Search PubMed⌕ Search

Biomedical subjects

E Picano

Publications and source records attributed to E Picano.

At least 55 records · Page 3Linked to original sources

The comparable diagnostic accuracies of dobutamine-stress and dipyridamole-stress echocardiographies: a meta-analysis.

BACKGROUND: Dobutamine-stress and dipyridamole-stress echocardiographies are widely used for pharmacological stress echocardiography, with wide geographical variations. OBJECTIVE: To assess whether evidence derived from the literature indicates or disapproves that either stress modality confers diagnostic superiority. METHODS: We performed a meta-analysis of peer-reviewed literature of published trials with head-to-head comparison, on the same population, of high-dose (0.84 mg/kg) dipyridamole-stress versus high-dose (up to 40 micrograms/kg per min) dobutamine-stress echocardiography. Data from 12 studies performed in 12 institutions in seven countries were analysed. Angiographic information about 818 patients was considered. RESULTS: The diagnostic accuracies of the two tests were similar (631 of 818, 77%, for dipyridamole versus 654 of 818, 80%, for dobutamine, NS). Overall sensitivities were 403 of 568 (71%) for dipyridamole and 437 of 568 (77%) for dobutamine (P < 0.05). Sensitivities for patients with single-vessel disease were 177 of 275 (64%) for dipyridamole and 203 of 275 (74%) for dobutamine (P < 0.05). Sensitivities for patients with multivessel disease were 162 of 203 (80%) for dipyridamole and 163 of 203 (80%) for dobutamine (NS). Specificities were 232 of 250 (93%) for dipyridamole and 217 of 250 (87%) for dobutamine (P < 0.05). Data from an additional 26 studies with dipyridamole alone and 47 studies with dobutamine alone were analysed. The diagnostic accuracies were 80% for dipyridamole (n = 2038 patients; 95% confidence interval 75-82%) and 82% for dobutamine (n = 4264 patients; 95% confidence interval 79-84%). CONCLUSION: High-dose dobutamine-stress and high-dose dipyridamole-stress echocardiographies have comparable diagnostic accuracies, with a slightly higher sensitivity with dobutamine and a slightly higher specificity with dipyridamole.

Cardiotonic Agents↗

Dobutamine stress echocardiography: safety in diagnosing coronary artery disease.

Dobutamine stress echocardiography is considered a relatively well-tolerated diagnostic modality, effective in the management of patients with known or suspected coronary artery disease. Adverse effects during testing are relatively frequent, precluding the achievement of a diagnostic end-point in about 5 to 10% of tests. These adverse effects, mostly tachyarrhythmias and arterial hypotension, are usually minor and self limiting. However, severe life-threatening complications, as well as death, also occur. By analysing Medline-quoted literature up to March 1999, we found 35 original studies from a single institution with more than 100 patients, as well as 2 multicentre studies, concerning the feasibility and safety of dobutamine stress echocardiography. In a cumulative total of 26438 tests performed, 79 life-threatening complications (such as acute myocardial infarction, asystole, ventricular fibrillation, sustained ventricular tachycardia or severe symptomatic hypotension) have been reported, giving an incidence of 1 severe adverse reaction per every 335 examinations. In addition, 29 isolated case reports have been published describing life-threatening complications during dobutamine echocardiography. In case reports, 2 deaths have been described, both due to acute cardiac rupture in patients with recent inferior myocardial infarction. Severe adverse reactions during dobutamine echocardiography can be ischaemia independent, and are independent of operator experience and are unpredictable; some complications can be late occurring and long lasting. As a consequence, the procedure must be clearly indicated, written informed consent has to be obtained from the patient, an attending physician must be present during testing, and long term observation of outpatients is useful in order to manage late complications. In conclusion, while the safety of dobutamine stress echocardiography was reported to be outstanding in early reports, further experience presents a substantially more worrying picture. This must be taken into account by both physicians and patients when assessing the risk-benefit profile of the procedure.

Arrhythmias, Cardiac↗

Prognostic value of pharmacological stress echocardiography in patients with known or suspected coronary artery disease: a prospective, large-scale, multicenter, head-to-head comparison between dipyridamole and dobutamine test. Echo-Persantine International Cooperative (EPIC) and Echo-Dobutamine International Cooperative (EDIC) Study Groups.

