Search PubMed⌕ Search

Biomedical subjects

E Schneider

Publications and source records attributed to E Schneider.

At least 37 records · Page 2Linked to original sources

[A factorial trial of six interventions for the prevention of postoperative nausea and vomiting].

BACKGROUND: Untreated, one third of patients who undergo surgery will have postoperative nausea and vomiting. Although many trials have been conducted, the relative benefits of prophylactic antiemetic interventions given alone or in combination remain unknown. METHODS: In a randomized, controlled trial of factorial design, 5,199 patients at high risk for postoperative nausea and vomiting were randomly assigned to 1 of 64 possible combinations of 6 prophylactic interventions: 1) 4 mg of ondansetron or no ondansetron; 2) 4 mg of dexamethasone or no dexamethasone; 3) 1.25 mg of droperidol or no droperidol; 4) propofol or a volatile anesthetic; 5) nitrogen or nitrous oxide; 6) remifentanil or fentanyl. The primary aim parameter was nausea and vomiting within 24 h after surgery, which was evaluated blindly. RESULTS: Ondansetron, dexamethasone, and droperidol each reduced the risk of postoperative nausea and vomiting by about 26%, propofol reduced the risk by 19%, and nitrogen by 12%. The risk reduction with both of these agents (i.e., total intravenous anesthesia) was thus similar to that observed with each of the antiemetics alone. All the interventions acted independently of each other and independently of the patients' baseline risk. Consequently, the relative risks associated with the combined interventions could be estimated by multiplying the relative risks associated with each intervention. However, absolute risk reduction was a critical function of patients' baseline risk. CONCLUSIONS: Because antiemetic interventions are similarly effective and act independently, the safest or least expensive should be used first. Prophylaxis is rarely warranted in low-risk patients, moderate-risk patients may benefit from a single intervention, and multiple interventions should be reserved for high-risk patients.

Analgesics, Opioid↗

Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing.

Wear of total knee replacements is determined gravimetrically in simulator studies. A mix of bovine serum, distilled water, and additives is intended to replicate the lubrication conditions in vivo. Weight gain due to fluid absorption during testing is corrected using a load soak station. In this study, three sets of ultrahigh molecular weight polyethylene tibial plateau were tested against highly polished titanium condyles. Test 1 was performed in two different institutions on the same simulator according to the standard ISO 14243-1, using two testing lubricants. Test 2 and test 3 repeated both previous test sections. The wear and load soak rates changed significantly with the lubricant. The wear rate decreased from 16.9 to 7.9 mg weight loss per million cycles when switching from fluid A to fluid B. The weight gain of the load soak specimen submersed in fluid A was 6.1 mg after 5 x 10(6) cycles, compared with 31.6 mg for the implant in fluid B after the same time period. Both lubricants were mixed in accordance with ISO 14243 (Implants for surgery - wear of total knee-joint prostheses), suggesting that calf serum should be diluted to 25 +/- 2 per cent with deionized water and a protein mass concentration of not less than 17 g/l. The main differences were the type and amount of additives that chemically stabilize the lubricant throughout the test. The results suggest that wear rates can only be compared if exactly the same testing conditions are applied. An agreement on detailed lubricant specifications is desirable.

Body Fluids↗

Aspects of internal fixation of fractures in porotic bone. Principles, technologies and procedures using locked plate screws.

Fractures of the bones of elderly people occur more often and have a more important effect because of a generally diminished ability to coordinate stance and walking. These fractures occur at a lower level of load because of lack of strength of the porotic bone. Prompt recovery of skeletal support function is essential to avoid respiratory and circulatory complications in the elderly. To prevent elderly people from the risks of being bedridden, demanding internal fixation of fractures is required. The weak porotic bone and the high level of uncontrolled loading after internal fixation pose complex problems. A combination of several technical elements of design, application and aftercare in internal fixation are proposed. Internal fixators with locked screws improve the biology and the mechanics of internal fixation. When such fixators are used as elevated splints they may stimulate early callus formation because of their flexibility, the limit of flexibility being set by the demands of resistance and function of the limb. Our own studies of triangulation of locked screws have demonstrated their beneficial effects and unexpected limitations.

