E R McVeigh

Publications and source records attributed to E R McVeigh.

At least 19 recordsLinked to original sources

Electromechanics of paced left ventricle simulated by straightforward mathematical model: comparison with experiments.

Intraventricular synchrony of cardiac activation is important for efficient pump function. Ventricular pacing restores the beating frequency but induces more asynchronous depolarization and more inhomogeneous contraction than in the normal heart. We investigated whether the increased inhomogeneity in the left ventricle can be described by a relatively simple mathematical model of cardiac electromechanics, containing normal mechanical and impulse conduction properties. Simulations of a normal heartbeat and of pacing at the right ventricular apex (RVA) were performed. All properties in the two simulations were equal, except for the depolarization sequence. Simulation results of RVA pacing on local depolarization time and systolic midwall circumferential strain were compared with those measured in dogs, using an epicardial sock electrode and MRI tagging, respectively. We used the same methods for data processing for simulation and experiment. Model and experiment agreed in the following aspects. 1) Ventricular pacing decreased systolic pressure and ejection fraction relative to natural sinus rhythm. 2) Shortening during ejection and stroke work declined in early depolarized regions and increased in late depolarized regions. 3) The relation between epicardial depolarization time and systolic midwall circumferential strain was linear and similar for the simulation (slope = -3.80 +/- 0.28 s(-1), R2 = 0.87) and the experiments [slopes for 3 animals -2.62 +/- 0.43 s(-1) (R2 = 0.59), -2.97 +/- 0.38 s(-1) (R2 = 0.69), and -4.44 +/- 0.51 s(-1) (R2 = 0.76)]. We conclude that our model of electromechanics is suitable to simulate ventricular pacing and that the apparently complex events observed during pacing are caused by well-known basic physiological processes.

Algorithms↗

S5FP: spectrally selective suppression with steady state free precession.

A method is presented that employs the inherent spectral selectivity of the Steady-State Free Precession (SSFP) pulse sequence to provide a spectral band of suppression. At TE = TR/2, SSFP partitions the magnetization into two phase-opposed spectral components. Z-storing one of these components simultaneously further excites the other, which is then suppressed by gradient crushing and RF spoiling. The Spectrally Selective Suppression with SSFP (S(5)FP) method is shown to provide significant attenuation of fat signals, while the water signals are essentially unaffected and provide the normal SSFP contrast. Fat suppression is achieved with relatively little temporal overhead (less than 10% reduction in temporal resolution). S(5)FP was validated using simulations, phantoms, and human studies.

Adipose Tissue↗

Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE.

Parallel imaging applied to first-pass, contrast-enhanced cardiac MR can yield greater spatial coverage for a fixed temporal resolution. The method combines rate R=2 acceleration using TSENSE with shot-to-shot interleaving of two slices. The square root R SNR loss is largely compensated for by a longer effective repetition time (TR) and increased flip angle associated with slice interleaving. In this manner, increased spatial coverage is achieved while comparable or better image quality is maintained. Single-heartbeat temporal resolution was accomplished with spatial coverage of eight slices at heart rates up to 71 bpm, six slices up to 95 bpm, and four slices up to 143 bpm. Experiments in normal subjects (N=6) were performed to assess signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values.

Artifacts↗

Myocardial wall tagging with undersampled projection reconstruction.

Azimuthally undersampled projection reconstruction (PR) acquisition is investigated for use in myocardial wall tagging with MR using grid tags to provide increased temporal and spatial resolution. PR can provide the high-resolution images required for tagging with very few projections, at the expense of artifact. Insight is provided into the PR undersampling artifact, in the context of measuring myocardial motion with tags. For Fourier transform imaging, at least 112 phase-encodings must be collected to image tagging grids spaced 7 pixels apart. PR requires about 80 projections, a 1.4-fold reduction in scan time. Magn Reson Med 45:562-567, 2001. Published 2001 Wiley-Liss, Inc.

Artifacts↗

Adaptive sensitivity encoding incorporating temporal filtering (TSENSE).

