Search PubMed⌕ Search

Biomedical subjects

E Wolner

Publications and source records attributed to E Wolner.

At least 127 records · Page 7Linked to original sources

Perioperative risk factors for mortality in patients with acute type A aortic dissection.

BACKGROUND: Patients with acute type A aortic dissection are associated with a high mortality rate and postoperative complications. This study was designed to explore perioperative risk factors for death in patients with acute type A aortic dissection. METHODS AND RESULTS: One hundred nine consecutive surgical patients with acute type A aortic dissection were included in the present study. Thirty-five perioperative risk factors were used in the statistical analysis for mortality prediction. The 30-day mortality rate for all patients was 30% (33 of 109). Univariate analysis revealed 5 preoperative and intraoperative risk factors that were found to be statistically significant predictors for death: older age, renal failure, preoperative hemodynamic instability, preoperative cardiopulmonary resuscitation, and lack of retrograde cerebral perfusion (P < 0.05). Rupture of aneurysm, hypothermic circulatory arrest time, and operation date were not found to be risk factors for death. Stepwise multiple logistic regression confirmed that older age and lack of retrograde cerebral perfusion were statistically significant independent risk factors for death (P < 0.05). Four postoperative complications were found to be statistically significant prognostic indicators for death: liver failure, stroke, sepsis, and reoperation after the initial surgery (P < 0.05). CONCLUSIONS: Perioperative risk factors for death after the operation for acute type A aortic dissection were identified. This will allow physicians and surgeons to better assess the patient's risk, which will lead to better outcome.

Acute Disease↗

[Functional results and long-term outcome after bilateral lung transplantation for pulmonary hypertension].

Pulmonary hypertension (PH) signifies elevated blood pressure in the pulmonary circulation either due to clearly defined causes (cardiac, pulmonary-parenchymatous, systemic) or of idiopathic origin (primary PH, PPH). While conservative treatment is beneficial only for a small number of patients, lung transplantation represents a curative measure. The optimal form of transplantation [i.e. single lung (SLTX), bilateral lung (BLTX) or combined heart-lung transplantation (HLTX)] is still under discussion. This study is a retrospective analysis of 16 patients with different forms of PH who underwent BLTX from 1992 to 1996 in Vienna. Four patients had Eisenmenger's disease due to atrial septum defect, 3 had chronic thromboembolic PH and 9 had PPH. BLTX with cardiopulmonary bypass was the standard procedure in all patients. Acute retransplantation had to be performed in 3 patients. Mean pulmonary arterial pressure was reduced from 63 +/- 11 mmHg preoperatively to 23 +/- 5 mmHg on the second day postoperatively (p < 0.0001), while the cardiac index concomitantly improved from 2.1 +/- 0.5 to 3.9 +/- 1.2 l/min/m2 (p < 0.05). Echocardiography proved normalisation of right ventricular wall thickness and end-diastolic diameter within 12 months, while tricuspid insufficiency, present in all patients before transplantation, resolved completely. Perioperatively 4 patients (25%) died due to septic complications (n = 3) or therapy refractory rejection (n = 1). Follow-up of the remaining patients ranged from 6 to 51 months (mean 33 +/- 17). One patient died at 8 months due to fungal sepsis. Eleven patients (68%) are currently alive. Only 2 of them show functional signs of chronic allograft rejection (bronchiolitis obliterans syndrome). All patients are at present in NYHA functional class I or II. In conclusion, BLTX results in complete recovery of right ventricular function and morphology and offers good functional long-term results. Because SLTX correlates with a high incidence of reperfusion edema, and HLTX is seriously limited by the scarcity of donor organs, BLTX should be the method of choice for treating end stage PH.

Adult↗

Blood rheology in patients with native heart valve disease and after valve replacement.

