Search PubMed⌕ Search

Biomedical subjects

Elsa Lundanes

Publications and source records attributed to Elsa Lundanes.

26 records · Page 2Linked to original sources

Fast and sensitive determination of urinary 1-hydroxypyrene by packed capillary column switching liquid chromatography coupled to micro-electrospray time-of-flight mass spectrometry.

The present work reports capillary liquid chromatographic column switching methodology tailored for fast, sensitive and selective determination of 1-hydroxypyrene (1-OHP) in human urine using micro-electrospray ionization time-of-flight mass spectrometric detection. Samples (100 microl) of deconjugated, water diluted and filtered urine samples were loaded onto a 150 microm I.D.x 30 mm 10 microm Kromasil C(18) pre-column, providing on-line sample clean-up and analyte enrichment, prior to back flushed elution onto a 150 microm I.D.x 100 mm 3.5 microm Kromasil C(18) analytical column. Loading flow rates up to 100 microl/min in addition to the use of isocratic elution by a mobile phase composition of acetonitrile/water (70/30, v/v) containing 5 mM ammonium acetate provided elution of 1-OHP within 5.5 min and a total analysis time of less than 15 min with manual operation. Ionization was performed in the negative mode and 1-OHP was observed as [M-H](-) at m/z 217.08. The method was validated over the concentration range 0.2-40 ng/ml 1-OHP in pre-treated urine, yielding a coefficient of correlation of 0.997. The within-assay (n=6) and between-assay (n=6) precisions were in the range 6.4-7.3 and 7.0-8.1%, respectively, and the recoveries were in the range 96.2-97.5 within the investigated concentration range. The method mass limit of detection was 2 pg, corresponding to a 1-OHP concentration limit of detection of 20 pg/ml (0.09 nmol/l) diluted urine or 0.3 ng/ml (1.35 nmol/l) urine.

Pyrenes↗

The impact of column inner diameter on chromatographic performance in temperature gradient liquid chromatography.

The impact of column inner diameter on chromatographic performance in temperature gradient liquid chromatography has been investigated in the present study. Columns with inner diameters of 0.32, 0.53, 3.2 and 4.6 mm were compared with respect to retention and efficiency characteristics using temperature gradients from 30 to 90 degrees C with temperature ramps of 1, 5, 10 and 20 degrees C min(-1). The columns were all of 15 cm length and were packed with 3 microm Hypersil ODS particles. Alkylbenzenes served as model compounds, and the mobile phase consisted of acetonitrile-water (50:50, v/v). The study revealed that the column ID is not a critical limiting factor when performing temperature programming in LC, at least for columns narrower than 4.6 mm inner diameter in the temperature interval 30-90 degrees C. The retention times for all components on all columns were highly comparable, with similar peak profiles without any signs of peak splitting. The use of mobile phase pre-heating when using the larger bore columns was avoided by starting the temperature gradients close to ambient. However, the relative apparent efficiency was inversely proportional to column inner diameter, making the capillary columns generally more functional towards temperature gradients than the larger bore columns with respect to chromatographic efficiency. In addition, the capillary columns possessed higher robustness towards temperature programming than the conventional columns.

Benzene Derivatives↗

Separation and identification of phosphatidylserine molecular species using reversed-phase high-performance liquid chromatography with evaporative light scattering and mass spectrometric detection.

A reversed-phase HPLC method compatible with evaporative light scattering (ELS) and electrospray mass spectrometric (ES-MS) detection was developed for separation of phosphatidylserine (PS) molecular species. The method was optimised for separation of three disaturated synthetic species: dipalmitoyl glycerophosphoserine, palmitoyl-stearoyl glycerophosphoserine and distearoyl glycerophosphoserine using isocratic elution with a mixture of 2-propanol, tetrahydrofuran and ammonium formate. Baseline separation was obtained on three different columns: one polystyrene/divinylbenzene (PS/DVB) column and two silica based C(18) and C(30) columns. The best chromatographic resolution was achieved with the C(30) column. The limit of detection for DPPS was 5 microg/ml (S/N=3) with ELS detection and 0.1 microg/ml (S/N=3) with negative ion ES-MS in the single ion monitoring mode. Baseline separation of the five main species in a biological PS sample, bovine brain PS, was obtained with the PS/DVB column. Species identification was done by using the retention times of the intact PS species and their corresponding carboxylate anion fragments obtained by in-source fragmentation. Data have shown that individual PS species can be identified by their retention times using direct ELS detection in a mixture of disaturated PS species. However, for the bovine brain PS electrospray-MS detection was necessary for species identification due to the many possible fatty acid combinations in biological PS.

