Search PubMed⌕ Search

Biomedical subjects

E W Rice

Publications and source records attributed to E W Rice.

At least 37 records · Page 2Linked to original sources

Rapid glutamate decarboxylase assay for detection of Escherichia coli.

A rapid test procedure for the enzyme glutamate decarboxylase was developed for detection of Escherichia coli. The assay procedure was able to confirm the presence of E. coli in enteric broth cultures with 95% specificity for both pure cultures and environmental samples. The procedure was capable of detecting survivors among chlorine-exposed cells.

Bacteriological Techniques↗

Inactivation of Escherichia coli by titanium dioxide photocatalytic oxidation.

Titanium dioxide in the anatase crystalline form was used as a photocatalyst to generate hydroxyl radicals in a flowthrough water reactor. Experiments were performed on pure cultures of Escherichia coli in dechlorinated tap water and a surface water sample to evaluate the disinfection capabilities of the reactor. In water devoid of significant amounts of inorganic-radical scavengers, rapid cell death was observed with both pure cultures and members of the indigenous flora in a natural water sample.

Escherichia coli↗

Detection of Escherichia coli by the nutrient agar plus 4-methylumbelliferyl beta-D-glucuronide (MUG) membrane filter method.

A two-step membrane filter procedure was evaluated to determine the ability to differentiate Escherichia coli from other coliform bacteria recovered from water. M-Endo LES agar incubated at 35 degrees C for 24 +/- 2 h was used as the initial isolation medium. Membranes containing coliform colonies were transferred to nutrient agar plus 4-methylumbelliferyl beta-D-glucuronide (MUG) and incubated for an additional 4 h at 35 degrees C. Escherichia coli colonies were distinguished by fluorescence when viewed under a long-wavelength ultraviolet light. A total of 119 MUG-positive colonies were isolated from 15 water sources, of which 115 (96.6%) were identified as E. coli. An examination of 182 pure culture environmental E. coli isolates revealed that 167 isolates (91.8%) exhibited fluorescence on the nutrient agar plus MUG medium. Survivors of E. coli cultures exposed to chlorination were also capable of producing a positive MUG reaction.

Bacterial Typing Techniques↗

Serological cross-reactions between Escherichia coli O157 and other species of the genus Escherichia.

The antigenic relatedness of Escherichia coli O157 and four sorbitol-negative species of the genus Escherichia was examined. Isolates of Escherichia hermannii, E. fergusonii, E. vulneris, and E. blattae were tested in the tube agglutination assay by using polyclonal antisera and in the slide agglutination assay by using latex reagents. Only four isolates (17%) of E. hermannii exhibited serological cross-reactivity.

Cross Reactions↗

Cholera in Peru.

Explore the source record for details and available documents.

Cholera↗

Assay for beta-glucuronidase in species of the genus Escherichia and its applications for drinking-water analysis.

Recently, Escherichia species other than Escherichia coli have been isolated from potable water. Environmental isolates as well as clinical isolates of E. adecarboxylata, E. blattae, E. fergusonii, E. hermannii, and E. vulneris were assayed for the enzyme beta-glucuronidase by using EC MUG medium and the Colilert system. None of the isolates were positive for the enzyme by either method.

Escherichia↗

Evaluation of beta-glucuronidase assay for the detection of Escherichia coli from environmental waters.

The new United States Drinking Water Regulations state that water systems must analyze for Escherichia coli or fecal coliforms on any routine or repeat sample that is positive for total coliforms. The proposed methods for the detection of E. coli are based on beta-glucuronidase activity, using the fluorogenic substrate 4-methylumbelliferyl beta-D-glucuronide (MUG). This study was conducted to determine whether beta-glucuronidase negative E. coli were present in significant numbers in environmental waters. Two hundred and forty E. coli cultures were isolated from 12 water samples collected from different environmental sources. beta-glucuronidase activity was determined using lauryl tryptose broth with MUG, EC broth with MUG, and the Autoanalysis Colilert (AC) procedure. The isolates were also evaluated by the standard EC broth gas fermentation method for fecal coliforms. The results confirm that assaying for the enzyme beta-glucuronidase utilizing the MUG substrate is an accurate method for the detection of E. coli in environmental waters.

Enterobacteriaceae↗

Efficacy of beta-glucuronidase assay for identification of Escherichia coli by the defined-substrate technology.

In 1976, Kilian and Bulow described the association of beta-glucuronidase with the genus Escherichia (97% positive) and suggested that a beta-glucuronidase assay would be a useful identification test. Since that report, papers about the sensitivity and specificity of this enzyme for the identification of Escherichia coli from clinical sources, food, seawater, potable-water supplies, and various environmental sources have appeared. A study was undertaken to determine the efficacy and specificity of the defined-substrate technology beta-glucuronidase (Colilert) assay for the identification of this species from fecal samples. A total of 460 human, 105 cow, and 55 horse E. coli isolates were tested. Results showed 95.5% beta-glucuronidase-positive isolates in 24 h and 99.5% positive after 28 h of incubation. Only one E. coli isolate was negative. There were no significant differences in the percentage of beta-glucuronidase-positive isolates among the human or animal isolates. There were no non-E. coli isolates that were positive. All subjects carried beta-glucuronidase-positive E. coli.

Animals↗

Evaluation of the Autoanalysis Colilert test for detection and enumeration of total coliforms.

