Distance measurement by circular scanning of the excitation beam in the two-photon microscope.

We developed a method to measure relative distances with nanometer accuracy of fluorescent particles of different color in a two-photon scanning fluorescence microscope, with two-channel photon counting detection. The method can be used in the 10-500 nm range, for distances below the resolution limit of standard far field microscopy. The proposed technique is more efficient than the methods using raster scanning. To achieve maximum sensitivity in the radial direction, the excitation beam is moved periodically in a circular orbit with a radius of the size of the point spread function. The phase and the modulation of the periodic fluorescence signal, calculated by fast Fourier transform, gives the phase and the radial distance of the particle from the center of scanning. The coordinates of particles are recovered simultaneously in the two channels and the relative distance is calculated in real time. Particles can be tracked by moving the center of scanning to the recovered position, while measuring the distance from the second particle. Intensity data are saved and fitted later by a model accounting for light leakage between the channels. The total number of detected photons limited the accuracy of the position and distance measurement. Experiments demonstrating the advantages of the method were performed on fluorescent spheres and single dye molecules immobilized on quartz surface.

Algorithms↗

Polarized fluorescence correlation spectroscopy of DNA-DAPI complexes.

We discuss the use of fluorescence correlation spectroscopy for the measurement of relatively slow rotations of large macromolecules in solution or attached to other macromolecular structures. We present simulations and experimental results to illustrate the range of rotational correlation times and diffusion times that the technique can analyze. In particular, we examine various methods to analyze the polarization fluctuation data. We have found that by first constructing the polarization function and then calculating the autocorrelation function, we can obtain the rotational motion of the molecule with very little interference from the lateral diffusion of the macromolecule, as long as the rotational diffusion is significantly faster than the lateral diffusion. Surprisingly, for common fluorophores the autocorrelation of the polarization function is relatively unaffected by the photon statistics. In our instrument, two-photon excitation is used to define a small volume of illumination where a few molecules are present at any instant of time. The measurements of long DNA molecules labeled with the fluorescent probe DAPI show local rotational motions of the polymers in addition to translation motions of the entire polymer. For smaller molecules such as EGFP, the viscosity of the solution must be increased to bring the relaxation due to rotational motion into the measurable range. Overall, our results show that polarized fluorescence correlation spectroscopy can be used to detect fast and slow rotational motion in the time scale from microsecond to second, a range that cannot be easily reached by conventional fluorescence anisotropy decay methods.

Anisotropy↗

Spatial-temporal studies of membrane dynamics: scanning fluorescence correlation spectroscopy (SFCS).

Giant unilamellar vesicles (GUVs) have been widely used as a model membrane system to study membrane organization, dynamics, and protein-membrane interactions. Most recent studies have relied on imaging methods, which require good contrast for image resolution. Multiple sequential image processing only detects slow components of membrane dynamics. We have developed a new fluorescence correlation spectroscopy (FCS) technique, termed scanning FCS (i.e., SFCS), which performs multiple FCS measurements simultaneously by rapidly directing the excitation laser beam in a uniform (circular) scan across the bilayer of the GUVs in a repetitive fashion. The scan rate is fast compared to the diffusion of the membrane proteins and even small molecules in the GUVs. Scanning FCS outputs a "carpet" of timed fluorescence intensity fluctuations at specific points along the scan. In this study, GUVs were assembled from rat kidney brush border membranes, which included the integral membrane proteins. Scanning FCS measurements on GUVs allowed for a straightforward detection of spatial-temporal interactions between the protein and the membrane based on the diffusion rate of the protein. To test for protein incorporation into the bilayers of the GUVs, antibodies against one specific membrane protein (NaPi II cotransporter) were labeled with ALEXA-488. Fluorescence images of the GUVs in the presence of the labeled antibody showed marginal fluorescence enhancement on the GUV membrane bilayers (poor image contrast and resolution). With the application of scanning FCS, the binding of the antibody to the GUVs was detected directly from the analysis of diffusion rates of the fluorescent antibody. The diffusion coefficient of the antibody bound to NaPi II in the GUVs was approximately 200-fold smaller than that in solution. Scanning FCS provided a simple, quantitative, yet highly sensitive method to study protein-membrane interactions.

Antigen-Antibody Complex↗

Visualizing lipid structure and raft domains in living cells with two-photon microscopy.

