Search PubMed⌕ Search

Biomedical subjects

E Sbarouni

Publications and source records attributed to E Sbarouni.

29 records · Page 2Linked to original sources

Serial follow-up after optimized ultrasound-guided deployment of Palmaz-Schatz stents. In-stent neointimal proliferation without significant reference segment response.

BACKGROUND: The effects of ultrasound-guided high-pressure stenting on late stent and reference segment dimensions are unknown. In this study, we report about angiographic and ultrasound measurements to assess the amount and distribution of neointimal ingrowth within the stent and the changes of plaque burden and dimensions within the reference segments. METHODS AND RESULTS: Sixty-eight consecutive patients with 72 lesions received single or multiple Palmaz-Schatz coronary stents with a standardized protocol for stent optimization under ultrasound guidance. The residual angiographic diameter stenosis was 3 +/- 12% (reference diameter, 3.16 +/- 0.61 mm). At follow-up 4.8 +/- 2.5 months later, angiography revealed a diameter stenosis of 27 +/- 21% with a restenosis rate of 15.3% (confidence interval: 7.8% to 25.6%). Lumen renarrowing within the stent was exclusively due to neointimal ingrowth; no stent compression was observed. The neointima covered 20 +/- 20% of the stent area and was more pronounced in the midportion of the stent. Volumetric assessment performed in 26 patients resulted in 13 +/- 14% or 65 +/- 28% of the stent volume occupied by neointimal ingrowth in patients without or with restenosis, respectively. Vessel remodeling had an impact on lumen dimensions only at reference sites but not within the stent. Plaque burden of 46 +/- 11% and 48 +/- 11% at the proximal and distal reference sites, respectively, did not show a relevant progression during the follow-up. CONCLUSIONS: Serial ultrasound analyses did not show any evidence of stent compression or relevant vessel remodeling. Restenosis was solely due to neointimal ingrowth. Despite a considerable plaque burden within the reference segments, there was no relevant progression of the disease adjacent to the stent.

Adult↗

Estrogen replacement therapy and exercise performance in postmenopausal women with coronary artery disease.

We treated 10 postmenopausal women with stable angina, positive exercise test, and documented coronary artery disease with oral conjugated equine estrogen (0.625 mg/day of Premarin) or placebo for 4 weeks, in random order, with crossover after a 4-week washout period. Exercise tests, performed after each treatment period while the patients were taking their usual antianginal drugs showed no differences; thus, short-term estrogen does not improve exercise-induced ischemia compared with placebo.

Aged↗

Coronary collateral blood-flow velocity improves with repeated coronary occlusions during angioplasty in patients with coronary artery disease and systemic hypertension.

BACKGROUND: Cardiac hypertrophy is associated with numerous alterations in the coronary circulation. OBJECTIVE: To test the hypothesis that, during angioplasty, the coronary collateral blood flow during repetitive coronary occlusions increases more in hypertensives than it does in normotensives. METHODS: We studied 34 patients (22 normotensives and 12 hypertensives) with stable angina and single-vessel disease undergoing coronary angioplasty during two similar balloon inflations. Each balloon inflation was maintained for 120 s. The coronary blood flow velocity was estimated using the Doppler-flow guide wire, which was positioned distally to the lesion. Flow velocities were recorded before balloon deflation. RESULTS: The average peak velocity increased by 29.0 +/- 14.7 mm/s in the hypertensives and decreased by 9.4 +/- 4.9 mm/s in the normotensives (P < 0.01) during the second balloon inflation, whereas the velocity-time integral increased by 33.1 +/- 19.2 mm and decreased by 14.3 +/- 11.3 mm (P < 0.05), respectively. The ST-segment elevation decreased by 1.13 +/- 1.27 and by 0.17 +/- 0.16 mV, respectively (P = 0.01). The increase in the average peak velocity which occurred during the second balloon inflation was related to the left ventricular mass (r = 0.47, P = 0.004). CONCLUSION: These results indicate that the coronary collateral blood flow velocity improves with repetitive coronary occlusions during angioplasty in patients with systemic hypertension and that this increase is correlated to the left ventricular mass.

