Plasma and urinary levels of heart fatty acid-binding protein in patients undergoing cardiac surgery.

To evaluate the clinical significance of the plasma and urinary levels of heart fatty acid-binding protein (H-FABP) in patients undergoing cardiac surgery, a prospective study was conducted. Ten patients undergoing coronary artery bypass grafting were enrolled. Blood samples for determination of plasma H-FABP (pH-FABP), the MB isoenzyme of creatine kinase (CK-MB) and troponin-T (TnT), and urine samples for determination of urinary H-FABP (uH-FABP) were collected serially. None of the patients had perioperative myocardial infarction. The time to reach the peak level after aortic declamping was significantly (p<0.05) shorter for pH-FABP (1.4+/-0.5 h) than for CK-MB (2.5+/-0.5 h), TnT (6.6+/-1.3 h) or uH-FABP (3.0+/-0.6 h). Peak levels of pH-FABP correlated with those of CK-MB (r = 0.51, p = 0.04), TnT (r = 0.60, p = 0.03) and uH-FABP (r = 0.61, p = 0.03), and peak levels of uH-FABP correlated with CK-MB (r = 0.57, p = 0.04). Postoperative uH-FABP levels correlated inversely with the left ventricular stroke work index (r = -0.63, p = 0.04). This study demonstrated that H-FABP appears rapidly in plasma after reperfusion and reaches its peak earlier than other available biochemical markers; it appears also in urine and the levels correlated with cardiac function. Plasma and urinary H-FABP may be an early and sensitive biochemical marker for the diagnosis of myocardial injury in patients undergoing cardiac surgery.

Blood Pressure↗

Plasma exchange for hyperbilirubinemia following implantation of a left ventricle assist system: a case report.

A 49-year-old patient with end-stage dilated cardiomyopathy underwent implantation of a left ventricular assist system (LVAS). Although the systemic circulation seemed to be improved, the serum total bilirubin (Tbili) level increased sharply in the early postoperative period (preoperative Tbili, 5.7 mg/dl; postoperative day 3, 33.6 mg/dl). Plasma exchange (PE) was performed 7 times from postoperative day 4, and the Tbili level decreased to 16.3 mg/dl by postoperative day 11. Thereafter, serum Tbili normalized concomitant with improved circulatory condition. The cause of the hyperbilirubinemia was considered to be temporary right ventricular dysfunction or hepatic sinusoid endothelial dysfunction. The liver function was recoverable, so PE had been effective in this case. Unfortunately, the patient suffered a midbrain infarction and ultimately died. From this experience, PE is recommended if it is judged that liver function can be preserved and circulation is adequate, but its implementation should not be delayed. It is essential that LVAS is implanted before damage occurs to end-organ function and thus prevent hyperbilirubinemia.

Cardiomyopathy, Dilated↗

Successful removal of an infected pacemaker electrode by open heart surgery under extracorporeal circulation.

A 33-year-old male with sick sinus syndrome, who had received a pacemaker implant 18 years earlier, was complicated with a generator infection. Although the infected generator was removed, he was suffered from the recurrent local infection associated with a retained pacemaker lead. After a new pacemaker system implantation from the other side of the subclavian vein, we attempted to remove the lead utilizing a pacemaker removal kit. However, this intervention procedure was unsuccessful, because fibrous adhesions had developed around the lead, accompanied by calcification along its course. As a last resort, we opened the heart under extracorporeal circulation and removed the lead under direct vision. The post-operative course was uneventful. In order to remove a long-term implanted pacemaker lead, the direct surgical procedure with extracorporeal circulation is a favorable mean alternative to conventional intervention techniques.

Adult↗

Effects of supplemental L-arginine during warm blood cardioplegia.