Aged↗

Performance of a composite flow moulded carbon fibre reinforced osteosynthesis plate.

Non-metallic implants have the advantage over metallic implants of reduction in artefact with CT and MR diagnostic imaging. In-vivo performance of a carbon fibre reinforced polyetheretherketone radiolucent plate (Snake Plate [SP]) with high stiffness, and fixed angle converging screws was compared with a seven-hole titanium Locking Compression Plate (LCP), using a sheep tibial osteotomy model (gap 0.6 mm). The sheep were divided into two groups, and the osteotomies were stabilized with a SP (n = 6) or a LCP (n = 6). The callus dimensions were measured radiographically at zero, two, four, six and eight weeks. The animals were euthanatized after eight weeks. Osteotomised and contralateral tibiae were tested in pairs torsion, to determine strength and stiffness. In the radii of six separate sheep, initial vascular disturbance after plate implantation was evaluated. All of the sheep of the SP and LCP groups showed maximal callus areas at six weeks. The differences between the groups, in callus dimension, were not significant at any time point. The median values for relative reduction (100 x [operated contralateral] / contralateral) in strength of osteotomized tibiae was -13.93% for the SP group and -7.49% for the LCP group (p = 0.5228), and for stiffness it was -24.44% for the SP group and -27.08% for the LCP group (p = 0.6481). Neither the SP nor LCP caused any notable disturbance in periosteal circulation. The SP appears to represent a valuable alternative to metallic implants for shaft fracture repair. The main advantages of the SP are radiolucency, high deformation resistance, internal fixator concept and converging screw configuration for optimal loading conditions in the bone-implant construct.

Animals↗

New implant designs for fracture fixation in osteoporotic bone.

Screws are one of the limiting factors for fixation of implants, particularly in poor bone quality. A class of new implants with an implant-bone-interface optimized regarding load transition by increasing the peripheral area might improve the anchorage of implants in osteoporotic bone. However, the shape of these implants requires new technologies for insertion. The goal of the work presented here was to analyze the relevant parameters regarding implant geometry and to demonstrate the effect of new procedures for their insertion. The investigation was divided into three parts: 1) implant design optimisation, 2) efficiency of cortical bone ablation, and 3) implant insertion technology. Finite element analysis (FEA) was performed to investigate the influence of the number of lobes, the radius of the outer curvature and additional milling to remove any sharp changes of section around the lobe. Opening of the cortical bone with an Er:YAG laser was studied using calf cortex from 2 to 7 mm thickness. The effect of a) pulse energy and pulse duration, b) cortical thickness, c) wet or dry boundary conditions on volume and geometry of ablated bone, time required to penetrate the cortical bone and local bone tissue damage was quantified. Pneumatic and ultrasound based insertion were compared in the third experiment. The cortical bone was prepared in the following ways: a) no opening, b) predrilling of three holes (1 mm diameter each) and c) exact pre-cutting of the whole contour. Increasing the radius of the outer curvature from 2 to 5 mm reduces the peak stresses during loading in all planes in the implant as well as in the adjacent cortical bone by about 30-40%. An increase in the number of lobes from two to three decreases the mean peak stress by about 46% (alpha < 0.001) and the range between the minimal and maximal peak stresses for different loading directions by about 83%. Penetration of cortical bone with an Er:YAG laser was possible up to a cortical thickness of 6 mm with fewer than 100 pulses. The ablation rate per pulse increased more with increasing duration than with increasing energy. Signs of bone damage such as melting were only visible when high pulse energies and durations were used. Insertion of the prototype was possible with all devices, but only when the whole contour was cut out of the cortical bone. However, the use of the ultrasound vibrator led to heating up of the tissue fluid and subsequently to water evaporation and tissue damage. Insertion of the prototype was possible with both pneumatic vibrators, but only when the whole contour was cut out of the cortical bone. New implant designs may lead to reduced stress peaks in the surrounding bone and might be inserted with the help of new insertion technologies, namely laser cutting of cortical bone and pneumatic vibration. Further studies are required to optimize these technologies prior to clinical use.

