Search PubMed⌕ Search

Biomedical subjects

Ergin Atalar

Publications and source records attributed to Ergin Atalar.

34 records · Page 2Linked to original sources

Evaluation of internal MRI coils using ultimate intrinsic SNR.

The upper bounds of the signal-to-noise ratio (also known as the "ultimate intrinsic signal-to-noise ratio" (UISNR)) for internal and external coils were calculated. In the calculation, the body was modeled as a dielectric cylinder with a small coaxial cylindrical cavity in which internal coils could be placed. The calculated UISNR values can be used as reference solutions to evaluate the performance of internal MRI coils. As examples, we evaluated the performance of a loopless antenna and an endourethral coil design by comparing their ISNR with the UISNR.

Computer Simulation↗

SSFP-based MR thermometry.

Of the various techniques employed to quantify temperature changes by MR, proton resonance frequency (PRF) shift-based phase-difference imaging (PDI) is the most accurate and widely used. However, PDI is associated with various artifacts. Motivated by these limitations, we developed a new method to monitor temperature changes by MRI using the balanced steady-state free precession (balanced-SSFP) pulse sequence. Magnitude images obtained with the SSFP pulse sequence were used to find the PRF shift, which is proportional to temperature change. Spatiotemporal temperature maps were successfully reconstructed with this technique in gel phantom experiments and a rabbit model. The results show that the balanced-SSFP-based method is a promising new technique for monitoring temperature.

Animals↗

In vivo magnetic resonance imaging of mesenchymal stem cells in myocardial infarction.

BACKGROUND: We investigated the potential of magnetic resonance imaging (MRI) to track magnetically labeled mesenchymal stem cells (MR-MSCs) in a swine myocardial infarction (MI) model. METHODS AND RESULTS: Adult farm pigs (n=5) were subjected to closed-chest experimental MI. MR-MSCs (2.8 to 16x107 cells) were injected intramyocardially under x-ray fluoroscopy. MRIs were obtained on a 1.5T MR scanner to demonstrate the location of the MR-MSCs and were correlated with histology. Contrast-enhanced MRI demonstrated successful injection in the infarct and serial MSC tracking was demonstrated in two animals. CONCLUSIONS: MRI tracking of MSCs is feasible and represents a preferred method for studying the engraftment of MSCs in MI.

Animals↗

MRI-guided coronary catheterization and PTCA: A feasibility study on a dog model.

The aim of this work was to demonstrate the feasibility of MRI-guided coronary artery catheterization and intervention in a dog model. Experiments were performed on 10 healthy dogs. A 9F introducer sheath was placed through a right carotid artery cutdown. A prototype 0.014-inch coronary MRI guidewire, a prototype 7 French MRI-guiding catheter, and two flexible surface coils were connected to a GE 1.5 T CV/i scanner for simultaneous visualization of the guidewire, guiding catheter, and chest anatomy. Images were displayed in real time on an in-room monitor. A nongated, single-slice fast gradient-echo sequence was used to obtain real-time images of the catheters and background anatomy during the intervention. Fifteen selective catheterizations were attempted in the coronary arteries, and all were successful. Selective injection of diluted gadolinium into the MRI-guiding catheter provided dynamic 2D projection coronary angiography in all cases, confirming successful catheterization. Percutaneous transluminal coronary angioplasty (PTCA) was attempted after two catheterizations, and all attempts were successful. Inflation of the balloon angioplasty catheter was performed successfully in the left anterior and circumflex arteries. Our results indicate that coronary artery catheterization and intracoronary balloon angioplasty are feasible with MRI guidance only. MRI guidance may be used as an alternative to X-ray guidance in coronary artery interventions in the future.

Angioplasty, Balloon, Coronary↗

Phased-array MRI of canine prostate using endorectal and endourethral coils.

