Coronary aneurysm after bailout stent implantation: diagnosis of a false lumen with intravascular ultrasound.

This case report describes the intravascular ultrasound (IVUS) evaluation of a coronary artery aneurysm, developed in a stented segment within 6 mo after bailout stenting. Analysis of the IVUS images provides in vivo insights in the vessel-remodeling process after mechanical injury. The proximal entrance of the false lumen could be clearly visualized as well as the relationship between the stent struts, neolumen, and vessel wall. The discussion is focused on the options for management of such patients.

Aged↗

One balloon approach for optimized Palmaz-Schatz stent implantation: the MUSCAT trial.

BACKGROUND: After stent deployment, larger balloons are frequently needed to optimize stent expansion according to angiographic and intravascular ultrasound (IVUS) criteria. The objective of this trial was to assess the feasibility and safety of a single-balloon approach for predilation, stent implantation, and optimization with a differential-compliant balloon allowing for focal overexpansion. We also evaluated the achieved degree of stent expansion according to IVUS criteria. METHODS AND RESULTS: Forty-seven consecutive patients with 50 lesions received single or multiple Palmaz-Schatz coronary stents. The final angiographic diameter stenosis was -2.6 +/- 12.6% (reference diameter, 2.89 +/- 0.44 mm), and the residual lumen area stenosis (IVUS) was 13.0 +/- 12.3% (reference area 10.8 +/- 3.0 mm2). This result was achieved in two steps (first angiographic, then IVUS-guided stent optimization). The balloon inflation pressure increased from 13.1 +/- 3.0 bar at step 1 to 16.1 +/- 3.0 bar at step 2, which resulted in a balloon to artery ratio of 0.97 +/- 0.12 and 1.10 +/- 0.15, respectively, at the low-compliant peripheral balloon segments. The more compliant central balloon segments showed a balloon to artery ratio of 1.09 +/- 0.17 and 1.28 +/- 0.17, respectively. The primary success rate for stent deployment was 94%. Acute complications included two type A and one type B dissection without clinical sequelae. CONCLUSIONS: The single-balloon approach for stenting is feasible and safe. The acute result is comparable to that of other studies with IVUS-guided stent optimization, the primary success rate, however, is slightly lower with the presently available catheter.

Adult↗

Coronary plaque morphologic characteristics early and late after heart transplantation: in vivo analysis with intravascular ultrasonography.

To characterize plaque morphologic characteristics of transplant coronary artery disease early and late after cardiac transplantation, 72 patients were studied with intravascular ultrasonography during routine coronary angiography (group 1, 25 patients < or = 2 months after surgery; group 2, 47 patients > or = 12 months after surgery). Both groups had comparable baseline characteristics. Three hundred fifty-one segments were imaged in 127 coronary arteries (4.9 +/- 1.8 segments per patient). By intravascular ultrasonography, relevant intimal thickening (> 0.3 mm) was found in the majority of patients (68% for group 1 and 72% for group 2). Angiography detected abnormal findings in only 16% and 32% for groups 1 and 2, respectively. Mean intimal index was higher in patients late after transplantation (27% +/- 12% vs 17% +/- 12%, respectively; p < 0.01). Maximal and mean plaque thickness were comparable in both groups, whereas a higher mean plaque circumference was found in group 2 (278 +/- 66 degrees vs 211 +/- 75 degrees, respectively; p < 0.002). The lesions were more eccentric in patients early after transplantation (mean eccentricity index 95% +/- 7% vs 77% +/- 15%, respectively; p < 0.0001). Diffuse, concentric intimal thickening was not a common pattern. Maximal plaque thickness correlated with donor age (r = 0.50, p < 0.0001). Coronary lesions were frequent even early after transplantation, with predominantly eccentric plaque morphologic characteristics indicative of preexisting atherosclerosis. Later after transplantation, a more homogeneous plaque distribution was seen, partly with diffuse concentic intimal thickening. Late transplant coronary artery disease appears to be a combination of preexisting native and acquired immune-mediated coronary artery disease.

Adult↗

[Applications and value of intravascular ultrasound imaging in coronary interventions].

Intravascular ultrasound (IVUS) is a twodimensional imaging technique that provides crossections of the coronary artery with a high spatial resolution and therefore became the new gold standard for quantifying complex lesions. The detailed information about vessel and lumen dimensions before and particularly after angioplasty is of high clinical value, because the acute luminal gain is an important predictor of restenosis. At the moment IVUS is the only way of analyzing the plaque composition in vivo. This allows plaque-specific interventional therapy of coronary lesions with balloon or modern alternative angioplasty techniques like directional atherectomy, rotational atherectomy, stenting or a combination of these. IVUS can also quantify the plaque burden in angiographically normal reference segments during balloon angioplasty and stenting. This often leads to the use of larger balloon diameters than those chosen by angiographic measurement of the reference segments. For stenting the prognostic significance of this additional luminal gain could be shown, for other interventional procedures this is currently being investigated in controlled studies.

Angioplasty, Balloon, Coronary↗

Ultrasound guidance of Palmaz-Schatz intracoronary stenting with a combined intravascular ultrasound balloon catheter.

