Search PubMed⌕ Search

Biomedical subjects

E S Bennett

Publications and source records attributed to E S Bennett.

At least 19 recordsLinked to original sources

Channel activation voltage alone is directly altered in an isoform-specific manner by Na(v1.4) and Na(v1.5) cytoplasmic linkers.

The isoform-specific direct role of cytoplasmic loops in the gating of two voltage-gated sodium channel isoforms, the human cardiac channel (Na(v1.5); hH1) and the human adult skeletal muscle channel (Na(v1.4); hSkM1), was investigated. Comparison of biophysical characteristics was made among hSkM1, hH1, and several hSkM1/hH1 chimeras in which the putative cytoplasmic loops that join domain I to II (loop A) and domain II to III (loop B) from one isoform replaced one or both of the analogous loops from the other isoform. For all parameters measured, hSkM1 and hH1 behavior were significantly different. Comparison of hSkM1 and hH1 biophysical characteristics with the function of their respective chimeras indicate that only the half-activation voltage ( V(a)) is directly and differently altered by the species of cytoplasmic loop such that a channel consisting of one or both hSkM1 loops activates at smaller depolarizations, while a larger depolarization is required for activation of a channel containing one or both of the analogous hH1 loops. When either cardiac channel loop A or B is attached to hSkM1, a 6-7 mV depolarizing shift in V(a) is measured, increasing to a nearly 20 mV depolarization when both cardiac-channel loops are attached. The addition of either skeletal muscle-channel loop to hH1 causes a 7 mV hyperpolarization in V(a), which increases to about 10 mV for the double loop chimera. There is no significant difference in either steady-state inactivation or in the recovery from inactivation data between hSkM1 and its chimeras and between hH1 and its chimeras. Data indicate that the cytoplasmic loops contribute directly to the magnitude of the window current, suggesting that channels containing skeletal muscle loops have three times the peak persistent channel activity compared to channels containing the cardiac loops. An electrostatic mechanism, in which surface charge differences among these loops might alter differently the voltage sensed by the gating mechanism of the channel, can not account for the observed isoform-specific effects of these loops only on channel activation voltage. In summary, although the DI-DII and DII-DIII loop structures among isoforms are not well conserved, these data indicate that only one gating parameter, V(a) is affected directly and in an isoform-specific manner by these divergent loop structures, creating loop-specific window currents and percentages of persistently active channels at physiological voltages that will likely impact the excitability of the cell.

Animals↗

Channel cytoplasmic loops alter voltage-dependent sodium channel activation in an isoform-specific manner.

1. The isoform-specific functional role of cytoplasmic structures of two voltage-gated sodium channel isoforms, the human cardiac channel (hH1) and the adult human skeletal muscle channel (hSkM1) was investigated through functional comparison of chimeras. 2. The voltage of half-activation (V(a)) for hH1 was shifted by > 20 mV in the hyperpolarised direction following internal papain treatment ('papain sensitive'), while V(a) for hSkM1 was unaffected ('papain insensitive'). 3. The hH1 region(s) responsible for this papain sensitivity was localised by testing a series of hH1/hSkM1 chimeras in which combinations of the large hH1 cytoplasmic loops joining the four transmembrane domains replaced analogous hSkM1 loops. Various chimeras were used to determine the smallest subset of loops that converted fully the papain-insensitive hSkM1 into a papain-sensitive channel. Then three converse chimeras were tested in which hSkM1 loops replaced hH1 loops to determine the smallest subset of loops necessary and sufficient to convert the papain-sensitive hH1 into a papain-insensitive channel. 4. Functional studies of this inclusive set of chimeras indicate that the first two cytoplasmic loops of the cardiac sodium channel that join domain I to II (loop A), and domain II to III (loop B), are both necessary, and together are sufficient to produce a papain-induced hyperpolarising shift in the voltage at which channels activate. When both loops are present (wild-type hH1 and the chimera hSkM1AB), V(a) for the channel shifts in the hyperpolarised direction by > 20 mV with papain treatment. When the analogous hSkM1 loops are present (wild-type hSkM1 and the chimera hH1AB), V(a) for the channel is not sensitive to treatment with papain. For channels that contain only one of the two hH1 loops, the effect of papain on V(a) is intermediary. 5. Experiments performed in the absence of papain showed that the activation voltages of the double loop chimeras, hSkM1AB and hH1AB, were shifted significantly from V(a) for hSkM1 and V(a) for hH1, respectively, indicating that these loops directly alter channel activation voltage. The resulting shifts in V(a) were in opposing directions, suggesting that cytoplasmic control of activation voltage is isoform specific. V(a) for hSkM1AB was about 20 mV more depolarised than V(a) for hSkM1, and V(a) for hH1AB was about 9 mV more negative than V(a) for hH1. 6. These data are the first to indicate isoform-specific cytoplasmic regions of the voltage-gated sodium channel that directly and differently alter the voltage of channel activation.