Animals↗

Mechanical behavior of screws in normal and osteoporotic bone.

Fracture fixation in severe osteoporotic bone by means of implants that rely on screw anchorage is still a clinical problem. So far, a sufficiently accurate prediction of the holding capacity of screws as a function of local bone morphology has not been obtained. In this study the ultimate pullout loads of screws in the epi-, meta-, and diaphyseal regions of human tibiae were correlated to the cortical thicknesses and cancellous bone mineral densities at the screw axes determined from QCT densitometric data. Stepwise multiple linear regression showed that in regions with cortical thicknesses below 1.5 mm, cancellous density determined the ultimate pullout load (R2 = 0.85, p < 0.001), while in regions with cortices above 1.5 mm, cortical thickness alone significantly influenced the holding capacity of a screw (R2 = 0.90, p < 0.001). The findings of this study provide a basis for a bone morphology-related pre-operative estimation of the holding capacity of screws, which could help to improve their proper application in osteoporotic bone.

Aged↗

Diagnosis of vestibular imbalance in the blink of an eye.

BACKGROUND: In a recent study, the authors found that blinks in healthy volunteers always triggered ocular torsion quick phases during dynamic roll movements of the head. On the basis of this observation, they hypothesized that blinks in patients with a vestibular tone imbalance would also trigger torsional quick phases. METHODS: Using video-oculography with a fixation target, the authors recorded the ocular torsion position of the left eye of 37 participants while they made voluntary blinks once every 6 to 10 seconds. The participants were recruited from four groups: two age groups of healthy volunteers with a mean +/- SD age of 32 +/- 4 (n = 9) and 65 +/- 11 y (n = 9); patients with a unilateral vestibular disorder in an acute state (n = 12, 53 +/- 17 y); and those in a persisting state in which spontaneous nystagmus had already faded (n = 9, 65 +/- 13 y). RESULTS: In the control groups of healthy volunteers, blinks triggered no or only small quick phases on the order of 0.1 deg. In both patient groups blinks always triggered quick phases with significantly higher amplitudes of 1.85 +/- 1.02 deg and were followed by exponentially decaying slow-phases with time constants on the order of 1 to 2 seconds. Patients in the persisting state clearly differed from patients in the acute state in that their torsional spontaneous nystagmus had already vanished due to vestibular compensation. But surprisingly, these two groups did not show a large difference in terms of the effect of blinks on ocular torsion. The authors always observed torsional quick phases with the upper pole of the eye beating away from the side of the lesion. CONCLUSIONS: Blinks are able to trigger torsional quick phases in patients with both acute and persisting vestibular disorders. The side of the impairment can be determined from the direction in which the eye is rotated after a blink. Thus, ocular torsion recordings during blinks can be used as a simple clinical test for a vestibular tone imbalance, particularly during a persisting failure in which spontaneous nystagmus has resolved and can therefore no longer be used for diagnosis.

Adult↗

Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws.

Internal fixators are a new class of implants designed to preserve the periosteal blood supply of the bone. In contrast to conventional plate fixation in which the screws have spherical heads and are loaded mainly by axial pullout forces, screws in internal fixators are "locked" within the plate and therefore subjected to axial as well as bending loads. In this study the ultimate loads of screws of a commercially available internal fixator system were tested in a pullout (n = 72) and cantilever bending mode (n = 72) in metaphyseal and diaphyseal regions of four pairs of human tibiae with different bone qualities. Cortical thickness and cancellous bone density were determined at the screw insertion sites. Stepwise multiple linear regression revealed that cortical thickness and cancellous density can explain 93% and 98% of the variance of the ultimate load of the screws in an axial pullout and cantilever bending mode. Screws in internal fixators are better suited to transmit shear forces and thereby make better use of the strength potential of bone than screws used in conventional plate fixation: this is especially advantageous when bone strength is reduced, e.g. due to osteoporosis.

