Optical Coherence Tomography (OCT). Potential of a new high-resolution intracoronary imaging technique.

BACKGROUND: It is believed that most myocardial infarctions result from the rupture of "vulnerable plaques", that share certain common characteristics. These plaques typically consist of a lipid-rich core in the central portion of the thickened intima, covered by a thin friable fibrous cap. Today, one of the important challenges in the field of interventional cardiology is how to identify minor or silent plaques that carry the risk of thrombosis resulting in severe cardiac events. Current imaging technologies lack the resolution to reliably identify these lesions. OCT: Optical Coherence Tomography (OCT) might have the potential to fill this role. OCT is a new non-contact, light-based imaging modality providing in situ images of tissues at near histologic resolution. As shown in various preclinical and clinical reports, OCT allows the identification of mural as well as luminal morphologies including lumen dimensions, plaques, thrombi, dissections, tissue flaps as well as information on stent geometries including apposition and symmetry. Trials comparing intravascular ultrasound (IVUS) and OCT demonstrated that OCT provided additional morphologic information, which could be used to improve plaque characterization. CONCLUSION: OCT has the potential to provide a new and more detailed look into the vessel wall, which might help to identify plaques that are at risk of rupture, and furthermore, which will influence and guide the appropriate patient-specific therapeutic approach.

Coronary Artery Disease↗

Direct stent implantation using the EXPRESS Coronary Stent System: results of a multi-center feasibility study.

The aim of this prospective, multicenter, single arm study was to assess the safety and feasibility of EXPRESS Coronary Stent implantation in native coronary arteries without balloon predilatation. Forty-two patients with de novo or restenotic lesions were enrolled, of which 38 were eligible for analysis. The coronary lesions were predominantly complex, occurring in arteries with a mean reference diameter of 2.80 +/- 0.49 mm. Technical and procedural success were achieved in 89.5% and 84% of the cases respectively. The mean minimal lumen diameter increased from 1.08 +/- 0.26 mm to 2.55 +/- 0.44 mm and diameter stenosis decreased from 61 +/- 7% to 13 +/- 8%. The primary endpoint of major adverse cardiac events at 30 days was 2.6% and was limited to only one event (target vessel revascularization, nontarget lesion). No other MACE were observed during the three-month follow-up period. Based on the findings of this study, direct stenting with the EXPRESS Stent appears feasible and is well tolerated.

Aged↗

Induction of mild systemic hypothermia with endovascular cooling during primary percutaneous coronary intervention for acute myocardial infarction.

OBJECTIVES: The purpose of this study was to evaluate the safety and feasibility of endovascular cooling during primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI). BACKGROUND: In experimental models of AMI, mild systemic hypothermia has been shown to reduce metabolic demand and limit infarct size. METHODS: In a multi-center study, 42 patients with AMI (<6 h from symptom onset) were randomized to primary PCI with or without endovascular cooling (target core temperature 33 degrees C). Cooling was maintained for 3 h after reperfusion. Skin warming, oral buspirone, and intravenous meperidine were used to reduce the shivering threshold. The primary end point was major adverse cardiac events at 30 days. Infarct size at 30 days was measured using (99m)Tc-sestamibi SPECT imaging. RESULTS: Endovascular cooling was performed successfully in 20 patients (95%). All achieved a core temperature below 34 degrees C (mean target temperature 33.2 +/- 0.9 degrees C). The mean temperature at reperfusion was 34.7 +/- 0.9 degrees C. Cooling was well tolerated, with no hemodynamic instability or increase in arrhythmia. Nine patients experienced mild episodic shivering. Major adverse cardiac events occurred in 0% vs. 10% (p = NS) of treated versus control patients. The median infarct size was non-significantly smaller in patients who received cooling compared with the control group (2% vs. 8% of the left ventricle, p = 0.80). CONCLUSIONS: Endovascular cooling can be performed safely as an adjunct to primary PCI for AMI. Further clinical trials are required to determine whether induction of mild systemic hypothermia with endovascular cooling will limit infarct size in patients undergoing reperfusion therapy.

Adult↗

7-hexanoyltaxol-eluting stent for prevention of neointimal growth: an intravascular ultrasound analysis from the Study to COmpare REstenosis rate between QueST and QuaDS-QP2 (SCORE).

