Search PubMed⌕ Search

Biomedical subjects

Edward A H Mallen

Publications and source records attributed to Edward A H Mallen.

10 recordsLinked to original sources

Coherence function analysis of the higher-order aberrations of the human eye.

We measured the wavefront aberrations of the eyes of five subjects with a Shack-Hartmann sensor sampling at 21.2 Hz and decomposed the measurements into Zernike aberration terms up to and including the fifth radial order. Coherence function analysis was used to determine the common frequency components between the aberrations within subjects. We found the results to be highly subject dependent. The coherence values were typically <0.4. Possible reasons for this are discussed. Coherence function analysis is a useful tool that can be used in future investigations to determine correlations between the aberration dynamics of the eye and other physiological mechanisms.

Adult↗

Refractive group differences in accommodation microfluctuations with changing accommodation stimulus.

PURPOSE: Microfluctuations of accommodation are known to increase in magnitude with increasing accommodation stimulus. Reduced sensitivity to blur in myopic subjects could also lead to increases in the magnitude of the microfluctuations. The aim of this study is to examine the effect of variations in accommodation stimulus upon the microfluctuations in different refractive groups. METHODS: Thirty-six subjects were divided into three groups depending upon their refractive error and age of onset of their myopia; 12 emmetropes (EMMs), 12 early onset myopes (EOMs) and 12 late-onset myopes (LOMs). Steady-state accommodation responses were recorded continuously for 2 min using the Shin-Nippon SRW-5000 autorefractor at a sampling rate of 52 Hz while viewing targets at accommodation stimuli levels of 0, 1, 2, 3 and 4 D in a Badal (+5 D) optical system. RESULTS: The EMMs and EOMs showed systematic increases in the root mean square (r.m.s.) value of the microfluctuations with increasing accommodation stimulus. In contrast, no systematic variation with accommodation stimulus was found for the LOMs. Power spectrum analysis demonstrated that increases in the size of the microfluctuations were mediated by increases in the power of the low frequency components of the accommodation response. CONCLUSIONS: The magnitude of the microfluctuations in the EMMs and EOMs may be influenced primarily by accommodation response-induced zonular relaxation effects or to changes in the physical properties of the accommodation plant with increasing accommodation response. The LOMs may have an increased baseline neural blur threshold, which appears to modulate the magnitude of the accommodative microfluctuations for low accommodation levels. At higher accommodation demands, the changes in the physical properties of the accommodation plant or the zonular relaxation effects appear to exceed the blur threshold, and the known association between microfluctuations and accommodation stimulus level is restored.

Accommodation, Ocular↗

Clinical evaluation of rebound tonometer.

PURPOSE: To evaluate the reliability and repeatability of intraocular pressure (IOP) measurements using a new rebound tonometer. METHODS: Intraocular pressure was measured in 42 healthy human eyes of subjects aged 18-30 years (mean +/- standard deviation [SD] 21.5 +/- 3.2 years) using the ICare Rebound and Goldmann tonometers in two separate sessions. RESULTS: Intraocular pressure measurements were found to read slightly, but not significantly, higher with the ICare tonometer compared with the Goldmann instrument in both sessions (first session: mean bias +/- SD + 0.50 +/- 2.33 mmHg; second session: mean bias +/- SD + 0.52 +/- 1.92 mmHg). Limits of agreement between repeated readings were +/- 5.11 mmHg for measurements taken with the ICare tonometer, compared with +/- 3.15 mmHg for measurements taken with the Goldmann method. CONCLUSION: Measurement of IOP in normal, healthy subjects using the ICare rebound tonometer produced a small, statistically insignificant, positive bias when compared with the Goldmann tonometer. Intersessional repeatability of IOP taken with the ICare is poorer than that of IOP taken with the Goldmann tonometer, but is comparable with that of other non-Goldman-type tonometers currently available.

Adolescent↗

Transient Axial Length Change during the Accommodation Response in Young Adults.

PURPOSE: To measure the degree of transient axial elongation during the accommodation response in emmetropic and myopic young adults. To evaluate the effect of refractive error and accommodative demand on transient axial elongation of the eye. METHODS: Axial length of the right eye was measured in 30 emmetropes and 30 myopes, by using the IOLMaster (Carl Zeiss Meditec, Inc., Dublin, CA), while accommodative stimuli of 0, 2, 4 and 6 D were presented with a Badal optometer. RESULTS: Axial length increased in both emmetropic and myopic subjects during short periods of accommodative stimulation. Greater transient increases in axial length were observed in myopic than in emmetropic subjects. The mean axial elongation with a 6-D stimulus to accommodation was 0.037 mm in emmetropes and 0.058 mm in myopes (P = 0.02). The degree of transient axial elongation correlated well with the stimulus to accommodation in emmetropes and myopes. Anterior chamber depth decreased, on average, by 0.19 mm in emmetropes and 0.18 mm in myopes when observing a 6-D stimulus to accommodation. CONCLUSIONS: During relatively short periods of accommodative stimulation, axial length increases in both emmetropic and myopic young adults. At higher levels of accommodative stimulation, a significantly greater transient increase in axial length is observed in myopic subjects than in their emmetropic counterparts.