OBJECTIVES: Effects of supplemental L-arginine, nitric oxide precursor, during warm blood cardioplegia were assessed in the blood perfused isolated rat heart. METHODS: The isolated hearts were perfused with blood at 37 degrees C from a support rat. After 20 minutes of aerobic perfusion, the hearts were arrested for 60 minutes with warm blood cardioplegia given at 20-minute intervals. This was followed by 60 minutes of reperfusion. The hearts were divided into the following three groups according to the supplemental drugs added to the cardioplegic solution. The control group (n = 10) received standard warm blood cardioplegia. The L-ARG group (n = 10) received warm blood cardioplegia supplemented with L-arginine (3 mmol/l). The L-NAME group (n = 10) received warm blood cardioplegia supplemented with L-arginine (3 mmol/l) and L-nitro-arginine methyl ester, a competitive inhibitor of nitric oxide synthase (1 mmol/l). After 60 minutes of cardioplegic arrest, cardiac function, myocardial metabolism and myocardial release of circulating adhesion molecules were measured during reperfusion. RESULTS: Left ventricular end-diastolic pressure was significantly lower (p<0.05) in the L-ARG group than in the control group and the L-NAME group during reperfusion. Isovolumic left ventricular developed pressure, dp/dt and coronary blood flow were significantly greater (p< 0.05) in the L-ARG group during reperfusion. The L-ARG group resulted in early recovery of lactate metabolism during reperfusion. Myocardial release of circulating intercellular adhesion molecule-1 (ICAM-1) and E-selectin were significantly less (p<0.05) in the L-ARG group at 15 minutes of reperfusion. CONCLUSIONS: The results suggest that augmented nitric oxide by adding L-arginine to warm blood cardioplegia can preserve left ventricular function and ameliorate endothelial inflammation. The technique can be a novel cardioprotective strategy in patients undergoing cardiac surgery.

Animals↗

A case report of surgical treatment of quadricuspid aortic valve associated with regurgitation.

A case of a 65-year-old woman who had a quadricuspid aortic valve associated with aortic regurgitation is reported. The patient had severe aortic regurgitation and four equally divided aortic cusps. The valve abnormality was detected by a transesophageal echo and an aortography. The incomplete aortic valve was excised and replaced by a St. Jude Medical prosthesis. Although this case had no coronary abnormality, a coronary displacement is often reported in quadricuspid aortic valve cases. In order to perform an operation safely, accurate information which is obtained by a non-invasive examination of the transesoph-ageal echo is quite valuable as it can indicate the need for further preoperative examinations of the coronary arteries.

Aged↗

ATS prosthetic valve motion: an in vitro analysis.

BACKGROUND AND AIM OF THE STUDY: We have reported clinical findings that normally functioning open pivot ATS valves did not open completely. In order to analyze features of the ATS valve motion more precisely, in vitro tests were conducted. METHODS: Opening angles and pressure gradients of the ATS valve were measured and compared with those of the St. Jude Medical (SJM) valve under steady flow, but with various outlet configurations. Second, opening angles of the two valves were measured under pulsatile conditions in two different outflow configurations: (i) a 'straight outlet' where the leaflets did not extend into the tapering outflow chamber, and (ii) an 'abrupt enlargement outlet' where the leaflets extended directly into the enlarged outflow space. Third, flow visualization studies were made under steady flow conditions in the straight and abrupt enlargement outlet conduits, respectively. RESULTS: Under steady flow conditions, opening of the ATS valve was restricted in most outflow configurations; only when the outlet angle was 0 degrees did the valve open fully. The SJM valve opened completely in all downstream configurations. Despite restricted opening in the ATS valve, the pressure gradient was similar in both valves. Under pulsatile conditions, both valves opened fully in the straight outlet; however, in the abrupt enlargement outlet the ATS valve opened incompletely and the SJM valve completely. Substantial turbulent flow was observed at the outside of the leaflet and corners of the conduit, notably with the ATS valve. CONCLUSION: This study showed that the ATS valve did not open fully except when the outflow was straight, and the leaflet did not extend into an enlarged downstream chamber. Structural features of the ATS, such as its axis being located close to the straight edge and its leaflets extending further downstream from the ring orifice, may cause this unique valve behavior.