A number of different methods have been demonstrated which increase the speed of MR acquisition by decreasing the number of sequential phase encodes. The UNFOLD technique is based on time interleaving of k-space lines in sequential images and exploits the property that the outer portion of the field-of-view is relatively static. The differences in spatial sensitivity of multiple receiver coils may be exploited using SENSE or SMASH techniques to eliminate the aliased component that results from undersampling k-space. In this article, an adaptive method of sensitivity encoding is presented which incorporates both spatial and temporal filtering. Temporal filtering and spatial encoding may be combined by acquiring phase encodes in an interleaved manner. In this way the aliased components are alternating phase. The SENSE formulation is not altered by the phase of the alias artifact; however, for imperfect estimates of coil sensitivities the residual artifact will have alternating phase using this approach. This is the essence of combining temporal filtering (UNFOLD) with spatial sensitivity encoding (SENSE). Any residual artifact will be temporally frequency-shifted to the band edge and thus may be further suppressed by temporal low-pass filtering. By combining both temporal and spatial filtering a high degree of alias artifact rejection may be achieved with less stringent requirements on accuracy of coil sensitivity estimates and temporal low-pass filter selectivity than would be required using each method individually. Experimental results that demonstrate the adaptive spatiotemporal filtering method (adaptive TSENSE) with acceleration factor R = 2, for real-time nonbreath-held cardiac MR imaging during exercise induced stress are presented.

Algorithms↗

Techniques for fast stereoscopic MRI.

Stereoscopic MRI can impart 3D perception with only two image acquisitions. This economy over standard multiplanar 3D volume renderings allows faster frame rates, which are needed for real-time imaging applications. Real-time 3D perception may enhance the appreciation of complex anatomical structures, and may improve hand-eye coordination while manipulating a medical device during an image-guided interventional procedure. To this goal, a system is being developed to acquire and display stereoscopic MR images in real-time. A clinically used, fast gradient-recalled echo-train sequence has been modified to produce stereo image pairs. Features have been added for depth cueing, view sharing, and bulk signal suppression. A workstation was attached to a clinical MR scanner for fast data extraction, image reconstruction and stereoscopic image display.

Humans↗

Ghost artifact cancellation using phased array processing.

In this article, a method for phased array combining is formulated which may be used to cancel ghosts caused by a variety of distortion mechanisms, including space variant distortions such as local flow or off-resonance. This method is based on a constrained optimization, which optimizes SNR subject to the constraint of nulling ghost artifacts at known locations. The resultant technique is similar to the method known as sensitivity encoding (SENSE) used for accelerated imaging; however, in this formulation it is applied to full field-of-view (FOV) images. The method is applied to multishot EPI with noninterleaved phase encode acquisition. A number of benefits, as compared to the conventional interleaved approach, are reduced distortion due to off-resonance, in-plane flow, and EPI delay misalignment, as well as eliminating the need for echo-shifting. Experimental results demonstrate the cancellation for both phantom as well as cardiac imaging examples.

Artifacts↗

A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography.

A comparison between the prospective and retrospective respiratory navigator gating in MR coronary angiography was performed with eight normal subjects. A three-dimensional (3D) ECG-gated fast gradient echo pulse sequence was used for image data acquisition. The results show that the MR coronary angiography obtained using retrospective gating retains a considerable amount of motion artifacts. In this study, the images acquired using prospective navigator gating demonstrated significantly reduced motion artifacts (p = 0.009), improved vessel visibility (p = 0.021) with reduced imaging time (p = 0.013) compared to the images obtained using retrospective navigator gating.

Adult↗

Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging.