Animals↗

Brominated flame retardants in archived serum samples from Norway: a study on temporal trends and the role of age.

The temporal trends and influence of age and gender on levels of selected brominated flame retardants (BFRs) in human serum have been assessed by analyzing archived samples from Norway. Serum from 40 to 50 year old men collected at six time periods during 1977 to 1999 and from eight groups of differing age and gender sampled in 1998 were pooled into six and eight samples, respectively. The BFRs were isolated using solid-phase extraction (SPE) and the serum lipids decomposed bytreatmentwith concentrated sulfuric acid directly on the polystyrene-divinylbenzene SPE column, prior to elution of the BFRs. Following diazomethane derivatization, the samples were analyzed by gas chromatography-electron capture mass spectrometry. Eight BFRs were quantified in the serum samples: 2,4,4'-tribromodiphenyl ether (BDE-28), 2,2',4,4'-tetrabromodiphenyl ether (BDE-47), 2,2',4,4',5-pentabromodiphenyl ether (BDE-99), 2,2',4,4',6-pentabromodiphenyl ether (BDE-100), 2,2',4,4',5,5'-hexabromodiphenyl ether (BDE-153), 2,2',4,4',5,6'-hexabromodiphenyl ether (BDE-154), 2,4,6-tribromophenol (TriBP), and tetrabromobisphenol A (TBBP-A). The serum concentrations of all the BFRs, increased during the entire period with the exception of TriBP, and the sum of the six polybrominated diphenyl ethers increased from 0.44 ng/g lipids in 1977 to 3.3 ng/g lipids in 1999. The BFR concentrations in the serum from the different age groups were relatively similar, except for the age group 0-4 years, which had 1.6-3.5 times higher serum concentrations. Women older than 25 years had lower serum concentrations of BFRs compared to the corresponding group of men. No trend related to age or gender, nor time during the period 1977 to 1999 was observed for TriBP. The present study indicates an ongoing increase in human exposure to BFRs, and the current body burden appears to be independent of age, except for infants (0-4 years old), who seem to experience elevated exposure.

Adolescent↗

Quantification of lipopolysaccharides in outer membrane vesicle vaccines against meningococcal disease. High-performance liquid chromatographic determination of the constituent 3-hydroxy-lauric acid.

A high-performance liquid chromatographic (HPLC) assay for quantification of lipopolysaccharides (LPSs, endotoxins) in outer membrane vesicle vaccines against meningococcal disease has been developed. The LPS constituent, 3-hydroxy-lauric acid, served as marker substance for the quantification. LPS from the vaccine was precipitated by ethanol and the fatty acid constituents, including 3-hydroxy-lauric acid, were released by acidic hydrolysis, collected and purified by solid phase extraction on C18 disc-cartridges and converted into phenacyl esters for UV detection at 240 nm. Quantification of the derivatized 3-hydroxy-lauric acid was achieved by HPLC using a Brownlee RP-18 reversed phase column with acetonitrile/water (68:32, v/v) as mobile phase. The method was found to be linear over the range 3-49 microg LPS/ml with a sensitivity of 1.6 (microg/ml)(-1). The repeatability (within-day precision) of the method at three levels (3-49 microg LPS/ml) was 6-14% relative standard deviation and the intermediate (between-day) precision was 7% relative standard deviation (at level 15 microg LPS/ml). The method has been successfully used in the quality control of a meningococcal B outer membrane vesicle vaccine, containing 4-8% LPS relative to protein (w/w), in our laboratory for three years.

Bacterial Vaccines↗

Comparing electron ionization high-resolution and electron capture low-resolution mass spectrometric determination of polybrominated diphenyl ethers in plasma, serum and milk.