Heart Valve Prosthesis↗

Concentric wear of the Delrin disc in a Bjork-Shiley heart valve prosthesis: report of two cases.

We report herein the cases of two patients who received replacement of aortic Bjork-Shiley Delrin (BSD) valves that had been implanted for over 20 years following the development of aortic regurgitation (AR) resulting from wear of a Delrin disc. Case 1 was a 61-year-old woman in whom echocardiography revealed marked left ventricular dilatation and moderate AR 23 years after an aortic valve replacement (AVR) with a 21-mm BSD valve. Case 2 was a 51-year-old woman in whom echocardiography revealed marked dilation of the right atrium and moderate AR 23 years and 8 months after an AVR with a 21-mm BSD valve, as well as a mitral valve replacement with a 3M Starr-Edwards (SE) ball valve and tricuspid annuloplasty. In both patients, the BSD valves were replaced with other mechanical valves at reoperation. Examination of the explanted BSD valves showed that the Delrin discs contained increases in the radial gaps and strut indentation grooves on the inflow and outflow surfaces. The type and magnitude of the wear on the Delrin discs in these valves were consistent with data reported in the literature for this valve design after similar implant duration.

Aortic Valve↗

Inhibitory effect of milrinone on cytokine production after cardiopulmonary bypass.

BACKGROUND: It has been suggested that cyclic adenosine monophosphate-elevating agents suppress cytokine production. To evaluate the effects of milrinone, a phosphodiesterase III inhibitor, on cytokine production after cardiopulmonary bypass, we conducted a prospective randomized study. METHODS: Twenty-four patients undergoing coronary artery bypass grafting were randomized to receive either milrinone treatment (milrinone, n = 12) or no milrinone treatment (control, n = 12). Administration of milrinone (0.5 microg x kg(-1) x min(-1)) was started after induction of anesthesia and was continued for 24 hours. Blood samples for determination of plasma cyclic adenosine monophosphate, tumor necrosis factor-alpha, interleukin-1beta, interleukin-6, and interleukin-8 levels were collected perioperatively. RESULTS: No significant differences were observed in tumor necrosis factor-alpha and interleukin-8 levels between the groups. Interleukin-1beta and interleukin-6 levels after cardiopulmonary bypass were significantly (p < 0.05) lower in the milrinone group than in the control group. Plasma levels of cyclic adenosine monophosphate increased significantly (p < 0.05) after the administration of milrinone and the levels correlated inversely (r = -0.55, p < 0.01) with interleukin-6 levels. CONCLUSIONS: The results indicate that milrinone suppresses cytokine production by elevating cyclic adenosine monophosphate levels in patients undergoing cardiopulmonary bypass. With its positive inotropic and vasodilator activities, milrinone may have antiinflammatory effects.

Aged↗

Auxiliary total artificial heart: A compact electromechanical artificial heart working simultaneously with the natural heart.

Leading international institutions are designing and developing various types of ventricular assist devices (VAD) and total artificial hearts (TAH). Some of the commercially available pulsatile VADs are not readily implantable into the thoracic cavity of smaller size patients because of size limitation. The majority of the TAH dimensions requires the removal of the patients' native heart. A miniaturized artificial heart, the auxiliary total artificial heart (ATAH), is being developed in these authors' laboratories. This device is an electromechanically driven ATAH using a brushless direct current (DC) motor fixed in a center metallic piece. This pusher plate-type ATAH control is based on Frank-Starling's law. The beating frequency is regulated through the change of the left preload, assisting the native heart in obtaining adequate blood flow. With the miniaturization of this pump, the average sized patient can have the surgical implantation procedure in the right thoracic cavity without removing the native heart. The left and right stroke volumes are 35 and 32 ml, respectively. In vitro tests were conducted, and the performance curves demonstrate that the ATAH produces 5 L/min of cardiac output at 180 bpm (10 mmHg of left inlet mean pressure and 100 mm Hg of left outlet mean pressure). Taking into account that this ATAH is working along with the native heart, this output is more than satisfactory for such a device.

