Search PubMed⌕ Search

Biomedical subjects

E Roets

Publications and source records attributed to E Roets.

At least 19 recordsLinked to original sources

Analysis of clindamycin by micellar electrokinetic chromatography with a mixed micellar system.

This study details the development and validation of an optimized method with micellar electrokinetic chromatography for the analysis of clindamycin. The method uses a mixed micellar phase containing anionic sodium dodecylsulfate (SDS) and non ionic Brij 35 on an untreated fused-silica capillary. The influences of buffer concentration, pH, SDS, Brij 35 and organic modifier were investigated. Special attention was given to the role of the non ionic Brij 35 in the mixed micellar system. Optimization with a central composite design resulted in optimal separation conditions: background electrolyte containing 25 mM sodium tetraborate pH 7.75, 90 mM SDS, 14 mM Brij 35 and 21% acetonitrile. The applied voltage was 15 kV and the capillary temperature 15 degrees C. The method was robust and gave good linearity and repeatability. The limits of detection and quantitation were 0.05 and 0.15%, respectively, relative to a 2.5 mg/ml clindamycin solution. Two commercial bulk products were analysed with this system.

Anti-Bacterial Agents↗

Development and validation of a simple capillary zone electrophoresis method for the analysis of kanamycin sulfate with UV detection after pre-capillary derivatization.

Capillary zone electrophoresis was successfully applied to separate eight related substances of kanamycin and several minor unknowns from the main component. Strategies to enhance derivatization and selectivity and to optimize separation parameters involved the application of experimental designs. This chemometrical approach considers main effects as well as interactions of the influential parameters, thus conducting a more thorough investigation of the method than the common step-by-step approach. Central composite face centered designs established optimal separation conditions: 30 mM borax buffer, pH 10.0 containing 16.0% (v/v) methanol and optimal composition of derivatization reagent: 27 mg/ml 1,2-phthalic dicarboxaldehyde and 25 microl/ml mercaptoacetic acid in borate buffer, pH 10.4. The standard curves were linear over the concentration range of 0.007-1.01 mg/ml for the main component and 0.003-0.1 mg/ml for the related substances. The limit of quantitation was 0.14% (m/m) for the related substances and impurities (S/N= 10). The assay method was used to determine the composition of several commercial samples. Quantitative analysis indicates potential usefulness of capillary electrophoresis as an alternative to the assay method prescribed in the European Pharmacopoeia and the United States Pharmacopeia.

Anti-Bacterial Agents↗

Liquid chromatography of troleandomycin.

Until now no liquid chromatography (LC) method is described to determine the purity and content of troleandomycin and its related substances. A simple, robust, sensitive and selective isocratic liquid chromatographic method suitable for the determination of the antibiotic troleandomycin and its related substances is described. This method utilizes as a stationary phase: XTerra RP18 5 microm (25 cm x 4.6 mm I.D.) at 30 degrees C and as mobile phase: acetonitrile-0.2 M ammonium acetate buffer (pH 6.0)-water (45:5:50, v/v), delivered at a flow-rate of 1.0 ml/min. UV detection is performed at 205 nm. Troleandomycin is separated from the partially acetylated related substances and from several unknown impurities present in commercial samples. The robustness of the method was evaluated by a full-factorial experimental design.

Anti-Bacterial Agents↗

Isolation and structural characterization of polymyxin B components.

Polymyxin B is a peptide antibiotic complex present as sulphate. The components were separated preparatively on a poly(styrene-divinylbenzene) (PLRP-S), 1000 A, 8 microm, 250 x 12.5 mm I.D. stationary phase maintained at 60 degrees C and using 215 nm detection. Elution was carried out with acetonitrile-sodium sulphate solution (0.7%, m/v; pH adjusted to 2.5 with trifluoroacetic acid)-water (18:50:32, v/v) at a flow-rate of 4.0 ml/min. Seven polymyxin B components were isolated and characterized using 1H and 13C NMR. The molecular masses were confirmed by mass spectrometry. The structures of two components were determined for the first time. Polymyxins B5 and B6 were identified as having the same composition as polymyxin B1 except that the fatty acid moiety was nonanoic acid and 3-hydroxy-6-methyloctanoic acid, respectively.

Chromatography, Liquid↗

Structure elucidation of four related substances in gramicidin with liquid chromatography/mass spectrometry.

A selective reversed phase liquid chromatography/mass spectrometry (LC/MS(n)) method is described for the identification of related substances in commercial gramicidin samples. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an electrospray interface operated in the positive and the negative ion mode. The LCQ is ideally suited for identification of related substances because it provides on-line LC/MS(n) capability. Compared with UV detection the main advantage of this hyphenated LC/MS(n) technique is the efficient identification of novel related substances without time-consuming isolation and purification procedures. Using this method four novel related substances were separated and identified in a commercial sample.