Accommodation, Ocular↗

Adaptive optics system for investigation of the effect of the aberration dynamics of the human eye on steady-state accommodation control.

It is now known that defocus is not the only aberration in the eye that exhibits dynamic behavior during fixation. It is currently unknown what effects, if any, the dynamics of these other aberrations have on steady-state accommodation control. We constructed an adaptive optics system to serve as a tool for future investigations in this area. The system has several design features of interest, including automated precompensation of defocus and astigmatism and a method to bypass a scanner used to reduce speckle. It also has the facility to measure the eye's aberrations independent of the aberration manipulation device-a 37-actuator membrane deformable mirror. Coherence function analysis was used to assess the deformable mirror performance in terms of coupling between Zernike modes. Modes beyond third radial order showed severe coupling. Pilot data were collected on one subject to demonstrate the utility of this system in steady-state accommodation studies. The value of the system for future work in this area is discussed.

Accommodation, Ocular↗

Sympathetic innervation of ciliary muscle and oculomotor function in emmetropic and myopic young adults.

PURPOSE: Evidence exists for an additional inhibitory accommodative control system mediated by the sympathetic branch of the autonomic nervous system (ANS). This work aims to show the relative prevalence of sympathetic inhibition in young emmetropic and myopic adults, and to evaluate the effect of sympathetic facility on accommodative and oculomotor function. METHODS: Profiling of ciliary muscle innervation was carried out in 58 young adult subjects (30 emmetropes, 14 early onset myopes, 14 late onset myopes) by examining post-task open-loop accommodation responses, recorded continuously by a modified open-view infrared optometer. Measurements of amplitude of accommodation, tonic accommodation, accommodative lag at near, AC/A ratio, and heterophoria at distance and near were made to establish a profile of oculomotor function. RESULTS: Evidence of sympathetic inhibitory facility in ciliary smooth muscle was observed in 27% of emmetropes, 21% of early-onset myopes and 29% of late-onset myopes. Twenty-six percent of all subjects demonstrated access to sympathetic facility. Closed-loop oculomotor function did not differ significantly between subjects with sympathetic facility, and those with sympathetic deficit. CONCLUSIONS: Emmetropic and myopic groups cannot be distinguished in terms of the relative proportions having access to sympathetic inhibition. Presence of sympathetic innervation does not have a significant effect on accommodative function under closed-loop viewing conditions.

Accommodation, Ocular↗

Ametropia and ocular biometry in a U.K. university student population.

PURPOSE: The prevalence of myopia is known to vary with age, ethnicity, level of education, and socioeconomic status, with a high prevalence reported in university students and in people from East Asian countries. This study determines the prevalence of ametropia in a mixed ethnicity U.K. university student population and compares associated ocular biometric measures. METHODS: Refractive error and related ocular component data were collected on 373 first-year U.K. undergraduate students (mean age = 19.55 years +/- 2.99, range = 17-30 years) at the start of the academic year at Aston University, Birmingham, and the University of Bradford, West Yorkshire. The ethnic variation of the students was as follows: white 38.9%, British Asian 58.2%, Chinese 2.1%, and black 0.8%. Noncycloplegic refractive error was measured with an infrared open-field autorefractor, the Shin-Nippon NVision-K 5001 (Shin Nippon, Ryusyo Industrial Co. Ltd, Osaka, Japan). Myopia was defined as a mean spherical equivalent (MSE) less than or equal to -0.50 D. Hyperopia was defined as an MSE greater than or equal to +0.50 D. Axial length, corneal curvature, and anterior chamber depth were measured using the Zeiss IOLMaster (Carl Zeiss, Jena, GmBH). RESULTS: The analysis was carried out only for white and British Asian groups. The overall distribution of refractive error exhibited leptokurtosis, and prevalence levels were similar for white and British Asian (the predominant ethnic group) students across each ametropic group: myopia (50% vs. 53.4%), hyperopia (18.8% vs. 17.3%), and emmetropia (31.2% vs. 29.3%). There were no significant differences in the distribution of ametropia and biometric components between white and British Asian samples. CONCLUSION: The absence of a significant difference in refractive error and ocular components between white and British Asian students exposed to the same educational system is of interest. However, it is clear that a further study incorporating formal epidemiologic methods of analysis is required to address adequately the recent proposal that juvenile myopia develops principally from "myopiagenic" environments and is relatively independent of ethnicity.

