Search PubMed⌕ Search

Biomedical subjects

E R Bates

Publications and source records attributed to E R Bates.

At least 109 records · Page 6Linked to original sources

A randomized, placebo-controlled trial of intravenous recombinant tissue-type plasminogen activator and emergency coronary angioplasty in patients with acute myocardial infarction.

To determine the role of tissue-type plasminogen activator (t-PA) and immediate percutaneous transluminal coronary angioplasty (PTCA) in treating patients with evolving transmural myocardial infarction, 50 patients received t-PA (1.25 mg/kg iv over 3 hrs) or placebo according to 3:1 double-blind randomization 3.8 +/- 1.1 hr after onset of symptoms. At emergency coronary arteriography, patency of the infarct-related vessel was demonstrated in 32 of 38 (84%) patients receiving t-PA vs two of 12 (17%) receiving placebo (p less than .001). Of the 32 patients with recanalization after t-PA, 28 had a residual stenosis of at least 50% and underwent randomization a second time to immediate (n = 15) or no PTCA (n = 13). Immediate PTCA of the infarct-related vessel was successful in all 15 patients, with reduction of the residual diameter stenosis from 80.8 +/- 8.2% to 32.5 +/- 15.6% (p less than .001). The incidence of postinfarction angina (greater than or equal to 20 min of chest discomfort and reversible electrocardiographic changes) and reinfarction (documented by recurrent creatine kinase isoenzyme elevation) was reduced in the patients receiving t-PA and PTCA (2/15) compared with that in patients receiving t-PA alone (7/13; p = .006). At 1 week there was no difference in patency of the infarct-related vessel (12/15 t-PA and PTCA vs 9/13 t-PA only) or in global ventricular functional change between the two groups (0.5 +/- 10.4 SD/chord for t-PA and PTCA vs -2.1 +/- 8.2 SD/chord for t-PA only).(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon↗

Effect of angioplasty-induced endothelial denudation compared with medial injury on regional coronary blood flow.

To determine the effect of angioplasty-induced arterial injury on regional coronary blood flow, resting and postocclusion reactive hyperemic flows were measured in the left anterior descending (LAD) and circumflex (LCx) coronary arteries of 32 dogs after one of four interventions in the LAD with a balloon angioplasty catheter: group A, no injury; group B, endothelial denudation; group C, medial injury; group D, pretreatment with 325 mg of aspirin 2 hr before medial injury. Resting flows did not change in any group. In group C, hyperemic flow decreased in both the LAD and LCx by 15% to 20% (p less than .001) over 30 to 90 min, suggesting that a circulating substance changed coronary resistance. Histologic and ultrastructural studies of the LADs demonstrated an intact endothelial cell layer in group A, endothelial disruption with a few adherent platelets in group B, medial injury with a dense layer of adherent platelets in group C, and medial injury with a few adherent platelets in group D. Thus endothelial denudation results in relatively mild platelet deposition and no change in resting or hyperemic coronary blood flow. In contrast, medial injury results in relatively marked platelet deposition and a significant decrease in hyperemic flow, both of which are prevented by platelet inhibition with aspirin.

Angioplasty, Balloon↗

Hormonal responses to cardiac tamponade: inhibition of release of atrial natriuretic factor despite elevation of atrial pressures.

Atrial distension, rather than change in intra-atrial pressure, has been suggested as a principal mediator of release of atrial natriuretic factor (ANF). During cardiac tamponade, atrial pressures rise whereas transmural pressures and atrial stretch may not be affected. The roles of atrial pressure and atrial distension were investigated in six open-chest dogs subjected to cardiac tamponade and rapid volume expansion as disparate means of affecting intra-atrial pressures and atrial stretch. Hemodynamic measurements, immunoreactive ANF (ir-ANF), plasma renin activity, antidiuretic hormone, epinephrine, and norepinephrine were monitored before, during, and after three interventions: (1) tamponade, (2) rapid volume loading followed by tamponade, and (3) volume loading during tamponade. Volume expansion increased right atrial pressure and caused a significant rise in ir-ANF. Elevations of right atrial pressure caused by tamponade were comparable to those induced by volume infusion, but an increase in ir-ANF was not elicited during tamponade, and the ir-ANF response to volume loading was abolished when performed during tamponade. The relation between the change in ANF concentration and change in right atrial pressure were highly significant in the absence of tamponade, when atrial stretch was freely responsive to volume expansion (r = .73, p less than .0001), but not when stretch was inhibited (r = -.16, p = NS). These observations underscore the importance of considering the modulating effects of atrial compliance, transmural pressure, and atrial stretch on the relation between atrial pressures and ANF release.

