Six years experience in intracoronary brachytherapy procedures: patient doses from fluoroscopy.

Typical patient dose levels during intracoronary brachytherapy (ICB) procedures using beta sources were determined across a sample of 221 treatments. Dose-area product values, fluoroscopy time and number of frames per procedure, with median values of 62 Gy cm2, 17.0 min and 1493 images, respectively, resulted in a 20% to 50% increase in the values measured for percutaneous transluminal coronary angioplasty procedures in the same medical centre (median values 41 Gy cm2, 14.3 min and 1078 images). Likely reasons for this increase include the additional complexity of ICB, the need for recording and reporting every step of the treatment, getting the essential parameters for the volume determination of the lesion and therapeutic radiation dose calculation and, finally, the learning curve for this kind of procedure. A high concentration skin dose distribution during ICB procedures was measured and in 12% of the patients peak skin doses higher than 1.5 Gy were confirmed. 10 patients were submitted to clinical follow-up and skin injuries were not identified.

Angioplasty, Balloon, Coronary↗

Does digital imaging decrease patient dose? A pilot study and review of the literature.

The potential for decreasing patient dose is one of the main arguments for the justification of the cost of digital imaging equipment. However, the literature review with respect to patient doses using digital imaging modalities, presents conflicting results. During this study, patients' entrance surface doses were measured for three simple radiographic examinations, in European centres equipped with a computed radiography digital system. Results showed that doses between centres varied from 30% for chest LAT to 250% for chest PA examination. With the digital image quality criteria still under discussion, and with the post-processing parameters and/or image documentations varying, any dose comparisons between conventional/digital systems, as well as dose comparisons between different centre using digital units, are difficult. Clinical trials are required in order to define reference levels associated with quality of digital image necessary to address specific clinical requirements.

Humans↗

Accreditation in radiation protection for cardiologists and interventionalists.

Training in radiation protection is widely recognised as one of the basic components of optimisation programmes for medical exposures. Occupational and patient radiation risks in interventional radiology can be quite high and international bodies have shown concern on this item. Following recommendations of the International Commission on Radiological Protection and in accordance with the European Directive on medical exposures, some initiatives for training in radiation protection took place in Spain and Luxembourg. These provided practitioners of interventional radiology adequate theoretical and practical training in radiation protection. The main outcome of the pilot courses organised to this end is discussed, concluding its suitability to implement the European Directive in practice.

Accreditation↗

ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.

The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protection for cardiologists performing fluoroscopically guided procedures, will be produced during 2005. This paper highlights some of the topics of the published reports, their relevance to European legislation on medical exposures and the importance of radiation protection research in underpinning the ICRP task groups' work in to producing these documents. It is also anticipated that the results, obtained in the cardiology work package of the European research project, will be used in the new document on radiation protection for cardiologists.

Heart↗

A study to validate the method based on DIMOND quality criteria for cardiac angiographic images.

A method based on image quality criteria (QC) for cine-angiography was developed to measure the quality of cine-angiograms (CA). A series of 30 CA for left ventriculography (LV) and left and right coronary angiography (LCA, RCA) have been scored and 172 readings were obtained. Standard deviation of quality scores indicated the reproducibility of the method. Each part of CA was examined separately, giving scores for LV, LCA and RCA and a total score (TS), with clinical (C) and technical (T) criteria defined and examined separately. In 83% of the studies TS was >0.8 and with standard deviation from 0.02 to 0.21. In general, LV had a lower score and greater disagreement compared with RCA and LCA. Disagreement was greater in T, compared with C. In conclusion, these results indicate that QC, translated into a scoring system, yields reproducible data on the quality of cardiac images.

Cineangiography↗

Correlation of patient and staff doses in interventional cardiology.

