Outcome of pediatric heart transplantation: an analysis of 27 cases.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to E Wolner.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: Excellent hemodynamic performance has been demonstrated after aortic valve replacement using the autologous pulmonary valve as described by D. Ross. However, in the pediatric population there is concern in regard to growth of the autograft and late dilatation in the systemic circulation. METHODS: Since 1991, 30 children (mean age, 11.3+/-3.1 years) had aortic valve replacement with the pulmonary autograft as a root replacement. All children had yearly clinical and echocardiographic follow-up. RESULTS: There were no perioperative deaths; one child died late in a car accident. At the last follow-up (mean follow-up, 4.3+/-2.6 years), all patients were in NYHA class I. There was one early reoperation, in which the autograft had to be reconstructed due to a leaflet perforation. There were no major valve related events. All children showed normal somatic growth. The annulus diameter increased significantly from 18+/-2 at surgery to 20+/-3.5 mm at the latest follow-up (P<0.004). The sinus also increased significantly in diameter from 29+/-4 at surgery to 34+/-2 mm at the last follow-up (P<0.001). This increase in autograft size, both for the annulus and the sinus, paralleled the increase in body surface area with no evidence for unproportional dilatation. Hemodynamic measurements demonstrated physiological peak gradients of 6.8+/-2.9 mmHg and no or trivial aortic insufficiency in 95% of this rapidly growing patient population. CONCLUSION: These data demonstrate growth of the pulmonary autograft parallel to somatic growth without undue dilatation in the systemic circulation. The hemodynamics are excellent with regard to physiological gradients and no increase in aortic insufficiency.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Haemodialysis is a widespread option for end-stage renal disease (ESRD). Long-term success of dialysis is, however, limited by a high rate of serious bacterial and viral infections. We compared T cell functions in ESRD patients undergoing haemodialysis (n = 20), or were not dialysed and received conventional medical treatment (n = 20). Healthy volunteers (n = 15) served as controls. The T cell phenotype was examined by immunofluorescence using fluorochrome-labelled monoclonal antibodies and FACS analysis. The concentration of soluble CD95/Fas and of tumour necrosis factor-alpha receptor type 1 (sTNFR1) in the sera was quantified by ELISA. Activation-induced programmed T cell death was triggered by anti-CD3/CD28 antibodies and measured by 7-AAD staining. All immunological tests were performed at least 1 month after dialysis initiation. T cell proliferation in response to phytohaemagglutinin or anti-CD3 monoclonal antibodies was moderately diminished in non-dialysed patients and markedly reduced in haemodialysis patients compared to healthy controls (P < 0.01 and P < 0.001, respectively). In a mixed lymphocyte culture the proliferative response of T cells from dialysed patients was significantly diminished (P < 0.001). T cells of both non-dialysed and dialysed patients have augmented CD95/Fas and CD45RO expression, increased sCD95/Fas and sTNFR1 release and spontaneously undergo apoptosis. Culture of T cells from haemodialysis patients with anti-CD3/CD28 antibodies increased the proportion of CD4(+) T cells committing activation-induced cell death by a mean 7.5-fold compared to T-helper cells from non-dialysed patients (P < 0.001). Renal failure and initiation of haemodialysis results in a reduced proliferative T cell response, an aberrant state of T cell activation and heightened susceptibility of CD4(+) T cells to activation-induced cell death.
As known from patients with pulsatile ventricular assist devices (VADs), early mobilization, physical exercise, and return to normal life are essential for optimal recovery. Recently, implantable rotary pumps became available for extended left ventricular support as bridges to transplantation. Modified procedures are essential for patient training and hospital discharge. The MicroMed-DeBakey VAD was implanted in 10 patients with end-stage heart disease. After recovery, regular ergometer training was performed with loads adapted to the patient's condition. Procedures for patient observation under outdoor conditions and a blood pressure measuring device for low pulse pressure conditions were developed. Improvement of physical condition was achieved in 8 patients. In the first 2 patients, exercise capacity was limited due to flow obstruction. In the following patients, an increase of workload on the ergometer up to 120 W was observed. Correlated with training, lactate/load relationship and heart rate decreased. Three patients were discharged from the hospital during support. The DeBakey-VAD system can support patients for extended time periods and is suitable for recovery and exercise. Under optimal patient and environmental conditions, discharge from the hospital can be obtained.
