Search PubMed⌕ Search

Biomedical subjects

E Rostrup

Publications and source records attributed to E Rostrup.

36 records · Page 2Linked to original sources

Capillary transfer constant of Gd-DTPA in the myocardium at rest and during vasodilation assessed by MRI.

The purpose of this study was to determine whether the capillary transfer constant (Ki) of gadolinium-DTPA was sensitive to perfusion changes and whether ischemic regions in the myocardium could be identified using the modified Kety formula. Ki was measured at rest and during dipyridamole-induced vasodilation in 10 healthy volunteers and in 10 patients with ischemic heart disease. Ki increased by a factor of 2.5+/-1.2 (mean +/- SD) from 55+/-16 ml 100 g(-1)min(-1) at rest to 136+/-46 ml 100 g(-1)min(-1) (P < 0.01) during vasodilation in the healthy subjects. In the patients, there were no changes in Ki during vasodilation in ischemic regions (50+/-18 versus 49+/-30 ml 100 g(-1)min(-1) (P > 0.4)). Ki increased in nonischemic regions by a factor of 2.0+/-0.8 from 44+/-17 to 81+/-32 ml 100 g(-1)min(-1) during vasodilation (P < 0.02). It is concluded that the capillary transfer constant is sensitive to perfusion changes and that regional ischemia can be detected with MRI. This noninvasive and quantitative method may prove useful in the evaluation of patients with ischemic heart disease.

Adult↗

Quantification of gadolinium-DTPA concentrations for different inversion times using an IR-turbo flash pulse sequence: a study on optimizing multislice perfusion imaging.

The purpose of this study was to optimize an inversion-recovery (IR) turbo fast low-angle shot (FLASH) for multislice imaging by evaluating the accuracy of calculated the relaxation-rate (R1) for different inversion times (TI). This is important for tracer kinetic modeling because it requires a system responding linearly to input. R1 are linearly related to changes in the concentration of gadolinium (Gd)-diethylenetriaminepentaacetic acid (DTPA), and R1 is a parameter that can be derived from the magnetic resonance (MR) signal. The accuracy of calculated R1 using an IR turbo fast low-angle shot was evaluated in phantoms and for increasing TIs using spectroscopically measured R1 values as reference. Signal curves, obtained in vivo after a bolus injection of Gd-DTPA, were used in an analytical computer program to study the effect of different TI-values on accurate calculation of R1. Results show that TIeff should be <200 ms to measure the bolus-passage of Gd-DTPA in blood accurately, whereas the myocardial response can be measured correctly for TIeff < 870 ms at 1.5 T. The initial slope of the myocardial signal enhancement curve becomes steeper for larger TI values, whereas the calculated R1 curves were similar, indicating that these curves, rather than signal curves, are more suitable even for qualitative perfusion evaluation. It is concluded that the results can be incorporated in a multislice IR turbo fast low-angle shot using the first slice (with a short TI) for assessment of both the arterial input function and the tissue response and the second slice in another position for assessment of the tissue response alone.

Contrast Media↗

Parieto-occipital cortex activation during self-generated eye movements in the dark.

A number of extrastriate visual areas in the parieto-occipital cortex are known from single-cell recordings of the macaque monkey to be involved in the coding of eye-position signals in the brain. These are important for the accurate location of visual objects in extrapersonal space. It can be predicted that these areas will show increased activation during the performance of eye movements at high frequency. In the present study PET and measurements of the regional distribution of cerebral blood flow (rCBF) were used as indirect measures of neural activity. Two independent groups of normal volunteers performed large-amplitude self-generated eye movements in complete darkness, thus removing the confounding effects of visual stimulation on parieto-occipital activation. The first group (group A; n = 5) served as a hypothesis-generating group and the second group (group B; n = 4) served as a hypothesis-testing group. The data were analysed using statistical parametric mapping at a significance level corrected for multiple comparisons (group A, Z > 4.08; group B, Z > 4.04). Significant rCBF increases were found for both groups in the frontal eye fields, supplementary eye fields, cerebellar vermis and putamina/thalami. Additionally, activation was found in the cunei in the posterior bank of the parieto-occipital sulcus. Also, the extraocular muscles were activated and, as a consequence of the partial volume effect, projected to the orbitofrontal cortices. At a less conservative threshold, activation was found close to the intraparietal sulci on the left side (Z = 3.91, P = 0.09) and right side (Z = 3.33, P = 0.42). The locations of these areas were confirmed in group B with reference to high-resolution structural MRI scans. The activation of the parieto-occipital cortex without overt visual stimuli is interpreted as the result of neural activity related to the reception of efferent copies of motor commands and/or the activation of neurons coding for eye position relative to the orbits. These are important constituents for the location and remapping of visual stimuli in space.