Patients with heart valve disease have rheologic abnormalities that are more pronounced in double valve disease than in mitral or aortic valve disease; after valve replacement surgery, the degree of rheologic abnormality is more pronounced in patients with mechanical and biological prostheses than in those with homografts and pulmonary autografts. Rheologic abnormalities seen in these patients might be related to the different incidences of thromboembolism in the presence of various valve defects and various types of prostheses.

Adolescent↗

Morphologic grading of the emphysematous lung and its relation to improvement after lung volume reduction surgery.

BACKGROUND: The morphologic criteria for lung volume reduction surgery, such as severity and heterogeneity of disease, differ widely between patients, and this makes any comparison of functional results between centers difficult. Here we present a morphologic scoring system and describe its possible relation to functional results after lung volume reduction operations. METHODS: Between September 1994 and December 1996, 47 consecutive patients underwent bilateral lung volume reduction operations. The morphology of emphysema was quantified with standard chest roentgenograms and computed tomographic imaging, which were used to define the following four variables: degree of hyperinflation (grade 0 to 4), degree of impairment in diaphragmatic mechanics, degree of heterogeneity (grade 0 to 4), and severity of parenchymal destruction (range, 0 to 48). RESULTS: All four variables showed good reproducibility. Degree of heterogeneity had a significant influence on functional improvement in terms of forced expiratory volume in 1 second (p = 0.0413, r2 = 0.11). Severity of parenchymal destruction was significantly associated with 30-day mortality: patients who died after operation (n = 4) had a severity of parenchymal destruction of 28.4 +/- 2.1 compared with 21.3 +/- 1.0 for those who survived (n = 43) (p = 0.003). CONCLUSIONS: This morphologic scoring system is easy to use, is reproducible, and allows quantification of the morphology of emphysema, thereby allowing definition of different patient subgroups. Such an exact morphologic quantification may help in the comparison of functional results between centers. Furthermore, the risk factors for certain morphologic subgroups, such as patients with a homogeneous distribution pattern, may be clarified in the future.

Adult↗

Long-term results after repeated surgical removal of pulmonary metastases.

BACKGROUND: Although surgical resection is accepted widely as first-line therapy for pulmonary metastases, few data exist on the surgical treatment of recurrent pulmonary metastatic disease. In a retrospective study, we analyzed patients who were operated on repeatedly for recurrent metastatic disease of the lung with curative intent over a 20-year period. METHODS: From 1973 to 1993, 396 metastasectomies were performed in 330 patients. The study population included patients with any histologic tumor type who had undergone at least two (range, 2 to 4) complete surgical procedures because of recurrent metastatic disease. Surgical and functional resectability of the recurrent lung metastases and control of the primary lesion served as objective criteria for reoperation. A subgroup of 35 patients that included patients with histologic findings such as epithelial cancer and osteosarcoma then was analyzed retrospectively to calculate prognosis and define selection criteria for repeated pulmonary metastasectomy. RESULTS: The 5- and 10-year survival rates after the first metastasectomy were 48% and 28%, respectively. The overall median survival was 60 months. A mean disease-free interval (calculated for all intervals, with a minimum of two) of greater than 1 year was significantly associated with a survival advantage beyond the last operation. Univariate analysis failed to show size, number, increase or decrease in number or size, or distribution of metastases as factors related significantly to survival. CONCLUSIONS: Although patients with different histologic tumor types were included, the study population appeared to be homogeneous in terms of survival benefit and prognostic factors, and it probably represented the selection of biologically favorable tumors in which histology, size, number, and laterality are of minor importance. We conclude that patients who are persistently free of disease at the primary location but who have recurrent, resectable metastatic disease of the lung are likely to benefit from operation a second, third, or even fourth time.

Adolescent↗

Endovascular stent graft repair for aneurysms on the descending thoracic aorta.