Blood Pressure↗

The DeBakey ventricular assist device: current status in 1997.

In 1993, the development began of a small axial flow blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. Nine animals survived the 2 week perioperative period and were supported for a range of 26-93 days. The first study had low flow due to poor anatomical fit of the straight cannula. In contrast, a curved cannula used subsequently provided a good anatomical fit with sufficient flow. Mean flow of 4.4 L/min was sustained with 9,900 rpm and required power was an average of 8.8 W. No thromboembolic evidences were observed in any case, and the plasma free hemoglobin level was maintained lower than 5 mg/dl, except in the early postoperative period. Three animals were terminated because of bleeding due to anticoagulant mismanagement. Electric interference (n = 1) and drive line breakage/fault (n = 2) were observed as device-related failures. Minor modifications were made to the drive line. In conclusion, the DeBakey VAD demonstrated adequate basic performance and biocompatibility. The highly reliable mechanical components and improved electrical parts are promising for a long-term implantable cardiac prosthesis.

Animals↗

An emergency balloon occlusion system for a rotary blood pump left ventricular assist system.

A fatal outcome is expected in a left ventricular assist system (LVAS) utilizing a rotary blood pump if there is no mechanism to prevent the backflow from the aorta to the heart in the case of acute pump failure. To solve this problem, a passive mechanical clamping system at the outflow graft of a rotary blood pump was developed together with Fuji Systems, Inc., Yokohama, Japan. The system consisted of an emergency clamp port and an occlusion balloon. The balloon was fixed around the outlet graft of the LVAS. In an in vitro study, a fail-safe clamping operation with 2 ml saline injection under 7 L/min flow against 140 mm Hg pressure reduced the flow to 0.5 L/min while the pressure in the system increased to 190 mm Hg. The systems were also applied to 2 in vivo LVAD studies. When the pumps were stopped, there were approximately 3.0 L/min regurgitant flows. The balloon occluder prevented this regurgitant flow effectively against a 100/80 mm Hg arterial pressure. In conclusion, this emergency balloon occlusion system is relatively easy to operate and will work efficiently in all possible clinically encountered malfunctions of the rotary blood pump LVAS.

Animals↗

Recovery from lymphocytopenia following extracorporeal circulation: simple indicator to assess surgical stress.

This study investigated whether the lymphocyte count is a useful indicator to assess surgical damage following extracorporeal bypass. In Study 1, to investigate the correlation between extracorporeal circulating time (ECCT) and lymphocyte counts, 40 elective CABG patients were studied retrospectively. The lymphocyte recovery ratio (LRR), which represented the actual lymphocyte count divided by the preoperative lymphocyte count, was determined preoperatively, and on postoperative day (POD) 1, POD 3, and POD 5. In Study 2, the correlation between the interleukin-8 (IL-8) level and LRR was examined prospectively in elective CABG patients (n = 20). We measured the LRR and serum IL-8 levels preoperatively and during extracorporeal circulation (ECC) at 5 min, at the end of ECC, and 1, 3, and 12 h following ECC termination. Study 1 showed that the LRR decreased until POD 1 and gradually increased thereafter. The LRR had a negative correlation with the ECCT. In Study 2, the IL-8 level demonstrated a time course opposite to that of the LRR; it increased until 3 h after ECC termination and declined thereafter. There was a significant negative correlation between the LRR on POD 3 and the IL-8 level at 3 h after ECC termination. In summary, long-term ECC induced significant and prolonged lymphocytopenia. The LRR had a negative correlation with IL-8. These results indicated that the LRR may represent the degree of surgical stress following ECC; therefore, the counting of lymphocytes can be a quite useful bedside monitor to assess surgical damage and prognosis.