BACKGROUND: Inhibition of neointimal tissue growth has been demonstrated in preliminary human feasibility studies with a stent-based polymer sleeve delivering 7-hexanoyltaxol. The Study to COmpare REstenosis rate between QueST and QuaDS-QP2 (SCORE) trial is a human, randomized, multicenter trial comparing 7-hexanoyltaxol (QP2)-eluting stents (qDES) with bare metal stents (BMS) in the treatment of de novo coronary lesions. The purpose of this substudy was to evaluate the acute expansion property and long-term neointimal responses of qDES compared with BMS as assessed by intravascular ultrasound (IVUS). METHODS AND RESULTS: A total of 122 (qDES 66, BMS 56) patients were enrolled into the IVUS substudy. All IVUS images (immediately after the procedure and at 6-month follow-up) were analyzed at an independent core laboratory in a blind manner. At baseline, qDES achieved stent expansion similar to BMS. At follow-up, qDES showed reduced neointimal growth by 70% at the tightest cross section and by 68% over the stented segment (P<0.0001 for both), resulting in a significantly larger lumen in qDES than in BMS. Unlike intracoronary brachytherapy, there was no evidence of negative edge effects, unhealed dissections, or late stent-vessel wall malapposition over the stented and adjacent references segments in either group. CONCLUSIONS: Detailed IVUS analysis revealed that qDES had comparable acute mechanical and superior long-term biological effects to BMS. Although the long-term benefits and limitations of this technology require further investigation, the reduction in neointimal thickenings demonstrated that local delivery of 7-hexanoyltaxol through polymer sleeves augments conventional mechanical treatment of atherosclerotic disease.

Blood Vessel Prosthesis Implantation↗

Relation of stent design and stent surface material to subsequent in-stent intimal hyperplasia in coronary arteries determined by intravascular ultrasound.

A variety of different stent designs and coatings have become available. This study sought to determine the impact of stent design and gold-coating of stents on intimal hyperplasia (IH) in human atherosclerotic coronary arteries in relation to known predictors of restenosis. Angiographic and intravascular ultrasound (IVUS) studies were performed at 6-month follow-up on 311 native coronary lesions of 311 patients treated with 99 Multi-Link stents, 74 InFlow steel stents, 73 InFlow gold-coated stents, 41 Palmaz-Schatz stents, 12 NIR steel stents, and 12 gold-coated NIR Royal stents. Lumen and stent cross-sectional area (CSA) were measured at 1-mm axial increments. Mean IH CSA (stent CSA - lumen CSA) and mean IH thickness were calculated and averaged over the total stent length. IVUS demonstrated different levels of IH for the 6 stents. Mean IH thickness ranged from 0.20 +/- 0.13 mm for Multi-Link stents to 0.43 +/- 0.14 mm for InFlow goal-coated stents (p <0.001). Multivariate analysis proved non-Multi-Link stent design (odds ratio 3.45, 95% confidence intervals 1.13 to 11.11, p <0.034) and gold coating (odds ratio 3.78, 95% confidence intervals 1.88 to 7.54, p <0.001) to be the only independent predictors of IH thickness >0.3 mm. In conclusion, stent design and surface material have an important impact on the IH response to stents implanted in human coronary arteries. However, the differences in IH thickness between the analyzed stents were relatively small compared with the absolute lumen dimensions.

Analysis of Variance↗

Evaluation of a balloon occlusion and aspiration system for protection from distal embolization during stenting in saphenous vein grafts.

Distal embolization after angioplasty in degenerated saphenous vein grafts (SVGs) results in high rates of periprocedural myonecrosis and mortality. Temporary protection of the distal microcirculation with aspiration of dislodged debris may improve the safety of SVG intervention. To evaluate the feasibility, safety, and efficacy of distal protection using the PercuSurge GuardWire Occlusion and Aspiration System, 103 consecutive patients undergoing planned stenting of 105 SVG lesions were prospectively enrolled in a multinational, multicenter study. Before angioplasty, protection of the distal circulation was achieved with the PercuSurge GuardWire distal balloon occlusion system, followed by stenting and debris aspiration. Quality assurance measures in the study included independent on-site data monitoring, clinical event adjudication, data analysis, and use of multiple core laboratories. Mean graft age was 8.9 +/- 4.0 years. The duration of distal balloon inflation was 5.4 +/- 3.7 minutes; premature balloon deflation for ischemia was not required in any patient. Macroscopically visible red and/or yellow debris was extracted in 91% of patients. By core lab analysis, postprocedural Thrombolysis In Myocardial Infarction-III flow was present in 98.9% of grafts (vs 83.5% before intervention). No patient developed angiographic evidence of no reflow or distal embolization. Postprocedural creatine phosphokinase MB isozyme levels were elevated to >3 x normal in only 5 patients (5%), and 97 patients (94%) were free of major adverse events at 30 days. We conclude that the GuardWire distal balloon occlusion and aspiration system is an effective and safe method for protecting distal microcirculation from the adverse consequences of embolization during mechanical intervention of degenerated SVGs.