An implantable biventricular assist device (BVAD) has been developed at Baylor College of Medicine using 2 centrifugal blood pumps. The aim of this study was to investigate the exercise-reflex response during nonpulsatile biventricular assistance and to evaluate to which degree the autoregulation of the system would accommodate the changed hemodynamic situation during physical exercise. The Baylor Gyro PI 710 BVAD has been implanted into 2 calves (strain half-Dexter) in a biventricular bypass fashion with native heart remaining. Allowing a 10 day convalescence, 2 animals were subjected to incremental exercise tests. The speed of the treadmill was increased at zero slope from 0.7 mph to 1.5 mph with increments of 0.2 mph every 3 min. During the exercise the pump flows were maintained at a fixed rate (6.93 +/- 0.01 L/min for the left ventricular assist device and 5.36 +/- 1.44 L/min for the right ventricular assist device). Hemodynamic parameters and pump performance were recorded continuously. The cardiac output (CO) and heart rate (HR) increased significantly during the exercise. CO increased from 11.1 +/- 0.3 to 13.1 +/- 0.4 L/min, and HR increased from 99 +/- 7.1 to 114 +/- 2.8 bpm, respectively. Mean aortic pressure, central venous pressure, and left arterial pressure did not change significantly. Also, no change was observed for the left and right pump flows. This totally implantable BVAD showed excellent long-term performance without any mechanical problems. It is feasible to operate without impairment under physical activity. However, the natural heart dominated the hemodynamic response during exercise under BVAD support. The left and the right pump flows did not increase spontaneously with exercise. We therefore conclude that a servo CO control system is necessary to regulate pump flows even during moderate exercise.
The Baylor Gyro permanently implantable centrifugal blood pump (Gyro PI pump) has been under development since 1995 at Baylor College of Medicine. Excellent results were achieved as a left ventricular assist device (LVAD) with survival up to 284 days. Based on these results, we are now focusing on the development of a biventricular assist device (BVAD) system, which requires 2 pumps to be implanted simultaneously in the preperitoneal space. Our hypothesis was that the Gyro PI pump would be an appropriate device for an implantable BVAD system. The Gyro PI 700 pump is fabricated from titanium alloy and has a 25 ml priming volume, pump weight of 204 g, height of 45 mm, and pump diameter of 65 mm. This pump can provide 5 L/min against 100 mm Hg at 2,000 rpm. In this study, 6 half-Dexter healthy calves have been used as the experimental model. The right pump was applied between the infundibular of the right ventricle and the main pulmonary artery. The left pump was applied between the apex of the left ventricle and the thoracic descending aorta. As for anticoagulation, heparin was administered at the first postoperative week and then converted to warfarin sodium from the second week after surgery. Both pump flow rates were controlled maintaining a pulmonary arterial flow of less than 160 ml/kg/min for the sake of avoidance of pulmonary congestion. Blood sampling was done to assess visceral organ function, and the data regarding pump performance were collected. After encountering the endpoint, which the study could not keep for any reasons, necropsy and histopathological examinations were performed. The first 2 cases were terminated within 1 week. Deterioration of the pump flow due to suction phenomenon was recognized in both cases. To avoid the suction phenomenon, a flexible conduit attached on the inlet conduit was designed and implanted. After using the flexible inflow conduit, the required power and the rotational speed were reduced. Furthermore, the suction phenomenon was not observed except for 1 case. There was no deterioration regarding visceral organ function, and pulmonary function was maintained within normal range except for 1 case. Even though the experimental animal survived up to 45 days with the flexible inflow conduit, an increase in power consumption due to thrombus formation behind the impeller became a problem. Lower rotational speed, which was probably produced by the effectiveness of the flexible inflow conduit, was speculated to be one of the reasons. And the minimum range of rotational speed was 1,950 rpm in these 6 BVAD cases and the previous 3 cases of LVAD. In conclusion, 6 cases of BVAD implantation were performed as in vivo animal studies and were observed up to 45 days. The flexible inflow conduit was applied in 4 of 6 cases, and it was effective in avoiding a suction phenomenon. The proper rotational speed of the Gyro PI 700 pump was detected from the viewpoint of antithrombogenicity, which is more than 1,950 rpm.
Operations on the aortic arch still remain a great challenge for cardiac surgeons and necessitate a period of cerebral blood flow interruption. lt is therefore imperative to protect the brain during this very sensitive time. Clinical as well as experimental studies have shown that the exact mechanism of neural injury seems to be multifactorial. Furthermore it is still uncertain, whether cerebral injury occurs during the interval of HCA or during reperfusion. Various strategies have been adopted in an effort to reduce neurological complications after aortic surgery. These included the use of hypothermic circulatory arrest, antegrade cerebral perfusion and retrograde cerebral perfusion. All these methods have both advantages and disadvantages. New surgical techniques such as cold reperfusion have shown promising results in animal experiments and need further clinical evaluation. One very promising pathway in preventing cerebral injury lies in pharmacological interventions.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.