A four-channel phased array consisting of one surface coil, two endorectal coils, and one flexible endourethral loop coil was designed for MRI of the canine prostate. The endorectal coils provide high signal in the posterior region of the prostate, while the endourethral and surface coils are sensitive to the central and anterior regions of the prostate. Gel phantom experiments indicate that the proposed phased-array configuration generates 15 times more signal-to-noise ratio (SNR) than a combination of two surface coils and one endorectal coil within the posterior region of the prostate; the performance of the two configurations is comparable near the anterior prostate surface. Ultimate intrinsic SNR (UISNR) analysis was used to compare the proposed phased array's performance to the best possible SNR for external coils. This analysis showed that the proposed phased array outperforms the best-case external coil within the posterior and central regions of the prostate by up to 20 times. In canine experiments in vivo, high-resolution fast spin-echo (FSE) images of the prostate were obtained with a pixel size of 230 microm obtained in 3 min 12 s. The proposed phased-array design potentially can be used to increase the accuracy of prostate cancer staging and the feasibility of MR-guided prostate interventions.

Animals↗

Intravascular extended sensitivity (IVES) MRI antennas.

The design and application of an intravascular extended sensitivity (IVES) MRI antenna is described. The device is a loopless antenna design that incorporates both an insulating, dielectric coating and a winding of the antenna whip into a helical shape. Because this antenna produces a broad region of high SNR and also allows for imaging near the tip of the device, it is useful for imaging long, luminal structures. To elucidate the design and function of this device, the effects of both insulation and antenna winding were characterized by theoretical and experimental studies. Insulation broadens the longitudinal region over which images can be collected (i.e., along the lumen of a vessel) by increasing the resonant pole length. Antenna winding, conversely, allows for imaging closer to the tip of the antenna by decreasing the resonant pole length. Over a longitudinal region of 20 cm, the IVES imaging antenna described here produces a system SNR of approximately 40,000/r (mL(-1)Hz(1/2)), where r is the radial distance from the antenna axis in centimeters. As opposed to microcoil antenna designs, these antennas do not require exact positioning and allow for imaging over broad tissue regions. While focusing on the design of the IVES antenna, this work also serves to enhance our overall understanding of the properties and behavior of the loopless antenna design.

Animals↗

Real-time imaging of two-dimensional cardiac strain using a harmonic phase magnetic resonance imaging (HARP-MRI) pulse sequence.

The harmonic phase (HARP) method provides automatic and rapid analysis of tagged magnetic resonance (MR) images for quantification and visualization of myocardial strain. In this article, the development and implementation of a pulse sequence that acquires HARP images in real time are described. In this pulse sequence, a CINE sequence of images with 1-1 spatial modulation of magnetization (SPAMM) tags are acquired during each cardiac cycle, alternating between vertical and horizontal tags in successive heartbeats. An incrementing train of imaging RF flip angles is used to compensate for the decay of the harmonic peaks due to both T(1) relaxation and the applied imaging pulses. The magnitude images displaying coarse anatomy are automatically reconstructed and displayed in real time after each heartbeat. HARP strain images are generated offline at a rate of four images per second; real-time processing should be possible with faster algorithms or computers. A comparison of myocardial contractility in non-breath-hold and breath-hold experiments in normal humans is presented.

Adult↗

System for MR image-guided prostate interventions: canine study.

The purpose of this study was to demonstrate the use of a transrectal system that enables precise magnetic resonance (MR) image guidance and monitoring of prostate interventions. The system used a closed-bore 1.5-T MR imaging unit and enables one to take advantage of the higher signal-to-noise ratio achieved with traditional magnet designs, which is crucial for accurate targeting and monitoring of prostate interventions. In the first of the four canine studies, reliable needle placement, with all needles placed within 2 mm of the desired target site, was achieved. In two other studies, MR imaging was used to monitor distribution of injected contrast agent solution (gadopentetate dimeglumine mixed with trypan blue dye) in and around the prostate, thereby confirming that solution had been delivered to the desired tissue and also detecting faulty injections. In the final study, accurate placement and MR imaging of brachytherapy seeds in the prostate were demonstrated. The described system provides a flexible platform for a variety of minimally invasive MR image-guided therapeutic and diagnostic prostate interventions.

Animals↗

Development of an intravascular heating source using an MR imaging guidewire.