BACKGROUND: Coronary stenting in conjunction with coronary angioplasty is a valuable tool for treatment of severe coronary dissection and is effective in reducing the frequency of restenoses. Evidence is increasing that the lumen gain within the stent is negatively correlated with the rate of subacute closures and restenoses. Since the assessment of radiolucent coronary stents and complex lumen morphologies by angiography is limited, we hypothesized that the use of a balloon catheter with integrated intravascular ultrasound (IVUS) facility for stent deployment and guidance of its expansion could improve the acute lumen gain without relevant procedural prolongation. METHODS AND RESULTS: Deployment of a single Palmaz-Schatz coronary stent with the combined imaging balloon catheter alone was successful in 18 of 20 patients eligible for this study. Corresponding measurements of minimal lumen diameter (MLD) by angiography and IVUS could be performed in 16 patients, revealing a close correlation between the two methods within the reference segments (3.10 +/- 0.38 and 3.08 +/- 0.43 mm, r = .79). Despite an adequate angiographic result in most patients after stent deployment, IVUS showed smaller MLD within the stented segment (2.15 +/- 0.23 mm) compared with angiography (2.63 +/- 0.26 mm, P < .0001) with a poor correlation (r = .27). To achieve IVUS criteria for optimal stent expansion (ratio of 0.9 between IVUS-assessed cross-sectional area of stent and reference segment), an average of three additional balloon inflations with higher pressure and/or a larger balloon diameter were performed without adverse effects in 15 of 16 patients who initially did not fulfill these criteria. This resulted in a significant increase in stent MLD to 2.63 +/- 0.27 mm (IVUS, P < .0001 versus initial MLD) and 2.89 +/- 0.32 mm (angiography, P < .0002 versus initial MLD) and a better correlation between the two methods (r = .60). The IVUS guidance led to a 40 +/- 15% increase of the minimal stent cross-sectional area with an additional time consumption of 21 minutes on average. CONCLUSIONS: This study demonstrates the application of a combined imaging balloon catheter for delivery and ultrasound-guided expansion of Palmaz-Schatz coronary stents. IVUS offered a comprehensive insight into the stented coronary segments, revealing a substantial overestimation of stent dimensions by angiography. IVUS guidance led to a significant improvement of stent expansion. This additional lumen gain, which was not discernible by angiography in most patients, might result in a reduction of subacute stent thromboses as well as restenoses.

Adult↗

Intravascular ultrasound assessment of the balloon-expandable Palmaz-Schatz coronary stent.

BACKGROUND: Coronary stenting is an effective method for the treatment of acute coronary dissection and restenosis. In the comprehensive assessment of restenosis and of the complex interaction between coronary stent and vessel wall, coronary arteriography has significant limitations. Intravascular ultrasound as a high-resolution tomographic imaging method is a promising tool for resolving these limitations. METHODS: A 3.5, 5.0 or 5.5F, 20 MHz multi-element ultrasound catheter was used in 27 patients who had received a Palmaz-Schatz coronary stent for the treatment of symptomatic coronary dissection. Intravascular ultrasound study was performed during routine follow-up arteriography at 3-10 months in all 27 patients and had also been performed in four patients during stent deployment. Four patients with restenosis within the stent were re-investigated 3 months later after repeat angioplasty. RESULTS: Complete analysis of the stented coronary segment could be performed in 34 out of 35 studies (97%); no adverse effects occurred. The three layer appearance of the vessel wall was not discernible in most patients because of a complex and often eccentric lesion surrounding the stent resulting in an asymmetrical arrangement of stent filaments. The beginning and the end of the stent, the central strut, and the overlap of a double stent could be well assessed. Luminal diameters ranged from 1.95 to 4.15 mm and cross-sectional areas from 3.83 to 10.85 mm2. Correlations with quantitative arteriography revealed r-values of 0.58 for diameter and 0.59 for area. A stent-covering layer, indicative of neointima, was clearly visible in all patients during follow-up arteriography with a diameter of 0.10-0.95 mm (mean 0.25 +/- 0.15 mm), which resulted in a reduction of 2-63% in the cross-sectional area of the vessel. This layer did not exceed a thickness of 0.4 mm in asymptomatic patients. CONCLUSIONS: This study demonstrates the safe and feasible application of intravascular ultrasound in patients with stented coronary lesions. Differences between the angiographic and ultrasonic measurements are presumably the result of the limitations of radiography in complex and eccentric lesions. Intracoronary ultrasound provides a unique comprehensive assessment of stent expansion, neointimal proliferation, and restenosis mechanisms. Thus, intravascular ultrasound may also have implications regarding the indication for, and optimal deployment of, intracoronary stents.

Aged↗

Optical coherence tomography.

BACKGROUND: Optical coherence tomography (OCT) is a light-based imaging modality that can be used in biological systems to study tissues in vivo with near-histologic, ultrahigh resolution. The rationale for intravascular application of OCT is its potential for in vivo visualisation of the coronary artery microstructure. METHODS AND RESULTS: The principle is analogous to pulse-echo ultrasound imaging; however, light is used rather than sound to create the image. Low-coherent near-infrared light is emitted by a superluminescent diode and reflected by the microstructures within biological tissues. The echo time delay of reflected light waves is converted into a two-dimensional spatial image. The intensity of the reflected light waves is translated into an intensity map. Experimental studies confirmed the ability of intravascular OCT for plaque characterisation and accurate assessment of vascular structures that are close to the luminal surface. Preliminary clinical experience proved in vivo feasibility of intravascular OCT. A variety of atherosclerotic plaque structures including thin cap fibroatheromas can be visualized in vivo. CONCLUSIONS: Intravascular OCT allows for accurate assessment of vessel structures close to the luminal side. Clinical application is feasible. To date, however, the clinical relevance of OCT findings in coronary arteries is unclear and further validation of OCT imaging is mandatory.

Coronary Artery Disease↗