BACKGROUND: The traditional treatment of aneurysms of the descending thoracic aorta includes posterolateral thoracotomy and aortic replacement with a prosthetic graft. In this study, we report our experiences and results in endovascular stent graft placement as an alternative to surgical repair. METHODS: Between January 1989 and July 1997, a total of 68 patients (24 women) underwent replacement of the thoracic aorta. Mean age at operation was 51 years. Fifty-eight patients underwent conventional surgical treatment. All of these patients were suitable candidates for endovascular stenting; however, no stent graft material was available at the time of operation. Ten patients (1 chronic dissection, 9 atherosclerotic aneurysm) received in the past 8 months the first commercially manufactured endovascular stent graft. The mean diameter of the aneurysms in this group was 7 cm (range, 6 to 8 cm). Two stent patients were operated on using only spinal cord analgesia. All stent grafts were custom designed for each of the 10 patients. RESULTS: The 30-day mortality in the conventional group was 31% versus 10% in the stent group. Mean length of intervention was 320 minutes in the conventional group versus 150 minutes in the endovascular group. Spinal cord injury occurred in 5 patients (12%) in the surgical group, whereas none of the stented patients developed any neurologic sequelae. Mean intensive care unit stay was 13 days, followed by a mean of 10 days on a ward in the first group compared to 4 days in the intensive care unit and 6 days on the ward in the stent group. One stent was required in 2 patients, two stents were required in 3 patients, and four stents were deployed in 5 patients of our series. Five patients required transposition of the left subclavian artery to achieve a sufficient neck for the proximal placement of the stent. There was complete thrombosis of the thoracic aortic aneurysm surrounding the stent graft in 8 patients (80%). Two patients required restenting as a result of leakage (20%). Stent graft placing was performed through the femoral artery in 8 patients, whereas access was only achieved through the abdominal aorta in 2 patients. CONCLUSIONS: These preliminary results demonstrate that endovascular stent graft replacement might be a promising, cheaper, and safe alternative method in selected patients with descending thoracic aneurysms.

Adult↗

Endothelialization of biosynthetic vascular prostheses after laser perforation.

OBJECTIVE: This study was undertaken to investigate the feasibility of transmural capillary ingrowth into the inner surface of biosynthetic vascular prostheses (Omniflow, BioNova, Melbourne, Australia) through perforations created by an excimer laser, thus inducing an endothelial cell coverage. METHOD: Biosynthetic vascular prostheses (Omniflow, 10 cm length, 6 mm diameter) were perforated with an excimer laser (diameter of the holes 50 to 100 microm, distance 4 mm) and implanted into the carotid arteries of eight sheep. They were compared to untreated Omniflow prostheses implanted at the contralateral side. Three months after implantation the prostheses were explanted and evaluated by gross morphology, histologic examination, scanning electron microscopy, and immunohistochemical staining for factor VIII to identify endothelial cells. RESULTS: All grafts remained patent. Gross morphologic examination revealed no significant difference in the thrombus-free surface between perforated and untreated prostheses. However, scanning electron microscopy showed endothelial cells in the midgraft portion of all perforated prostheses, whereas collagen fibers, fibrin meshwork, and activated platelets formed the inner layer in six of eight untreated Omniflow prostheses. Transmural capillary ingrowth in the laser group was verified by positive factor VIII staining for endothelial cells in the laser channels. CONCLUSION: Spontaneous endothelialization of biosynthetic vascular prostheses can be achieved by transmural capillary ingrowth through perforations in the wall of the prostheses in an experimental sheep model.

Anastomosis, Surgical↗

Long-term results of heart valve replacement with the Edwards Duromedics bileaflet prosthesis: a prospective ten-year clinical follow-up.