OBJECTIVES: The study compared the prognostic value of dipyridamole and dobutamine stress echocardiography in patients with known or suspected coronary artery disease. BACKGROUND: Extensive information is available on the relative diagnostic accuracy of the two tests assessed in a head-to-head fashion, whereas comparative data on their prognostic yield are largely preliminary to date. METHODS: Dipyridamole (up to 0.84 mg/kg over 10 min) atropine (up to 1 mg over 4 min) (DIP) and dobutamine (up to 40 microg/kg/min)-atropine (1 mg over 4 min) (DOB) stress tests were performed in 460 patients with known or suspected coronary artery disease. Patients were followed up for 38+/-21 months. RESULTS: The DIP was negative in 253 and positive in 207 patients. The DOB was negative in 242 and positive in 218 patients. During the follow-up, there were 80 cardiac events. For all cardiac events, the negative and positive predictive value were 83% and 17% for DOB, 84% and 19% for DIP, respectively (p = NS). Considering only cardiac death, by univariate analysis Wall-Motion Score Index (WMSI) at DIP peak dose (chi-square 13.80, p<0.0002) was the strongest predictor, followed by WMSI DOB (chi2 = 8.02, p<0.004) and WMSI at rest (chi2 = 6.85, p<0.008). By stepwise analysis, WMSI at DIP peak dose was the most important predictor (RR [relative risk] 7.4, p<0.0001). CONCLUSIONS: In patients at low-to-moderate risk of cardiac events, pharmacological stress echocardiography with either dobutamine or dipyridamole allows effective and grossly comparable, risk stratification on the basis of the presence, severity and extension of the induced ischemia.

Aged↗

Perioperative prognostic value of dipyridamole echocardiography in vascular surgery: A large-scale multicenter study in 509 patients. EPIC (Echo Persantine International Cooperative) Study Group.

BACKGROUND: Patients undergoing major vascular surgery are at a relatively high risk of cardiac events, and pharmacological stress echocardiography is increasingly used for perioperative risk stratification. The aim of the current study was to evaluate the value of dipyridamole echocardiography test (up to 0.84 mg/kg over 10 minutes) in predicting cardiac events in a large-scale, multicenter, prospective, observational study design. METHODS AND RESULTS: Five hundred nine patients (mean age 66+/-10 years) were studied before vascular surgery by dipyridamole stress echocardiography in 11 different centers. All patients underwent preoperative clinical risk assessment according to the American Heart Association guidelines. No major complications occurred during dipyridamole stress echocardiography. Technically adequate images were obtained in all patients; however, in 4 patients only the low dipyridamole dose (0.56 mg/kg over 4 minutes) was given for limiting side effects. Eighty-eight (17.3%) had a positive test. Perioperative events occurred in 31 (6.1%) patients: 6 deaths, 11 myocardial infarctions, and 14 episodes of unstable angina. Sensitivity and specificity of dipyridamole stress echocardiography for predicting spontaneous cardiac events were 81% and 87%, respectively, with a positive predictive value of 28% and negative predictive value of 99%. By multivariate analysis, the difference between wall motion score index at rest and peak stress (Deltawall motion score index), test positivity, and ST-segment depression during dipyridamole infusion were independent predictors of any perioperative cardiac event. CONCLUSIONS: Dipyridamole stress echocardiography is safe and well tolerated in patients undergoing major vascular surgery and provides an effective preoperative screening test for the risk stratification of these patients, mainly because of the extremely high negative predictive value, which is a potent predictor of complication-free procedure.

Aged↗

Comparison of combination of dipyridamole and dobutamine during echocardiography with thallium scintigraphy with thallium scintigraphy to improve viability detection.