BACKGROUND: The purpose of this study was to describe a system and method for creating, visualizing, and monitoring cardiac radiofrequency ablation (RFA) therapy during magnetic resonance imaging (MRI). METHODS AND RESULTS: RFA was performed in the right ventricular apex of 6 healthy mongrel dogs with a custom 7F nonmagnetic ablation catheter (4-mm electrode) in a newly developed real-time interactive cardiac MRI system. Catheters were positioned to intracardiac targets by use of an MRI fluoroscopy sequence, and ablated tissue was imaged with T2-weighted fast spin-echo and contrast-enhanced T1-weighted gradient-echo sequences. Lesion size by MRI was determined and compared with measurements at gross and histopathological examination. Ablated areas of myocardium appeared as hyperintense regions directly adjacent to the catheter tip and could be detected 2 minutes after RF delivery. Lesions reached maximum size approximately 5 minutes after ablation, whereas lesion signal intensity increased linearly with time but then reached a plateau at 12.2+/-2.1 minutes. Lesion size by MR correlated well with actual postmortem lesion size and histological necrosis area (55.4+/-7.2 versus 49.7+/-5.9 mm(2), r=0.958, P<0.05). CONCLUSIONS: RFA can be performed in vivo in a new real-time interactive cardiac MRI system. The spatial and temporal extent of cardiac lesions can be visualized and monitored by T2- and T1-weighted imaging, and MRI lesion size agrees well with actual postmortem lesion size. MRI-guided RFA may be a useful approach to help facilitate anatomic lesion placement and to provide insight into the biophysical effects of new ablation techniques and technologies.

Animals↗

Predictors of systolic augmentation from left ventricular preexcitation in patients with dilated cardiomyopathy and intraventricular conduction delay.

BACKGROUND: VDD pacing can enhance systolic function in patients with dilated cardiomyopathy and discoordinate contraction; however, identification of patients likely to benefit is unclear. We tested predictors of systolic responsiveness on the basis of global parameters as well as directly assessed mechanical dyssynchrony. METHODS AND RESULTS: Twenty-two DCM patients with conduction delay were studied by cardiac catheterization with a dual-sensor micromanometer to measure LV and aortic pressures during sinus rhythm and LV free-wall pacing. Pacing enhanced isovolumetric (dP/dt(max)) and ejection-phase (pulse pressure, PP) systolic function by 35+/-21% and 16.4+/-11%, respectively, and these changes correlated directly (r=0.7, P=0.001). %DeltadP/dt(max) was weakly predicted by baseline QRS (r=0.6, P<0.02), more strongly by baseline dP/dt(max) (r=0.7, P=0.001), and best by bidiscriminate analysis combining baseline dP/dt(max) < or =700 mm Hg/s and QRS > or =155 ms to predict %DeltadP/dt(max) > or =25% and %DeltaPP > or =10% (P<0.0005, chi(2)), with no false-positives. Benefit could not be predicted by %DeltaQRS. To test whether basal mechanical dyssynchrony predicted responsiveness to LV pacing, circumferential strains were determined at approximately 80 sites throughout the LV by tagged MRI in 8 DCM patients and 7 additional control subjects. Strain variance at time of maximal shortening indexed dyssynchrony, averaging 28.0+/-7.1% in normal subjects versus 201.4+/-84.3% in DCM patients (P=0.001). Mechanical dyssynchrony also correlated directly with %DeltadP/dt(max) (r=0.85, P=0.008). Conclusions-These results show that although mechanical dyssynchrony is a key predictor for pacing efficacy in DCM patients with conduction delay, combining information about QRS and basal dP/dt(max) provides an excellent tool to identify maximal responders.

Adult↗

Microvascular obstruction and left ventricular remodeling early after acute myocardial infarction.

