Acute decrease in renal microvascular PO2 during acute normovolemic hemodilution.

Large differences in the tolerance of organ systems to conditions of decreased O(2) delivery such as hemodilution exist. The kidney receives approximately 25% of the cardiac output and O(2) delivery is in excess of the oxygen demand under normal circumstances. In a rat model of acute normovolemic hemodilution (ANH), we studied the effect of reduced hematocrit on renal regional and microvascular oxygenation. Experiments were performed in 12 anesthetized male Wistar rats. Six animals underwent four steps of ANH (hematocrit 25, 15, 10, and <10%). Six animals served as time-matched controls. Systemic and renal hemodynamic and oxygenation parameters were monitored. Renal cortical (c) and outer medullary (m) microvascular PO(2) (microPO(2)) and the renal venous PO(2) (P(rv)O(2)) were continuously measured by oxygen-dependent quenching of phosphorescence. Despite a significant increase in renal blood flow in the first two steps of ANH, cmicroPO(2) and mmicroPO(2) dropped immediately. From the first step onward oxygen consumption (VO(2(ren))) became dependent on oxygen delivery (DO(2(ren))). With a progressive decrease in hematocrit, a significant correlation between microPO(2) and VO(2(ren)) could be observed, as well as a PO(2) gap between microPO(2) and P(rv)O(2). Furthermore, there was a high correlation between VO(2(ren)) and RBF over a wide range of flows. In conclusion, the oxygen supply to the renal tissue is becoming critical already in an early stage of ANH due to the combination of increased VO(2(ren)), decreased DO(2(ren)), and intrarenal O(2) shunt. This has clinical relevance as recent publications reporting that hemodilution during surgery forms a risk factor for postoperative renal dysfunction.

Animals↗

Influence of fluid resuscitation on renal microvascular PO2 in a normotensive rat model of endotoxemia.

INTRODUCTION: Septic renal failure is often seen in the intensive care unit but its pathogenesis is only partly understood. This study, performed in a normotensive rat model of endotoxemia, tests the hypotheses that endotoxemia impairs renal microvascular PO2 (microPO2) and oxygen consumption (VO2,ren), that endotoxemia is associated with a diminished kidney function, that fluid resuscitation can restore microPO2, VO2,ren and kidney function, and that colloids are more effective than crystalloids. METHODS: Male Wistar rats received a one-hour intravenous infusion of lipopolysaccharide, followed by resuscitation with HES130/0.4 (Voluven), HES200/0.5 (HES-STERIL 6%) or Ringer's lactate. The renal microPO2 in the cortex and medulla and the renal venous PO2 were measured by a recently published phosphorescence lifetime technique. RESULTS: Endotoxemia induced a reduction in renal blood flow and anuria, while the renal microPO2 and VO2,ren remained relatively unchanged. Resuscitation restored renal blood flow, renal oxygen delivery and kidney function to baseline values, and was associated with oxygen redistribution showing different patterns for the different compounds used. HES200/0.5 and Ringer's lactate increased the VO2,ren, in contrast to HES130/0.4. CONCLUSION: The loss of kidney function during endotoxemia could not be explained by an oxygen deficiency. Renal oxygen redistribution could for the first time be demonstrated during fluid resuscitation. HES130/0.4 had no influence on the VO2,ren and restored renal function with the least increase in the amount of renal work.

Animals↗

Mitochondrial PO2 measured by delayed fluorescence of endogenous protoporphyrin IX.

Molecular oxygen is the primary oxidant in biological systems. The ultimate destination of oxygen in vivo is the mitochondria where it is used in oxidative phosphorylation. The ability of this process to produce an amount of high-energy phosphates adequate to sustain life highly depends on the available amount of oxygen. Despite a vast array of techniques to measure oxygen, major (patho)physiological questions remain unanswered because of the unavailability of quantitative techniques to measure mitochondrial oxygen in situ. Here we demonstrate that mitochondrial PO(2) can be directly measured in living cells by harnessing the delayed fluorescence of endogenous protoporphyrin IX (PpIX), thereby providing a technique with the potential for a wide variety of applications. We applied this technique to different cell lines (V-79 Chinese hamster lung fibroblasts, HeLa cells and IMR 32-K1 neuroblastoma cells) and present the first direct measurements of the oxygen gradient between the mitochondria and the extracellular volume.

Animals↗

Dual-wavelength phosphorimetry for determination of cortical and subcortical microvascular oxygenation in rat kidney.

This study presents a dual-wavelength phosphorimeter developed to measure microvascular PO2 (microPO2) in different depths in tissue and demonstrates its use in rat kidney. The used phosphorescent dye is Oxyphor G2 with excitation bands at 440 and 632 nm. The broad spectral gap between the excitation bands combined with a relatively low light absorption of 632 nm light by tissue results in a marked difference in penetration depths of both excitation wavelengths. In rat kidney, we determine the catchments depth of the 440-nm excitation to be 700 microm, whereas the catchments depth of 632 nm is as much as 4 mm. Therefore, the measurements differentiate between cortex and outer medulla, respectively. In vitro, no difference in PO2 readings between both channels was found. On the rat kidney in vivo, the measured cortical microPO2 was on average 20 Torr higher than the medullary microPO2 over a wide PO2 range induced by variations in inspired oxygen fraction. Examples provided from endotoxemia and resuscitation show differences in responses of mean cortical and medullary PO2 readings as well as in the shape of the PO2 histograms. It can be concluded that oxygen-dependent quenching of phosphorescence of Oxyphor G2 allows quantitative measurement of microPO2 noninvasively in two different depths in vivo. Oxygen levels measured by this technique in the rat renal cortex and outer medulla are consistent with previously published values detected by Clark-type oxygen electrodes. Dual-wavelength phosphorimetry is excellently suited for monitoring microPO2 changes in two different anatomical layers under pathophysiological conditions with the characteristics of providing oxygen histograms from two depths and having a penetration depth of several millimeters.