The aim of this study was to investigate the relation between radioisotopic and echocardiographic markers of myocardial viability and their correlation with functional recovery after coronary revascularization. Myocardial viability can be detected by techniques exploring various aspects of cell physiology: thallium-201 scintigraphy and dobutamine and dipyridamole echocardiography focus on cell membrane integrity, beta-1 and adrenoceptor, and A2-adenosine receptor-mediated inotropic response, respectively. Fifty-seven patients (mean age 60+/-8 years) with previous myocardial infarction (>3 months), angiographically assessed coronary artery disease, and resting regional dysfunction underwent rest-redistribution 201-thallium scintigraphy and low-dose pharmacologic stress echo with dobutamine (up to 10 microg/kg/min), very low dose regimen of dipyridamole (0.28 mg/kg over 4 minutes), and combined dipyridamole-dobutamine. Criteria for viability in a 13-segment model for both techniques were percent peak activity in redistribution images >55% for thallium-201 and a decrease in wall motion score >1 grade (1 [normal] to 4 [dyskinetic]) for stress echo. Thirty patients underwent coronary revascularization (bypass surgery in 8, angioplasty in 22) and were followed up at 4 weeks from intervention with a resting echocardiogram. The rate of agreement between thallium-201 and stress echo was 63% for dipyridamole, 66% for dobutamine, and 74% for combined dipyridamole-dobutamine (p <0.05 vs dipyridamole and dobutamine). In the 30 patients who underwent revascularization, a regional resting dyssynergy was observed in 225 segments, assuming that postrevascularization functional recovery (which occurred in 126 segments) was the gold standard; combined dipyridamole-dobutamine showed a higher sensitivity (90% confidence interval [CI] 85% to 95%) than thallium-201, dobutamine, or dipyridamole (87%, CI 81% to 92%; 82%, CI 76% to 89%; and 82%, CI 76% to 89%, respectively). Specificity was lower for viability recognition with thallium-201 (61%, CI 51% to 71%) than with dobutamine (93%, CI 88% to 98%), dipyridamole (95%, CI 91% to 99%), and combined dipyridamole-dobutamine (92%; CI 87% to 97%). Combined adrenergic and adenosinergic stimulation recruits an inotropic reserve in a significant proportion of segments with preserved thallium uptake that were nonresponders after either dipyridamole or dobutamine. When functional recovery after successful revascularization is considered as the postoperative gold standard, thallium has a higher sensitivity than dipyridamole or dobutamine; this sensitivity gap is filled with combined dipyridamole-dobutamine. The specificity of all forms of pharmacologic stress echo is better than thallium-201.

Cardiotonic Agents↗

Dipyridamole stress echocardiography.

Dipyridamole stress is the forerunner and prototype of pharmacological stress echo tests in the diagnosis of coronary artery disease. The safety of this test has been conclusively demonstrated as a result of extensive experience in large-scale multicenter projects. The diagnostic accuracy of dipyridamole stress echo is comparable to dobutamine and largely a function of the employed dose. Higher dosages (up to 0.84 mg/kg) are being required to achieve good sensitivity. The prognostic value has been shown to be independent and additive to clinical, exercise echocardiogram, and angiographic data. The test positive response should be titrated on the basis of severity, extent, and timing of induced dyssynergy with low positivity being associated to more anatomically and functionally severe forms of disease. Multicenter, randomized, prospective, international studies on cost-effectiveness directly comparing a noninvasive strategy centered on stress echo versus an invasive strategy centered on coronary angiography are currently ongoing.

Adrenergic beta-Agonists↗

The flow-function relationship in patients with chronic coronary artery disease and reduced regional function: a Doppler transesophageal and bidimensional transthoracic echocardiography study.

BACKGROUND: Infra-low dose dipyridamole allows one to selectively explore myocardial viability. Transesophageal echocardiography Doppler measurement of left anterior descending coronary artery flow at baseline and following dipyridamole is an efficient tool to assess coronary flow response. Aim of this study was to determine the flow-function relationship during coronary vasodilatory stress in patients with coronary artery disease and baseline dysfunction. METHODS AND RESULTS: Twelve patients with resting dyssynergies and 6 controls underwent assessment of regional function and of left anterior descending blood flow velocity. Flow and function were evaluated at rest and following infra-low dose dipyridamole (0.28 mg/Kg over 4 min). Controls showed a normal function at rest and after dipyridamole. Six patients ('Responders') with resting dyssynergies showed an improvement in segments of left anterior descending artery territory, whereas the other six ones ('Non-responders') showed no functional change. Controls and 'Responders' had similar values of resting peak diastolic left anterior descending artery flow velocity both at rest and after dipyridamole, whereas 'Non-responders' showed a blunted flow response to dipyridamole. CONCLUSION: Myocardial segments with a resting dysfunction and a contractile reserve more often exhibit a residual flow response, whereas segments with fixed pattern show a flat flow response during coronary vasodilator stress.

Blood Flow Velocity↗

Diagnostic and prognostic value of vasodilator stress echocardiography in asymptomatic Type 2 diabetic patients with positive exercise thallium scintigraphy: a pilot study.