The lateral organization of cellular membranes is formed by the clustering of specific lipids, such as cholesterol and sphingolipids, into highly condensed domains (termed lipid rafts). Hence such domains are distinct from the remaining membrane by their lipid structure (liquid-ordered vs. -disordered domains). Here, we directly visualize membrane lipid structure of living cells by using two-photon microscopy. In macrophages, liquid-ordered domains are particularly enriched on membrane protrusions (filopodia), adhesion points and cell-cell contacts and cover 10-15% of the cell surface at 37 degrees C. By deconvoluting the images, we demonstrate the existence of phase separation in vivo. We compare the properties of microscopically visible domains (<1 microm2), with those of isolated detergent-resistant membranes and provide evidence that membrane coverage by lipid rafts and their fluidity are principally governed by cholesterol content, thereby providing strong support for the lipid raft hypothesis.

Animals↗

Absolute frequency-domain pulse oximetry of the brain: methodology and measurements.

A new method to non-invasively measure the absolute tissue oxygen saturation (SO2) and arterial oxygen saturation (fdSaO2) by frequency-domain spectroscopy is described. This method is based on the quantitative measurement of the tissue absorption spectrum, which is used to determine global SO2. From the amplitude of absorption changes caused by arterial pulsation oscillations, in the range of 633-841 nm, the fdSaO2 can be calculated. During deoxygenation (air/N2 mixture) experiments, we measured the fdSaO2 and SO2 on the forehead of three healthy volunteers and compared them to the arterial oxygen saturation measured by conventional pulse oximetry (poSaO2) on the finger. fdSaO2 and poSaO2 agree very well (mean difference: -1.2 +/- 2.6%). Changes in SO2 were systematically smaller than in fdSaO2 or poSaO2 probably due to autoregulation. The measurements with 4 and 8 wavelengths had comparable quality.

Brain↗

Detection of the fast neuronal signal on the motor cortex using functional frequency domain near infrared spectroscopy.

Using non-invasive near infrared spectroscopy fast changes in the range of ms in the optical properties of neurons during brain activity have been described. Since the signal is small, the system to detect it has to be highly noise optimized. We used a frequency-domain tissue oximeter, whose laser diodes were modulated at 110 MHz and the amplitude (AC), mean intensity (DC) and phase (phi) of the modulated optical signal was measured at 96 Hz sample rate. In two volunteers, 36 and 37 years old, the probe consisting of 4 crossed source detector pairs was placed above the motor cortex (C3 position), contralateral to the hand performing the tapping exercise. The tapping frequency was set at 2.5 times the heart rate of the subject to avoid the influence of harmonics on the signal. An electronic device recorded the tapping movement. Control-data were obtained from a solid medium of approximately the same optical properties as the human head. To reduce physiological noise the arterial pulsatility was removed using an adaptive filter, the data was detrended by a high pass filter and a cross correlation function between the optical data and the tapping signal was calculated. The instrumental noise of the control data was very low (AC mean 0.0015% +/- SD 0.00092%, DC 0.00037% +/- 0.00023% and phi 0.00083 degrees +/- 0.00042 degrees). On the head the noise level was AC 0.0042% +/- 0.0031%, DC 0.0021% +/- 0.0012% and phi 0.0020 degrees +/- 0.0017 degrees. In 14 DC, 5 AC and 0 phi out of 30 locations a fast signal was detected, which was higher (p<0.001) than the noise level. This signal disappeared during non-tapping periods. With the signal to noise ratio that we have achieved single subject measurements become feasible.

Animals↗

Mapping of hemodynamics on the human calf with near infrared spectroscopy and the influence of the adipose tissue thickness.