OBJECTIVE: The Edwards Duromedics valve (Baxter Healthcare Corp., Edwards Division, Santa Ana, Calif.) was designed with a self-irrigating hinge mechanism to reduce thromboembolic complications. After good initial clinical results, distribution was suspended in 1988 after reports of valve fracture after 20,000 valves had been implanted. The manufacturer conducted extensive studies to improve the Edwards Duromedics and reintroduced a modified version, which is available as Edwards Tekna. The purpose of the study was the evaluation of long-term results of the original Edwards Duromedics that might be important for the current version, the Edwards Tekna valve. METHODS: A prospective clinical 10-year follow-up was performed of 508 patients who underwent valve replacement with the Edwards Duromedics valve in the aortic (n = 268), mitral (n = 183), and aortic and mitral (n = 56) position. RESULTS: The perioperative mortality rate was 6.9%; follow-up was 98% complete, comprising 3648 patient-years for a mean follow-up of 86 months (range: 33 to 144 months). The actuarial freedom from complications at the 10-year follow-up and the incidence rate (percent per patient-year) were as follows: late mortality rate, 69.2% +/- 2.4% (3.5% per patient-year); thromboembolism, 90.7% +/- 1.6% (0.96% per patient-year); anticoagulation-related hemorrhage, 87.7% +/- 1.7% (1.34% per patient-year); prosthetic valve endocarditis, 96.7% +/- 0.09% (0.38% per patient-year); valve-related mortality rate, 89.3% +/- 1.6% (1.21% per patient-year); valve failure, 86.2% +/- 1.85% (1.54% per patient-year); and valve-related morbidity and mortality rate, 71.1% +/- 2.3% (3.2% per patient-year). Three leaflet escapes were observed (one lethal, two successful reoperations; 99.1% +/- 0.05% freedom, 0.08% per patient-year). All patients functionally improved (86% in New York Heart Association classes I and II), and incidence of anemia was insignificant. CONCLUSIONS: These results confirm that the Edwards Duromedics valve shows excellent performance concerning thromboembolism, hemolysis, and functional improvement and will serve as a reference for the last version, the Edwards Tekna valve, where comparable long-term data are currently not available.

Anticoagulants↗

Operations on the thoracic aorta and hypothermic circulatory arrest: is aprotinin safe?

INTRODUCTION: The safety of aprotinin, especially when used with profound hypothermic circulatory arrest, is still a matter of intense debate despite its presumed salutary effects on blood loss. Many investigators have reported toxic renal effects of high-dose aprotinin in such patients, but no prospective, randomized study has been conducted. To assess the potential detrimental effect of aprotinin on renal function and its putative reduction of blood loss, 50 patients undergoing thoracic aortic operations with the use of profound hypothermic circulatory arrest were randomly assigned to receive either low-dose aprotinin (1 x 10(6) kallikrein activation units) or placebo. METHODS: The specific renal tubular markers beta-2-microglobulin and beta-N-acetyl-D-glucosaminidase, as well as serum creatinine and blood urea nitrogen, creatinine clearance, sodium excretion, and potassium excretion, were measured to evaluate renal function preoperatively, immediately after the procedure, and 24 hours and 48 hours later. RESULTS: No statistically significant difference was found in any measured renal parameter between the two groups (analysis of variance). Renal dysfunction, defined as an elevation of serum creatinine early postoperatively (> or = 1.5 times the preoperative value), occurred in two patients who received aprotinin and in one patient in the control group. Temporary dialysis (hemodialysis or continuous venovenous hemofiltration) was needed in two patients in the aprotinin group versus one in the control group. Furthermore, patients treated with aprotinin had significantly less total postoperative blood loss (718 +/- 340 ml vs 920 +/- 387 ml, p = 0.04). The aprotinin recipients also had a significantly lower transfusion requirement (p < 0.05). CONCLUSION: This controlled trial of low-dose aprotinin in patients undergoing thoracic aortic operations using profound hypothermic circulatory arrest demonstrated no detectable deleterious effects on renal function; moreover, the use of aprotinin was associated with significantly lower need for transfusion.

Aged↗

Analysis of left ventricular function after emergency coronary artery bypass grafting for life-threatening ischaemia following primary revascularization.