Aged↗

Pain perception in patients undergoing bone marrow puncture--a pilot study.

The objective of this study was to establish the relationship between the perception of pain, anxiety, and depressive tendency in performance of bone marrow puncture. 93 consecutive patients (62% men, 38% women) from a hematological oncology outpatient department ages 20 to 85 years (M age = 53.7, SD = 15.1) were questioned. On average, the patients had undergone 2.5 (+/- 2.6) punctures. The underlying disease was leukemia in 49%, malignant lymphoma in 41%, another malignant disease in 2%, and there was a benign condition in 8%. Depression and general anxiety were measured using the Hospital Depression and Anxiety Scale (HADS-D). Fear of puncture and perception of pain were registered with visual analog scales. Patients with increased scores of anxiety or depressive tendency on the HADS-D suffered significantly more severely from fear of puncture and pain than patients with normal scores. However, the puncture-related fear in the group as a whole correlated markedly more closely with the intensity and tolerability of pain than did general fear and depressive tendency. This finding must be considered when planning psychological interventions in this group of patients.

Adult↗

Resorption patterns of calcium-phosphate cements in bone.

Two calcium phosphate cements, one monophasic and the other biphasic, have been used as bone void filler in a sheep model. The cements were injected into a slot defect in the proximal tibia and into a cylindrical defect in the distal femur. In this study, we focused on the resorption pattern of the two cement formulations and the subsequent biologic reaction. Bone remodeling occurred synchronously with the resorption of the implant material in a creeping substitution process. Cracks and pores in the monophasic cement were filled with osseous tissues. The biphasic cement showed faster resorption of the matrix. The more slowly resorbing granules were surrounded by newly grown bone, thus providing an inverse scaffold for cancellous bone regeneration. In highly loaded areas, the long-term support function of the fixation appears to be critical. Because cortical bridging of the defects was seen in only one case, it can be concluded that calcium-phosphate cements are preferentially suitable as cancellous bone substitute materials.

Animals↗

[Radiation dosage in orthopedics -- a comparison of computer-assisted procedures].

Since the 1990s, computer-assisted methods have been well-established in the field of orthopedics and traumatology. In addition to the proven improvement in the field of surgical precisioncompared with conventional techniques, the decrease in the amount of emitted ionizing radiation inside of the operating room was cited to constitute an additional major advantage of computer-based navigation. The goal of this study was to quantify X-ray dose values exposed during both conventional methods and computer-assisted procedures, the latter being performed using a C-arm device SIREMOBIL Iso-C3D (Siemens Medical Solutions). The clinical measurements were supplemented by laboratory experiments using a pinpoint ionization chamber placed inside a standard lucite phantom. The clinical part of the study investigated the application of new, i.e. computer assisted, techniques in comparison with conventional procedures on in total 42 patients experiencing surgery either on their lower extremities (n = 14) or on the spine (n = 28). The techniques applied were: (1) conventional surgical procedure, (2) CT-based navigation, (3) C-arm navigation, and (4) Iso-C3D-navigation. The main focus of the clinical evaluation was the determination of radiation dose values by means of thermoluminescence dose meters, accompanied by the registration of the operation times of the X-ray tube during a surgical intervention. The conclusions from the clinical studies are in agreement with the results from the laboratory measurements. Computer-assisted techniques led to a significant reduction in X-ray dose exposure and drastically shortened irradiation times. The most pronounced decrease in the emission of ionizing radiation was achieved in case of the Iso-C3D-navigation, which has only recently been introduced into clinical practice, i.e. during runtime of this study.

Humans↗

Biomechanical evaluation of healing in a non-critical defect in a large animal model of osteoporosis.

