Search PubMed⌕ Search

Biomedical subjects

Eberhard Grube

Publications and source records attributed to Eberhard Grube.

At least 37 records · Page 2Linked to original sources

Two-year-plus follow-up of a paclitaxel-eluting stent in de novo coronary narrowings (TAXUS I).

Early results with polymer-based paclitaxel-eluting stents have shown significant improvements in the clinical and angiographic parameters of restenosis, as well as excellent safety outcomes. However, the duration of these beneficial effects is unknown. Therefore, the clinical outcomes of the TAXUS I study population were evaluated at 2- and 3-year follow-up. In TAXUS I, 61 patients with single, focal coronary lesions were randomly assigned to receive either a paclitaxel-eluting TAXUS stent (n = 31) or a bare metal control stent (n = 30). Low rates of composite major adverse cardiac events (MACEs) reported at 1-year follow-up (3.2% TAXUS vs 10.0% control) were maintained at 2 and 3 years, with no additional MACEs in either treatment group 1 year after implantation. The single target vessel revascularization in the TAXUS group was remote from the target lesion in contrast to 3 target lesion revascularizations in the control group.

Aged↗

Angiographic, intravascular ultrasound, and fractional flow reserve evaluation of direct stenting vs. conventional stenting using BeStent2 in a multicentre randomized trial.

AIMS: Direct stenting (DS) may not be as safe and effective as conventional stenting. The objective was to demonstrate equivalence of post-procedural mean luminal diameter (MLD) by angiography after BeStent2 placement between DS and pre-dilatation (PD) strategy. METHODS AND RESULTS: Two hundred and two patients with a single de novo lesion (diameter >/=3.0 mm and length </=13 mm) were randomized to DS (n=101) vs. PD. Stent deployment was guided by on-line quantitative coronary angiography (QCA). A second randomization assigned half of the patients to intravascular ultrasound (IVUS) and fractional flow reserve (FFR) assessment. QCA was repeated at 6 months. Baseline characteristics were similar. Crossover to PD was necessary in seven DS patients. Stent deployment was successful in 97% (DS) and 98% (PD). The post-procedural MLD was 2.79+/-0.45 mm (DS) and 2.76+/-0.40 mm (PD). The null-hypothesis of non-equivalence could be rejected (95% one-sided; P=0.0003). The minimum stent area (IVUS) was 7.89+/-1.75 mm(2) (DS) and 8.07+/-2.37 mm(2) (PD; P=0.69), with an FFR of 0.92+/-0.07 and 0.92+/-0.05, respectively (P=0.97). Major adverse cardiac event rates at 6 months were 9% (DS) and 11% (PD; P=0.93). Target lesion re-angioplasty was 6% (DS) and 5% (PD; P=0.77). The in-stent restenosis rate by QCA was 7.4% (DS) and 6.8% (PD; P=0.87). CONCLUSION: DS with BeStent2 is equivalent to PD. Both strategies resulted in a low angiographic restenosis rate.

Angioplasty, Balloon, Coronary↗

Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents.