We investigated the influence of the adipose tissue thickness (ATT) on near-infrared spectroscopy (NIRS) measurements of the absorption coefficient (mu a), the reduced scattering coefficient (mu s') and changes in concentrations of oxyhemoglobin ([O2Hb]) and deoxyhemoglobin ([HHb]). We used a frequency domain spectrometer and a special probe to generate maps of these parameters on the human calf during venous occlusion. For ATT below 6 mm mu a remained constant, whereas for ATT between 6 and 14 mm mu a decreased quickly and became almost constant again for ATT larger than 14 mm. Mu s' was not significantly altered by the ATT but the values showed a high variability between subjects. We found significantly different changes in both the [O2Hb] and the [HHb] between the proximal and distal locations of measurement. Although ATT influences the recovery of the optical properties of the underlying tissue, these differences depending on the location cannot be sufficiently explained by the ATT for the following reasons. The ATT varied little within one subject (mean difference 0.88 +/- 1.80 mm). The inter-subject variability was 5 times higher. For a given ATT within one subject we observed different values for changes in [O2Hb] and [HHb] depending on the measurement location. Moreover for a smaller ATT the difference between the values of delta[O2Hb] and delta[HHb] proximal versus distal were more distinct. The thinner the overlying tissue (ATT) the higher is the proportion of muscle tissue in the probed tissue volume. Therefore these differences are most likely coming from the muscle tissue rather than the ATT. This indicates that although the ATT has an evident influence on the measurement of optical parameters and hemodynamics and should therefore be recognized when performing NIRS measurements, other factors will have to be considered as well.

Adipose Tissue↗

High-pressure fluorescence correlation spectroscopy.

We demonstrate that a novel high-pressure cell is suitable for fluorescence correlation spectroscopy (FCS). The pressure cell consists of a single fused silica microcapillary. The cylindrical shape of the capillary leads to refraction of the excitation light, which affects the point spread function of the system. We characterize the influence of these beam distortions by FCS and photon-counting histogram (PCH) analysis and identify the optimal position for fluorescence fluctuation experiments in the capillary. At this position within the capillary, FCS and photon-counting histogram experiments are described by the same equations as used in standard FCS experiments. We report the first experimental realization of fluorescence fluctuation spectroscopy under high pressure. A fluorescent dye was used as a model system for evaluating the properties of the capillary under pressure. The autocorrelation function and the photon count distribution were measured in the pressure range from 0 to 300 MPa. The fluctuation amplitude and the diffusion coefficient show a small pressure dependence. The changes of these parameters, which are on the order of 10%, are due to the pressure changes of the viscosity and the density of the aqueous medium.

Capillary Action↗

The roles of changes in deoxyhemoglobin concentration and regional cerebral blood volume in the fMRI BOLD signal.

To study the behavior of cerebral physiological parameters and to further the understanding of the functional magnetic resonance imaging (fMRI) blood-oxygen-level-dependent (BOLD) effect, multisource frequency-domain near-infrared and BOLD fMRI signals were recorded simultaneously during motor functional activation in humans. From the near-infrared data information was obtained on the changes in cerebral blood volume and oxygenation. To relate our observations to changes in cerebral blood flow the well-known "balloon" model was employed. Our data showed that the deoxyhemoglobin concentration is the major factor determining the time course of the BOLD signal. The increase in cerebral blood oxygenation during functional activation is due to an increase in the velocity of blood flow, and occurs without significant swelling of the blood vessels.

Adolescent↗

Neonatal development of the stratum corneum pH gradient: localization and mechanisms leading to emergence of optimal barrier function.

Although basal permeability barrier function is established at birth, the higher risk for infections, dermatitis, and percutaneous absorption of toxic agents may indicate incomplete permeability barrier maturation in the early neonatal period. Since stratum corneum (SC) acidification in adults is required for normal permeability barrier homeostasis, and lipid processing occurs via acidic pH dependent enzymes, we hypothesized that, in parallel with the less acidic surface pH, newborn SC would exhibit signs of incomplete barrier formation. Fluorescence lifetime imaging reveals that neonatal rat SC acidification first becomes evident by postnatal day 3, in extracellular "microdomains" at the SC- stratum granulosum (SG) interface, where pH-sensitive lipid processing is known to occur. This localized acidification correlated temporally with efficient processing of secreted lamellar body contents to mature extracellular lamellar bilayers. Since expression of the key acidifying mechanism NHE1 is maximal just prior to birth, and gradually declines over the first postnatal week, suboptimal SC acidification at birth cannot be attributed to insufficient NHE1 expression, but could instead reflect reduced NHE1 activity. Expression of the key lipid processing enzyme, beta-glucocerebrosidase (beta-GlcCer'ase), develops similar to NHE1, excluding a lack of beta-GlcCer'ase protein as rate limiting for efficient lipid processing. These results define a postnatal development consisting of initial acidification in the lower SC followed by outward progression, which is accompanied by formation of mature extracellular lamellar membranes. Thus, full barrier competence appears to require the extension of acidification in microdomains from the SC/SG interface outward toward the skin surface in the immediate postnatal period.