Aged↗

Effects of gold coating of coronary stents on neointimal proliferation following stent implantation.

Experimental studies suggest a reduced neointimal tissue proliferation in vascular stainless steel stents coated with gold. This prospective multicenter trial evaluated the impact of gold coating on neointimal tissue proliferation in patients undergoing elective stent implantation. The primary end point was the in-stent tissue proliferation measured by intravascular ultrasound at 6 months comparing stents of identical design with or without gold coating (Inflow). Two hundred four patients were randomized to receive uncoated (group A, n = 101) or coated (group B, n = 103) stents. Baseline parameters did not differ between the groups. Stent length and balloon size were comparable, whereas inflation pressure was slightly higher in group A (14 +/- 3 vs 13 +/- 3 atm, p = 0.013). Procedural success was similar (A, 97%; B, 96%). The acute angiographic result was better for group B (remaining stenosis 4 +/- 12% vs 10 +/- 11%, p = 0.002). Six-month examinations revealed more neointimal proliferation in group B. By ultrasound, the neointimal volume within the stent was 47 +/- 25 versus 41 +/- 23 mm(3) (p = 0.04), with a ratio of neointimal volume-to-stent volume of 0.45 +/- 0.12 versus 0.40 +/- 0.12 (p = 0.003). The angiographic minimal luminal diameter was smaller in group B (1.47 +/- 0.57 vs 1.69 +/- 0.70 mm, p = 0.04), with a higher late luminal loss of 1.17 +/- 0.51 versus 0.82 +/- 0.56 mm (p = 0.001). Thus, gold coating of the tested stent type resulted in more neointimal tissue proliferation.

Aged↗

Results of the Jostent coronary stent graft implantation in various clinical settings: procedural and follow-up results.

The Jostent coronary stent graft (CSG) is composed of a PTFE layer sandwiched between two stainless steel stents, initially introduced for the treatment of coronary perforations and aneurysms with excellent results. By providing a mechanical barrier, this stent design also may be beneficial in the treatment of complex ulcerated lesions and in-stent restenosis by preventing debris protrusion and neointimal proliferation through the stent struts. To evaluate the safety and efficacy of this stent graft, we implanted 78 CSGs in 70 patients for a broad range of indications, including coronary perforations, aneurysms, degenerated saphenous vein grafts, complex lesions, and in-stent restenosis. The primary angiographic success rate (95.9%) was high, and using intravascular ultrasound (IVUS) guidance during stent implantation and high inflation pressures (19.3 +/- 3.2 atm), stent expansion with optimal symmetry was achieved in 94.7%. One limitation of the Jostent CSG was the side-branch occlusion rate (18.6%) and the resulting non-Q-wave infarction rate in seven cases (mean CK elevation, 238 U/l), acute Q-wave MI in two cases, and transient ventricular fibrillation in one patient after occlusion of the proximal RCA side branch without further complications. Subacute stent thrombosis occurred in four cases (5.7%) 7 to 70 days after stent implantation, despite using combined antiplatelet therapy with aspirin (ASA), ticlopidine, and/or clopidogrel for 30 days. Angiographic follow-up was available in 56 patients (80.0%) after a mean of 159 +/- 49 days, and follow-up IVUS was available in 38 cases. The overall restenosis rate (> 50% diameter stenosis) was 31.6% manifest primarily as edge restenosis (29.8% stent edge vs. 8.8% stent center; P < 0.001). IVUS examinations showed a minimal late lumen loss of 0.4 +/- 2.2 mm(2) within the center of the stent graft vs. 3.2 +/- 2.3 mm(2) at the stent edges (P < 0.001). The restenosis rate in the prespecified subgroups was 33.3% for saphenous vein grafts (2/6 lesions), 30.0% in complex lesions (6/20 lesions), and 38.5% (10/26 lesions) for the treatment of in-stent restenosis. Implantation of the Jostent CSG is feasible and safe, even in complex lesion subsets, and is associated with high primary success rates provided major side branches are avoided. The use of this stent may require an extended time course of antiplatelet therapy. Frequent focal stent edge renarrowing influences the overall restenosis rate. However, in treatment of complex in-stent restenosis and vein graft lesions, stent grafts may offer benefit over conventional therapies. Covered stents such as the JoMed coronary stent graft may become essential for bailout treatment of coronary perforations.

Adult↗

Initial clinical experience with distal protection using the FilterWire in patients undergoing coronary artery and saphenous vein graft percutaneous intervention.