Animals↗

The altering of reported experiences.

OBJECTIVES: The unreliability of human memory is well documented in the literature, yet psychiatrists and other mental health care professionals rely on patient self-report in history-taking. This study provides new evidence from a longitudinal study of autobiographical memory and discusses implications for the development and implementation of appropriate treatment plans and goals. METHOD: Seventy-three mentally healthy 14-year-old males were studied in 1962. Sixty-seven of these subjects were reinterviewed face-to-face at age 48. Questions concerning areas of family relationships, home environment, dating, sexuality, religion, parental discipline, and general activities were asked in both interviews. RESULTS: Significant differences were found between adult memories of adolescence and what was actually reported during adolescence. Accurate memory was generally no better than expected by chance. CONCLUSIONS: If the accurate memory of one's past is not better than chance in the mentally healthy individual, even more care probably should be taken in obtaining accurate historical information in the medically, psychologically, or otherwise health-compromised individual. It would be more constructive to treat recollections as existential reconstructions.

Adolescent↗

Effects of channel cytoplasmic regions on the activation mechanisms of cardiac versus skeletal muscle Na(+) channels.

Functional comparison of skeletal muscle (rSkM1) and cardiac (hH1) voltage-gated sodium channel isoforms expressed in Chinese hamster ovary cells showed rSkM1 half-activation (V(a)) and inactivation (V(i)) voltages 7 and 10 mV more depolarized than hH1 V(a) and V(i), respectively. Internal papain perfusion removed fast inactivation from each isoform and caused a 20-mV hyperpolarizing shift in hH1 V(a), with an insignificant change in rSkM1 V(a). Activation voltage of the inactivation-deficient hH1 mutant, hH1Q3, was nearly identical to wild-type hH1 V(a), both before and after papain treatment, with hH1Q3 V(a) also shifted by nearly 20 mV after internal papain perfusion. These data indicate that while papain removes both hH1 and rSkM1 inactivation, it has a second effect only on hH1 that causes a shift in activation voltage. Internal treatment with an antibody directed against the III-IV linker essentially mimicked papain treatment by removing some inactivation from each isoform and causing a 12-mV shift in hH1 V(a), while rSkM1 V(a) remained constant. This suggests that some channel segment within, near, or interacting with the III-IV linker is involved in establishing hH1 activation voltage. Together the data show that rSkM1 and hH1 activation mechanisms are different and are the first to suggest a role for a cytoplasmic structure in the voltage-dependent activation of cardiac sodium channels.

Amino Acid Sequence↗

Effect of patient personality profile and verbal presentation on successful rigid contact lens adaptation, satisfaction and compliance.