CONTEXT: Traditionally, stent thrombosis has been regarded as a complication of percutaneous coronary interventions during the first 30 postprocedural days. However, delayed endothelialization associated with the implantation of drug-eluting stents may extend the risk of thrombosis beyond 30 days. Data are limited regarding the risks and the impact of this phenomenon outside clinical trials. OBJECTIVE: To evaluate the incidence, predictors, and clinical outcome of stent thrombosis after implantation of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice. DESIGN, SETTING, AND PATIENTS: Prospective observational cohort study conducted at 1 academic hospital and 2 community hospitals in Germany and Italy. A total of 2229 consecutive patients underwent successful implantation of sirolimus-eluting (1062 patients, 1996 lesions, 2272 stents) or paclitaxel-eluting (1167 patients, 1801 lesions, 2223 stents) stents between April 2002 and January 2004. INTERVENTIONS: Implantation of a drug-eluting stent (sirolimus or paclitaxel). All patients were pretreated with ticlopidine or clopidogrel and aspirin. Aspirin was continued indefinitely and clopidogrel or ticlopidine for at least 3 months after sirolimus-eluting and for at least 6 months after paclitaxel-eluting stent implantation. MAIN OUTCOME MEASURES: Subacute thrombosis (from procedure end through 30 days), late thrombosis (>30 days), and cumulative stent thrombosis. RESULTS: At 9-month follow-up, 29 patients (1.3%) had stent thrombosis (9 [0.8%] with sirolimus and 20 [1.7%] with paclitaxel; P = .09). Fourteen patients had subacute thrombosis (0.6%) and 15 patients had late thrombosis (0.7%). Among these 29 patients, 13 died (case fatality rate, 45%). Independent predictors of stent thrombosis were premature antiplatelet therapy discontinuation (hazard ratio [HR], 89.78; 95% CI, 29.90-269.60; P<.001), renal failure (HR, 6.49; 95% CI, 2.60-16.15; P<.001), bifurcation lesions (HR, 6.42; 95% CI, 2.93-14.07; P<.001), diabetes (HR, 3.71; 95% CI, 1.74-7.89; P = .001), and a lower ejection fraction (HR, 1.09; 95% CI, 1.05-1.36; P<.001 for each 10% decrease). CONCLUSIONS: The cumulative incidence of stent thrombosis 9 months after successful drug-eluting stent implantation in consecutive "real-world" patients was substantially higher than the rate reported in clinical trials. Premature antiplatelet therapy discontinuation, renal failure, bifurcation lesions, diabetes, and low ejection fraction were identified as predictors of thrombotic events.

Angioplasty, Balloon, Coronary↗

Effectiveness and safety of sirolimus-eluting stents in the treatment of restenosis after coronary stent placement.

BACKGROUND: In-stent restenosis is notoriously difficult to treat by repeat catheter intervention because of its propensity for aggressive recurrent neointimal formation. This study sought to assess the effectiveness and safety of the sirolimus-eluting stent in the treatment of in-stent restenosis. METHODS AND RESULTS: The study was designed as a prospective multicenter registry. We included 162 patients with in-stent restenosis of a native coronary artery who had a clinical indication for repeat intervention. Patients were scheduled for follow-up angiography at 6 months. The primary end point was in-lesion late loss. Follow-up angiography was performed in 155 patients. We obtained an in-lesion late loss of 0.08+/-0.49 mm and a binary restenosis rate of 9.7% (15/155), which prompted reintervention in 7.4% (12/162) at 9 months. The 9-month rate of death was 1.2% (2/162) and that of nonfatal myocardial infarction was 1.2% (2/162). CONCLUSIONS: Sirolimus-eluting stents were highly efficacious and safe in the treatment of in-stent restenosis. Our study provides rationale for the use of sirolimus-eluting stents in the treatment of in-stent restenosis.

Aged↗

Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: insights from the randomized TAXUS II trial.

BACKGROUND: The clinical impact of late incomplete stent apposition (ISA) for drug-eluting stents is unknown. We sought to prospectively investigate the incidence and extent of ISA after the procedure and at 6-month follow-up of paclitaxel-eluting stents in comparison with bare metal stents (BMS) and survey the clinical significance of ISA over a period of 12 months. METHODS AND RESULTS: TAXUS II was a randomized, double-blind study with 536 patients in 2 consecutive cohorts comparing slow-release (SR; 131 patients) and moderate-release (MR; 135 patients) paclitaxel-eluting stents with BMS (270 patients). This intravascular ultrasound (IVUS) substudy included patients who underwent serial IVUS examination after the procedure and at 6 months (BMS, 240 patients; SR, 113; MR, 116). The qualitative and quantitative analyses of ISA were performed by an independent, blinded core laboratory. More than half of the instances of ISA observed after the procedure resolved at 6 months in all groups. No difference in the incidence of late-acquired ISA was observed among the 3 groups (BMS, 5.4%; SR, 8.0%; MR, 9.5%; P=0.306), with a similar ISA volume (BMS, 11.4 mm3; SR, 21.7 mm3; MR, 8.5 mm3; P=0.18). Late-acquired ISA was the result of an increase of vessel area without change in plaque behind the stent. Predictive factors of late-acquired ISA were lesion length, unstable angina, and absence of diabetes. No stent thrombosis occurred in the patients diagnosed with ISA over a period of 12 months. CONCLUSIONS: The incidence and extent of late-acquired ISA are comparable in paclitaxel-eluting stents and BMS. ISA is a pure IVUS finding without clinical repercussions.