Percutaneous coronary intervention (PCI) of saphenous vein grafts (SVG) and native coronary arteries may be associated with embolization of particulate debris into the distal microcirculation. The FilterWire uses a polyurethane filter bag contained on a radiopaque loop to trap embolic debris during native vessel and SVG intervention. The objectives of this study were to assess the feasibility and safety of the FilterWire during PCI and to examine the size and content of the particulate debris captured during SVG and native vessel intervention. Early angiographic, in-hospital, and 30-day clinical outcomes were reviewed in 35 patients with 36 lesions treated with the FilterWire during PCI. Lesions were located in 22 (61%) native coronary arteries and in 14 (39%) SVGs. Multivessel coronary artery disease was present in 75% of patients. Lesions were complex (ACC/AHA complexity B2 or C) in 81% of cases. The FilterWire was successfully delivered and deployed distal to the site of coronary intervention in 92% of lesions, including 95% of native vessels and 82% of SVG lesions. Embolic debris was entrapped in 82% of these cases. The average particulate debris had a mean major axis of 490 microm (range, 45-3,302 microm) and minor axis of 226 microm (range, 33-1,677 microm). Although reduced flow was common (36.1%) when the FilterWire was in place, there were no sustained episodes of abrupt closure and only one (2.8%) patient developed sustained no-reflow after FilterWire removal. Distal branch vessel embolization was found in four (11.1%) cases. Major adverse cardiac events occurred in 5 (14%) of 35 patients treated with the device, although 2 of these patients were evolving an acute myocardial infarction at the time of the procedure; in patients meeting the prospectively defined inclusion criteria, the major adverse cardiac event was 6%. These results suggest that the FilterWire is a feasible and safe method of collecting particulate debris released during SVG and native vessel coronary intervention. Its benefit over conventional therapy and other distal protection devices is currently under study.

Aged↗

Efficacy and feasibility of helixcision for debulking neointimal hyperplasia for in-stent restenosis.

The Helixcision system is a novel 6 Fr-compatible catheter designed to debulk tissue for in-stent restenosis lesions. The purpose of this study was to determine the efficacy and feasibility of this new system for removing neointimal hyperplasia. A total of 32 in-stent restenosis lesions in 32 patients were treated with helixcision followed by balloon angioplasty. Debulking efficacy was assessed with serial baseline intravascular ultrasound (IVUS) in a subset of 18 lesions. To investigate longitudinal efficacy, 3D analysis was also performed in 12 lesions with automated pullback to calculate average cross-sectional areas across the stent. Prior to procedure, the angiographic reference diameter was 2.60 +/- 0.46 mm. Immediately after procedure, minimum lumen diameter improved from 0.84 +/- 0.33 to 2.19 +/- 0.41 mm (P < 0.0001). IVUS showed a significant reduction of intimal area (IA) after helixcision (from 4.95 +/- 2.04 to 2.88 +/- 1.48 mm(2); P < 0.001). Adjunctive balloon angioplasty further improved lumen area (LA) mainly by stent expansion rather than IA reduction at the site of minimum lumen area. The degrees of IA reduction and LA improvement were closely similar in volumetric analysis. Thirty-day and 6-month clinical follow-up were available in 97% (n = 31) and 72% (n = 23) of the enrolled patients, respectively. At 30-day follow-up, no major adverse cardiac event was reported except for periprocedural CK elevation in two patients (6%). Target legion revascularization within 6 months was performed in six patients (26%). Preliminary results of helixcision indicate that this system is safe and feasible for the treatment of in-stent restenosis. The concordant results between 2D and 3D IVUS analyses suggest that this unique technology can achieve uniform longitudinal debulking throughout the stent. The long-term outcomes appeared to be favorable, considering the relatively diffuse lesion morphology.

Adult↗

The lunar stent characteristics and clinical results.

One of the frequent long-term complications after stent implantation is restenosis due to the building up of a neointima within the artery, as well as endovascular hyperplasia (tissue growth). The interesting feature of the Lunar stent from Inflow Dynamics is that it is coated with a layer of iridium oxide. The iridium oxide coating is believed to reduce restenosis by decreasing the inflammatory response to the stent via its antioxidant action. The MOONLIGHT (Multicenter Objective ObservatioNal Lunar Iridiumoxide intimal GrowtH Trial) study was carried out to evaluate the immediate outcome and long-term angiographic success after implantation of Lunar stents. Between March 2001 and November 2001, 87 patients with 99 lesions were enrolled in this study and were treated with 12 and 16 mm long iridium-oxide coated Lunar stents. Delivery of the Lunar stent was successful in most lesions and the optimal radiopacity facilitated optimal stent positioning with optimal immediate clinical and angiographic results is an unselected patient and lesion population. Preliminary clinical and angiographic follow-up show a low rate of cardiac events at 6 months (16.1% MACE) and a moderate hyperplastic response.