The purpose of this study was to measure staff radiation doses in representative institutions of five European countries performing coronary angiographies (CA) and percutaneous transluminal coronary angioplasties (PTCA), as well as to investigate any correlation with patient doses. Patient doses were recorded in terms of dose-area product (DAP). Staff doses were measured by thermoluminescence dosemeters placed on the operator's left shoulder and left foot. Radiation protection measures were also recorded. Third quartile shoulder and foot doses were 90 and 66 microSv in CA, and 157 and 173 microSv in PTCA, respectively. Shoulder dose was poorly correlated with DAP in CA (R2 = 0.29) and only moderately correlated in PTCA (R2 = 0.69). DAP and foot dose correlation was poor both in CA (R2 = 0.16) and in PTCA (R2 = 0.02). Protective measures taken by staff varied between countries, which may explain the poor correlation of patient and staff radiation doses.

Angioplasty, Balloon, Coronary↗

The application of image quality measurements for digital angiography.

The image quality (IQ) evaluation of a charge-coupled device (CCD)-based digital angiography system was assessed with respect to modulation transfer function and noise power spectrum. These values were used to calculate the system's frequency-dependent detective quantum efficiency (DQE). The X-ray image detector was an image intensifier (II) lens coupled to a CCD camera. Two measurement setups were used. Setup A is standard IQ assessment, while Setup B more closely represented clinical conditions (polymethyl methacrylate (PMMA) of varying thickness placed between the X-ray tube and II, with test object positioned between PMMA slices 30 cm from the II). Exposure parameters varied according to automatic brightness control settings. Setup B included X-ray radiation scattered by the patient-PMMA. A clinical DQE, describing the transmission of the input signal-to-noise ratio associated with both primary and secondary X-ray spectra, was defined.

Angiography↗

Evaluation of risk of deterministic effects in fluoroscopically guided procedures.

A methodology for the evaluation of skin dose distribution and possible skin injuries on patients undergoing interventional procedures has been developed as part of the European DIMOND programme. Relevant dosimetric data from the procedures are recorded and other specific measurements for skin dose evaluation (slow films for therapy, radiochromic films, thermoluminescence dosemeters and optically stimulated luminescence dosemeters) have been carried out. For non-cardiac and for some cardiac procedures, dose-area product values of 200 and 300 Gy cm2 were proposed, respectively, as a trigger level for further detailed skin dose investigation and possible clinical follow-up. Results from a survey of 191 selected complex procedures are reported. Out of all the patients included in the trial, 16% received skin doses > or =1.5 Gy. No skin injuries were found in any of the patients followed.

Dose-Response Relationship, Radiation↗

Patient dosimetry and image quality in digital radiology from online audit of the X-ray system.

The present work describes an online patient dosimetry and an image quality system in digital radiology. For the patient dosimetry audit, current mean values of entrance surface dose (ESD) were compared with local and national reference values (RVs) for the specific examination type evaluated. Mean values exceeding the RV trigger an alarm signal and then an evaluation of the technical parameters, operational practice and image quality was begun, using data available in the DICOM header to derive any abnormal settings or performance to obtain the image. The X-ray tube output for different kVp values is measured periodically, to allow for the automatic calculation of ESD. The system allows also for image audit, linking the dose imparted, the image quality and the alarm condition, if produced. Results and the benefits derived from this online quality control are discussed here.

Humans↗

On the use of DICOM cine header information for optimisation: results from the 2002 European DIMOND cardiology survey.

The paper explores the level of information contained within the DICOM header in images from various cardiology systems. Data were obtained in the European DIMOND survey on image quality (Italy, Ireland, Belgium, Greece and Spain). Images from five standard diagnostic cardiology procedures carried out in six European hospitals have been analysed. DICOM header information was extracted to a database in order to analyse how it could help in the optimisation of the procedures. The level of data contained in the headers differs widely between cardiology systems. None of the X-ray systems in the 2002 survey archives the dosimetric data in the DICOM header. The mean number of runs per procedure ranges between 7.5 and 15.4 and the mean number of frames per procedure between 575 and 1417. Differences in kVp, mA, pulse time, distances and C-arm angulations are substantial and suggest that there exists a wide range for optimisation.

Cardiology↗

Patient dosimetry in diagnostic and interventional radiology: a practical approach using trigger levels.