OBJECTIVE: Severe ischemic injury in the first few hours following primary revascularization necessitates acute reoperation. To study the effect of emergency coronary artery bypass grafting, we followed 18 patients for up to 8 years, relating their changes of global and regional myocardial function during the acute event and after secondary revascularization to final outcome. METHODS: A total of 16 patients with coronary artery bypass grafting (CABG) and 2 PTCA were treated for coronary heart disease between 1989 and 1993 and experienced life-threatening ischemic events (94% cardiogenic shock, 39% ventricular fibrillation, 67% ischemic electrocardiograph (ECG) changes) within 2.3+/-1.6 h after primary revascularization. Reoperation was carried out 1.0+/-1.3 h after the occurrence of acute ischemia. Serial echoes were obtained during the acute event and after reoperation as well as during the follow-up period. RESULTS: Of the 18 patients, 8 are currently alive, 5 died within 30 days and 4 within the 1st year. There was one late death 5 years after surgery. Global and regional wall motion was evaluated using short axis views of transesophageal echoes taken during the acute event and after secondary revascularization, and compared with transthoracic echoes in long-term survivors up to 5 years after surgery. During the acute event left ventricular ejection fraction (LVEF) was reduced in 83% of the patients and improved significantly after reoperation (chi2 = 11.74, df= 2, P < 0.01). As to regional wall motion, 50% of the segments in non-revascularized areas remained abnormal. Regional wall motion after reoperation was significantly better in the surviving patients compared with patients dying in the post-operative course (chi2 = 6.23, df= 1, P < 0.05). The revascularization score ( > 75%) of abnormal contracting segments during the acute ischemic event was a significant determinant for long-term survival. CONCLUSION: We conclude that patient outcome is determined by the severity of regional wall motion abnormality during the acute ischemic event, the aggressiveness of the attempt to revascularize these perfusion territories and their improvement after revision. Long-term survival reflects, therefore, the extent of emergency revascularization and therefore the ability to identify ischemic perfusion territories for surgical strategy planning.

Aged↗

Experimental development of an electrically stimulated biological skeletal muscle ventricle for chronic aortic counterpulsation.

OBJECTIVE: The chronic shortage of donor organs for cardiac transplantation and the high costs for mechanical assist devices demand the development of alternative cardiac assist devices for the treatment of severe heart failure. Cardiac assistance by stimulated skeletal muscles is currently investigated as such a possible alternative. The goal of the presented study was to construct a newly designed biological skeletal muscle ventricle and to evaluate its possible hemodynamic efficacy in an acute sheep model. METHODS: A total of 14 adult sheep were used for acute experiments. The entire thoracic aorta including the aortic root was excised from a donor sheep. An aorto-pericardial pouch conduit (APPC) was created by enlarging the aortic circumference in its middle section with two strips of pericardium. This biological conduit was anastomosed in parallel to the descending aorta of a recipient sheep, using the aortic root as an inflow valve to the conduit. Stimulation electrodes were applicated to the thoracodorsal nerve and the latissimus dorsi muscle was detached from the trunk and wrapped around the pouch. ECG-triggered functional electrical stimulation was applied during cardiac diastole to simulate aortic counterpulsation. Stimulation was performed during various hemodynamic conditions. RESULTS: A standardised surgical procedure suitable for long term studies was established during six experiments. An APPC, with 70-80 mm filling volume, was found to be of optimal size. In another eight experiments, hemodynamic measurements were performed. Under stable hemodynamic conditions the stimulation of the biological skeletal muscle ventricle induced a significant increase of mean arterial pressure by 14% and mean diastolic pressure by 26%. During pharmacologically induced periods of cardiac failure, the stimulation of the APPC increased mean arterial pressure by 13% and mean diastolic pressure by 19%. In all eight experiments, the diastolic peak pressure reached supra-systolic values during stimulation. CONCLUSIONS: The results demonstrate the hemodynamic efficacy of this newly designed biological skeletal muscle ventricle as an aortic counterpulsation device. Chronic experiments using a preconditioned fatigue-resistant muscle will further help to evaluate its possible clinical significance.