AIM: To assess the diagnostic and prognostic value of vasodilator stress echocardiography in Type 2 diabetic patients with positive exercise perfusion scintigraphy. METHODS: Of an initial cohort of 50 asymptomatic Type 2 diabetic patients undergoing exercise single photon emission computed tomography (SPECT) thallium scintigraphy, 24 had a positive thallium scan, with a reversible perfusion defect. All these 24 underwent high dose (up to 0.84 mg/kg in 10 min) dipyridamole echocardiography and coronary angiography independently of stress echocardiography results. All patients were then followed for 61+/-22 months. RESULTS: Coronary angiography showed normal coronary arteries in 11 patients and significant (> 50% visually assessed diameter reduction in a major vessel) coronary artery disease in 13. Stress echocardiography showed 92% sensitivity and 100% specificity for non-invasive detection of coronary artery disease. During follow-up, five patients experienced cardiac events: heart failure in one, angina with subsequent revascularization in two, and myocardial infarction in two. Event-free survival was 100% in the 12 patients with negative and 58% in the 12 patients with positive stress echocardiography (P = 0.08 by Mantel-Cox test). CONCLUSIONS: In asymptomatic Type 2 diabetic patients with stress-induced perfusion defects, vasodilator stress echocardiography is an excellent diagnostic and prognostic tool proven with long-term follow-up.

Coronary Angiography↗

Madness and method in stress echo reading.

AIM: To assess whether 'eye education' through short-term, high-intensity joint reading sessions may improve diagnostic accuracy and inter-observer agreement among beginners. METHODS AND RESULTS: Seventeen cardiologists with absent to minimal (<100 studies performed) previous stress echo experience independently and blindly read 18 stress echo studies, nine at the beginning ('pre-training' set) and nine at the end ('post-training' set) of a 2 day stress echo school which included a joint reading session of 50 tapes. The two sets were balanced as far as type of stress and image quality. The 17 observers had an average accuracy score of 51+/-16.4 before and 64.3+/-8.7% after the training (P<0.005). Concordant (i.e. >14 readers giving the same response) interpretation occurred in three out of nine studies before and in eight out of nine studies after the training (33% vs 88%, P<0.01). Kappa values went from 0.14 (poor) before to 0.39 (fair, close to moderate) after the training. CONCLUSION: Short-term, high-intensity dedicated training in stress echo, with joint reading sessions and consensus development of reading criteria significantly increased accuracy and markedly reduced the inter-observer variability in the reading of stress echoes by beginners. If there is a Shakespearean madness in stress echo reading, 'yet there is a method in't' (Hamlet, II, II, 205-206).

Clinical Competence↗

Pharmacologic stress echocardiography in the assessment of coronary artery disease.

Pharmacologic stress echocardiography has gained widespread popularity in recent years because it is more feasible for the patient and less technically demanding for the echocardiographer than exercise stress testing. The two most popular pharmacologic stresses are dobutamine and dipyridamole. These agents provide similar prognostic value and diagnostic accuracy for angiographically assessed coronary artery disease; dobutamine has marginally higher sensitivity in single-vessel disease, and dipyridamole has marginally higher specificity in patients with normal coronary arteries. Both stresses are safe, but a physician should always be in attendance when they are administered: Life-threatening reactions can occur in one of 300 to 500 cases with dobutamine and in one of 700 to 1500 cases with dipyridamole. For dipyridamole and dobutamine echocardiography, outcome data are available from multicenter, international, observational, prospective studies, such as the EPIC (Echo Persantine International Cooperative) and EDIC (Echo Dobutamine International Cooperative).

Cardiotonic Agents↗

Effects of chronic long-term therapy with calcium antagonists on cytogenetic damage in humans.

OBJECTIVE: To assess whether chronic long-term calcium antagonist therapy may increase genotoxicity, the chromosome aberration test, a widely accepted genotoxic assay, was used ex vivo in peripheral human lymphocytes of patients with or without long-term exposure to calcium antagonist therapy. METHODS AND RESULTS: In a case-control study design, we evaluated 30 ischaemic and/or hypertensive patients (22 males, eight females; age 59.4+/-1.5 years), under chronic calcium antagonist treatment (group I), for more than 3 years (4.4+/-0.34 years) and 30 age-matched subjects, without any previous exposure to calcium antagonists (group II). Venous blood samples were collected from the patients and cultures were set up for cytogenetic analysis by standard methods. For each subject, 100 metaphases were scored. The two groups showed similar values (mean +/- SEM) for percentage aberrant cells (group I 2.6+/-0.3 versus group II 2.5+/-0.3, not significant), percentage structural aberrations (group I 1.9+/-0.3 versus group II 1.8+/-0.2, not significant) and percentage numerical aberrations (group I 0.70+/-0.2 versus group II 0.73+/-0.2, not significant). CONCLUSIONS: Long-term calcium antagonist therapy is not associated with an increased incidence of chromosomal indices of genotoxic damage in humans.