Amino Acid Sequence↗

Analysis of metacycline by capillary electrophoresis.

The development and validation of an optimized capillary electrophoresis method for the determination of metacycline in the presence of its related substances by capillary electrophoresis is shown. The influence of methanol as organic modifier, buffer pH, buffer concentration, capillary length, column temperature, Triton X-100 and methyl-beta-cyclodextrin was investigated. A central composite design was performed in order to optimize the method. The optimal separation conditions were: uncoated fused-silica capillary (39 cm total length, 31 cm effective length, 50 microm ID); as background electrolyte a solution of 160 mM sodium carbonate and 1 mM EDTA (pH 10.35)/methanol (89:13 v/v); temperature, 15 degrees C; voltage, 12 kV. The method showed good selectivity, repeatability, linearity, and sensitivity. The limits of detection and quantitation are 0.024% and 0.06%, respectively, relative to a 2.5 mg/mL solution. Six commercial samples were analyzed quantitatively.

Automation↗

Analysis of bacitracin by micellar electrokinetic capillary chromatography with mixed micelle in acidic solution.

A method used for quantitative analysis of bacitracin with micellar electrokinetic capillary chromatography (MEKC) is described. As capillary zone electrophoresis gave poor separation selectivity, MEKC was preferable. It was found that a zwitterionic surfactant, 3-(N,N-dimethylhexadecylammonium)-propanesulfonate (PAPS) gave the best selectivity among the several surfactants studied. As the analytes tend to adsorb onto the capillary wall due to their positive charge, an acidic solution composed of Tris-phosphate buffer at pH 2.5 was necessary to diminish such adsorption. The peak tailing caused by relatively strong ion pair interaction between the analyte and PAPS micelle could be reduced by adding nonionic surfactant Brij 35 to the PAPS solution. This phenomenon is possibly explained by a mixed micelle mechanism. In order to obtain the optimal conditions and to test the method robustness, a central composite experimental design was performed. The optimal conditions are as follows: 44 cm length of fused-silica capillary with 50 microm inner diameter, 90 mM Tris-phosphate buffer (pH 2.5) containing 17 mM PAPS and 0.3% w/v-Brij 35, 18 kV applied voltage, UV detection at 192 nm and 25 degrees C column temperature. Under the optimal conditions, more than 50 peaks could be obtained in 30 min. The method had a linearity range from 1 to 0.05 mg/mL (concentration of bacitracin A). The limit of quantitation (LOQ) and limit of detection (LOD) were 0.005 and 0.0012 mg/mL, respectively.

Bacitracin↗

Analysis of vancomycin and related impurities by micellar electrokinetic capillary chromatography. Method development and validation.

A fast and highly selective micellar electrokinetic capillary chromatography (MEKC) method for quantitative analysis of vancomycin and related impurities is described. Among the tested surfactants, cetyltrimethylammonium chloride (CTAC) offered the best selectivity. Another important parameter, which strongly influenced the selectivity, was buffer pH. It was found that the selectivity increased with buffer pH decreasing from 9 to 5. Using Tris-phosphate buffer containing CTAC, satisfactory separation could be obtained in the pH range from 5.0 to 5.5. Excellent repeatability in terms of migration time and peak area could be obtained when the capillary was carefully washed between two runs. In order to obtain optimal conditions and to evaluate the method robustness, a central composite experimental design was carried out. The optimal conditions were: 44 cm length of fused-silica capillary with 50 microm ID, 120 mM Tris-phosphate buffer (pH 5.2) containing 50 mM CTAC, -15 kV applied voltage, UV detection at 210 nm, and a column temperature of 25 degrees C. Under the optimal conditions, more than 20 peaks could be separated within 8 min. The method has a linearity range from 0.004 to 1.2 mg/ml (concentration of vancomycin B, active component). The limit of detection (LOD) and limit of quantitation (LOQ) were 0.4 microg/mL vancomycin, equivalent to 0.3 microg/mL vancomycin B (0.04%) and 1.1 microg/mL vancomycin, equivalent to 0.9 microg/mL vancomycin B (0.1%), respectively.

Aminoglycosides↗

Electrophoretically mediated microanalysis of gentamicin with in-capillary derivatization and UV detection.