BACKGROUND: The presence of microvascular obstruction (MO) within infarcted regions may adversely influence left ventricular (LV) remodeling after acute myocardial infarction. This study examined whether the extent of MO directly alters the mechanical properties of the infarcted myocardium. METHODS AND RESULTS: Seventeen dogs underwent 90 minutes of balloon occlusion of the left anterior descending coronary artery, followed by reperfusion. Gadolinium-enhanced perfusion MRI and 3D-tagging were performed 4 to 6 and 48 hours (8 animals) and 10 days (9 animals) after reperfusion. Early increase in LV end-diastolic volume (from 42+/-9 to 54+/-14 mL, P<0.05) between 4 to 6 and 48 hours after reperfusion was predicted by both extent of MO (r=0.89, P<0.01) and infarct size (r=0.83, P<0.01), defined as MRI hypoenhanced and hyperenhanced regions, respectively. Multivariate analysis demonstrated that extent of MO had better and independent value to predict LV volume than overall infarct size. A strong inverse relationship existed between magnitude of first principal strain (r=-0.80, P<0.001) and relative extent of MO within infarcted myocardium. Also, infarcted myocardium involved by extensive areas of MO demonstrated reductions of circumferential (r=-0.61, P<0.01) and longitudinal (r=-0.53, P<0. 05) stretching. Furthermore, significant reductions of radial thickening (9+/-6% versus 14+/-3%, P<0.01) occurred in noninfarcted regions adjacent to infarcts that had increased (>35%) amounts of MO. CONCLUSIONS: In the early healing phase of acute myocardial infarction, the extent of MO in infarcted tissue relates to reduced local myocardial deformation and dysfunction of noninfarcted adjacent myocardium. Such strain alterations might explain the increased remodeling observed in patients with large regions of MO.

Animals↗

Fast determination of regional myocardial strain fields from tagged cardiac images using harmonic phase MRI.

BACKGROUND: Tagged MRI of the heart is difficult to implement clinically because of the lack of fast analytical techniques. We investigated the accuracy of harmonic phase (HARP) imaging for rapid quantification of myocardial strains and for detailed analysis of left ventricular (LV) function during dobutamine stimulation. METHODS AND RESULTS: Tagged MRI was performed in 10 volunteers at rest and during 5 to 20 microg(-1). kg(-1). min(-1) dobutamine and in 9 postinfarct patients at rest. We compared 2D myocardial strains (circumferential shortening, Ecc; maximal shortening, E(2); and E(2), direction) as assessed by a conventional technique and by HARP. Full quantitative analysis of the data was 10 times faster with HARP. For pooled data, the regression coefficient was r=0.93 for each strain (P<0.001). In volunteers, Ecc and E(2) were greater in the free wall than in the septum (P<0.01), but recruitable myocardial strain at peak dobutamine was greater in the LV septum (P<0.01). E(2) orientation shifted away from the circumferential direction at peak dobutamine (P<0.01). HARP accurately detected subtle changes in myocardial strain fields under increasing doses of dobutamine. In patients, HARP-determined Ecc and E(2) values were dramatically reduced in the asynergic segments as compared with remote (P<0.001), and E(2) direction shifted away from the circumferential direction (P<0.001). CONCLUSIONS: HARP MRI provides fast, accurate assessment of myocardial strains from tagged MR images in normal subjects and in patients with coronary artery disease with wall motion abnormalities. HARP correctly indexes dobutamine-induced changes in strains and has the potential for on-line quantitative monitoring of LV function during stress testing.

Adult↗

Low-latency temporal filter design for real-time MRI using UNFOLD.

To improve real-time control of interventional procedures such as guidance of catheters, monitoring of ablation therapy, or control of dosage during drug delivery, the image acquisition and reconstruction must be high speed and have low latency (small time delay) in processing. A number of different methods have been demonstrated which increase the speed of MR acquisition by decreasing the number of sequential phase-encodes. A design and implementation of the UNFOLD method which achieves the desired low latency with a recursive temporal filter is presented. The recursive filter design is characterized for this application and compared with more commonly used moving average filters. Experimental results demonstrate low-latency UNFOLD for two applications: 1) high-speed, real-time imaging of the heart to be used in conjunction with cardiac interventional procedures; and 2) the injection of drugs into muscle tissue with contrast enhancement, i.e., monitoring needle insertion and injection of a drug with contrast enhancement properties. Proof-of-concept was demonstrated by injecting a contrast agent. In both applications the UNFOLD technique was used to double the frame rate.