Coronary Artery Bypass↗

Chronic survival of calves implanted with the DeBakey ventricular assist device.

The DeBakey ventricular assist device (VAD) is a miniaturized, electromagnetically driven axial flow pump capable of generating in excess of 10 L/min output. The VAD was evaluated in 19 calves during experiments designed to test iterative modifications in the system and to determine the safety of the DeBakey VAD for intermediate to long-term implant. Five of the animals died or were euthanized during the perioperative period (i.e., Days 1-5) due to complications associated with bleeding (n = 3), sudden cardiac arrest (n = 1), or pump occlusion due to a muscle remnant associated with coring (n = 1). The remaining 14 animals survived from 7-145 days. Ten of the 14 animals survived 30 or more days, and 2 animals survived 93 and 145 days before elective euthanasia. Pump function was evaluated in the 14 calves that survived beyond the perioperative period. Pump output at implantation averaged 3 L/min while output at 100 days (n = 2) averaged 4.22 L/min. The electrical current did not change across time during the study, indicating normal operation of the bearings. Pumps consumed less than 10.5 W of power for all support durations. Hemolysis did not occur; the average daily plasma free hemoglobin varied from 2.0 to 8.0 mg/dl. Evaluation of serum biochemical data showed that implantation of the DeBakey VAD in calves with normal hearts did not impair end organ function; BUN, creatinine, and total bilirubin varied minimally within the normal range. The white blood cell count of implanted animals remained within the normal range throughout the study.

Animals↗

Surgical treatment of a coronary artery fistula with concomitant saccular coronary artery aneurysm: a case report.

An extremely rare case of a coronary artery fistula with a concomitant saccular aneurysm is presented. A 65-year-old woman, who had a history of chest bruising 5 years earlier, suffered from chest pain, which was diagnosed as being due to left coronary artery-pulmonary artery fistulae concomitant with a giant saccular coronary artery aneurysm. Suture closure of the afferent coronary artery to the aneurysm, aneurysmorrhaphy, and transpulmonary closure of coronary artery-pulmonary artery fistulae were performed. The postoperative course was uneventful and the patient was well at 3 months after the operation. Because the risk of surgery appears to be less than the potential development of fatal complications, it is recommended for the treatment of coronary artery fistula with a concomitant saccular aneurysm.

Aged↗

Aortic valve replacement for aortic regurgitation caused by aortitis.

Between January 1984 and December 1998, 19 patients (16 with Takayasu's arteritis, 3 with non-Takayasu's aortitis) underwent surgical treatment for aortic regurgitation resulting from the aortitis. Of the 19 patients, 14 had aortic valve replacement (AVR) and 5 had aortic root replacement. One patient (5.3%) died of graft infection during the hospital stay. During the follow-up period, 1 (5.6%) of the 18 postoperative patients died of paravalvular leakage due to valve detachment, which also required redo-operations in 2 patients with non-Takayasu's aortitis. Both patients were operated on during the active phase of the inflammation without perioperative steroid therapy. Although transmural pledgeted sutures were used for replacement of the detached prosthetic valve in 1 of these 2 patients, disruption of the aortic wall resulted in recurrence of valve detachment. In the other patient, aortic root replacement was successfully performed with the Cabrol technique in the second operation. Perioperaitve steroid therapy plays an important role in preventing complications after AVR when the valve replacement is carried out during the active phase of the inflammation, and for patients with non-Takayasu's aortitis, aortic root replacement should be considered to reduce the tension on the suture line and the native aortic valve annulus.

Adult↗

[Influence of milrinone on internal mammary artery grafts].