The Autoanalysis Colilert (AC) test was compared with the membrane filter (MF), 10-tube multiple-tube fermentation (MTF) technique, and the presence-absence test as described in Standard Methods for the Examination of Water and Wastewater for the detection and enumeration of total coliforms in water. The methods were evaluated with 31 samples from seven different sources. Each sample was analyzed by each of the techniques, using replicate 100-ml sample volumes. A total of 582 confirmed tubes were positive by the MTF test, and 533 tubes were positive by the AC test. Statistical analysis of the most-probable-number comparability data showed a statistically significant difference in the number of positive tubes, with the MTF test resulting in more positive tubes. There were no statistically significant differences in precision between the two methods. All the methods were comparable in detection of total coliforms. Levels of heterotrophic bacteria generally encountered in drinking water did not interfere with detection or enumeration of coliforms by the AC test.

Colony Count, Microbial↗

Inactivation of particle-associated coliforms by chlorine and monochloramine.

Sieves and nylon screens were used to separate primary sewage effluent solids into particle fractions of less than 7- or greater than 7-micron size. The efficiency of separation was determined by using a particle counter. Indigenous coliforms associated with the particle fractions were tested for their resistance to chlorine and monochloramine. Coliforms associated with the less than 7-microns fraction were inactivated more rapidly by 0.5 mg of chlorine per liter at 5 degrees C and pH 7 than coliforms associated with the greater than 7-microns fraction. Homogenization of the greater than 7-microns fraction not only resulted in an increase in the number of less than 7-microns particles, but also increased the rate of inactivation to a rate similar to that of the less than 7-microns fraction. With 1 mg of monochloramine per liter at 5 degrees C and pH 7, particle size had no appreciable effect on the rate of inactivation. At pH 8, however, the less than 7-micron fraction was inactivated more rapidly than the greater than 7-micron fraction. The time required for 99% inactivation of the particle fractions with monochloramine at pH 7 or 8 was 20- to 50-fold greater than the time required for the same amount of inactivation with chlorine at pH 7. The results indicate that coliforms associated with sewage effluent particles are inactivated more rapidly with 0.5 mg of chlorine per liter than with 1.0 mg of monochloramine per liter. However, greater than 7-micron particles can have a protective effect against the disinfecting action of chlorine.

Chloramines↗

Comparison of media for recovery of total coliform bacteria from chemically treated water.

Five broth media and two solid media were compared for their ability to quantitatively recover total coliform bacteria from chemically treated water. M-Endo LES and mT7 media were used in the membrane filter technique. Lauryl tryptose broth, lactose broth, presence-absence broth, lactose broth with twice the amount of lactose, and lauryl tryptose broth with twice the amount of sodium lauryl sulfate were used in the fermentation tube procedure. The differences in recovery were not significant for the five broth media and M-Endo LES agar. The M-Endo LES and mT7 media were not significantly different; however, the five broth media did yield significantly higher counts than mT7.

Analysis of Variance↗

Comparison of membrane filter, multiple-fermentation-tube, and presence-absence techniques for detecting total coliforms in small community water systems.

Methods for detecting total coliform bacteria in drinking water were compared using 1,483 different drinking water samples from 15 small community water systems in Vermont and New Hampshire. The methods included the membrane filter (MF) technique, a 10-tube fermentation tube (FT) technique, and the presence-absence (P-A) test. Each technique was evaluated using a 100-ml drinking water sample. Of the 1,483 samples tested, 336 (23%) contained coliforms as indicated by either one, two, or all three techniques. The FT detected 82%, the P-A detected 88%, and the MF detected 64% of these positives. All techniques simultaneously detected 55% of the positives. Evaluation of the confirmation efficiency of the P-A technique showed 94% of the presumptive positives confirming as coliforms. Thirteen different species of coliforms were identified from the 37 tests in which the P-A was positive but the MF and FT were negative. The P-A test was simple to inoculate and interpret and was considerably more sensitive than the MF and slightly more sensitive than the FT in detecting coliforms in this type of drinking water supply.

Bacteriological Techniques↗

Comparison of animal infectivity and excystation as measures of Giardia muris cyst inactivation by chlorine.

In this study, in vitro excystation and mouse infectivity were compared as methods for quantitatively determining the viability of Giardia muris cysts before and after exposure to free residual chlorine. The mouse infectivity results show that very few cysts (1 to 15) constitute an infectious dose. The results of the inactivation studies indicate that in vitro excystation is an adequate indication of G. muris cyst infectivity for the host and can be used to determine the effects of disinfectants on cyst viability.

Animals↗

Factors promoting in vitro excystation of Giardia muris cysts.

Giardia muris cysts, isolated from mouse faeces, excysted routinely at levels greater than 90%, when induced in 1X Hanks' supplemented with 17 mM glutathione, 29 mM L-cysteine-HCl, and 50 mM NaHCO3 for 30 minutes at 35 degrees C, followed by washing and suspension in trypsin-Tyrode's solution at pH 8.0. Although trypsin was not required in this final step, it enhanced the escape of the trophozoites from their cysts. G. muris excystation was dependent upon the length of the induction period, pH, oxidation-reduction potential and temperature. Optimal induction conditions for excystation were: an induction period of 5 to 30 min; pH of 2; 120 mV oxidation-reduction potential; and a temperature around 35 degrees C. A gradual decline in excystation occurred as pH and oxidation-reduction potential were changed to 7 and 57 mV, respectively. There was a pronounced increase in excystation percentages with increasing temperatures between 0 and 37 degrees C. At 40 degrees C and above, the G. muris cysts showed signs of inactivation. The thermal death point of G. muris cysts was determined to be about 54 degrees C. G. muris cysts showed no polarity; however, the tail or posterior trophozoite portion always emerged through one end of the cyst first. Cytokinensis began within the first hour after excystation. This method always produced extremely active, normal-looking G. muris trophozoites.

Animals↗