Aged↗

Angiographic results of the first human experience with everolimus-eluting stents for the treatment of coronary lesions (the FUTURE I trial).

The purpose of this study was to report the angiographic findings of the first human evaluation of the everolimus-eluting stent (EES) for the treatment of noncomplex coronary lesions. Forty-two patients with de novo coronary lesions (2.75 to 4.00 mm vessels; lesion length, <18 mm) were prospectively randomized in a 2:1 ratio to receive either the EES (n = 27) or a metallic stent (n = 15). Baseline clinical and angiographic characteristics were similar among both groups. At 6-month follow-up, EES had a lower in-stent late lumen loss (0.10 +/- 0.22 vs 0.85 +/- 0.32 mm, p <0.0001) and in-segment diameter stenoses (20.7 +/- 12.3% vs 37.0 +/- 15.8%, p = 0.002). There was no in-stent restenosis with EES; however, 1 focal distal edge restenosis was present. There was 1 in-stent and 1 in-segment (proximal edge) restenosis in the metallic stent group. There was no stent thrombosis or aneurysm formation at follow-up in either group.

Aged↗

Polymer-based paclitaxel-eluting stent for treatment of chronic total occlusions of native coronaries: results of a Taxus CTO registry.

The purpose of this prospective nonrandomized study was to evaluate both safety and efficacy of the polymer-based paclitaxel-eluting Taxus stent for treatment of chronic total coronary occlusions. Drug-eluting stents have been proven safe and efficacious in suppressing neointimal proliferation when used in simple native de novo coronary lesions. However, there are only limited data on safety and efficacy of these stents for treatment of more difficult lesion subsets, especially chronic total occlusions. Forty-five consecutive symptomatic patients with chronic total coronary occlusions were included in this observational single-arm study. Only patients with successfully crossed occlusions were enrolled. Primary endpoints were binary restenosis and late lumen loss at 6-month angiographic follow-up. Secondary endpoints were MACE at 30-day and 6-month follow-up. The 30-day MACE rate was 0%. At 6 months, the cumulative MACE-free survival was 84.4%. There were no deaths, myocardial infarctions, or stent thrombosis up to 6 months poststenting. At angiographic follow-up, the in-stent restenosis rate was 13.2% (5/38). There was a total of five in-stent restenoses, with three focal and two diffuse restenosis patterns. The in-segment late lumen loss was 0.13 +/- 0.58 mm. The stent edge analyses revealed a late loss of 0.21 +/- 0.66 proximally and a negative late loss of -0.10 +/- 0.67 at the distal edge segment. This study shows safety and indicators of efficacy of implantation of the paclitaxel-eluting Taxus stent for treatment of chronic total coronary occlusions. The quantitative angiographic analysis revealed beneficial results with respect to the efficacy surrogates binary restenosis rate and late loss.

Antineoplastic Agents, Phytogenic↗

First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis.