Acids↗

Localized irregularities in hemoglobin flow and oxygenation in calf muscle in patients with peripheral vascular disease detected with near-infrared spectrophotometry.

PURPOSE: Near-infrared spectrophotometry is used to measure flow, concentration, and oxygenation of hemoglobin in arterioles, capillaries, and venules several centimeters deep in tissue. The purpose of this study was to investigate the distribution of flow, concentration, and oxygenation of hemoglobin in calf muscle in patients with documented peripheral arterial occlusive disease (PVD), patients with risk factors for PVD,and healthy younger subjects at rest. METHOD: With a frequency-domain near-infrared spectrophotometer and a specially designed probe, we generated maps at 22 locations simultaneously of hemoglobin flow, concentration, and oxygenation, with the venous occlusion method. Eight legs of 7 patients with diagnosed PVD (PVD group), 10 legs of 8 patients with normal ankle-brachial index but with risk factors for PVD (RF group), and 16 legs of 8 healthy subjects (H group) were studied. RESULTS: Global mean values were significantly (P <.05) different between the three groups for oxygen consumption (PVD group, 0.027 +/- 0.009 mL/100 g/min; RF group, 0.038 +/- 0.017 mL/100 g/min; H group, 0.022 +/- 0.020 mL/100 g/min), venous oxygen saturation (PVD, 59.7% +/- 15.4%; RF, 69.6% +/- 10.5%; H, 80.8% +/- 4.5%), and, at 60 s of venous occlusion, concentration changes in oxyhemoglobin (PVD, 4.48 +/- 3.25 micromol/L; RF, 8.44 +/- 2.33 micromol/L; H, 6.85 +/- 4.57 micromol/L), deoxyhemoglobin (PVD, 3.60 +/- 0.73 micromol/L; RF, 4.39 +/- 1.30 micromol/L; H, 2.36 +/- 1.79 micromol/L), and total hemoglobin (PVD, 8.07 +/- 3.83 micromol/L; RF, 12.83 +/- 2.75 micromol/L; H, 9.21 +/- 6.34 micromol/L). No significant difference was found between the three groups for hemoglobin flow (PVD, 0.92 +/- 0.69 micromol/100 mL/min; RF, 1.68 +/- 0.50 micromol/100 mL/min; H, 1.44 +/- 1.17 micromol/100 mL/min) and blood flow (PVD, 0.45 +/- 0.28 mL/100 g/min; RF, 0.77 +/- 0.21 mL/100 g/min; H, 0.62 +/- 0.50 mL/100 g/min). All parameters featured a distribution dependent on location. CONCLUSION: Mean value for venous oxygen saturation was higher in healthy subjects compared to patients with documented PVD. In patients with PVD, areas of lower oxygenation were clearly discernible. At distal locations of calf muscle, significant correlations between reduced hemoglobin flow, venous oxygen saturation, oxyhemoglobin, and total hemoglobin and reduced ankle-brachial index were found. Maps revealed localized irregularities in oxyhemoglobin, total hemoglobin, and venous oxygen saturation in patients with PVD. Near-infrared spectrophotometry is a noninvasive bedside technique that can enable determination of blood flow and oxygenation in tissue and may provide a method for evaluating patients with PVD.

Adult↗

Fast cerebral functional signal in the 100-ms range detected in the visual cortex by frequency-domain near-infrared spectrophotometry.

Brain activity is associated with physiological changes, which alter the optical properties of the tissue in the near-infrared part of the spectrum. Two major types of optical signals following functional brain activation can be distinguished: a slow signal due to hemodynamic changes and a fast signal, which is directly related to neuronal activity. The fast signal is small and therefore difficult to detect. We used a specially noise-optimized frequency-domain near-infrared spectrometer with a pi-sensor, which was expected to be particularly sensitive to deeper tissue layers, to investigate the human visual cortex during visual stimulation generated by a checkerboard. We were able to detect significant fast signals in single light bundles, but not in pi-signals. The fast signals were mostly collocated with strong slow hemodynamic signals, but showed a higher degree of localization than the latter. The latencies of 40 +/- 16 ms of the fast signals were similar between locations. Our results also indicate that the brain responds differently to a single and double (forth and back) reversal of the checkerboard, with a stronger reaction upon the double reversal.