Adult↗

Visual activation in infants and young children studied by functional magnetic resonance imaging.

The purpose of this study was to determine whether visual stimulation in sleeping infants and young children can be examined by functional magnetic resonance imaging. We studied 17 children, aged 3 d to 48 mo, and three healthy adults. Visual stimulation was performed with 8-Hz flickering light through the sleeping childs' closed eyelids. Functional magnetic resonance imaging was performed with a gradient echoplanar sequence in a l.5-T magnetic resonance scanner. Six subjects were excluded because of movement artifacts; the youngest infant showed no response. In 10 children, we could demonstrate areas of signal decrease during visual stimulation in the occipital cortex (mean decrease 2.21%), contrary to the signal increase observed in the adult controls (mean increase 2.82%). This decrease may be due to a higher proportional increase in oxygen extraction compared with increase in cerebral blood flow during activation. The different response patterns in young children and adults can reflect developmental or behavioral differences. Localization of the activation seemed to be age-dependent. In the older children and the adults, it encompassed the whole length of the calcarine sulcus, whereas it was restricted to the anterior and medial part of the calcarine sulcus in the younger infants. This may reflect a different functional organization of the young child's visual cortex or the on-going retinal development.

Adult↗

Myocardial perfusion modeling using MRI.

In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery turbo-FLASH (fast low-angle shot) sequence and Gd-DTPA has been presented. Here, an extension of the model is presented taking into account fast and slow water exchange between the compartments, enabling the calculation of the unidirectional influx constant (Ki) for Gd-DTPA, the distribution volume of Gd-DTPA (lambda), the vascular blood volume (Vb), and the time delay through the coronary arteries (delta T). The model was evaluated by computer simulation and used on experimental results from seven healthy subjects. The results in the healthy volunteers for a region of interest placed in the anterior myocardial wall were (mean +/- SD) Ki = 54 +/- 10 ml/100 g/min, lambda = 30 +/- 3 ml/100 g, Vb = 9 +/- 2 ml/100 g, delta T = 3.2 +/- 1.1 s. These results are in good agreement with similar results obtained by other methods.

Adult↗

Measurement of the arterial concentration of Gd-DTPA using MRI: a step toward quantitative perfusion imaging.

A noninvasive method using an inversion recovery turbo-FLASH for dynamic measurement of the arterial input function represented by the bolus passage of Gd-DTPA in the descending aorta is presented, and the results are compared with the input function obtained by arterial blood samples. A good accordance between the two input functions was found, indicating that it is possible to measure the input function to the myocardium using MRI. A variation between the two concentration curves of 5% at upslope, 2.7% at peak point, and < 7% at downslope was found. The study also indicates that a short inversion time < 250 ms has to be used to ensure correct measurement of peak concentration.

Adult↗

Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain.

PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged 24-29 years) were studied during inhalation of atmospheric air and 7% CO2. A bolus injection of Gd-DTPA was given during the acquisition of a series of susceptibility-weighted, fast gradient echo images (TR/TE = 27/22 ms). The images were converted to delta R2* maps, and CBV was calculated pixelwise by fitting a gamma-variate function to the data. The tissue concentration vs time curves were deconvoluted using an input function obtained by arterial sampling. RESULTS: The ratio of gray to white matter CBV (1.9-2.5) as well as the fractional increase in rCBV during hypercapnia (about 30%) was found to be in accordance with results obtained by other methods. Noncontrast functional MR (fMR) imaging showed signal increases in gray matter, but also inconsistent changes in some white matter regions. CONCLUSION: In this experiment, contrast-enhanced imaging seemed to show a somewhat higher sensitivity towards changes in cerebral hemodynamics than noncontrast-enhanced imaging. The results of the deconvolution analysis suggested that perfusion calculation by conventional tracer kinetic methods may be impracticable because of nonlinear effects in contrast-enhanced MR imaging.