Animals↗

Chronic hypercapnia should not exclude patients from lung volume reduction surgery.

OBJECTIVE: Chronic hypercapnia is still considered to increase the risk for perioperative mortality and therefore to be a contraindication for lung volume reduction surgery (LVRS). The aim of this study was to analyse the influences of hypercapnia upon postoperative outcome. METHODS: The functional improvement (preop vs. 3 months postop) and clinical outcome was studied in 22 patients with chronic hypercapnia (preoperative arterial pCO2 > or = 45 mmHg) who underwent LVRS between 9/94 and 2/97 and were compared to all other patients (n = 58) without hypercapnia. Data are expressed as the mean +/- SEM. RESULTS: The 30-day mortality was 9.1% (2/22) in patients with chronic hypercapnia (HC) and 5.2% (3/58) in patients with normal arterial pCO2 levels (control) (P = n.s). The stay on the ICU (3.5 +/- 0.8 vs. 2.1 +/- 0.3 days) and duration of chest drainage (7.3 +/- 1.2 vs. 7.2 +/- 0.8 days) was similar between both groups (HC vs. control) (P = n.s). The preoperative lung function (% of predicted) and blood gas (mmHg) parameters were significantly worse in HC patients compared to control patients. In both groups significant functional improvements were observed: FeV1 in the control group increased by 37% within the first 3 months (29.1 +/- 1.7% of predicted vs. 39.9 +/- 3.1% of predicted, P = 0.0198). In the HC group, FeV1 increased by 73% which was even higher than in the controls (19.5 +/- 1.5% of predicted vs. 33.7 +/- 4.7% of predicted, P = 0.0385). All patients of both groups who died perioperatively had a significantly higher severity of parenchymal destruction than those who survived (P = 0.0277 and 0.0380, respectively). CONCLUSIONS: Patients with chronic hypercapnia alone, had no significantly higher mortality and morbidity, and therefore should not be excluded from LVRS. However, the presence of additional risk factors, such as homogeneity of disease, high degree of parenchymal destruction or pulmonary hypertension should be considered as contraindications for the procedure.

Case-Control Studies↗

Quantification of mitral regurgitant flow using proximal isovelocity surface area method: a transesophageal echocardiography perioperative study.

OBJECTIVE: To investigate the usefulness of the color Doppler proximal isovelocity surface area (PISA) method, compared with the jet area method, in determining the severity of mitral regurgitation in the perioperative period using angiographic grading as a reference method. DESIGN: Randomized, controlled prospective study. SETTING: Single university hospital. METHODS: Thirty-three patients with native mitral valve insufficiency of different grade were studied. The color jet area in the left atrium, as well as PISA regurgitant stroke volume (RSV), were established. PISA RSV was calculated using a formula derived from previous in vitro and human studies: RSV = 2 pi r2 x v x RTVI/RPFV x (inlet angle/180 degrees), in which r is the radial distance between the first aliasing contour (red/blue interface); v is the aliasing velocity that is read from the color bar; RTVI is the time-velocity integral of the regurgitant jet from the continuous wave Doppler recordings; and RPFV is the corresponding peak flow velocity of the continuous wave regurgitant jet. RESULTS: The rank correlation coefficient between the angiographic grade of mitral regurgitation and the PISA method was rsp = 0.89 (p < 0.0001), and for the jet area was rsp = 0.44 (p < 0.01). There was close concordance between angiographic and PISA measurements of RSV (r = 0.92, p < 0.0001). Further, scatterplot of difference between the two measurements plotted against the mean of measurements showed good agreement. CONCLUSIONS: It was concluded that in patients with mitral regurgitation during the perioperative period, the PISA method is more suitable than the jet area method to determine the severity of mitral regurgitation, and only it provides a reliable technique to differentiate between grade I-II mitral regurgitation in patients with eccentric regurgitant jet and grade III-IV mitral regurgitation in patients with jet size that is bigger than transesophageal echocardiography left atrial size.