This paper describes a system for integration of a one-step-microscale chemical derivatization and analysis by a methodology known as electrophoretically mediated microanalysis (EMMA). Differential electrophoretic mobility between an analyte, reagent, and their product offers EMMA a unique capability to selectively carry out electrophoretic mixing, control product formation, and separation. This system was successfully applied to perform derivatization and separation of the multicomponent aminoglycoside antibiotic gentamicin using 1,2-phthalic dicarboxaldehyde and mercaptoacetic acid as labeling reagents. A multivariate approach based on central composite experimental design was used to optimize the derivative yield. Full automation of the derivatization and analytical procedure, high derivatization efficiency, high sample throughput, and precision are the excellent features of the present method. In addition, this methodology offers short analysis time, as well as selectivity and sensitivity suitable for impurities determination. Separation of gentamicin C1, C1a, C2, C2a, C2b, sisomicin, and several minor components was achieved. For the first time separation and identification of three impurities, namely garamine, 2-deoxystreptamine, and paromamine are described.

Anti-Bacterial Agents↗

Isolation and structural characterization of colistin components.

Preparative-scale separation of colistin sulphate bulk sample was carried out on a preparative poly(styrene-divinylbenzene) stationary phase. Isocratic elution with acetonitrile-sodium sulphate solution (0.7% m/v; pH adjusted to 2.5 with TFA) - water (16:50:34, % v/v/v) was carried out at a flow rate of 4.0 ml min(-1). Six colistin components were isolated and characterized using 1H and 13C NMR. The molecular weights were confirmed by mass spectrometry. The structures of 2 components were determined for the first time. Polymyxin E7 was identified as having the same composition as polymyxin E1, except that the fatty acid moiety was 7-methyloctanoic acid. Isoleucine polymyxin E8 was characterized as having the same composition as isoleucine polymyxin E1 with 7-methylnonanoic acid as the fatty acid moiety.

Anti-Bacterial Agents↗

Liquid chromatographic analysis of streptomycin sulfate.

The analysis of streptomycin sulfate using a column packed with base deactivated reversed phase silica gel and ultraviolet (UV) detection at 205 nm is described. The mobile phase consists of an aqueous solution containing 14 g/l of sodium sulfate, 1.5 g/l of sodium octanesulfonate, 50 ml/l of acetonitrile and 50 ml/l of a 0.2 M phosphate buffer at pH 3.0. The method allows separating streptidine, streptomycin B, streptomycin and dihydrostreptomycin, as well as several other components, which were not yet identified. The total time of analysis is 50 min. The effects of the different chromatographic parameters on the separation were investigated. A number of commercial samples were analyzed using this method.

Anti-Bacterial Agents↗

Capillary electrophoresis analysis of gentamicin sulphate with UV detection after pre-capillary derivatization with 1,2-phthalic dicarboxaldehyde and mercaptoacetic acid.

A selective, sensitive, and rapid pre-capillary derivatization method for determination of the multicomponent aminoglycoside antibiotic gentamicin is described. The derivatization reagents 1,2-phthalic dicarboxaldehyde and mercaptoacetic acid were used and the thioisoindole derivative was UV detected at 330 nm. A central composite experimental design was performed to optimize selectivity and derivatization conditions. Baseline separation of gentamicin C1, C1a, C2, C2a, C2b, sisomicin and several minor components was achieved with a background electrolyte containing 30 mM sodium tetraborate, 7.5 mM beta-cyclodextrin and 12.5% (v/v) methanol at pH 10. Quantitative analysis was performed and illustrated the potential use of capillary electrophoresis for the identification and quantitation of gentamicin as an alternative to methods prescribed in the United States Pharmacopeia and European Pharmacopoeia.

Electrophoresis, Capillary↗

Analysis of doxycycline by capillary electrophoresis. Method development and validation.

An optimized capillary electrophoresis method for the analysis of doxycycline is described. The influence of methanol as organic modifier, buffer pH, buffer concentration, capillary length, column temperature, Triton X-100 and methyl-beta-cyclodextrin was systematically investigated. A central composite design was performed in order to optimize the method. The optimal separation conditions were: capillary, uncoated fused-silica [40 cm (32 cm effective length) x 50 microm I.D.]; background electrolyte, a solution of 145 mM sodium carbonate and 1 mM EDTA brought to pH 10.3-methanol (89:11, v/v); temperature, 15 degrees C; voltage, 12 kV. The method showed good selectivity, repeatability, linearity and sensitivity. Six commercial samples were quantitatively analyzed. The results were compared with those established by the liquid chromatography method from the European Pharmacopoeia.

Doxycycline↗

Analysis of polymyxin B sulfate by capillary zone electrophoresis with cyclodextrin as additive. Method development and validation.