Patient dosimetry is performed in radiology and interventional radiology to assess whether deterministic injuries may occur and to establish the risk of stochastic effects. A fundamental problem for patient dosimetry is that no single quantity can be used to accurately assess both the risk of stochastic effects and whether deterministic injuries will occur following a specific examination or procedure. In cardiology and interventional radiology, two different approaches to patient dosimetry are commonly used. Effective dose is a quantity which correlates reasonably well with the risk of stochastic effects. Effective dose may be deduced from the dose-area product (DAP) for the procedure if sufficient information is known. DAP does not correlate with maximum skin dose, which may be used to predict whether deterministic injuries may occur. DAP meter readings may be used as a trigger level for the investigation of maximum skin entrance dose. Trigger levels for different procedures are proposed.

Humans↗

Image quality criteria in cardiology.

Image quality evaluation plays a key role in the process of optimisation in radiological procedures. Image quality criteria for cardiac cine-angiography were recently agreed as part of a European Research Project, and a scoring system based on these criteria has been developed to allow an 'objective' measurement of the quality of cardiac angiograms. Two studies aimed at the evaluation of the methodology have been completed, demonstrating that the method can be applied to cardiac images and translated into a scoring system that yields reproducible data. Based on the results of these studies, quality criteria have been further reviewed by DIMOND III panel and the updated version is presented in this paper.

Cardiology↗

Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology.

Patient and staff dose values in an interventional cardiology laboratory for different operational modes and several patient thicknesses (from 16 to 28 cm, simulated using polymethylmethacrylate) are presented. When increasing patient thicknesses and depending on fluoroscopy and cine modes, occupational doses can increase >30 times the baseline level. Scatter dose rates at the cardiologist's position with no radiation protective tools ranged from 1 to 14 mSv h(-1) for fluoroscopy, and from 10 to 47 mSv h(-1) during cine acquisition. Patient entrance surface air kerma rates increased by nearly 3 and staff dose rates by up to 2.6 when fluoroscopy was moved from the low to the high mode, for a typical 20 cm thickness. The respective increase factors were 6 and 4.2 when patient thickness rose from 16 to 28 cm, and by 10 and 8.3, when comparing cine acquisition with the low fluoroscopy mode. The knowledge of typical dose rates for each X-ray system in use in catheterisation laboratories is essential in order to optimise protection of patients and staff.

Body Constitution↗

Dynamic flat panel detector versus image intensifier in cardiac imaging: dose and image quality.

The practical aspects of the dosimetric and imaging performance of a digital x-ray system for cardiology procedures were evaluated. The system was configured with an image intensifier (II) and later upgraded to a dynamic flat panel detector (FD). Entrance surface air kerma (ESAK) to phantoms of 16, 20, 24 and 28 cm of polymethyl methacrylate (PMMA) and the image quality of a test object were measured. Images were evaluated directly on the monitor and with numerical methods (noise and signal-to-noise ratio). Information contained in the DICOM header for dosimetry audit purposes was also tested. ESAK values per frame (or kerma rate) for the most commonly used cine and fluoroscopy modes for different PMMA thicknesses and for field sizes of 17 and 23 cm for II, and 20 and 25 cm for FD, produced similar results in the evaluated system with both technologies, ranging between 19 and 589 microGy/frame (cine) and 5 and 95 mGy min(-1) (fluoroscopy). Image quality for these dose settings was better for the FD version. The 'study dosimetric report' is comprehensive, and its numerical content is sufficiently accurate. There is potential in the future to set those systems with dynamic FD to lower doses than are possible in the current II versions, especially for digital cine runs, or to benefit from improved image quality.

Air↗

ICRP recommendations on 'Managing patient dose in digital radiology'.