Adolescent↗

Non-invasive phakometric measurement of corneal and crystalline lens alignment in human eyes.

We describe a non-invasive phakometric method for determining corneal axis rotation relative to the visual axis (beta) together with crystalline lens axis tilt (alpha) and decentration (d) relative to the corneal axis. This does not require corneal contact A-scan ultrasonography for the measurement of intraocular surface separations. Theoretical inherent errors of the method, evaluated by ray tracing through schematic eyes incorporating the full range of human ocular component variations, were found to be larger than the measurement errors (beta < 0.67 degrees , alpha < 0.72 degrees and d < 0.08 mm) observed in nine human eyes with known ocular component dimensions. Intersubject variations (mean +/- S.D.: beta = 6.2 +/- 3.4 degrees temporal, alpha = 0.2 +/- 1.8 degrees temporal and d = 0.1 +/- 0.1 mm temporal) and repeatability (1.96 x S.D. of difference between repeat readings: beta +/- 2.0 degrees , alpha +/- 1.8 degrees and d +/- 0.2 mm) were studied by measuring the left eyes of 45 subjects (aged 18-42 years, 29 females and 16 males, 15 Caucasians, 29 Indian Asians, one African, refractive error range -7.25 to +1.25 D mean spherical equivalent) on two occasions.

Adolescent↗

Refractive error and ocular biometry in Jordanian adults.

The aim of this study was to establish the prevalence of refractive errors in Jordanian adults of working age, and to study the ocular biometric correlates of refractive error in this population. Refractive error and ocular biometry were measured in 1093 Jordanian adult subjects aged 17-40 years to determine the prevalence of refractive error, and explore structural correlations of ametropia. Refractive error was measured using a Grand-Seiko GR-3100K closed-view infrared autorefractor. Ocular component measurements were made using A-scan ultrasonography and autokeratometry. The prevalence of myopia [spherical equivalent refraction (SER) less than -0.50 DS] and hyperopia (SER greater than +0.50 DS) was 53.71 and 5.67% respectively; 40.62% of the sample was emmetropic (refraction between +0.50 D and -0.50 D inclusive in both principal meridians). The distribution of SER was found to show marked leptokurtosis, exhibiting a peak between plano and 1 D of myopia. Corneal radius, anterior chamber depth, crystalline lens thickness, vitreous chamber depth and axial length (AL) parameters were normally distributed in the population studied. AL to corneal curvature ratio was not normally distributed, and showed marked leptokurtosis. Linear regression analysis showed that AL correlated most closely with spherical equivalent refractive error. This study has established a database of refractive error prevalence and ocular biometric correlates of ametropia in a Middle Eastern population of working age.

Adolescent↗

Refractive error, cognitive demand and nearwork-induced transient myopia.

PURPOSE: Whereas many previous studies have identified the association between sustained near work and myopia, few have assessed the influence of concomitant levels of cognitive effort. This study investigates the effect of cognitive effort on near-work induced transient myopia (NITM). METHODS: Subjects comprised of six early onset myopes (EOM; mean age 23.7 yrs; mean onset 10.8 yrs), six late-onset myopes (LOM; mean age 23.2 yrs; mean onset 20.0 yrs) and six emmetropes (EMM; mean age 23.8 yrs). Dynamic, monocular, ocular accommodation was measured with the Shin-Nippon SRW-5000 autorefractor. Subjects engaged passively or actively in a 5 minute arithmetic sum checking task presented monocularly on an LCD monitor via a Badal optical system. In all conditions the task was initially located at near (4.50 D) and immediately following the task instantaneously changed to far (0.00 D) for a further 5 minutes. The combinations of active (A) and passive (P) cognition were randomly allocated as P:P; A:P; A:A; P:A. RESULTS: For the initial near task, LOMs were shown to have a significantly less accurate accommodative response than either EOMs or EMMs (p < 0.001). For the far task, post hoc analyses for refraction identified EOMs as demonstrating significant NITM compared to LOMs (p < 0.05), who in turn showed greater NITM than EMMs (p < 0.001). The data show that for EOMs the level of cognitive activity operating during the near and far tasks determines the persistence of NITM; persistence being maximal when active cognition at near is followed by passive cognition at far. CONCLUSIONS: Compared with EMMs, EOMs and LOMs are particularly susceptible to NITM such that sustained near vision reduces subsequent accommodative accuracy for far vision. It is speculated that the marked NITM found in EOM may be a consequence of the crystalline lens thinning shown to be a developmental feature of EOM. Whereas the role of small amounts of retinal defocus in myopigenesis remains equivocal, the results show that account needs to be taken of cognitive demand in assessing phenomena such as NITM.

Accommodation, Ocular↗