BACKGROUND: Rigid gas permeable (RGP) lenses have numerous benefits, including quality of vision, ocular health, and reduction of myopic progression in young people. Nevertheless, RGP lens use is not increasing in the United States. It is possible that certain patient personality characteristics and/or how a practitioner presents RGP lenses to a new patient may affect satisfaction and success. The purpose of this study was to evaluate the effect of individual patient's personality and the practitioner's method of presenting RGP lenses to new patients on their ability to adapt to these lenses. METHODS: Forty-nine subjects, all noncontact lens wearers, were entered into this 1-month study, which was conducted at both the University of Missouri-St. Louis School of Optometry and the Pacific University College of Optometry. All subjects initially completed standardized questionnaires pertaining to locus of control, openness to new experiences, and motivation/expectations. After diagnostic fitting with a RGP lens material, the subjects were placed into one of the following three groups: (1) Fear-Arousing Non-Enthused; (2) Neutral Content Non-Enthused; or (3) Neutral Content Enthused. They observed one of three video presentations on RGP lens wear. Subjects submitted daily questionnaires providing their evaluation of such factors as comfort, wearing time, and handling. RESULTS: The results showed that there was a significant difference (chi(2) = 6.99; p < 0.05) among the different groups in the number of dropouts: 6/19 with the Fear-Arousing Non-Enthused group, 2/17 with the Neutral Content Non-Enthused group, and 0/13 with the Neutral Content Enthused group. There was also a significant difference (ANOVA F = 4.1, p < 0.05) among the groups on compliance, with the Neutral Content Enthused group demonstrating greater compliance. In terms of satisfaction, there was no significant difference among presentation groups. CONCLUSION: It was concluded that the method of presentation is important for successful RGP contact lens wear. If presented with genuine interest and a positive and realistic attitude, patients are more likely to succeed in RGP lens wear during the initial critical period.

Adaptation, Physiological↗

Effect of topical anesthetic use on initial patient satisfaction and overall success with rigid gas permeable contact lenses.

BACKGROUND: Rigid gas permeable (RGP) contact lenses have numerous benefits; however, RGP lens use is not increasing in the United States. An important factor for this trend has been initial comfort. Studies have demonstrated that how RGPs are presented to patients, in addition to lens design, can play an important role in the initial comfort process. Another important factor could be the use of a topical anesthetic during the fitting and dispensing visits. The purpose of this study was to use a multicenter format to determine if topical anesthetic use increased the likelihood of patient satisfaction and success. METHODS: A total of 80 subjects, with no previous rigid lens wear experience, was entered into this 1-month study, including 20 subjects from each of 4 institutions. Subjects were randomly divided into the following two groups: (A) anesthetic or (B) placebo, with the former group receiving one drop of a topical anesthetic before lens insertion at both the diagnostic fitting and dispensing visits, whereas the latter group received a placebo. Subjects completed a questionnaire on their perception of rigid lens wear both immediately before fitting and at the 1-month visit. After diagnostic fitting with rigid lenses, subjects completed an adaptation questionnaire after 15 min, 1 week, 2 weeks, and 1 month of lens wear. RESULTS: Seventy of the 80 subjects completed the study and, of the 10 subjects who discontinued, 8 were in the placebo group. In all categories evaluated, the anesthetic group experienced a more optimum adaptation experience at each visit vs. the placebo group. Specifically, overall comfort was rated significantly higher at both dispensing and 2 weeks. In addition, the anesthetic group exhibited significantly greater overall satisfaction with rigid lens wear at 2 and 4 weeks. Also, the anesthetic group perceived their adaptation, sensitivity, and adaptation time to be significantly better at the 1-month visit. There was no significant difference in corneal staining between these two groups at each visit, with the exception of a greater amount of staining in the central quadrant for the placebo group at the 1-month visit. CONCLUSIONS: The use of a topical anesthetic at the fitting and dispensing visits for first-time wearers of RGP lenses resulted in significantly fewer dropouts, improved initial comfort, an enhanced perception of the adaptation process, and greater overall satisfaction after 1 month of lens wear as compared to the use of a nonanesthetizing placebo at those visits. This result, in combination with both presenting RGP lenses in a nonthreatening manner and optimizing the lens design and fitting relationship, should result in a positive adaptation process and successful wear of RGP contact lenses.