Adult↗

[State of treatment of coronary artery disease by drug releasing stents].

BACKGROUND: Despite improved technologies restenosis remains the main drawback of catheter-based interventions in coronary artery disease. Local application of anti-proliferative drugs through drug releasing stents is a promising concept addressed to solve this problem. DRUG RELEASING STENTS: Today, given the technical capabilities for controlled drug release from coronary stents, the development of drug eluting stents has emerged as one of the main research areas in interventional cardiovascular medicine. Several different approaches for drug loading on coronary stents as well as a variety of antiproliferative and anti-inflammatory agents, such as paclitaxel, actinomycin D, sirolimus, tacrolimus, everolimus and dexamethasone are under clinical investigation. RESULTS: Since the first enthusiastic reports from first in-man observations with drug coated stents, the success of the combination of both a biological and a mechanical approach has been proved in several controlled studies with restenosis rates between 0% in the RAVEL trial (sirolimus, Cordis Bx Velocity trade mark stent), 0% in the TAXUS I trial (paclitaxel, Boston Scientific NIRx trade mark stent) and 4% in the ASPECT Study (paclitaxel, Cook V-Flex plus trade mark stent). The risk of stent thrombosis seems to depend on the dose of the antiproliferative drug - in the SCORE trial stent thrombosis occurred in 6.3% of patients with high dose of QP2 and the antiplatelet therapy, in the ASPECT subgroup with cilostazol instead of clopidogrel and high dose of paclitaxel in up to 25%, whereas in RAVEL and TAXUS I no stent thrombosis was observed. CONCLUSION: If the "one digit" restenosis rate observed in clinical trials could be confirmed in clinical practice without increase of complications, especially stent thrombosis using multiple and/or long stents, we can expect in the near future that implanting drug eluting stents in larger patient groups and lesion subsets will cause a reduction of patients with need for surgical revascularization.

Angioplasty, Balloon, Coronary↗

Initial experience with paclitaxel-coated stents.

Local delivery of immunosuppressive or antiproliferative agents using a drug-eluting stent is a new technology that is supposed to inhibit in-stent restenosis, thus providing a biological and mechanical solution. This technique is a very promising. To date, several agents have been used, including paclitaxel, QP-2, rapamycin, actinomycin D, dexamethason, tacrolimus, and everolimus. Several studies, published recently or still ongoing, have evaluated these drugs as to their release kinetics, effective dosage, safety in clinical practice, and benefit. These studies include: SCORE (paclitaxel derivative), TAXUS I-VI, ELUTES, ASPECT, DELIVER (paclitaxel), RAVEL, SIRIUS (sirolimus), ACTION (actinomycin), EVIDENT, PRESENT (tacrolimus), EMPEROR (dexamethason), and FUTURE (everolimus). Paclitaxel was one of the first stent-based antiproliferative agents under clinical investigation that provided profound inhibition of neointimal thickening depending on delivery duration and drug dosage. The randomized, multicenter SCORE trail (Quanam stent, paclitaxel-coated) enrolled 266 patients at 17 sites. At 6-month's follow-up, a drop of 83% in stent restenosis using the drug-eluting stent could be achieved (6.4% drug-eluting stent vs 36.9% control group), which was attributable to a remarkable decrease in intimal proliferation. Unfortunately, due to frequent stent thrombosis and side-branch occlusions, the reported 30-day MACE rate was 10.2%. The randomized TAXUS-I safety trial (BSC, NIRx, paclitaxel-coated) also demonstrated beneficial reduction of restenotic lesions at 6-month's follow-up (0% vs 10%) but was associated with the absence of thrombotic events presumably due to less drug dosage. The ongoing TAXUS II-VI trials are addressing additional insight regarding the efficacy of the TAXUS paclitaxel-eluting stent. ASPECT and ELUTES evaluated paclitaxel-coated stents (i.e., Cook and Supra G), including subgroups with different drug dosages. With respect to stent restenosis and neointimal proliferation, both studies demonstrated a clear dose response. The RAVEL and the SIRIUS trials evaluated sirolimus-coated stents (i.e., Cordis, Johnson & Johnson, and Bx VELOCITY stents). Results confirmed the beneficial findings regarding reduction of renarrowing using a drug-eluting stent without any major adverse effects. Although parameters such as drug toxicity, optimal drug dosage, or delayed endothelial healing still need to be evaluated, today's clinical experience indicates that drug-coated stents are extremely beneficial in the interventional treatment of coronary lesions.

Clinical Trials as Topic↗