PURPOSE: To develop a novel endovascular heating source using a magnetic resonance (MR) imaging guidewire (MRIG) to deliver controlled microwave energy into the target vessel for thermal enhancement of vascular gene transfection. MATERIALS AND METHODS: A 0.032-inch MRIG was connected to a 2.45-GHz microwave generator. We 1) calculated the microwave power loss along the MRIG, 2) simulated the power distribution around the MRIG, 3) measured the temperature increase vs. input power with the MRIG, and 4) evaluated the thermal effect on the balloon-compressed/microwave-heated aorta of six living rabbits. In addition, during balloon inflation, we also simultaneously generated high-resolution MR images of the aortic wall. RESULTS: The power loss was calculated to be 3.9 dB along the MRIG. The simulation-predicted power distribution pattern was cylindrically symmetric, analogous to the geometry of vessels. Under balloon compression, the vessel wall could be locally heated at 41 degrees C with no thermal damage apparent on histology. CONCLUSION: This study demonstrates the possibility of using the MRIG as a multifunctional device, not only as a receiver antenna to generate intravascular high-resolution MR images of atherosclerotic plaques and as a conventional guidewire to guide endovascular interventions during MR imaging, but also as a potential intravascular heating source to produce local heat for thermal enhancement of vascular gene transfection.

Animals↗

Multiple field of view MR fluoroscopy.

This work describes a real-time imaging and visualization technique that allows multiple field of view (FOV) imaging. A stream of images from a single receiver channel can be reconstructed at multiple FOVs within each image frame. Alternately, or in addition, when multiple receiver channels are available, image streams from each channel can be independently reconstructed at multiple FOVs. The implementation described here provides for real-time visualization of the placement of guidewires and catheters on a dynamic roadmap during interventional procedures. The loopless catheter antenna, an electrically active intravascular probe, was used for MR signal reception. In 2D projection images, the catheter and surrounding structures within its diameter of sensitivity appear as bright signal. The simplicity of the resulting images allows very-narrow-FOV imaging to decrease imaging time. Very-narrow-FOV images are acquired on MR receiver channels that collect guidewire or catheter data. These very-narrow-FOV images provide very high frame rate continuous, real-time imaging of the interventional devices (25 fps). Large-FOV images are formed from receiver channels that collect anatomical data from standard imaging surface coils, and simultaneously provide a dynamic, frequently updated roadmap. These multiple-FOV images are displayed together, improving visualization of interventional device placement.

Animals↗

RF safety of wires in interventional MRI: using a safety index.

With the rapid growth of interventional MRI, radiofrequency (RF) heating at the tips of guidewires, catheters, and other wire-shaped devices has become an important safety issue. Previous studies have identified some of the variables that affect the relative magnitude of this heating but none could predict the absolute amount of heating to formulate safety margins. This study presents the first theoretical model of wire tip heating that can accurately predict its absolute value, assuming a straight wire, a homogeneous RF coil, and a wire that does not extend out of the tissue. The local specific absorption rate (SAR) amplification from induced currents on insulated and bare wires was calculated using the method of moments. This SAR gain was combined with a semianalytic solution to the bioheat transfer equation to generate a safety index. The safety index ( degrees C/(W/kg)) is a measure of the in vivo temperature change that can occur with the wire in place, normalized to the SAR of the pulse sequence. This index can be used to set limits on the spatial peak SAR of pulse sequences that are used with the interventional wire. For the case of a straight resonant wire in a tissue with very low perfusion, only about 100 mW/kg/ degrees C spatial peak SAR may be used at 1.5 T. But for < or =10-cm wires with an insulation thickness > or =30% of the wire radius that are placed in well-perfused tissues, normal operating conditions of 4 W/kg spatial peak SAR are possible at 1.5 T. Further model development to include the influence of inhomogeneous RF, curved wires, and wires that extend out of the sample are required to generate safety indices that are applicable to common clinical situations. We propose a simple way to ensure safety when using an interventional wire: set a limit on the SAR of allowable pulse sequences that is a factor of a safety index below the tolerable temperature increase.

Electric Wiring↗

Multifunctional interventional devices for MRI: a combined electrophysiology/MRI catheter.