Administration, Inhalation↗

Signal changes in gradient echo images of human brain induced by hypo- and hyperoxia.

The effect of hypoxia (inspired oxygen fraction, FiO2 of 10% and 16%) and hyperoxia (FiO2) of 100%) on gradient echo images of the brain using long echo times was investigated in six healthy volunteers (age 24-28 years). Different flip angles were used with an FiO2 of 10% to assess the importance of saturation effects. The total cerebral blood flow was measured by a phase mapping technique during normoxia as well as hypoxia (FiO2 of 10% and 16%) and hyperoxia (FiO2 of 50% and 100%). High relative signal changes were found, independently of the flip angle, with FiO2 of 10%. With a flip angle of 40 degrees the values of delta R2* for cortical grey matter, central grey matter, white matter and the sagittal sinus were 0.79, 0.41, 0.26 and 3.00/s; with a flip angle of 10 degrees the corresponding values were 0.70, 0.37, 0.24 and 3.15/s. The total cerebral blood flow increased by 41% during inhalation of 10% O2 and decreased by 27% during 100% O2; no flow changes were seen during moderate changes in FiO2. It is concluded that flow effects play a minor role for fMRI signal strength in this application since (i) they did not abolish the signal changes caused by changes in blood oxygenation during hyper- and hypoxia, (ii) the observed signal changes were closely related to the changes in arterial oxygen saturation during hypoxia and (iii) the signal changes were little affected by changing the flip angle from 40 degrees to 10 degrees.

Adult↗

Cerebral energy metabolism during hypoxaemia. A 31P and 1H magnetic resonance study.

By means of proton and phosphorous magnetic resonance spectroscopy at 1.5 Tesla the human cerebral metabolism was investigated during mild and moderate hypoxaemia. Seven volunteers participated and spectra were obtained while the subjects were breathing atmospheric air, 16, 12 and 10% oxygen in N2.PaO2, PCO2 and arterial oxygen saturation were determined during the spectroscopic measurements. Haemodynamic and respiratory mechanisms compensated the hypoxic condition and no lactate production was found. There was no change in N-acetyl-aspartate. No change in intracellular pH was found. A slight but non-significant decrease in PCr/P(i)-ratio was found, indicating a decrease in the phosphorylation potential of the brain in response to hypoxaemia. The brain sustains aerobic metabolism during mild to moderate hypoxaemia.

Adult↗

Functional MRI of CO2 induced increase in cerebral perfusion.

The sensitivity of MR gradient echo imaging towards CO2 induced changes in cerebral blood flow was investigated in 10 normal subjects. The subjects were inhaling 5% and 7% CO2 and the experiments were carried out at 1.5 T (n = 6) and 2.0 T (n = 5), allowing a comparison of field strengths. Additional experiments were carried out using a higher spatial resolution. The largest signal increases were noted in areas corresponding to larger vessels, but significant changes were also conspicuous in deeper cortical and central grey matter. The changes appeared linearly related to the arterial CO2 tension, within the range of PaCO2 studied. In white matter, the changes were not statistically significant.

Administration, Inhalation↗

Effects of aluminum (III) and fluoride on the demineralization of bovine enamel: a longitudinal microradiographic study.

Longitudinal microradiography has been used to determine inhibiting effects of aluminum (III), Al, and fluoride on mineral loss from slices of bovine enamel exposed to a demineralizing solution 4 h daily for 35 days. Inhibitor treatment was 5 min four times daily. For the remaining time, the samples were immersed in a neutral calcium phosphate solution which allowed neither remineralization nor demineralization. This study indicates that a 1-mM (27 ppm) solution of Al in a 0.1-M lactate solution, pH 5, has an inhibitory effect on the in vitro demineralization of bovine enamel. Application of this solution alternating with 20 mM (380 ppm) fluoride gave the same total inhibition as treatment with 20 mM fluoride alone.

Alum Compounds↗

Histochemical characterization of pig masseter muscle: an animal model.