Adaptation, Physiological↗

Symptoms of hypertrophic cardiomyopathy, with special emphasis on syncope and postprandial exacerbation of symptoms.

We undertook a prospective study of the symptoms of hypertrophic cardiomyopathy with the aim of profiling symptomatic morbidity in detail, determining the prevalence of anxiety and depression, and describing the prevalence and associations of syncope and postprandial symptom exacerbation. A questionnaire was administered to consecutive outpatients; 70 with hypertrophic cardiomyopathy, 43 with coronary artery disease, 32 with idiopathic dilated cardiomyopathy, and to 40 normal subjects. Hypertrophic cardiomyopathy patients underwent exercise testing, echocardiography, and Holter monitoring. Hypertrophic cardiomyopathy patients had a high frequency of cardiac symptoms and, on average, had a level of symptomatic morbidity equivalent to that of chronic stable angina and dilated cardiomyopathy. There was no evidence for an excess of anxiety (14%) or depression (6%) in patients with hypertrophic cardiomyopathy. Syncope and presyncope, especially provoked by exertion or posture change, were characteristic and common symptoms in hypertrophic cardiomyopathy. A history of syncope was associated with an abnormal blood pressure response to exercise in over 50% of cases that may be the mechanism of syncope in some. Postprandial exacerbation of symptoms occurred in over one-third of hypertrophic cardiomyopathy patients, half of coronary disease patients, and infrequently in dilated cardiomyopathy. Hypertrophic cardiomyopathy patients with postprandial symptoms had a greater frequency of angina, were more symptomatic, and had a reduced exercise capacity, suggesting that postprandial symptoms are a marker for more severe disease.

Adolescent↗

Myocardial contrast echocardiography for assessment of papaverine vasodilator response in patients with angiographically normal coronary arteries and in patients after orthotopic heart transplantation.

Myocardial contrast echocardiography has the potential for assessing changes in regional myocardial perfusion. We used this method to compare papaverine vasodilator response in 10 patients after orthotopic heart transplantation without acute rejection of left ventricular hypertrophy (HTX) and in 15 patients with angiographically normal coronary arteries (control group). Injections of 2 ml of sonicated iopromid (9 paired injections in HTX and 24 paired injections in the control group) were performed before and after intracoronary application of papaverine (8 or 10 mg) into the left or right coronary artery. From regional time-intensity curves, alpha (variable of curve width), area under the curve (area), peak contrast intensity (Imax) and contrast decay half-time (T1/2) were derived by from a gamma variate function. T1/2 increased from 4.2 +/- 1.2 to 7.2 +/- 4.0 s (p < 0.01) after papaverine in HTX compared to a change from 4.8 +/- 1.0 to 6.0 +/- 1.7 s (p < 0.001) in normal subjects. Alpha decreased in HTX from 0.44 +/- 0.15 to 0.27 +/- 0.10 s-1 (p < 0.01) after intracoronary papaverine injection. In the control group alpha was 0.37 +/- 0.08 s-1 at rest compared to 0.30 +/- 0.08 s-1 at hyperemic conditions (p < 0.002). Area increased in HTX from 444 +/- 261 to 910 +/- 732 U.s (p < 0.01) and in normal subjects from 352 +/- 171 to 585 +/- 262 U.s (p < 0.001). Hyperemic to baseline flow ratios for area varied from 0.9 to 3.8 (mean 2.17 +/- 1.11) in HTX compared to 1.76 +/- 0.52 (1.03 to 2.71) in normal subjects.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Microcoil embolization of large intercostal branches of internal mammary artery grafts.

Coronary artery steal via a large unligated intercoastal side-branch of the internal mammary artery graft has been previously described in two case reports. We report a series of 7 patients with post-operative angina in whom microcoil embolization of such branch was performed. In 5 patients in whom complete occlusion of the branch was achieved, anginal symptoms were relieved; in contrast the 2 patients with persistent flow through the intercostal branch remained symptomatic despite all their grafts being widely patent. We conclude that large unligated intercostal branches of the IMA graft may be related with post-operative angina and their embolization is a simple, safe, and effective procedure.