Calcium Channel Blockers↗

High dose dipyridamole myocardial imaging: simultaneous sestamibi scintigraphy and two-dimensional echocardiography in the detection and evaluation of coronary artery disease. Italian Group of Nuclear Cardiology.

BACKGROUND: Dipyridamole stress combined with echocardiography or perfusion scintigraphy can be used to detect coronary artery disease, but head-to-head comparative data are lacking. The aim of this study was to compare the relative accuracy of high-dose dipyridamole stress imaging (up to 0.84 mg/kg over 10 min) with two-dimensional echocardiography and sestamibi perfusion scintigraphy in detecting coronary artery disease. METHODS: One-hundred and one patients with a history of chest pain and no previous myocardial infarction, were studied simultaneously using planar perfusion scintigraphy and echocardiography during a high-dose dipyridamole stress, at seven different institutions. RESULTS: During coronary angiography, 21 patients had non-significant lesions, and 80 had significant lesions (> or = 50% diameter reduction): 37 had single-, 19 double- and 24 triple-vessel disease. Sensitivity for disease detection was 78% [95% confidence interval (CI) 67-86%] for echocardiography and 79% (CI 68-87%) for scintigraphy. The specificity was 76% (CI 67-84%) for echocardiography and 90% (CI 83-95%) for scintigraphy. The inter-center variation in accuracy ranged from 50 to 100% for echocardiography (coefficient of variation 19.7%) and from 71 to 100% for scintigraphy (coefficient of variation 15%). The angiographically assessed extent and severity of coronary artery disease, evaluated using the Duke score, was correlated to the extent and severity of perfusion defects with scintigraphy (r = 0.65, P < 0.0001) and regional wall motion abnormalities by echocardiography (r = 0.57, P < 0.0001). CONCLUSIONS: Perfusion scintigraphy and echocardiography have similar accuracies for the non-invasive identification of angiographically assessed coronary artery disease during high-dose dipyridamole stress. Inter-center variability in diagnostic accuracy is higher for echocardiography than scintigraphy. Both methods allow a reasonably accurate estimation of extent and severity of disease, via a semiquantitative assessment of extent and severity of perfusion of functional defects.

Aged↗

The alternative "ischemic" cascade in coronary microvascular disease.

The conceptual model of the classical "ischemic cascade" has served cardiologists well for decades. It correctly predicts clinical findings during imaging stress testing in the presence of coronary artery disease or epicardial coronary artery spasm, where perfusion and wall motion abnormalities provide a substantially higher sensitivity than ECG changes. However, empirical experience has taught us that stress-induced ischemic-like ECG changes, often accompanied by perfusion abnormalities, are the rule rather than the exception in pathophysiological conditions during which the occurrence of ischemia usually cannot be proven, characterized by angiographically normal arteries and reduced flow reserve, such as syndrome X, arterial hypertension and hypertrophic cardiomyopathy. These stress-induced "echocardiographically silent" ST segment changes may be associated with impaired coronary flow reserve and systemic endothelial dysfunction. In hypertrophic cardiomyopathy stress-induced ischemic-like ST segment depression is linked to higher long-term incidence of adverse events. It is entirely likely that our monolithic view of ischemia mirrored in the classical ischemic cascade should be integrated by the awareness of the reverse or alternative "ischemic" cascade best describing microvascular disease, with ECG changes coming first, perfusion abnormalities second, and echocardiographic changes usually being absent. Not all forms of myocardial ischemia are the same, and milder, patchy degrees of myocardial ischemia--as those hypothesized, but not proven, in microvascular angina--remain silent in its mechanical functional manifestations and may well represent a physiological scotoma of stress echocardiography. "Anatomic lies" on the ECG may be overturned into "physiologic truths" when coronary flow reserve or systemic endothelial function is considered.

Coronary Circulation↗

Safety of ergotamine-ergic pharmacologic stress echocardiography for vasospasm testing in the echo lab: 14 year experience on 478 tests in 464 patients.

