Search PubMed⌕ Search

Biomedical subjects

E Ujec

Publications and source records attributed to E Ujec.

At least 37 records · Page 2Linked to original sources

Response to stretch of proprioceptors in adult rat muscles de-efferented at birth.

Hind-limb muscles of new-born rats were de-efferented by removing the lumbosacral spinal cord. Spinal ganglia remained intact, together with their peripheral axon. The presence of sensory terminals in limb spindles, induces the full ultrastructural differentiation of muscle spindles, as has been shown previously. In the present paper we have shown by integrating the sensory discharges in the whole nerve from chronically de-efferented muscles that even several months after birth, muscle proprioceptors (probably mostly spindles) still maintain their basic mechanoreceptor properties. Although the limbs were completely immobilized throughout the whole experimental period, spindles from these chronically de-efferented muscles still responded as slowly adapting receptors. The dynamic component was also present in the integrated neurogram response during stretching. It thus appears that basic functional properties of rat muscle proprioceptor persist even when these receptors differentiate and survive without motor innervation and any adequate functional stimuli, i.e. under conditions of permanent disuse.

Animals↗

Work-induced potassium changes in skeletal muscle and effluent venous blood assessed by liquid ion-exchanger microelectrodes.

Using liquid ion-exchanger semimicroelectrodes with a side pore, we measured changes of extracellular potassium concentration (Ke+) in adult rabbit and cat gastrocnemius muscles and in venous effluent blood flowing from the cat gastrocnemius muscle during various bouts of activity induced by sciatic nerve stimulation. 1. Isometric tetanic contractions (at 50 Hz) of various durations caused transient accumulation of Ke+ which was non-linearly related to the duration of muscle activity. The peak values of Ke+ in response to muscle stimulation were analogous in rabbits and cats, attaining values, e.g. after a 20-sisometric tetanus, between 8-9 mEq/1K+ in both species. 2. Potassium concentration in venous effleunt blood (K+ven) was transiently increased after isometric tetani. Since blood flow was measured at the same time, it was possible to calculate the amount of K+ lost by the muscle after tetani of various durations. A 32 g gastrocnemius muscle of the cat, for example, loses 9.36 +/- 1.52 muEqK+ after a 20-s isometric tetanus, which corresponds roughly to 0.5% of the total muscle potassium content. The loss of K+ in this muscle was 29.3 pEq K+ /impulse/100 g fresh muscle tissue. 3. There was no evident difference between the amount of K+ released during isometric tetani, or tetanic contractions performed under isotonic conditions. Single twitches evoked by indirect stimulation at 1 HZ for several minutes also induced a small rise in K+ven. 4. If the loss of K+ from the muscle into the blood stream is transiently prevented by arterio-venous occlusion installed immediately before a 10-s isometric tetanus, most K+ is released subsequently when blood flow is renewed, if the occlusion lasts for 20-25 s. It is not until blood flow is occuded for 40-60 s that most K+ is apparently resorbed and only a minor portion is released and is to be found in the venous blood. 5. The transient accumulation of muscle extra-cellular potassium may locally affect nerve endings, skeletal and smooth muscle cells.

Animals↗

Changes of extracellular potassium concentration induced by neuronal activity in the sinal cord of the cat.

1. Changes of extracellular K(+) concentration, [K](e), arising in the spinal cord of the cat in response to an afferent stimulation were studied by means of K(+)-specific micro-electrodes.2. In the most active areas of the spinal cord a single volley in a large afferent input like the common peroneal nerve or the posterior tibial nerve produced a transient increase in [K](e) of 0.05-0.1 mM, which reached its peak in 0.2-0.3 sec and it declined in about 3 sec.3. Much higher increases in [K](e) were found during repetitive stimulation of an afferent input. The highest increase (by 3 mM) was at 100 Hz, but even at 1 Hz a significant increase of 0.25 mM was observed. Equilibration of accumulated K(+) was slow with a time constant of about 6 sec, which is much longer than could be expected for the same process in free solution.4. A characteristic distribution of increased [K](e) was found in the spinal cord in response to 100 Hz afferent stimulation. The highest increase of 3 mM was found in and around the intermediate nucleus, but at depths between 0.9-1.8 mm the [K](e) increase exceeded 1 mM.5. In the ventral horns afferent stimulation (100 Hz) increased [K](e) by 0.25 mM, while the same stimulation of the ventral root resulted in a [K](e) increase of less than 0.05 mM.6. The consequences of K(e) (+) accumulation after neuronal discharge are discussed in respect to its possible role in the depolarization of primary afferent terminals.

Animals↗