Animals↗

Toward assessment of blood oxygen saturation by spectroscopic optical coherence tomography.

The use of spectroscopic optical coherence tomography to assess hemoglobin oxygen saturation of whole blood is investigated. We propose to use the differential attenuation coefficient to determine the degree of saturation. Our data show qualitative agreement between the measured differential attenuation coefficients as a function of saturation and predictions based on the oxygen-saturation-dependent absorption and scattering properties of blood.

Algorithms↗

Quantitative determination of localized tissue oxygen concentration in vivo by two-photon excitation phosphorescence lifetime measurements.

This study describes the use of two-photon excitation phosphorescence lifetime measurements for quantitative oxygen determination in vivo. Doubling the excitation wavelength of Pd-porphyrin from visible light to the infrared allows for deeper tissue penetration and a more precise and confined selection of the excitation volume due to the nonlinear two-photon effect. By using a focused laser beam from a 1,064-nm Q-switched laser, providing 10-ns pulses of 10 mJ, albumin-bound Pd-porphyrin was effectively excited and oxygen-dependent decay of phosphorescence was observed. In vitro calibration of phosphorescence lifetime vs. oxygen tension was performed. The obtained calibration constants were kq = 356 Torr(-1) x s(-1) (quenching constant) and tau0 = 550 micros (lifetime at zero-oxygen conditions) at 37 degrees C. The phosphorescence intensity showed a squared dependency to the excitation intensity, typical for two-photon excitation. In vivo demonstration of two-photon excitation phosphorescence lifetime measurements is shown by step-wise PO2 measurements through the cortex of rat kidney. It is concluded that quantitative oxygen measurements can be made, both in vitro and in vivo, using two-photon excitation oxygen-dependent quenching of phosphorescence. The use of two-photon excitation has the potential to lead to new applications of the phosphorescence lifetime technique, e.g., noninvasive oxygen scanning in tissue at high spatial resolution. To our knowledge, this is the first report in which two-photon excitation is used in the setting of oxygen-dependent quenching of phosphorescence lifetime measurements.

Animals↗

Oxygen saturation-dependent absorption and scattering of blood.

We report on the scattering properties of oxygenated and deoxygenated whole blood from 250 to 1000 nm. We determine the complex refractive index of oxygenated and deoxygenated hemoglobin using a Kramers-Kronig analysis and optical coherence tomography measurements. Combining these data with Mie theory, the scattering properties are calculated. The strong oxygen saturation dependent scattering effects should be taken into account in the data analysis of optical oxymetry.

Absorption↗

Ratiometric intracellular calcium imaging in the isolated beating rat heart using indo-1 fluorescence.

Abnormalities in intracellular calcium (Ca(i)(2+)) handling have been implicated as the underlying mechanism in a large number of pathologies in the heart. Study into the relation between Ca(i)(2+) behavior and performance of the whole heart function could provide detailed information into the cellular basis of heart function. In this study we describe an optical ratio imaging setup and an analysis method for the beat-to-beat Ca(i)(2+) videofluorescence images of an indo-1 loaded, isolated Tyrode-perfused beating rat heart. The signal-to-noise ratio and the spatiotemporal resolution (with an optimum of 1 ms and 0.6 mm, respectively) made it possible to register different temporal Ca(i)(2+) transients together with left ventricle pressure changes. The Ca(i)(2+) transients showed that Ca(i)(2+) activation propagates horizontally from left to right during sinus rhythm or from the stimulus site during direct left ventricle stimulation. The indo-1 ratiometric video technique developed allows the imaging of ratio changes of Ca(i)(2+) with a high temporal (1 ms) and spatial (0.6 mm) resolution in the isolated Tyrode-perfused beating rat heart.

Animals↗

Light absorption of (oxy-)hemoglobin assessed by spectroscopic optical coherence tomography.

The combination of optical coherence tomography and spectroscopy may allow for highly localized, quantitative measurements of tissue spectral properties. We present, for the first time to our knowledge, quantitative measurements of the absorption coefficients of phantoms and of hemoglobin and oxygenated hemoglobin with spectroscopic optical coherence tomography (SOCT). Our results suggest that SOCT will be able to provide localized, quantitative oxygenation measurements.

Absorption↗

Excitation pulse deconvolution in luminescence lifetime analysis for oxygen measurements in vivo.

Oxygen-dependent quenching of phosphorescence has been proven to be a valuable tool for the measurement of oxygen concentrations both in vitro and in vivo. For biological measurements the relatively long lifetimes of phosphorescence have promoted time-domain-based devices using xenon arc flashlamps as the most common excitation light source. The resulting complex form of the excitation pulse leads to complications in the analysis of phosphorescence lifetimes and ultimately to errors in the recovered pO2 values. Although the problem has been recognized, the consequences on in vivo phosphorescence lifetime measurements have been neglected so far. In this study, the consequences of finite excitation flash duration are analyzed using computer simulations, and a method for the recovery of phosphorescence decay times from complex photometric signals is presented. The analysis provides an explanation as to why different calibration constants are reported in the literature and presents a unified explanation whereby calibration constants are not solely a property of the dye but also of the measuring device. It is concluded that complex excitation pulse patterns without appropriate analysis methods lead to device-specific calibration constants and nonlinearity and can be a potent source of errors when applied in vivo. The method of analysis presented in this article allows reliable phosphorescence lifetime measurements to be made for oxygen pressure measurements and can easily be applied to existing phosphorimeters.

Algorithms↗