BACKGROUND: The safety of ergonovine/ergometrine stress testing for coronary vasospasm when performed outside the cath lab has vigorously been questioned. The aim of this study was to assess the value of ergonovine/ergometrine stress testing performed in the echo lab. METHODS: We retrospectively reviewed the data prospectively collected in the echo lab of the Institute of Clinical Physiology of Pisa (Italy) from January 1, 1985, to October 1, 1998, on 478 tests performed on 464 patients with either ergonovine or ergometrine stress echo testing. By selection, all patients had history of chest pain, consistent with vasospastic angina, negative or ambiguous exercise stress testing, and normal or near normal resting left ventricular function. Ergonovine or ergometrine maleate was injected up to a total cumulative dosage of 0.35 mg, under continuous 12 lead ECG and two-dimensional echo monitoring. RESULTS: There were no death, myocardial infarction, ventricular fibrillation or III degree atrioventricular block. One patient had non-sustained ventricular tachycardia associated with transient ST segment elevation 30 min after the test. Two patients had II degree atrioventricular block, associated with positive echocardiography test and promptly reversed by nitrate administration. Transient regional myocardial dysfunction occurred in 74 patients (15%). Limiting ischemia-independent side effects were present in 13 patients (3%): hypotension in 1, arterial hypertension in 5, nonsustained ventricular tachycardia in 2, and nausea/vomiting in 5. The overall feasibility was 97%. CONCLUSIONS: Pharmacological stress echocardiography with either ergonovine or ergometrine is highly feasible and can be safely performed in the echo lab in properly selected patients in whom coronary vasospasm is suspected. It is often the only way to document coronary vasospasm otherwise missed by conventional noninvasive stress test and even by coronary angiography.

Coronary Angiography↗

Coronary vasospasm as a source of false positive results during dobutamine echocardiography.

BACKGROUND: Several studies have demonstrated a consistently high sensitivity of dobutamine echocardiography whereas test specificity in these series has been variable. The aim of this study was to evaluate whether coronary vasospasm--elicited by alpha1 adrenoreceptor stimulation--may be a significant source of false positive responses during dobutamine stress. METHODS: From the data bank of four institutions we selected 113 patients (75 males, 38 females, mean age 55 +/- 12 years) with dobutamine echocardiography performed (up to 40 micrograms/kg/min and atropine 1 mg if needed) before a coronary angiography showing normal or near normal (visually assessed stenosis severity < 50%) coronary arteries. The following variables--which were previously reported influencing dobutamine echo specificity--entered the multivariate statistical analysis: age, sex, heart rate at baseline and at peak stress, baseline echo, hypertension, site of asynergy, and spasm at coronary angiography. RESULTS: Twenty-five patients had a positive dobutamine test. The positivity occurred in the left coronary territory in 15 and in the right coronary territory in 10 cases. All the 6 patients with spontaneous spasm during angiography had a false positive stress test result. By multivariate analysis only coronary artery spasm during angiography (p = 0.0015) and history of hypertension (p = 0.0031) were significant predictors of false positive results of dobutamine stress echocardiography. CONCLUSIONS: Coronary artery spasm may be an important source of false positive results during dobutamine stress echocardiography.

Coronary Disease↗

Anticoagulants.

Explore the source record for details and available documents.

Journal Article↗

Standardized guidelines for the interpretation of dobutamine echocardiography reduce interinstitutional variance in interpretation.

Subjective interpretation of dobutamine echocardiograms provides only moderate interinstitutional observer agreement if nonunified data acquisition and assessment criteria are applied. The present study was undertaken to evaluate parameters associated with low interinstitutional observer agreement in the interpretation of dobutamine echocardiograms and to analyze whether standardized interpretation criteria improve interinstitutional observer agreement. One hundred fifty dobutamine echocardiograms (dobutamine up to 40 microg/kg/min body weight and atropine up to 1 mg) were evaluated at 5 centers. Clinical, procedural, and echocardiographic parameters were included in the analysis of variables with significant impact on interinstitutional agreement. Standardized interpretative criteria were established, and 90 dobutamine echocardiograms were reanalyzed by 3 observers using a standardized image display. Multivariate analysis demonstrated low image quality (odds ratio [OR] 0.19, 95% confidence interval [CI] 0.08 to 0.45, p=0.0002), low severity of induced wall motion abnormality (OR 0.17, 95% CI 0.07 to 0.40, p <0.0001), and a low peak rate-pressure product (OR 0.93, 95% CI 0.43 to 2.27, p=0.0382) to result in a low interinstitutional agreement. Standardization of image display in cine loop format and of dobutamine stress echo interpretation criteria resulted in improvement in test result categorization as normal or abnormal, with a kappa value of 0.50, compared with 0.39 using the original subjective interpretation. In conclusion, image quality, the severity of induced wall motion abnormalities, and the obtained rate-pressure product have a significant impact on the interpretation homogeneity of dobutamine echocardiograms. Standardization of image display in cine loop format and of reading criteria results in improved interinstitutional agreement in interpretation of stress echocardiograms.

Adult↗