To evaluate the effects of milrinone on blood flow in the left internal mammary artery (LIMA) grafts and hemodynamic variables, we conducted a prospective randomized study. Twenty-four patients undergoing coronary artery bypass grafting were randomized to receive milrinone treatment (Milrinone; n = 12) or no milrinone treatment (Control; n = 12). Milrinone was given after induction of anesthesia at a speed of 0.5 microgram/kg/min for 24 hours. After start of cardiopulmonary bypass (CPB), CPB perfusion flow was adjusted to 2.4 l/m2 and LIMA blood flow was measured. Blood samples for determination of plasma cAMP levels were collected and hemodynamic measurements were also assessed perioperatively. LIMA blood flow was significantly greater in Milrinone than that in Control (40 +/- 4 vs 29 +/- 4 ml/min/m2, p < 0.05). Plasma levels of cAMP were significantly (p < 0.05) greater in Milrinone than those in Control at tha start of CPB (18 +/- 1 vs 13 +/- 1 pmol/ml) and at the end of CPB (24 +/- 2 vs 17 +/- 2 pmol/ml). Systemic vascular resistance was significantly (p < 0.05) lower and cardiac index was significantly (p < 0.05) greater in Milrinone than those in Control postoperatively. With its positive inotropic and systemic vasodilator activities, milrinone may have direct vasodilator effect on LIMA.

Aged↗

Initial experience with the Nikkiso centrifugal pump during thoracoabdominal aortic aneurysm repair.

PURPOSE: Several centers use atriodistal bypass (ADB) as a protective adjunct against distal ischemia during extensive thoracoabdominal aortic aneurysm (TAAA) repair. Most current ADB circuits use indirect-drive centrifugal pumps. The purpose of this report is to describe our initial clinical experience with the Nikkiso pump, a more compact direct-drive centrifugal pump recently developed at Baylor, for ADB during TAAA repair. METHODS: The Nikkiso pump was used for ADB perfusion in 10 consecutive patients during graft repair of TAAAs (six Crawford extent I and four extent II). Two patients had aortic dissection. In the four patients who had extent II repairs, selective renal and visceral perfusion was also performed with the Nikkiso pump. RESULTS: No mechanical pump malfunctions or adverse events related to the device occurred. All 10 patients survived and were discharged from the hospital. No patient had paraplegia after surgery. Two patients had delayed lower extremity weakness after undergoing extent I repairs; both recovered and were ambulating at the time of discharge. No complications were associated with bleeding or cerebral, respiratory, renal, or hepatic function. CONCLUSIONS: Our initial experience with the Nikkiso centrifugal pump during TAAA repair demonstrated excellent pump function that provided sufficient flow for both distal aortic and selective organ perfusion. The prevention of permanent spinal cord injury and distal organ failure was successful in this group.

Aged↗

The safety system for the rotary blood pump, combination of the valve and LVAD pulsatile mode: in vitro test.

The significant amount of regurgitation produced by a stopped rotary blood pump is one of the major considerations for its use as an implantable left ventricular assist device (LVAD), especially if the pump accidentally stops. The installation of a valve is an option for the solution of this potential problem. However, this option may lead to thrombogenic problems, particularly if the valve motion is restricted. This in vitro study analyzes the valve performance and assesses the credibility of a rotary blood pump valve. A pulsatile pump was used as the natural heart and a centrifugal pump as the LVAD. The valve was positioned into the LVAD outflow. In the low speed range (<1,000 rpm in this test condition), normal valve motion was maintained. Also, the valve model provided a higher mean bypass flow than the model without a valve due to reduced regurgitation. However, the valve motion was drastically restricted when in the high speed range (>1,600 rpm in this condition). The pulsatile mode was applied to the LVAD by periodically changing the impeller speed (40 bpm); subsequently, a constant valve motion could be provided. A possibility exists that this pulsatile mode application could eliminate thrombosis formation around the valve. A conclusion was made that the combination of a valve and an LVAD in a pulsatile mode is considered to be a unique safety system for a rotary blood pump.

Blood Pressure↗