Animals↗

Value of percutaneous transluminal coronary angioplasty after unsuccessful intravenous streptokinase therapy in acute myocardial infarction.

The effect of sequential high-dose intravenous streptokinase (SK) (1.5 million units) followed by emergency percutaneous transluminal coronary angioplasty (PTCA) on preserving left ventricular function was assessed prospectively in 34 patients with acute myocardial infarction (AMI). Intravenous SK therapy was initiated 2.6 +/- 1.3 hours (mean +/- standard deviation) after the onset of chest pain. Urgent coronary angiography showed persistent total occlusion in 13 patients, significant diameter stenosis (70 to 99%) in 18 patients and a widely patent artery (less than 50% stenosis) in 3 patients. Emergency PTCA was performed in 29 patients 5.0 +/- 2.1 hours after symptom onset. Successful recanalization was achieved in 33 of the 34 patients (97%) treated with sequential therapy. Repeat contrast ventriculograms recorded 7 to 10 days after intervention in 23 patients showed that the left ventricular ejection fraction increased from 53 +/- 12% to 59 +/- 13% (area-length method, p less than 0.002). Regional wall motion of the infarcted segments improved from -2.7 +/- 1.1 to -1.5 +/- 1.7 SD/chord (centerline method, p less than 0.003). In the subgroup of patients with an occluded artery on initial angiography (group A, n = 10), both global left ventricular ejection fraction (49 +/- 12% vs 59 +/- 12%, p less than 0.002) and regional wall motion (-3.2 +/- 1.0 vs -1.9 +/- 1.7 SD/chord, p less than 0.002) improved significantly. In contrast, no significant improvement was seen in patients with a patent artery on initial angiography (n = 13). Thus, sequential intravenous SK and emergency PTCA is efficacious in achieving coronary reperfusion and in improving both global and regional left ventricular function.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Intermittent, ambulatory dobutamine infusions in patients with severe congestive heart failure.

Thirteen ambulatory patients with severe congestive heart failure were treated with weekly, outpatient 48-hour infusions of dobutamine. All 13 patients had at least a 25% increase in cardiac output during initial dobutamine titration, with a corresponding improvement in systemic vascular resistance. Improvement in functional class was achieved in only seven patients. Additionally, only three patients survived the 26-week study period. Although no change in ventricular ectopy was noted during the initial dobutamine infusions, six patients experienced sudden death; three other patients died of progressive heart failure and one died from pulmonary embolism. These data suggest that chronic intermittent ambulatory dobutamine infusions are only partly successful in improving symptoms and probably do not prolong survival in patients with severe congestive heart failure. Administration of this form of therapy on a clinical basis should be undertaken cautiously until safety and efficacy are demonstrated in prospective, controlled trials.

Aged↗

Comparative study of coronary flow reserve, coronary anatomy and results of radionuclide exercise tests in patients with coronary artery disease.

A comparative assessment of regional coronary flow reserve, quantitative percent diameter coronary stenosis and exercise-induced perfusion and wall motion abnormalities was performed in 39 patients with coronary artery disease. Coronary flow reserve was determined by a digital angiographic technique utilizing contrast medium as the hyperemic agent. Percent diameter stenosis was calculated by an automated quantification program applied to orthogonal cineangiograms. Thallium-201 scintigraphy and radionuclide ventriculography were used to assess regional perfusion and wall motion abnormalities, respectively, at rest and during exercise. In Group A, 19 patients without transmural infarction or collateral vessels, coronary flow reserve was inversely related to percent diameter stenosis (r = -0.61, p less than 0.0001), and scintigraphic abnormalities occurred only in vascular distributions with a coronary flow reserve of less than 2.00. There was a strong relation among abnormal regional exercise results, stenoses greater than 50% and reactive hyperemia of less than 2.00. Patients with multivessel disease, however, often had normal exercise scintigrams in regions associated with greater than 50% stenosis and low coronary flow reserve when other regions had a lower coronary flow reserve or higher grade stenosis, or both. In Group B, 20 patients with angiographically visible collateral vessels, 12 of whom had prior myocardial infarction, coronary flow reserve correlated less well with percent diameter stenosis than in Group A (r = -0.47, p less than 0.004). As in Group A patients, there was a significant relation between abnormal exercise test results and stenoses greater than 50%. However, reactive hyperemia values were generally lower than in Group A, and positive exercise stress results were strongly correlated only with highly impaired flow reserves of 1.3 or less. In Group B patients, the coronary flow reserve of vessels with less than 50% stenosis was significantly lower than that of similar vessels in Group A patients (2.40 +/- 0.79 versus 1.56 +/- 0.43; p less than 0.0002). It is concluded that: there is a general relation between quantitative percent diameter stenosis and reactive hyperemia that is not of sufficient precision to allow accurate prediction of coronary flow reserve in individual cases; exercise scintigraphic abnormalities are usually associated with low coronary flow reserve, and the relation between these two functional tests is stronger than the relation between exercise test results and quantitative percent diameter stenosis.(ABSTRACT TRUNCATED AT 400 WORDS)

Aged↗

The relationship between plasma levels of immunoreactive atrial natriuretic hormone and hemodynamic function in man.