Adaptation, Physiological↗

Differential adherence of Acanthamoeba to contact lenses: effects of material characteristics.

BACKGROUND: Acanthamoeba-associated keratitis occurs most often in contact lens wearers. The contact lens material may affect its ability to act as a mechanical vector, permitting transfer of viable amoebae from the storage case to the corneal surface. The purpose of this study was to investigate the effects of ionicity and water content on the comparative quantitative adherence of Acanthamoeba trophozoites and cysts to new, unworn hydrogel contact lenses and rigid gas-permeable contact lens materials. METHODS: Sixteen quarter segments of each of 8 types of unworn hydrogel lenses representative of FDA groups 1 to 4 were exposed to freshly prepared cultures of either trophozoites or cysts of A. castellanii or A. polyphaga for 1.5 h, and then washed. Three types of rigid lens button were similarly exposed to A. castellanii trophozoites or cysts. Adherent trophozoites and cysts were then enumerated. RESULTS: All hydrogel lenses showed binding of both trophozoites and cysts, with the former predominating in every case. It was primarily the ionic nature of a lens surface and secondly its water content that was associated with increased quantitative adherence of Acanthamoeba. Neither form of the amoebae bound to any of the hard lens buttons. CONCLUSIONS: Greater relative potential exists for contamination of ionic and high-water content hydrogels by Acanthamoeba. This combination may influence mechanical transmission of the protozoon to the corneal surface. Adherence to hard lenses (as buttons) did not occur if a postincubation wash step was performed.

Acanthamoeba↗

RGP quality control: the results of a national survey.

BACKGROUND: Rigid gas permeable (RGP) contact lenses have numerous benefits; however, one of the possible problems of RGP lenses is variable quality that can result in reduced initial comfort and an unsuccessful fit. METHODS: A quality control survey was sent to 200 optometrists, selected at random, to provide information on lens usage, verification, use of reused or modified lenses, use of authorized laboratory, and to evaluate important laboratory characteristics. A total of 86 optometrists responded to the survey. RESULTS: The results indicated that most respondents fit between 10-25 percent of their new contact lens patients with RGPs. In addition, although both of these parameters can be extremely important to patient success, only 56 percent of the practitioners verify edge quality and even less, 38 percent, verify center thickness. Sixty-seven percent of the practitioners indicated that poor initial wettability occurred in, at minimum, 5-10 percent of all new lenses. 75 percent of the practitioners indicated that it would matter to them if the supposed new lenses had previously been used or modified. Finally, optical quality and lens parameter accuracy were considered much more important than turnaround time and material cost. CONCLUSIONS: It appears from these results that variance in quality control can result in compromised lens quality and performance. In addition, it can be reduced by more careful lens inspection by the practitioner. If careful attention is devoted to these recommendations, RGP lens use and success could increase accordingly.

Contact Lenses↗

The phenol red thread tear test: a cross-cultural study.

PURPOSE: To examine the results of the phenol red thread tear test in a cross-cultural comparison. METHODS: Two groups of 500 controlled normal subjects who do not wear contact lenses from the United States and Japan were investigated. RESULTS: The mean wet length of the thread for the United States was 23.9 mm (SD 9.5 mm). The mean for Japan was 18.8 mm (SD 8.6 mm). There was a significant difference between the two countries (P < 0.05). Males subjects had significantly longer wet lengths than females for both countries (P < 0.05). There was a moderate correlation between right and left eye results for both countries. CONCLUSIONS: The phenol red thread tear test was found to be easy to administer. Results were in line with current knowledge and theories of the lacrimal system. Results also indicated that this test may disclose subtle differences not previously found with other tear tests.

Adolescent↗

Initial comfort and surface wettability: a comparison between different contact lens materials.