Current methods for fracture treatment in osteoporosis are not always sufficient. To develop new fixation strategies (both mechanical and biological) requires pre-clinical testing utilizing appropriate models. The aim of this study was to apply a recently developed sheep model of osteoporosis to the study of healing in a non-critical long bone defect. A standardized transverse mid-shaft tibial osteotomy (with a fracture gap of 3 mm) was performed in seven osteoporotic and seven normal sheep and stabilized with a special external fixator for 8 weeks. The fixator was used for weekly in vivo bending stiffness measurements. Ex vivo bending stiffness and torsional stiffness of the callus zone were also determined. Callus area, callus density, and osteoporosis status were determined at 0, 4, and 8 weeks using peripheral quantitative computed tomography. The increase of in vivo bending stiffness of the callus was delayed approximately 2 weeks in osteoporotic animals. A significant difference (33%) in torsional stiffness was found between the osteotomized and contralateral intact tibia in osteoporotic animals, but no significant difference occurred in normal sheep (2%). In osteoporotic animals, ex vivo bending stiffness was reduced 21% (p=0.05). Bending stiffness was correlated with callus density (r=0.76, r=0.53); torsional stiffness was correlated with callus area (r=0.60) and to a lesser extent with callus density (r=0.53). This study demonstrated a delay of fracture healing in osteoporotic sheep tibiae with respect to callus formation, mineralization, and mechanical properties.

Animals↗

An experimental two degrees-of-freedom actuated external fixator for in vivo investigation of fracture healing.

A novel two degrees-of-freedom external fixator that can accurately control interfragmentary mechanical conditions over an ovine tibial osteotomy is presented. The device can apply either axial or torsional motion, to investigate mechano-transduction mechanisms in fracture healing. The device was bench-tested over a range of gap stiffnesses, for its ability to apply pure axial or torsional motions, control interfragmentary strain magnitudes and to measure stiffness over the gap. The experiments reveal very little cross-coupling between axial and torsional displacements, although some transverse displacement occurs for both degrees-of-freedom. The mean interfragmentary strain can also be accurately controlled, but with some variation over the gap (due to coupled transverse displacement error). Interfragmentary stiffness measurements are accurate up to gap stiffnesses corresponding to bony bridging. This characterisation study has shown that the system is adequate to control and measure the mechanical conditions in a fracture healing experiment.

Animals↗

Tuberculosis trends in the United States, 1992-2001.

At the time of the last world congress on tuberculosis (TB) in 1992, the United States (US) was experiencing an unprecedented resurgence of TB. Since the mid-1950s, TB incidence had been steadily decreasing, until 1984 when this longstanding trend was reversed. The annual national total of TB cases continued to increase and peaked in 1992 with 26,673 TB cases reported (10.5 TB cases per 100,000 population). A prompt and formidable response from local, state, and federal governments helped curb the resurgence. From 1992 to 2001, total TB incidence decreased by 40% to an all-time low of 15,989 TB cases reported in 2001. The decrease in TB cases from 2000 to 2001, however, was the smallest (2.4%) since the resurgence a decade ago. This report will briefly review the trends and factors associated with the TB resurgence in the late 1980s and early 1990s, and provide a detailed description of specific TB trends in the US between 1992 and 2001.

AIDS-Related Opportunistic Infections↗

[Are the terms "biology" and "osteosynthesis" contradictory?].

Biology and Osteosynthesis may, at first glance, appear to be contradictory. The disadvantages of the surgical procedure are offset by improved recovery of blood supply across a fracture zone and by stimulation of callus formation due to (controlled and slight) instability (elastically flexible fixation). Biological internal fixation is a principle in its own right; its technique is to some extent incompatible with conventional compression fixation. Locked screws provide better anchorage of the implant in both biological and compression internal fixation techniques. This generally offers improved potential in the treating fractures in osteoporotic bone. Because locked screws offer improved anchorage, the use of unicortical screws is made possible with the effect that the medullary circulation is damaged less. Locked unicortical screws, especially if they are self-drilling and self-cutting, offer important surgical advantages in minimally invasive percutaneous osteosynthesis (MIPO) whereas bicortical screws are required for epi- and metaphyseal anchorage.

Adolescent↗

Investigation of the pharmaceutical and pharmacological equivalence of different Hawthorn extracts.