BACKGROUND: Percutaneous aortic valve replacement is a new technology for the treatment of patients with significant aortic valve stenosis. We present the first report on a human implantation of a self-expanding aortic valve prosthesis, which is composed of three bovine pericardial leaflets inserted within a self-expanding nitinol stent. The 73-year-old woman presented with severe symptomatic aortic valve stenosis (mean transvalvular gradient of 45 mmHg; valve area of 0.7 cm2). Surgical valve replacement had been declined for the patient because of comorbidities, including previous bypass surgery. METHOD AND RESULTS: A retrograde approach via the common iliac artery was used for valve deployment. The contralateral femoral vessels were used for a temporary extracorporal circulation, unloading the left ventricle during the actual stent expansion. Clinical, hemodynamic, and echocardiographic outcomes were assessed serially during the procedure. Clinical and echocardiographic follow-up at day 1, 2, and 14 post procedure was performed to evaluate the short-term outcome. The prosthesis was successfully deployed within the native aortic valve, with accurate and stable positioning and with no impairment of the coronary artery or vein graft blood flow. 2D and doppler echo immediately after device deployment showed a significant reduction in transaortic mean pressure gradient (from 45 to 8 mmHg) without evidence of aortic or mitral valve insufficiency. The clinical status has then significantly improved. These results remained unchanged up to the day 14 follow-up. CONCLUSION: This case report demonstrates a successful percutaneous implantation of a self-expanding aortic valve prosthesis with remarkable functional and clinical improvements in the acute and short-term outcome.

Aged↗

Actinomycin-eluting stent for coronary revascularization: a randomized feasibility and safety study: the ACTION trial.

OBJECTIVES: We sought to demonstrate the safety and performance of the actinomycin D-coated Multilink-Tetra stent(Guidant Corp., Santa Clara, California) in the treatment of patients with single de novo native coronary lesions. BACKGROUND: Drug-eluting stents (DES) releasing sirolimus or paclitaxel dramatically reduce restenosis. The anti-proliferative drug, actinomycin D, which is highly effective in reducing neointimal proliferation in preclinical studies, was selected for clinical evaluation. METHODS: The multi-center, single-blind, three-arm ACTinomycin-eluting stent Improves Outcomes by reducing Neointimal hyperplasia (ACTION) trial randomized 360 patients to receive a DES (2.5 or 10 microg/cm(2) of actinomycin D) or metallic stent (MS). The primary end points were major adverse cardiac events (MACE) at 30 days, diameter stenosis by angiography, tissue effects, and neointimal volume by intravascular ultrasound (IVUS) at six months. When early monitoring revealed an increased rate of repeat revascularization, the protocol was amended to allow for additional follow-up for DES patients. Angiographic control of MS patients was no longer mandatory. RESULTS: The biased selection of DES patients undergoing IVUS follow-up invalidated the interpretation of the IVUS findings. The in-stent late lumen loss and that at the proximal and distal edges were higher in both DES groups than in the MS group and resulted in higher six-month and one-year MACE (34.8% and 43.1% vs. 13.5%), driven exclusively by target vessel revascularization without excess death or myocardial infarction. CONCLUSIONS: The results of the ACTION trial indicate that all anti-proliferative drugs will not uniformly show a drug class effect in the prevention of restenosis.

Aged↗

High-dose 7-hexanoyltaxol-eluting stent with polymer sleeves for coronary revascularization: one-year results from the SCORE randomized trial.