Adult↗

Relationship between hemostatic abnormalities and neuroendocrine activity in heart failure.

Thromboembolism is an important complication of heart failure. To test the hypothesis that heart failure may be associated with hemostatic dysfunction, we studied hemostatic function in 21 patients with stable chronic heart failure and related these measures to the severity of heart failure as assessed by clinical evaluation, neuroendocrine activation, radionuclide ventriculography, and cardiopulmonary exercise testing. Plasma and blood viscosity were elevated; all patients showed evidence of platelet activation, and many had elevated plasma concentrations of fibrinopeptide A, D-dimer, and von Willebrand factor. The plasma concentrations of these variables were poorly interrelated and related poorly to the severity of heart failure. Plasma concentrations of angiotensin II and endothelin were correlated, and the latter was also correlated with the plasma concentration of von Willebrand factor. Patients with chronic heart failure have hemostatic abnormalities that may predispose them to thromboembolic events and may be in part due to neuroendocrine activation.

Adult↗

Outcome of pregnancy in women with valve prostheses.

OBJECTIVE: To study the outcome of pregnancy in women with artificial heart valves treated in major European centres, and to compare the safety and efficacy of different anticoagulant regimens and of mechanical and bioprosthetic valves. DESIGN: Retrospective study. METHOD: The information was obtained by questionnaire sent to all major cardiac centres in Europe sending one cardiologist from each centre a covering letter suggesting that the questionnaire be handed on where appropriate to the most relevant colleague. RESULTS: 214 pregnancies were reported in 182 women; 151 pregnancies in 133 women with mechanical valves, and 63 pregnancies in 45 women with bioprostheses. Most women were in New York Heart Association class I or II and in sinus rhythm. 150 women with mechanical valves and 11 (17%) with bioprostheses received anticoagulants during pregnancy. One patient with an aortic valve prosthesis refused to take anticoagulants. Including the spontaneous abortions reported as well as the therapeutic abortions 83% of the pregnancies in women with bioprostheses and 73% in those with mechanical valves resulted in a healthy baby, full term or premature, who did well (NS). The incidence of stillbirths (3% and 6%) and of reported spontaneous abortions are excluded (because they are unlikely to have been fully reported), the success rate was 91% for women with bioprosthetic valves and 84% for women with mechanical valves (NS). 114 (53%) of the women had taken warfarin for some part of the pregnancy (46 (40%) of these during the first trimester) but there were no embryopathies. There were 13 valve thromboses (four fatal), eight embolic events (two fatal), and seven bleeds in women with mechanical valves. Most of these complications occurred with heparin but fatal aortic valve thrombosis occurred in the one woman who refused anticoagulant treatment out of the 151 women with mechanical valves. There were no maternal deaths in the bioprosthesis group but in 17/49 (35%) of these valves functional deterioration led to urgent replacement during pregnancy (two) or soon after. CONCLUSIONS: The outcome of pregnancy was similar for women with mechanical valves or bioprostheses. Warfarin treatment was safe and effective and was not associated with embryopathy. Heparin treatment was associated with more thromboembolic complications and more bleeding complications. Bioprostheses deteriorate rapidly during pregnancy.

Abortion, Spontaneous↗

Autonomic function in hypertrophic cardiomyopathy.