A capillary zone electrophoresis method for analysis of polymyxin B sulfate is described. In this method, triethanolamine (TEA)-phosphate buffer at pH 2.5 was employed to reduce the adsorption of analyte onto the capillary wall. Methyl-beta-cyclodextrin (M-beta-CD) and 2-propanol (IPA) were found to be necessary for selectivity enhancement. In order to optimize the method and to control its robustness, a central composite design was performed with four parameters, i.e. concentration of M-beta-CD, TEA, IPA and buffer pH. The optimal separation conditions were as follows: capillary, 55 cm (50 microm I.D., 47 cm effective length); 130 mM TEA-phosphate buffer (pH 2.5) containing 5 mM M-beta-CD and 5% IPA; 24 kV (51 microA) applied voltage; column temperature, 20 degrees C. Further, linearity and limits of detection quantification were examined. Three commercial samples were analyzed quantitatively.

Cyclodextrins↗

Separation of erythromycin and related substances on base-deactivated reversed-phase silica gel columns.

An official liquid chromatographic method for the analysis of erythromycin and related substances, which is based on a polymer reversed-phase, is described in the European Pharmacopoeia and in the United States Pharmacopeia. The pH of the mobile phase used in this system is 9.0. Recent advanced technology has led to the introduction of a new generation of silica-based reversed-phase column packings, which are claimed to be much more stable towards bases. They are useful for the analysis of basic compounds. Studies to verify the separation of erythromycin and related substances on Hypersil BDS C18, Luna C18(2), Inertsil ODS-2 and Supelcosil ABZ+ have been performed and the results are presented. It is shown that these base-deactivated phases give a better sensitivity and selectivity towards erythromycins than the polymer phase, provided that an adapted mobile phase is used. This is the first liquid chromatographic method described for the separation of erythromycin D from erythromycin A.

Chromatography, High Pressure Liquid↗

Liquid chromatography of polymyxin B sulphate.

A reversed-phase liquid chromatography method for analysis of polymyxin B sulphate is described. The method uses a YMC-Pack Pro, C18, 5 microm, 250x4.6 mm I.D. column maintained at 30 degrees C. The mobile phase comprises acetonitrile-sodium sulphate (0.7%, m/v)-phosphoric acid (6.8%, v/v dilution of 85%, m/m phosphoric acid)-water (22.25:50:5:22.75) at a flow-rate of 1.0 ml/min. Detection was by UV at 215 nm. The method is able to resolve polymyxin B1, the major component, from more than thirty other components present in the complex. Robustness was evaluated by performing a full-factorial design experiment. The method showed good selectivity, repeatability, linearity and sensitivity.

Anti-Bacterial Agents↗

Investigation of unknown related substances in commercial erythromycin samples with liquid chromatography/mass spectrometry.

A selective reversed phase liquid chromatography/mass spectrometry (LC/MS(n)) method is described for the identification of erythromycin impurities and related substances in commercial erythromycin samples. Mass spectral data are acquired on a LCQ ion trap mass spectrometer equipped with an electrospray interface operated in positive ion mode. The LCQ is ideally suited for identification of impurities and related substances because it provides on-line LC/MS(n) capability. Compared with UV detection, this hyphenated LC/MS(n) technique provides as a main advantage efficient identification of novel substances without time-consuming isolation and purification procedures. Using this method four novel related substances were identified in commercial samples.

Animals↗

Analysis of colistin sulfate by capillary zone electrophoresis with cyclodextrins as additive.

A method for the quantitative analysis of colistin sulfate by capillary zone electrophoresis is described. Since colistin components have five free amino groups, they tend to adsorb onto the capillary wall and cause peak tailing. It was found that triethanolamine (TEA)-phosphate buffer at pH 2.5 was useful to reduce such adsorption. Methyl-beta-cyclodextrin (M-beta-CD) and 2-propanol (IPA) were found necessary for selectivity enhancement. In order to optimize the separation parameters and predict the method robustness, a central composite design was performed including three variables, namely concentration of M-beta-CD, TEA, and IPA. The effects of capillary length and applied voltage on separation were also investigated. The optimal conditions established were: 140 mM TEA-phosphate buffer containing 5 mM M-beta-CD and 6% v/v IPA, a capillary with 55 cm total length (50 microm inner diameter, 47 cm from inlet to detection window) and 24 kV applied voltage. The method was found to be robust when the variables were changed in the following range: 4-6 mM M-beta-CD, 5-7% v/v IPA, and 130-150 mM TEA. Further, the linearity, limit of detection (LOD), and limit of quantitation (LOQ), as well as repeatability for both colistin A and B were examined and three commercial samples were quantitatively analyzed.

1-Propanol↗