To evaluate the relationship between plasma levels of immunoreactive atrial natriuretic hormone (IR-ANH) and different hemodynamic parameters in man, we studied 34 patients undergoing right heart catheterization. Plasma levels of IR-ANH in blood samples withdrawn from the femoral vein (n = 28), right ventricle (n = 27), and left ventricle (n = 17) were determined by radioimmunoassay. Right atrial pressure, pulmonary arterial wedge pressure, heart rate, and mean arterial pressure were found to be independent and significant predictors of IR-ANH plasma levels. The closest correlations were between right atrial pressure and either right ventricular IR-ANH levels (r = .78, p greater than .001) or femoral vein IR-ANH levels (r = .52, p less than .006). Five patients with isolated left ventricular failure had elevated IR-ANH levels out of proportion to their right atrial pressure levels. Pulmonary arterial wedge pressure also correlated with right ventricular IR-ANH levels (r = .46, p less than .002) and with femoral vein IR-ANH levels (r = .58, p less than .002). A single patient with isolated right heart failure had markedly elevated IR-ANH levels despite normal pulmonary arterial wedge pressure. Right ventricular levels were twice femoral vein levels and were closely correlated (181 +/- 40 vs 90 +/- 20 pmol/liter; r = .90, p less than .001). Right ventricular and left ventricular levels were almost identical (155 +/- 46 vs 146 +/- 43 pmol/liter; r = .99, p less than .001). Patients with volume overload states had elevated IR-ANH levels.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterization.

Assessment of the functional significance of anatomically defined coronary stenoses has been hampered by the lack of clinically applicable techniques of measuring coronary blood flow or flow ratios. A digital angiographic technique is reported that allows rapid analysis of relative regional coronary blood flow during routine cardiac catheterization. This technique was validated in dogs by comparing digital flow ratio estimates with electromagnetic-flow (EMF) ratio measurements. Fourteen open-chest dogs had EMF probes placed on the proximal left anterior descending artery before selective coronary angiography. Electrocardiographically gated images were acquired directly by a digital radiographic system during both baseline blood flow and either contrast or papaverine-induced hyperemia. Dual-parameter functional images were generated using color and intensity coding to represent contrast arrival time and contrast density, respectively. For analysis, myocardial areas of interest were created over the distal perfusion bed of the left anterior descending coronary artery. Mean contrast density/appearance time (CD/AT) values were computer calculated as the mean density divided by the mean arrival time for each. Coronary flow reserve was determined as the ratio of the CD/AT value for a hyperemic image divided by the CD/AT value for the corresponding baseline image. CD/AT ratios correlated well (r = 0.92) with actual EMF ratios (CD/AT Ratio = 0.90 EMF Ratio +0.12, n = 48 ratios). Reproducibility was +/- 13%. Interobserver (r = 0.99) and intraobserver (r = 0.98) variability was excellent. Thus, rapid, accurate and reproducible estimates of relative regional coronary blood flow are possible using digital radiography.

Animals↗

Digital subtraction angiographic assessment of the coronary arteries and coronary flow reserve.

Although intravenous digital subtraction angiography was originally intended as a means of performing less invasive peripheral angiography, this less invasive approach has not proven feasible for coronary artery studies. Digital imaging has, however, proven helpful for the immediate replay, enhancement and quantification of coronary arteriography and enables the performance of regional blood flow (coronary flow reserve) analysis. Flow analysis is clinically helpful in determining the hemodynamic significance of individual coronary stenoses, which cannot always be assessed even using quantitative stenosis measurements. One method of assessing flow reserve by digital means uses parametric images to display the timing (color coded) and density (intensity coded) of the contrast bolus as it transverses the regional myocardial circulation. Analysis of baseline and hyperemic condition parametric images provides quantitative regional flow reserve information.

Angiography↗

Cardiac applications of digital subtraction angiography.

