operation of the angiographic system and its user interface design were not considered ideal for operating room use. Limited patient accessibility was observed, sometimes leading to uncomfortable positions for the operating physicians. Certain procedures, such as tibial artery surgery, were difficult to perform, owing to lack of accessories. Patient transfer was considered inadequate. Cleaning of the system was rated as poor. Operating room use puts an even higher demand on reliability of the system. CONCLUSION: Integration of digital angiographic systems into operating rooms has produced opportunities for new treatments and offers a superior solution for interdisciplinary work among surgeons, cardiologists, and radiologists. However, the context of use differs radically from that in the traditional radiologic examination room; the environment, users, and procedures are all different. Integration of imaging methods into the operating room can be more successful if special operating room conditions are taken into account by medical systems manufacturers.

Angiography↗