Masseter muscle autopsies were obtained from six different areas of six pigs. The autopsies were stained for the demonstration of myosin ATPase activity by means of a conventional histochemical technique. As compared with human masseter, the pig masseter muscle contained more type II fibers. But, like the human masseter, the pig muscle had a varying distribution of fiber types in the different autopsy areas, a distribution which might be the result of an adaptation to carry out special functions such as chewing, swallowing, and jaw posture. The fiber type distribution in the pig masseter also varied among individuals, probably reflecting various levels of utilization of the muscles besides different genetic influences. Moreover, pig masseter contained fibers of intermediate staining intensity (IM fibers), a fiber type rarely seen except in human masticatory muscles. In conclusion, we consider the pig masseter to be a useful animal model to study muscular adaptations to altered function in the orofacial region.

Adenosine Triphosphatases↗

Functional MR imaging at 1.5 T. Initial results using photic and motoric stimulation.

A preliminary investigation of the effects of stimulation of the visual and the motor cortex was made on a conventional 1.5 T MR imaging scanner. Both types of activation gave a detectable change in the signal between rest and stimulation using a gradient echo sequence with an echo time of 60 ms. The observed effects were assumed to be caused by variation in the amount of paramagnetic deoxyhemoglobin between stimulation and rest due to local increase of capillary blood flow in the human brain during stimulation.

Brain↗

Monoaminergic systems in the brainstem and spinal cord of the turtle Pseudemys scripta elegans as revealed by antibodies against serotonin and tyrosine hydroxylase.

With the aim of gaining more insight into the monoaminergic regulation of spinal motor systems in the turtle, we have studied the distribution of 5-HT (5-HTir) and tyrosine hydroxylase immunoreactivity (THir) in the brainstem and spinal cord of Pseudemys scripta elegans. 5-HTir cell bodies were located in the midline in nucleus raphe inferior, nucleus raphe superior, and laterally in nuclei reticularis superior and inferior and nucleus reticularis isthmi. THir cell bodies were located in the commissural nucleus, nucleus tractus solitarii, the locus coeruleus-subcoeruleus complex, nuclei reticularis superior and inferior, the pretectal area, and substantia nigra. 5-HTir and THir tracts were found in lateral and ventral bundles superficially in the brainstem. 5-HTir fibers in the spinal cord were located in a large dorsolateral and a smaller ventrolateral tract. In the gray matter, a high concentration of 5-HTir fibers were observed in areas I-IV and in the lateral motor column of cervical and lumbar enlargements. Areas V-VIII and area X were less intensively innervated, with the lowest fibre concentration in areas VII-VIII and area X. Throughout the spinal cord, THir nerve fibres were located in the same areas but with a lower density. Small bipolar 5-HTir and THir cell bodies were found ventromedially to the central canal especially in cervical and lumbosacral segments. Large THir cells were found in area IX in the caudal sacral and coccygeal spinal cord. THir cerebrospinal fluid-contacting cells were also found in the most caudal part of the brainstem and the upper cervical spinal cord. The well developed spinal 5-HT system and the less developed THir system provides an anatomical explanation for the monoaminergic modulation of turtle motoneuron membrane properties, which has been observed in electrophysiological experiments.

Animals↗

Interaction of cadmium ions with calcium hydroxyapatite crystals: a possible mechanism contributing to the pathogenesis of cadmium-induced bone diseases.

Cadmium ions adsorb onto calcium hydroxyapatite crystals (HA) and are as effective as inorganic pyrophosphate and aluminum ions in retarding the rate of in vitro dissolution of HA. In contrast, cadmium ions have no important retarding effect on the growth of HA, but are built into the crystals, thus making them very resistant to subsequent dissolution. These effects could interfere with bone remodeling, with cadmium protecting normal sites of resorption and thus causing resorption at pathological sites.

Bone Diseases, Metabolic↗

Histological and histomorphometrical evaluation of tissue reactions adjacent to endosteal implants in monkeys.

A qualitative and quantitative histological study of the initial healing response adjacent to 24 submerged and non-submerged implants placed in the lower jaws of 6 monkeys is presented. The histomorphometric analysis showed no significant differences in mineralized bone-implant contact length between submerged and non-loaded non-submerged titanium implants. The infrabony defects around some of the implants on the radiographs were significantly correlated to the histological measurements. Qualitatively, a greater number of gingival inflammation cells and a longer junctional epithelium were seen adjacent to non-submerged implants without oral hygiene than were seen adjacent to non-submerged implants with oral hygiene in the initial healing period.

Animals↗