OBJECTIVES: The Study to COmpare REstenosis Rate between QueST and QuaDDS-QP2 (SCORE) trial was a multicenter, randomized, open-label trial comparing the safety and performance of 13- and 17-mm QuaDDS stents (n = 126) (Quanam Medical Corp., Santa Clara, California/Boston Scientific Corp., Natick, Massachusetts) versus uncoated control stents (n = 140) in focal, de novo coronary lesions. BACKGROUND: The pioneering drug-delivery QuaDDS stent used four to six acrylate polymer sleeves, each loaded with 800 microg of the paclitaxel derivative 7-hexanoyltaxol. METHODS: Clinical end points were assessed at 1, 6, and 12 months post procedure. Quantitative coronary angiography and intravascular ultrasound were performed post procedure and at six-month follow-up. RESULTS: In the QuaDDS group, early stent thrombosis and myocardial infarction (MI) rates were significantly higher, leading to premature cessation of enrollment. For the QuaDDS group, the stent thrombosis rate increased from 3.2% to 10.3% between 1 and 12 months, associated with increased non-Q-wave MI and death rates. The angiographic restenosis rate at six months was reduced from 32.7% (control) to 7.4% (p < 0.0001). However, the primary end point was not met with six-month target vessel revascularization (TVR) rate as well as the composite major adverse cardiac event rates (cardiac death, MI, and TVR) comparable between groups. CONCLUSIONS: Despite angiographic indications of potential anti-restenotic benefit, increased rates of stent thrombosis, MI, and cardiac death associated with the QuaDDS stent show an unacceptable safety profile.

Aged↗

Six- and twelve-month results from first human experience using everolimus-eluting stents with bioabsorbable polymer.

BACKGROUND: Everolimus, an active immunosuppressive and antiproliferative agent of the same family as sirolimus (rapamycin), has demonstrated significant reduction of neointimal proliferation in animal studies. The First Use To Underscore restenosis Reduction with Everolimus (FUTURE) I trial was the first in-human experience to evaluate the safety and efficacy of everolimus-eluting stents (EES), coated with a bioabsorbable polymer, compared with bare metal stents (BMS). METHODS AND RESULTS: FUTURE I was a prospective, single-blind, randomized trial that enrolled 42 patients with de novo coronary lesions (EES 27, BMS 15). Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low at 30 days and 6 months, without any early or late stent thrombosis for either group (P=NS). Between 6 and 12 months, there were no additional reports of major adverse cardiac events. The 6-month angiographic in-stent restenosis rate was 0% versus 9.1% (1 patient) (P=NS), with an associated late loss of 0.11 mm versus 0.85 mm (P<0.001), and the in-segment restenosis rate was 4% (1 patient) and 9.1% (1 patient) (P=NS) for EES and BMS, respectively. Intravascular ultrasound analysis revealed a significant reduction of percent neointimal volume in EES compared with BMS (2.9+/-1.9 mm3/mm versus 22.4+/-9.4 mm3/mm, P<0.001). There was no late stent malapposition in either group. The safety and efficacy of the EES appeared to be sustained at 12 months. CONCLUSIONS: In this initial clinical experience, EES with bioabsorbable polymer demonstrated a safe and efficacious method to reduce in-stent neointimal hyperplasia and restenosis.

Aged↗

Treatment of In-Stent restenosis using a stent with non-polymer-based paclitaxel elution.

Treatment of in-stent restenosis remains a therapeutic challenge. Twenty-seven lesions with in-stent restenosis were treated with non-polymer-based paclitaxel-eluting stents. At 6-month follow-up, in-stent late loss was 0.44 +/- 0.54 mm and the restenosis rate was 20%, indicating effective treatment for reduction of recurrent restenosis.

Coronary Angiography↗

Early experience with a novel plaque excision system for the treatment of complex coronary lesions.

The use of directional coronary atherectomy (DCA) in current practice has been limited. The SilverHawk System is a newly developed plaque excision device that aims to overcome the drawbacks of prior DCA platforms. The device was evaluated in a porcine coronary model and in a series of patients. Procedural variables along with outcomes were reviewed. Quantitative angiography (QCA) was performed and excised tissue fragments were weighed and examined histologically. In porcine cases, pretreatment MLD increased from 0.51 +/- 0.26 to 2.36 +/- 0.59 mm postdebulking and 19.9 +/- 7.6 mg of tissue was retrieved. In human cases, pretreatment MLD increased from 0.8 +/- 0.4 to 2.2 +/- 0.5 mm postdebulking and 15.2 +/- 7.8 mg of tissue was retrieved without complications. These data show that the SilverHawk System may offer significant utility in treating a wide variety of complex coronary lesions.

Adult↗