Adult↗

In vivo evaluation of the miniaturized Gyro centrifugal pump as an implantable ventricular assist device.

A miniaturized Gyro centrifugal pump has been developed to be incorporated into a totally implantable artificial heart. The Gyro PI (permanently implantable) model is a pivot bearing supported centrifugal pump with a priming volume of 20 ml. With the miniaturized actuator, the pump-actuator package has a height of 53 mm, a diameter of 65 mm, and a displacement volume of 145 ml. To evaluate the hemocompatibility and efficiency of the Gyro PI pump system, a plastic prototype (Gyro PI-601) was implanted into a bovine model as a left or right ventricular assist device (LVAD or RVAD), bypassing from the left ventricular apex to the descending aorta or from the right ventricular infundibulum to the main pulmonary artery. The calves were anticoagulated with heparin to maintain activated clotting times from 150 to 200 s. Four calves were supported for 23, 24, and 50 days in the LVAD studies, and 40 days in the RVAD study. The first calf died due to intrathoracic bleeding associated with sepsis. The second calf was euthanized for a low flow rate less than 2 L/min due to an obstructed inflow with growing pannus. The third and fourth calves were euthanized as scheduled. Renal and hepatic functions remained normal, and plasma free hemoglobin values were less than 8 mg/dL throughout the experiments. The fourth case showed flow rates of 4.83 +/- 0.57 L/min, input power of 6.16 +/- 0.49 W, and the inside temperature of the actuator of 43.5 +/- 0.52 degrees C. The pumps implanted in the fourth calf demonstrated no thrombus formation at the autopsy. These in vivo experiments revealed that the Gyro PI pump can provide adequate flow as an easily implantable, efficient, antithrombogenic, and nonhemolytic centrifugal LVAD or RVAD with miniaturized actuators.

Animals↗

Reversal of ventricular dilatation after correction of aortic incompetence: mechanical prosthesis compared with biological procedures.

BACKGROUND: The aim of the study was to compare early differences in reversal of LV dilatation between patients with mechanical prosthesis = group A (n = 51: Carbomedics = 40, Tekna/Edwards = 11) and biological procedures = group B (n = 75: pulmonary autograft = 36, aortic valve repair = 29, homograft = 10). METHODS: Since 1,990,126 consecutive patients younger than 50 years who had surgical correction of isolated aortic incompetence underwent echocardiographic examinations preoperatively, at discharge, and at one-year follow-up. Left-ventricular (LV) diameters were measured (LVEDD, LVESD) and matched to body surface area (LVESDI, LVEDDI and fractional shortening (FS) was calculated. Aortic peak flow velocities were assessed by Doppler technique and gradients were calculated. RESULTS: There were no significant differences preoperatively in aortic incompetence, NYHA classification, LVEDDI, LVESDI, and FS. In group B there was a significant decrease of LVESDI (p < 0.002) and LVEDDI (p < 0.001) but no change in FS at discharge. In group A a significant reduction of FS (p < 0.05) without any significant changes in LV size was observed. No patient died perioperatively or during the first year. At one-year follow-up (complete in 97.6% patients) there were no significant differences in LV diameters but group B had better ventricular function (p < 0.05) resulting in better NYHA classification (p < 0.05). Only group B had normal aortic valve gradients at discharge and at follow-up (A: 25.2 +/- 4.3 vs B: 10.2 +/- 2.4 mmHg). CONCLUSIONS: Normal aortic valve gradients in patients after aortic valve repair or allograft replacement for chronic aortic incompetence lead to early recovery from ventricular dilatation and significantly better ventricular function at discharge. One year postoperatively they had improved ventricular function and NYHA class in comparison with patients in whom a mechanical prosthesis was implanted.

Adult↗