Search PubMed⌕ Search

Biomedical subjects

Eduardo A Lima

Publications and source records attributed to Eduardo A Lima.

2 recordsLinked to original sources

Thin-film IrOx pH microelectrode for microfluidic-based microsystems.

Microsensors are valuable tools to monitor cell metabolism in cell culture volumes. The present research describes the fabrication and characterization of on-chip thin-film iridium oxide pH microsensors with dimensions of 20 microm x 20 microm and 20 microm x 40 microm suitable to be incorporated into nl volumes. IrOx thin films were formed on platinum microelectrodes by electrochemical deposition in galvanostatic mode. Anodically grown iridium oxide films showed a near super-Nernstian response with a slope of -77.6+/-2 mV/pH at 22 degrees C, and linear responses within the pH range of 4-11. Freshly deposited electrodes showed response times as low as 6s. Long-term studies showed a baseline drift of 2-3 mV/month, which could easily be compensated by calibration. This work demonstrated for the first time the use of planar IrOx pH microelectrodes to measure the acidification rate of CHO and fibroblast cells in an on chip cell culture volume of 25 nl with microfluidic control.

Animals↗

A microfluidic device to confine a single cardiac myocyte in a sub-nanoliter volume on planar microelectrodes for extracellular potential recordings.

A hybrid chip is described which combines a microfluidic network fabricated in a silicone elastomer (PDMS) with planar microelectrodes. It was used to measure extracellular potentials from single adult murine cardiac myocytes in a restricted extracellular space. The recorded variations in the extracellular potentials were caused by transmembrane currents associated with spontaneously initiated intracellular calcium waves. Single cells were trapped inside the 100 pl microchamber by pressure gradients and maintained for several hours by continuous perfusion. In addition, the localized delivery of drugs to a portion of the cell was demonstrated. The impedance of the electrodes was reduced by a factor of 10 to 20 after the electrodeposition of platinum black. Biopotentials recorded from single cells with platinum black electrodes showed a three-fold decrease in the noise, resulting in a maximum signal-to-noise ratio of 15:1. Characteristic variations in the frequency and shape of the extracellular potentials were observed among different cells which are most likely due to differences in the sarcoplasmic reticulum Ca(2+) load. Our device architecture permits the integration of electrochemical and optical sensors for multiparameter recordings.

Animals↗