Animals↗

Left ventricular motion reconstruction from planar tagged MR images: a comparison.

Through recent development of MR techniques, it is now possible to assess regional myocardial wall function in a non-invasive way. Using MR tagging, space is marked with planes which deform with the tissue, providing markers for tracking the local motion of the myocardium. Numerous methods to reconstruct the three-dimensional displacement field have been developed. The aim of this article is to provide a framework to quantitatively compare the performance of four methods the authors have developed. Five sets of experiments are described, and their results are reported. Instructions are also provided to perform similar tests on any method using the same data. The experiments show that some characteristic properties of the methods, such as sensitivity to noise or spatial resolution, can be quantitatively classified. Cross-comparison of performances show what range values for these properties can be considered acceptable.

Animals↗

Four-dimensional B-spline based motion analysis of tagged MR images: introduction and in vivo validation.

In MRI tagging, magnetic tags-spatially encoded magnetic saturation planes-are created within tissues acting as temporary markers. Their deformation pattern provides useful qualitative and quantitative information about the functional properties of underlying tissue and allows non-invasive analysis of mechanical function. The measured displacement at a given tag point contains only unidirectional information; in order to track the full 3D motion, these data have to be combined with information from other orthogonal tag sets over all time frames. Here, we provide a method to describe the motion of the heart using a four-dimensional tensor product of B-splines. In vivo validation of this tracking algorithm is performed using different tagging sets on the same heart. Using the validation results, the appropriate control point density was determined for normal cardiac motion tracking. Since our motion fields are parametric and based on an image plane based Cartesian coordinate system, trajectories or other derived values (velocity, acceleration, strains ...) can be calculated for any desired point within the volume spanned by the control points. This method does not rely on specific chamber geometry, so the motion of any tagged structure can be tracked. Examples of displacement and strain analysis for both ventricles are also presented.

Algorithms↗

Quantitative tagged magnetic resonance imaging of the normal human left ventricle.

Magnetic resonance imaging with tissue tagging is a noninvasive technique for measuring three-dimensional motion and deformation in the human heart. Tags are regions of tissue whose longitudinal magnetization has been altered before imaging so that they appear dark in subsequent magnetic resonance images. They then move with the underlying tissue and serve as easily identifiable landmarks within the heart for the detailed detection of motion. Many different motion and strain parameters can be determined from tagged magnetic resonance imaging. Strain components that are based on a high density of tag data, such as circumferential and longitudinal shortening, or parameters that are combinations of multiple strain components, have highest measurement precision and tightest normal ranges. The pattern of three-dimensional motion and strain in the heart is important clinically, because it reflects the basic mechanical function of the myocardium at both local and global levels. Localized abnormalities can be detected and quantified if the pattern of deformation in a given heart is compared to the normal range for that region, because normal motion and strain in the left ventricle is spatially heterogeneous. Contraction strains typically are greatest in the anterior and lateral walls and increase toward the apex. The direction of greatest contraction lies along a counter clockwise helix from base to apex (viewed from the base) and approximates the epicardial muscle fiber direction. This fiber geometry also results in long-axis torsion during systole. Ejection is accomplished primarily by radially inward motion of the endocardium and by descent of the base toward the apex during systole.

Female↗

Imaging heart motion using harmonic phase MRI.

This paper describes a new image processing technique for rapid analysis and visualization of tagged cardiac magnetic resonance (MR) images. The method is based on the use of isolated spectral peaks in spatial modulation of magnetization (SPAMM)-tagged magnetic resonance images. We call the calculated angle of the complex image corresponding to one of these peaks a harmonic phase (HARP) image and show that HARP images can be used to synthesize conventional tag lines, reconstruct displacement fields for small motions, and calculate two-dimensional (2-D) strain. The performance of this new approach is demonstrated using both real and simulated tagged MR images. Potential for use of HARP images in fast imaging techniques and three-dimensional (3-D) analyses are discussed.

Algorithms↗