A clinical investigation was performed to compare the initial comfort and surface wettability of the Novalens (Ocu-Tec), ENVISION (Polymer Technology Corporation) and D3X4 (Wesley-Jessen). Fifteen subjects were randomly fit with each one of these three lens materials. Initial comfort was significantly better with the D3X4 lens; no significant difference was found between the two rigid lens materials. No significant difference in lens surface wettability was found between the three materials.

Adult↗

The effect of contact lens cleaners on lens parameters and surface quality of the Novalens.

The purpose of this study is to evaluate the effect of one abrasive cleaner, one non-abrasive cleaner and one non-abrasive alcohol-based cleaner on the lens parameter stability of the NOVALENS. Twenty-four lenses, all NOVALENS material of identical design, were cleaned 100 times each. Eight lenses were cleaned with MiraFlow (CIBA Vision), eight lenses with Optic-Free Daily Cleaner and eight lenses with the Gas Permeable Daily Cleaner (PBH). The base curve radius, center thickness and power were verified immediately before, immediately after and (per manufacturer's recommendation) 4 hours after cleaning at baseline, 25, 50, 75 and 100 cleanings. Lens toricity of approximately 0.50D was found with all three cleaners after 100 cleanings. No change in lens power or center thickness was found. It was concluded that extreme care must be taken in handling the NOVALENS due to the potential of induced warpage.

Contact Lenses↗

Clinical evaluation of fitting presbyopic patients with contact lenses.

This clinical investigation was performed to determine the success of using a system designed as a flow chart to fit presbyopic patients with contact lenses. The value of this type of system is to provide practitioners with a simple step-by-step approach to fitting presbyopic patients and reducing the costs of several trial fitting sets. Patients were fit with monovision, simultaneous vision bifocal, alternating vision bifocal or diffractive bifocal contact lenses. The patients were fit first with monovision, and, if unsuccessful with this or any of the above lens designs, they proceeded to the next stage. Stage 2 used the simultaneous lens design, Stage 3 the alternating lens design and Stage 4 the diffractive lens design. Of the 22 patients enrolled in the study, 17 (77.3 percent) were successful through Stage 3 and 18 (81.8 percent) were successful through Stage 4. The first three stages are those proposed by Bausch & Lomb as the Presbyopic Fitting System. The Presbyopic Fitting System was found to be simple to follow and successful in fitting presbyopic patients.

Adult↗

The effect of rigid gas permeable lens cleaners on lens parameter stability.

The introduction of fluoro-silicone/acrylate rigid lens materials has provided wearers with benefits that include, among others, enhanced surface wettability. However, several reports have associated these lens materials with lens power, base curve radius and center thickness changes over time, especially with long-term use of an abrasive cleaner. The purpose of this study was to evaluate the effect of abrasive and non-abrasive cleaners on these specific lens parameters. Twenty-four fluoro-silicone/acrylate lenses, 12 low minus and 12 high minus in power, were cleaned a total of 200 times each. Each lens was cleaned with one of-three different cleaners (1 non-abrasive and 2 abrasive) using one of two cleaning methods; palm of the hand or between the fingers (digital). Lens power was changed on 14/24 lenses (58.3 percent); the primary changes occurred with use of one of the abrasive cleaners. In addition, a slight reduction in center thickness was observed after abrasive cleaner use. Warpage occurred at a much higher rate with the digital cleaning method and with the use of an abrasive cleaner. It was concluded that practitioners should routinely reverify rigid lens power, center thickness and base curve radius; patients should be educated to carefully handle their lenses, notably cleaning them in the palm of the hand.

Contact Lenses↗

The effect of modification procedures on rigid gas permeable contact lenses: the UM-St. Louis Study.