BACKGROUND: Autonomic dysfunction has been found to be a powerful predictor of arrhythmic events and sudden death after myocardial infarction. Hypertrophic cardiomyopathy carries a risk of sudden death and this risk is increased by the occurrence of syncope. OBJECTIVES: To determine if autonomic dysfunction occurs in patients with hypertrophic cardiomyopathy and if it is associated with the occurrence of syncope. PATIENTS AND METHODS: Autonomic function was measured in 30 patients with hypertrophic cardiomyopathy, 15 with and 15 without a history of syncope, and in 28 healthy volunteers. RESULTS: Tests of parasympathetic activity showed that the mean (SD) variation in heart rate during deep breathing was reduced in patients compared with controls, 17 (9) v 22 (9) beats/min, p = 0.03, the Valsalva ratio was also reduced in patients, 1.52 (0.33) v 1.70 (0.36), p = 0.05 but the immediate heart rate response to standing, the 30:15 ratio, was similar in both groups. Tests of sympathetic activity--namely the diastolic blood pressure response to sustained handgrip and the change in systolic blood pressure on standing--did not differ between patients and controls. There was no significant difference in autonomic function between patients with and without a history of syncope. A secondary predetermined analysis showed that the degree of impairment in variation of heart rate with breathing was correlated with the severity of left ventricular hypertrophy, r = 0.39, p = 0.03. CONCLUSIONS: Patients with hypertrophic cardiomyopathy have a selective impairment of variability of heart rate with deep breathing and the Valsalva manoeuvre indicating decreased cardiac parasympathetic activity. The data suggest that the afferent limb of these reflexes is impaired and that the severity of impairment is related to the degree of left ventricular hypertrophy.

Adolescent↗

Influence of left ventricular hypertrophy and function on the occurrence of ventricular tachycardia in hypertrophic cardiomyopathy.

Sixty-nine patients with hypertrophic cardiomyopathy were studied by 2-dimensional and Doppler echocardiography and 72-hour Holter monitoring to examine the relation between the degree of left ventricular (LV) hypertrophy and dysfunction and the occurrence of ventricular tachycardia (VT). Episodes of nonsustained VT were detected in 20 patients (29%). Maximal wall thickness was not different between patients with (22 +/- 5 mm) and without (21 +/- 5 mm) VT. Total hypertrophy score, calculated as the sum of 10 segmental wall thicknesses, was also similar in both groups (157 +/- 22 and 153 +/- 32 mm, respectively; p = not significant). Furthermore, no significant differences were found between the 2 groups in LV end-diastolic dimension (41 +/- 7 vs 40 +/- 6 mm), fractional shortening (33 +/- 7 vs 34 +/- 10%) and left atrial size (40 +/- 10 vs 41 +/- 11 mm). An LV outflow tract gradient was detected in 25% of patients with and 35% without VT (p = not significant). One or more Doppler indexes of diastolic function were abnormal in 70% of patients, but no difference in any of these indexes was found between those with and without VT. In summary, the occurrence of VT in hypertrophic cardiomyopathy is not related to the degree of LV hypertrophy, outflow tract gradient or dysfunction. This finding suggests a dissociation between the arrhythmogenic substrate and echocardiographic features of the disease.

Adolescent↗

QT-interval abnormalities in hypertrophic cardiomyopathy.

To examine whether QTc and QTc dispersion across the leads of a surface electrocardiogram (ECG) are different in patients with hypertrophic cardiomyopathy (HCM) compared with normal subjects, we measured QT and calculated QTc in all 12 leads of a surface ECG in 24 patients with HCM and in 20 age- and sex-matched normal control subjects. Maximal QTc was prolonged in HCM patients (465 +/- 24 ms) compared with controls (410 +/- 20 ms) (p < 0.001). QTc dispersion defined as the difference of maximum-minimum QTc was also greater in HCM patients (71 +/- 21 ms) compared with normals (35 +/- 11 ms) (p < 0.001). A correlation was found between the degree of left ventricular hypertrophy expressed by the maximal wall thickness and maximal QTc (r = 0.48, p < 0.02). However, QTc dispersion did not correlate with maximal wall thickness. Thus, patients with HCM show a prolonged QTc (> 440 ms) and increased QTc dispersion compared with normal subjects. In addition, the degree of left ventricular hypertrophy correlates with maximal QTc. The presence of a prolonged QT with increased regional dispersion may be associated with the occurrence of serious ventricular arrhythmia and sudden death in HCM.

Adult↗