The design and application of a two-wire electrophysiology (EP) catheter that simultaneously records the intracardiac electrogram and receives the MR signal for active catheter tracking is described. The catheter acts as a long loop receiver, allowing for visualization of the entire catheter length while simultaneously behaving as a traditional two-wire EP catheter, allowing for intracardiac electrogram recording and ablation. The application of the device is demonstrated by simultaneously tracking the catheter and recording the intracardiac electrogram in canine models using 7 and 10 frame/sec real-time imaging sequences. Using solely MR imaging, the entire catheter was visualized and guided from the jugular vein into the cardiac chambers, where the intracardiac electrogram was recorded. By combining several functions in a single, simple structure, the excellent tissue contrast and functional imaging capabilities of MR can be used to improve the efficacy of EP interventions. This catheter will facilitate MR-guided interventions and demonstrates the design of multifunctional interventional devices for use in MRI.

Animals↗

RF heating due to conductive wires during MRI depends on the phase distribution of the transmit field.

In many studies concerning wire heating during MR imaging, a "resonant wire length" that maximizes RF heating is determined. This may lead to the nonintuitive conclusion that adding more wire, so as to avoid this resonant length, will actually improve heating safety. Through a theoretical analysis using the method of moments, we show that this behavior depends on the phase distribution of the RF transmit field. If the RF transmit field has linear phase, with slope equal to the real part of the wavenumber in the tissue, long wires always heat more than short wires. In order to characterize the intrinsic safety of a device without reference to a specific body coil design, this maximum-tip heating phase distribution must be considered. Finally, adjusting the phase distribution of the electric field generated by an RF transmit coil may lead to an "implant-friendly" coil design.

Equipment Design↗

Thermal effect of intravascular MR imaging using an MR imaging-guidewire: an in vivo laboratory and histopathological evaluation.

BACKGROUND: Intravascular magnetic resonance (MR) imaging to guide interventional procedures is a rapidly growing field. A primary concern with these new techniques is their thermal safety. The purpose of this study was to evaluate, in vivo, the thermal effect of an MR imaging-guidewire (MRIG) for intravascular MR imaging (IVMRI). MATERIAL/METHODS: Two indications of potentially adverse local heating were investigated: blood coagulation disorders and pathologic changes in target vessels. Experiments were performed on ten rabbits with a 1.5 T MR scanner. Using a 0.64-mm MRIG as the RF receiver, we imaged the target aorta using a fast spin-echo pulse sequence with an average specific absorption rate (SAR) of 0.6 W/kg. The total MR imaging time was approximately 70 minutes. RESULTS: There were no abnormal value changes of the coagulation factors between pre- and post-IVMRI, no clinical manifestations of blood coagulation disorders, and, histopathologically, no thermal damage in target vessels. CONCLUSIONS: This study demonstrates, from a pathophysiological point of view, the potential safe use of the MR imaging-guidewire for intravascular MR imaging. Further study is required to precisely define the boundaries of these safe operating parameters.

Animals↗

Intravascular MR imaging and intravascular MR-guided interventions.

Intravascular MR technology, using an intravascularly placed MR receiver probe to acquire high-resolution angiographic MR images (i.e. intravascular MR imaging) and to guide cardiovascular interventional therapies (i.e. intravascular MR-guided interventions), is a new, very attractive development in the field of MR imaging. The new technology offers unique advantages for cardiovascular imaging and interventions, including superior contrast capability and multiplanar imaging capabilities without the use of contrast agents and with no risk of ionizing radiation. Thecombination of intravascular MR techniques with other advanced MR imaging techniques, such as functional MR imaging, will open new avenues for the future comprehensive management of cardiovascular atherosclerotic disease. Further improvements in intravascular MR fluoroscopy with true real-time display, analogous to X-ray fluoroscopy, will dramatically establish the role of intravascular MR technology in modern medicine.

Journal Article↗

An interventional magnetic resonance imaging technique for the molecular characterization of intraprostatic dynamic contrast enhancement.

The biological characterization of an individual patient's tumor by noninvasive imaging will have an important role in cancer care and clinical research if the molecular processes that underlie the image data are known. Spatial heterogeneity in the dynamics of magnetic resonance imaging contrast enhancement (DCE-MRI) is hypothesized to reflect variations in tumor angiogenesis. Here we demonstrate the feasibility of precisely colocalizing DCE-MRI data with the genomic and proteomic profiles of underlying biopsy tissue using a novel MRI-guided biopsy technique in a patients with prostate cancer.

Biopsy↗