The International Commission on Radiological Protection (ICRP) approved the publication of a document on 'Managing patient dose in digital radiology' in 2003. The paper describes the content of the report and some of its key points, together with the formal recommendations of the Commission on this topic. With digital techniques exists not only the potential to improve the practice of radiology but also the risk to overuse radiation. The main advantages of digital imaging: wide dynamic range, post-processing, multiple viewing options, electronic transfer and archiving possibilities are clear but overexposures can occur without an adverse impact on image quality. It is expected that the ICRP report helps to profit from the benefits of this important technological advance in medical imaging with the best management of radiation doses to the patients. It is also expected to promote training actions before the digital techniques are introduced in the radiology departments and to foster the industry to offer enough technical and dosimetric information to radiologists, radiographers and medical physicists to help in the optimisation of the imaging.

Body Burden↗

Reference level for patient dose in dental skull lateral teleradiography.

The present work describes an experiment to obtain a local reference dose value in lateral skull teleradiography for dental applications. The reference value was based on patient measurements in seven dental X-ray units, using thermoluminescent chips, and measurements on a rubber globe filled with water at another 78 installations. Dosemeters were located initially in the head and neck of a human phantom to select the most suitable locations, and on the cephalostat of the X-ray unit at two appropriate locations, which did not interfere with the patient or with the usual imaging routine. The skin projection of the Porion point was considered the best position. 523 patients were monitored in the seven units; then patient doses and dose values from measurements on rubber balloons were compared to normalize and combine the data. The provisional reference value proposed is 400 microGy.

Humans↗

Comparison of a conventional and a flat-panel digital system in interventional cardiology procedures.

The purpose of the study was to analyse the technical characteristics of a newly installed flat-panel fluoroscopy (FPF) system in an interventional cardiology (IC) department and compare it with an older conventional system. A patient survey was performed to investigate the radiation doses delivered by the X-ray systems. Finally, methods of technique optimization regarding the new digital system were investigated. Dose rates in all fluoroscopic and cine modes were measured and image quality assessed using a dedicated test tool. 200 patients were investigated, half using the conventional and half using the digital FPF system. Patient data collected were: sex, age, weight, height, dose-area product (DAP), fluoroscopy time (T) and total number of frames (F). Our results are: (1) Digital FPF system: high contrast resolution (HCR) is not affected by fluoroscopic mode, whereas low contrast resolution (LCR) is slightly decreased in the low mode. (2) The digital FPF system has 2.5 times better HCR than the conventional system, with 5 times lower dose in the fluoroscopy mode. (3) Median values of DAP, T and F, respectively, in coronary angiography (CA) are: 27.7 Gycm(2), 4.1 min and 876 for the digital and 39.3 Gycm(2), 5.3 min and 1600 for the conventional system. Median values for percutaneous transluminal coronary angioplasty (PTCA) are: 51.1 Gycm(2), 12.7 min and 1184 for the digital and 44.3 Gycm(2), 7.4 min and 1936 for the conventional system. Digital DAP in CA is reduced by 30%, suggesting that a dose reduction in the FPF system is possible. The results of the study concerning the FPF system lead to the conclusion that the lowest fluoroscopic mode and the lowest frame rate should be used in routine practice.

Angioplasty, Balloon, Coronary↗

Preliminary reference levels in interventional cardiology.

This article describes the European DIMOND approach to defining reference levels (RLs) for radiation doses delivered to patients during two types of invasive cardiology procedures, namely coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA). Representative centres of six European countries recorded patients' doses in terms of dose-area product (DAP), fluoroscopy time and number of radiographic exposures, using X-ray equipment that has been subject to constancy testing. In addition, a DAP trigger level for cardiac procedures which should alert the operator to possible skin injury, was set to 300 Gyxcm2. The estimation of maximum skin dose was recommended in the event that a DAP trigger level was likely to be exceeded. The proposed RLs for CA and PTCA were for DAP 45 Gyxcm2 and 75 Gyxcm2, for fluoroscopy time 7.5 min and 17 min and for number of frames 1250 and 1300, respectively. The proposed RLs should be considered as a first approach to help in the optimisation of these procedures. More studies are required to establish certain "tolerances" from the proposed levels taking into account the complexity of the procedure and the patient's size.

Angioplasty, Balloon, Coronary↗