Search PubMed⌕ Search

Biomedical subjects

Elizabeth M C Hillman

Publications and source records attributed to Elizabeth M C Hillman.

8 recordsLinked to original sources

Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation.

The cortical hemodynamic response to somatosensory stimulus is investigated at the level of individual vascular compartments using both depth-resolved optical imaging and in-vivo two-photon microscopy. We utilize a new imaging and spatiotemporal analysis approach that exploits the different characteristic dynamics of responding arteries, arterioles, capillaries and veins to isolate their three-dimensional spatial extent within the cortex. This spatial delineation is validated using vascular casts. Temporal delineation is supported by in-vivo two-photon microscopy of the temporal dynamics and vascular mechanisms of the arteriolar and venous responses. Using these techniques we have been able to characterize the roles of the different vascular compartments in generating and controlling the hemodynamic response to somatosensory stimulus. We find that changes in arteriolar total hemoglobin concentration agree well with arteriolar dilation dynamics, which in turn correspond closely with changes in venous blood flow. For 4-s stimuli, we see only small changes in venous hemoglobin concentration, and do not detect measurable dilation or ballooning in the veins. Instead, we see significant evidence of capillary hyperemia. We compare our findings to historical observations of the composite hemodynamic response from other modalities including functional magnetic resonance imaging. Implications of our results are discussed with respect to mathematical models of cortical hemodynamics, and to current theories on the mechanisms underlying neurovascular coupling. We also conclude that our spatiotemporal analysis approach is capable of isolating and localizing signals from the capillary bed local to neuronal activation, and holds promise for improving the specificity of other hemodynamic imaging modalities.

Animals↗

Effective scattering coefficient of the cerebral spinal fluid in adult head models for diffuse optical imaging.

An efficient computation of the time-dependent forward solution for photon transport in a head model is a key capability for performing accurate inversion for functional diffuse optical imaging of the brain. The diffusion approximation to photon transport is much faster to simulate than the physically correct radiative transport equation (RTE); however, it is commonly assumed that scattering lengths must be much smaller than all system dimensions and all absorption lengths for the approximation to be accurate. Neither of these conditions is satisfied in the cerebrospinal fluid (CSF). Since line-of-sight distances in the CSF are small, of the order of a few millimeters, we explore the idea that the CSF scattering coefficient may be modeled by any value from zero up to the order of the typical inverse line-of-sight distance, or approximately 0.3 mm(-1), without significantly altering the calculated detector signals or the partial path lengths relevant for functional measurements. We demonstrate this in detail by using a Monte Carlo simulation of the RTE in a three-dimensional head model based on clinical magnetic resonance imaging data, with realistic optode geometries. Our findings lead us to expect that the diffusion approximation will be valid even in the presence of the CSF, with consequences for faster solution of the inverse problem.

Adult↗

Diffuse optical tomography with spectral constraints and wavelength optimization.

We present an algorithm that explicitly utilizes the wavelength dependence of tissue optical properties for diffuse optical tomography. We have previously shown that the method gives superior separation of absorption and scattering. Here the technique is described and tested in detail, and optimum wavelength sets for a broad range of chromophore combinations are discovered and analyzed.

Algorithms↗

Optimal linear inverse solution with multiple priors in diffuse optical tomography.

A general framework for incorporating single and multiple priors in diffuse optical tomography is described. We explore the use of this framework for simultaneously utilizing spatial and spectral priors in the context of imaging breast cancer. The utilization of magnetic resonance images of water and lipid content as a statistical spatial prior for the diffuse optical image reconstructions is also discussed. Simulations are performed to demonstrate the significant improvement in image quality afforded by combining spatial and spectral priors.

Algorithms↗

Laminar optical tomography: demonstration of millimeter-scale depth-resolved imaging in turbid media.

Laminar optical tomography (LOT) is a new technique that combines the advantages of diffuse optical tomography image reconstruction and a microscopy-based setup to allow noncontact imaging with 100-200-microm resolution effective over depths of 0-2.5 mm. LOT is being developed primarily for multispectral imaging of rat cortex, for which resolving functional dynamics in various layers of the brain's cortex (to depths of 1500 microm) is of increasing interest to neurophysiologists. System design and image reconstruction techniques are described, along with simulation and phantom results that demonstrate the characteristics and limitations of system accuracy and resolution.

Animals↗

Uniqueness and wavelength optimization in continuous-wave multispectral diffuse optical tomography.

We derive conditions for the unique and simultaneous recovery of chromophore concentrations and scattering coefficients in multispectral continuous-wave diffuse optical tomography. These conditions depend strongly on measurement wavelengths. We introduce and demonstrate a general methodology for choosing those wavelengths, which yields superior separation of scattering from absorption and superior separation of one chromophore from another. Application of these concepts should significantly improve the fidelity of continuous-wave diffuse near-infrared optical tomography in tissues.

Computer Simulation↗

Assessment of an in situ temporal calibration method for time-resolved optical tomography.

A 32-channel time-resolved optical imaging device is developed at University College London to produce functional images of the neonatal brain and the female breast. Reconstruction of images using time-resolved measurements of transmitted light requires careful calibration of the temporal characteristics of the measurement system. Since they can often vary over a period of time, it is desirable to evaluate these characteristics immediately after, or prior to, the acquisition of image data. A calibration technique is investigated that is based on the measurement of light back-reflected from the surface of the object being imaged. This is facilitated by coupling each detector channel with an individual source fiber. A Monte Carlo model is employed to investigate the influence of the optical properties of the object on the back-reflected signal. The results of simulations indicate that their influence may be small enough to be ignored in some cases, or could be largely accounted for by a small adjustment to the calibrated data. The effectiveness of the method is briefly demonstrated by imaging a solid object with tissue-equivalent optical properties.

Brain↗

Three-dimensional optical tomography of the premature infant brain.

For the first time, three-dimensional images of the newborn infant brain have been generated using measurements of transmitted light. A 32-channel time-resolved imaging system was employed, and data were acquired using custom-made helmets which couple source fibres and detector bundles to the infant head. Images have been reconstructed using measurements of mean flight time relative to those acquired on a homogeneous reference phantom, and using a head-shaped 3D finite-element-based forward model with an external boundary constrained to match the measured positions of the sources and detectors. Results are presented for a premature infant with a cerebral haemorrhage predominantly located within the left ventricle. Images representing the distribution of absorption at 780 nm and 815 nm reveal an asymmetry consistent with the haemorrhage, and corresponding maps of blood volume and fractional oxygen saturation are generally within expected physiological values.

Brain↗