Adult↗

Fluorescence lifetime imaging for the two-photon microscope: time-domain and frequency-domain methods.

Fluorescence lifetime images are obtained with the laser scanning microscope using two methods: the time-correlated single-photon counting method and the frequency-domain method. In the same microscope system, we implement both methods. We perform a comparison of the performance of the two approaches in terms of signal-to-noise ratio (SNR) and the speed of data acquisition. While in our practical implementation the time-correlated single-photon counting technique provides a better SNR for low-intensity images, the frequency-domain method is faster and provides less distortion for bright samples.

Adenylate Kinase↗

Camptothecin poly[n-(2-hydroxypropyl) methacrylamide] copolymers in antitopoisomerase-I tumor therapy: intratumor release and antitumor efficacy.

Soluble copolymers of camptothecin (CPT), based on poly[N-(2-hydroxypropyl) methacrylamide] (pHPMA), were obtained by conjugation through the degradable spacers -Gly-Phe-Leu-Gly- or -Gly-6-aminohexanoyl-Gly-. We investigated to what extent passive accumulation and retention of hydroxypropyl methacrylamide copolymer of CPT (pHPMA-CPT) in tumors and modulation of the drug release influence efficacy. Release of CPT in vivo was detected by time-resolved phase-shift fluorescence imaging on tumor specimens, based on the evidence that free and bound drug had different fluorescence lifetimes in solution. HT-29 murine specimens, obtained at several times after treatment with (3)H-labeled free CPT, pHPMA-Gly-Phe-Leu-Gly-CPT, or pHPMA-Gly-6-aminohexanoyl-Gly-CPT, were either imaged for time-resolved phase-shift fluorescence or subjected to autoradiography. Phase shifts of CPT conjugates were equal or longer than those of free CPT, indicating the presence of both free and polymer-bound drug in the tumor, in agreement with autoradiograms. pHPMA-Gly-Phe-Leu-Gly-CPT underwent relevant intratumor hydrolysis during the first 24 h, whereas the hydrolysis of pHPMA-Gly-6-aminohexanoyl-Gly-CPT was slow. The latter showed antitumor activity at doses from 10 to 22.5 mg/kg/day against s.c. HT-29, A2780, M14, and A549 s.c. xenografts. Moreover, inhibition of tumor growth lasted for up to 73-88 days, and cures were observed on mice with orthotopic implanted HT-29; pHPMA-Gly-Phe-Leu-Gly-CPT was 2-fold more potent than pHPMA-Gly-6-aminohexanoyl-Gly-CPT but less tolerated. Our data suggest that the efficacy of pHPMA-CPT copolymers is related to their intratumor accumulation, and in vivo properties of releasing CPT by esterolytic and proteolytic degradation.

Acrylamides↗

Relationship between erythrocyte membrane phase properties and susceptibility to secretory phospholipase A2.

Normally, cell membranes resist hydrolysis by secretory phospholipase A(2). However, upon elevation of intracellular calcium, the cells become susceptible. Previous investigations demonstrated a possible relationship between changes in lipid order caused by increased calcium and susceptibility to phospholipase A(2). To further explore this relationship, we used temperature as an experimental means of manipulating membrane physical properties. We then compared the response of human erythrocytes to calcium ionophore at various temperatures in the range of 20-50 degrees C using fluorescence spectroscopy and two-photon fluorescence microscopy. The steady state fluorescence emission of the environment-sensitive probe, laurdan, revealed that erythrocyte membrane order decreases systematically with temperature throughout this range, especially between 28 and 45 degrees C. Furthermore, the ability of calcium ionophore to induce increased membrane order and susceptibility to phospholipase A(2) depended similarly on temperature. Both responses to calcium influx were enhanced as membrane fluidity increased. Analysis of the spatial distribution of laurdan fluorescence at several temperatures indicated that the ordering effect of intracellular calcium on fluid membranes generates an increase in the number of fluid-solid boundaries. Hydrolysis of the membrane appeared to progress outward from these boundaries. We conclude that phospholipase A(2) prefers to hydrolyze lipids in fluid regions of human erythrocyte membranes, but primarily when those regions coexist with domains of ordered lipids.

Erythrocyte Membrane↗