Gas chromatography coupled to low-resolution mass spectrometry with electron capture negative ionization as detection mode (GC-LRMS (ECNI)) has been compared to gas chromatography coupled to high-resolution mass spectrometry using electron ionization as detection mode (GC-HRMS (EI)) for determination of polybrominated diphenyl ethers (PBDEs) in biological samples. Extracts of 5.0 g plasma, serum and milk samples were analyzed using both methods. The GC-LRMS (ECNI) and GC-HRMS (EI) systems were found to be equally well suited for determination of PBDEs in the biological samples, as well as in standard solutions, with respect to response, detection limits and repeatability at the pg-level. The estimated limits of detection (LOD) in milk extracts ranged from 0.3-0.6 pg PBDE/g milk and 0.4-0.7 pg PBDE/g milk, for the GC-LRMS (ECNI) and GC-HRMS (EI) systems, respectively. The method repeatability including sample preparation was in the range 4.7-8.4% and 0.6-10% relative standard deviation (RSD) for the GC-LRMS (ECNI) and GC-HRMS (EI) systems, respectively.

Calibration↗

Temperature-promoted large-volume solute enrichment in column-switching miniaturized liquid chromatography: determination of an antioxidant.

A two-valve sub-ambient temperature-promoted reversed-phase packed-capillary liquid-chromatography column-switching system has been tailored for sensitive determination of hydrophobic compounds. Such compounds are not easily dissolved in solvent mixtures of non-eluting properties that traditionally are used for solute enrichment in reversed-phase liquid chromatography. Enrichment-column solute focusing of large sample volumes was promoted by use of sub-ambient temperatures only, allowing the use of sample solvents that were stronger or equal to the mobile phase solvent strength. Subsequent column switching and enrichment-column temperature increment provided efficient low-dispersion back-flushed enrichment-column solute desorption onto the analytical column, where the solute was subjected to temperature-programmed gradient action. The antioxidant, Irganox 1076 (octadecyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate) extracted from low density polyethylene with 100% acetonitrile served as a hydrophobic model compound. The mobile phase consisted of acetonitrile containing 10 mM triethylamine and formic acid, and the 0.25 mm id enrichment-column and analytical column in lengths of 27 and 250 mm, respectively, were packed with 3.5 microm Kromasil C18 particles. Sample volumes of up to 500 microL were successfully focused on the enrichment column at 5 degrees C using loading flow rates of up to 40 microL min(-1) prior to temperature programming to 90 degrees C. The concentration limit of detection of Irganox 1076 was 6 ng mL(-1) when using an injection volume of 500 microL. The within-assay precision was in the range 3.5-6.8% (n = 6) while the between-day precision was 7.5% (n = 3) relative standard deviation. The method was linear within the investigated mass range 3-100 ng (R2 = 0.9993).

Antioxidants↗

A new method for determination of halogenated flame retardants in human milk using solid-phase extraction.

A method has been developed for quantitation of a selection of halogenated flame retardants in human milk. The method has been validated for seven polybrominated diphenyl ethers (PBDEs), BDE-28, BDE-47, BDE-99, BDE-100, BDE-153, BDE-154, and BDE-183, and the halogenated phenols 2,4,6-tribromophenol (TriBP), pentabromophenol (PeBP), tetrachlorobisphenol-A (TCBP-A), and tetrabromobisphenol-A (TBBP-A). The sample preparation includes solid-phase extraction using an N-vinylpyrrolidone-divinylbenzene copolymer with on-column lipid decomposition followed by additional cleanup on sulfuric acid-silica columns and methylation of the phenolic compounds. Separation and detection were performed by gas chromatography-electron capture mass spectrometry, using a 5% phenyl 95% dimethylpolysiloxane column. The method has been validated in the range of 1.8-180 pg/g milk for most of the halogenated flame retardants. The average absolute recoveries were from 49 to 83%, and the average recoveries with respect to internal standards were in the range of 53 to 121%. Estimated limits of detection were in the range of 0.3 to 1.0 pg/g milk using a sample size of 5 g for all compounds, except TCBP-A, for which the limit of detection was estimated to 6.7 pg/g milk.

Female↗