Recent developments in digital computer technology have enabled direct digital acquisition of radiographic images at spatial and temporal resolutions similar to that of cineradiography. Initially intended as a means of performing peripheral angiography, digital subtraction angiography has been increasingly applied to cardiac catheterization procedures. Advantages of cardiac digital subtraction angiography include the capabilities to: immediately replay, magnify and enhance angiographic studies during coronary artery interventions, perform left ventriculography with peripheral contrast injections and direct left ventriculography with substantially reduced contrast doses, perform bypass graft visualization using aortic root contrast injection, assess relative regional coronary blood flow and facilitate the quantification of ventriculographic and coronary stenosis parameters. Clinical comparisons of standard cineradiographic and digital angiographic studies have demonstrated very similar results.

Angiocardiography↗

Abnormal coronary flow reserve and abnormal radionuclide exercise test results in patients with normal coronary angiograms.

Coronary flow reserve, exercise thallium-201 scintigraphy and exercise radionuclide ventriculography were compared in 18 patients with chest pain and angiographically normal coronary arteries. Regional exercise thallium-201 perfusion was abnormal in three patients, regional exercise wall motion was abnormal in three other patients and results of both tests were abnormal in one additional patient. Left ventricular ejection fraction responses were abnormal in five of these seven patients. The coronary flow reserve of arterial distributions with abnormal perfusion or regional dysfunction was significantly lower than that of distributions associated with normal radionuclide results (1.42 +/- 0.23 versus 2.58 +/- 0.83, p less than 0.001). All patients with abnormal scintigraphic results had low coronary flow reserve (less than 1.95) in at least one distribution. Perfusion abnormalities appeared to be more localized in the arterial distributions with the lowest flow reserve. Only two patients had low flow reserve (less than 1.95) with normal scintigraphic results; both were hypertensive. These data suggest that abnormal exercise scintigraphic findings in patients with angiographically normal coronary arteries and chest pain are indicative of true blood flow or perfusion abnormalities.

Adult↗

Coronary artery steal: demonstration by digital coronary radiography.

The authors, using a new digital coronary radiographic technique, report the demonstration of contrast-material-induced coronary artery steal. Attempts to measure myocardial blood flow using arteriographic techniques in the setting of complex coronary anatomy can be complicated by heterogeneous flow patterns.

Adult↗

Comparative long-term effects of coronary artery bypass graft surgery and percutaneous transluminal coronary angioplasty on regional coronary flow reserve.

To evaluate the relative long-term improvement in coronary artery hemodynamics after revascularization by coronary artery bypass graft surgery (CABG) or percutaneous transluminal coronary angioplasty (PTCA), regional coronary flow reserve (CFR) was measured, by digital computer analysis of 35 mm cine film, in 50 men undergoing cardiac catheterization. CFR (mean +/- SEM) in 12 atherosclerotic arteries before revascularization was 1.02 +/- 0.05. Mean CFR in 29 normal arteries of men with normal coronary arteriograms was significantly higher (2.59 +/- 0.11) than that in 16 atherosclerotic arteries of patients revascularized by CABG (2.02 +/- 0.17, p less than .01) or in 14 atherosclerotic arteries of those revascularized by PTCA (1.97 +/- 0.12, p less than .01). No difference in CFR between the CABG and PTCA groups was found and variables known to influence CFR were similar between groups. Equivalent and significant long-term improvement in coronary artery hemodynamics is provided by CABG or PTCA. We postulate that the difference in CFR in the men with normal arteries and those who underwent revascularization was related to the effects of the general atherosclerotic process, which remain despite successful treatment by these techniques.

Angiography↗

Quantitative assessment of global and regional left ventricular function with low-contrast dose digital subtraction ventriculography.

Few studies have compared the use of low-contrast dose digital subtraction ventriculography with conventional ventriculography for quantitative assessment of both global and regional left ventricular function. Accordingly, 34 patients underwent conventional ventriculography using 36 ml of ionic contrast material and digital ventriculography (mask-mode) using 10 ml of contrast diluted in 10 ml of saline and injected over two seconds. Data from two patients were excluded because of ectopy during cineventriculography and from one because of ectopy during both studies. End-diastolic and end-systolic volumes were calculated from both studies by an area-length method and used to calculate ejection fractions. Regional wall motion was quantitated by the centerline method. Results of linear regression analysis demonstrated high correlations for all parameters (end-diastolic volume, r = 0.85; end-systolic volume, r = 0.93; ejection fraction, r = 0.92; quantitative regional wall motion, r = 0.90). Thus, low-contrast dose digital subtraction ventriculography provides an accurate assessment of both global and regional ventricular function and minimizes the required dose and inherent risks of contrast media.

Adult↗