Seven Hawthorn extracts were tested in isolated guinea pig aorta rings. The effect on noradrenaline- (10 microM) induced contraction was investigated. The extracts were prepared using ethanol (40 to 70% v/v), methanol (40 to 70% v/v), and water as the extraction solvents. The aqueous-alcoholic extracts displayed similar spectra of constituents. They were characterised by similar procyanidin, flavonoid, total vitexin and total phenols content and by similar TLC fingerprint chromatograms. The aqueous extract, however, showed a different fingerprint and a noticeably lower concentration of procyanidins, flavonoids and total phenols but a similar total vitexin content. All 7 extracts had a relaxant effect on the aorta precontracted by noradrenaline and led to relaxations to 44 until 29% of the initial values. The EC50 values of the aqueous-alcoholic extracts varied between 4.16 and 9.8 mg/l. The aqueous extract produced a similarly strong maximal relaxation as the other extracts, but the EC50, at 22.39 mg/l, was markedly higher. The results show that Hawthorn extracts with comparable quality profiles were obtained by using aqueous-alcoholic extraction solvents (40 to 70% ethanol or methanol). The extracts exerted comparable pharmacological effects. When using water as the extraction solvent, both, the spectrum of constituents and the pharmacological effect, deviated remarkably. It is thus possible to obtain bioequivalent extracts with comparable effect profiles by using 40 to 70% ethanol or methanol as the extraction solvent.

Animals↗

Impact of bone density on distal radius fracture patterns and comparison between five different fracture classifications.

OBJECTIVE: To investigate the impact of bone mineral density (BMD) and bone geometry on failure loads and fracture patterns of the distal radius and to compare 5 different fracture classifications. DESIGN: Biomechanical and radiologic in vitro study. SETTING: Research laboratory. MAIN OUTCOME MEASUREMENTS: A total of 118 intact human forearms from elderly donors were examined by means of conventional radiography and peripheral quantitative computed tomography (PQCT) to determine BMD and geometry. The forearms were subjected to a standardized biomechanical test simulating a fall on the outstretched hand. The distal radius fractures were classified from x-rays using the AO ( 33), Cooney ( 9), Fernandez ( 15), Frykman ( 17), and Melone ( 31) classifications. The grading was repeated after preparation and direct visual inspection of the fracture site and was correlated with radiographic results. Fracture patterns also were correlated with BMD and geometry. RESULTS: Correlations between bone properties and fracture patterns (r = 0.09-0.70) suggested an increase in the severity of fractures with decreasing bone quality. The highest correlation between failure load and bone properties was found for the cortical area (r = 0.70) and trabecular density (r = 0.60). Good correlations between radiographic and direct visual classification were obtained for the Cooney ( 9) (r = 0.70), the AO ( 33) (r = 0.68), and the Fernandez ( 15) (r = 0.65) classifications. Smaller values were found for the Frykman ( 17) (r = 0.44) and the Melone ( 31) (r = 0.27) classifications. CONCLUSIONS: With increasing osteopenia, the load to failure decreases, and the severity of fractures increases. Fracture patterns in this patient population can be adequately graded with the AO ( 33) and Cooney ( 9) classifications. The severity of distal radius fractures tends to be underestimated by conventional x-ray examination, which needs to be taken into account when a fracture treatment plan is selected.

Aged↗

Anterior canal failure: ocular torsion without perceptual tilt due to preserved otolith function.

A patient with anterior semicircular canal dehiscence syndrome underwent surgical patching that caused an isolated dysfunction of the left anterior semicircular canal postoperatively. He exhibited significant ocular torsion toward the side of the affected labyrinth (17 degrees excyclotropia of the ipsilateral eye), but no displacement of the subjective visual vertical. This dissociation suggests that an isolated ocular torsion may occur after an anterior semicircular canal lesion. A combined ocular torsion and subjective visual vertical tilt, which is usually seen with vestibular lesions, requires an associated otolith dysfunction.

Eye Diseases↗