The purpose of this study is to evaluate the effect of frequently performed modification procedures on quality of vision, surface wettability, optical quality and subjective response. One subject was optimally fitted with both silicone/acrylate (S/A) and fluoro-silicone/acrylate (F-S/A) lens materials of identical design. Two methods of surface polishing, edge polishing and repowering were used in addition to three different spindle speeds. Each pair of lenses was worn by the subject for a period of 4 hours and the subjective response was then compared to the baseline or premodification data. In addition, both low magnification photography and Scanning Electron Microscopy (S.E.M.) were performed on each lens. The results showed that the addition of 0.50D minus power reduced visual acuity, contrast sensitivity function and optical quality with one of the methods used. Front surface polish and edge polish procedures did not appear to affect short-term performance. Controlling polish, application and tool pressure on certain procedures resulted in similar findings. Further studies would be beneficial to evaluate the effect of longer wearing periods and the use of other modification procedures. The authors conclude that S/A and F-S/A lens materials can be successfully modified in-office with adherence to recommended guidelines.

Contact Lenses↗

How important are lens oxygen ratings? They are one of many performance factors.

To prevent corneal edema in most patients, contact lenses must transmit oxygen to the following minimum degree: (a) in daily wear, 24.1 x 10(-9) (cm x ml O2)/(s x ml x mm Hg), and (b) in extended wear, 34.3 x 10(-9) (cm x ml O2)/(s x ml x mm Hg). High Dk/L ratings are particularly important for patients wearing extended wear lenses and for those with exceptionally high corneal oxygen demand. Nevertheless, it is well known that other lens performance properties can be compromised by manipulating material or design parameters to increase the Dk/L rating. Increasing the Dk/L of hydrogel lenses, for example, may lead to problems such as fragility, dehydration, and corneal adherence. Similarly, high-Dk/L, rigid gas-permeable lenses may exhibit poor surface wettability and flexural resistance, base curve radius changes, and possible corneal adherence. Because such problems can compromise visual acuity, affect ease of handling, or decrease comfort, nonoxygen factors may exert a stronger influence on successful lens wear than high oxygen transmissibility alone for most patients. Among the nonoxygen factors important for contact lens wear are good movement, surface wettability, resistance to deposit buildup, and flexural resistance. Clinicians must consider these properties, along with oxygen transmission ratings, when fitting patients with contact lenses. Lenses that exhibit good overall performance, in my view, provide the greatest probability of successful wear.

Contact Lenses↗

Clinical investigation of the Paraperm EW rigid gas-permeable contact lens.

Paraperm EW is a high oxygen flux silicone/acrylate rigid lens material currently under clinical investigation for extended wear. The purpose of this paper is to report the clinical findings after 12 months of a 2-year investigation of 18 patients fitted with this material. Fifteen were successfully wearing Paraperm EW lenses at 1 year. The only significant clinical finding was keratometric flattening at the 1-month visit. It was concluded that the Paraperm EW lens was durable, comfortable, and provided excellent visual acuity during the course of this investigation without inducing any of the ocular complications sometimes associated with extended wear of hydrogel lenses.

Adolescent↗

Evaluation of endothelial integrity in extended wear.

The purpose of this investigation was two-fold: 1) to evaluate and compare the endothelium of hydrogel and rigid extended wear contact lens patients and 2) to evaluate a new technique for in-office endothelial photography. Endothelial photography was performed on seven patients who had worn low water content ultrathin soft lenses and seven patients who had worn rigid extended wear lenses for 1 year. In addition, seven non-lens wearers were used as a control group. Endothelial polymegathism and pleomorphic changes were evaluated via photographic observation using a new endothelial photography technique developed by G. Michael Murphy, O.D. The results showed that this was a viable method of endothelial photography for monitoring extended wear contact lens patients.

Conjunctival Diseases↗

Hydrogel versus rigid gas permeable lenses for extended wear: criteria and differences.

The clinical investigation of several high oxygen flux lens materials has demonstrated that practitioners should soon have a viable alternative to hydrogel extended wear lenses. Practitioners can base their decision on several factors prior to selecting the appropriate lens. In many cases a rigid lens may be the appropriate alternative based on these factors.

Contact Lenses, Extended-Wear↗