Search PubMed⌕ Search

Biomedical subjects

E Pişkin

Publications and source records attributed to E Pişkin.

At least 19 recordsLinked to original sources

In vivo performance of antibiotic embedded electrospun PCL membranes for prevention of abdominal adhesions.

The aim of this study was to prepare nonwoven materials from poly(epsilon-caprolactone) (PCL) and their antibiotic containing forms by electrospinning, so as to prevent postsurgery induced abdominal adhesions in rats. epsilon-Caprolactone was first polymerized by ring-opening polymerization, and then it was processed into matrices composed of nanofibers by electrospinning. A model antibiotic (Biteral) was embedded within a group of PCL membranes. In the rat model, defects on the abdominal walls in the peritoneum were made to induce adhesion. The plain or antibiotic embedded PCL membranes were implanted on the right side of the abdominal wall. No membrane implantation was made on the left side of the abdominal wall that served as control. Macroscopical and histological evaluations showed that using these barriers reduces the extent, type, and tenacity of adhesion. The antibiotic embedded membranes significantly eliminated postsurgery abdominal adhesions, and also improved healing.

Abdomen↗

Attachment and growth of fibroblasts on poly(L-lactide/epsilon-caprolactone) scaffolds prepared in supercritical CO2 and modified by polyethylene imine grafting with ethylene diamine-plasma in a glow-discharge apparatus.

In this study, a copolymer of L-lactide and epsilon-caprolactone (Mn: 73,523, Mw: 127,990 and PI: 1.74) was synthesized by ring-opening polymerization by using stannous octoate as the catalyst. FTIR, 1H-NMR and DSC confirmed the copolymer formation. The copolymer films were prepared and a novel method was developed to produce highly porous sponges for potential use in tissue engineering. Films were subjected to supercritical CO2 at 3300 psi and 70 degrees C to create porous structures for production of possible tissue engineering scaffolds. The pore sizes were in the range of 40-80 microm. The copolymer films were pre-wetted with polyethylene imine (PEI) and then treated with ethylene diamine (EDA)-plasma in glow-discharge apparatus. Gas plasma surface modification of three-dimensional scaffolds fabricated by supercritical carbon dioxide technique was demonstrated to enhance cell adhesion, proliferation, and differentiation over 6 days in culture using L929 fibroblast cell line. Alkaline phosphatase (ALP) activity and glucose uptake in cell culture medium were followed in the cell culture experiments. Fibroblastic cell attachment and growth on the EDA-plasma treated scaffolds were rather low. However, both cell attachment and growth were significantly increased by PEI pre-treatment before EDA-plasma. The changes in ALP activity and glucose uptake also supported the cell growth behavior on these PEI and EDA-plasma treated scaffolds.

Carbon Dioxide↗

Intelligent polymers as nonviral vectors.

The successful gene therapy largely depends on the vector type that allows a selective and efficient gene delivery to target cells with minimal toxicity. Nonviral vectors are much safer and cheaper, can be produced easily in large quantities, and have higher genetic material carrying capacity. However, they are generally less efficient in delivering DNA and initiating gene expression as compared to viral vectors, particularly when used in vivo. As nonviral vectors, polycations may work well for efficient cell uptake and endosomal escape, because they do form compact and smaller complexes with plasmid DNA and carry amine groups, which give positive charge and buffering ability that allows safe escape from endosome/lysosome. However, this is a disadvantage in the following step, which is releasing the plasmid DNA within the cytosol. In order to initiate transcription and enhance gene expression, the polymer/plasmid complex should dissociate after releasing from endosome safely and effectively. There are also other limitations with some of the polycationic carriers, for example, aggregation, toxicity, etc. Intelligent polymers, also called as 'stimuli responsive polymers', have a great potential as nonviral vectors to obtain site-, timing-, and duration period-specific gene expression, which is already exhibited in recent studies that are briefly summarized here.

Biotechnology↗

In vitro and in vivo degradation of non-woven materials made of poly(epsilon-caprolactone) nanofibers prepared by electrospinning under different conditions.

The aim of this study was to prepare non-woven materials from a biodegradable polymer, poly(epsilon-caprolactone) (PCL) by electrospinning. PCL was synthesized by ring-opening polymerization of epsilon-caprolactone in bulk using stannous octoate as the catalyst under nitrogen atmosphere. PCL was then processed into non-woven matrices composed of nanofibers by electrospinning of the polymer from its solution using a high voltage power supply. The effects of PCL concentration, composition of the solvent (a mixture of chloroform and DMF with different DMF content), applied voltage and tip-collector distance on fiber diameter and morphology were investigated. The diameter of fibers increased with the increase in the polymer concentration and decrease in the DMF content significantly. Applied voltage and tip-collector distance were found critical to control 'bead' formation. Elongation-at-break, ultimate strength and Young's modulus were obtained from the mechanical tests, which were all increased by increasing fiber diameter. The fiber diameter significantly influenced both in vitro degradation (performed in Ringer solution) and in vivo biodegradation (conducted in rats) rates. In vivo degradation was found to be faster than in vitro. Electrospun membranes were more hydrophobic than PCL solvent-casted ones; therefore, their degradation was a much slower process.

Absorbable Implants↗

Gene delivery: intelligent but just at the beginning.

Gene therapy is used to treat genetic disorders, which may be achieved both ex vivo and in vivo. Gene-delivery systems usually include a carrier system which both protects the gene expression plasmid and allows its extracellular and intracellular trafficking. Viruses are used in most of the clinical trials today; however, they do have important drawbacks. Non-viral vectors based on lipids, water-soluble polycations, other non-condensing polymers and nano- or microparticles/capsules have been proposed. Cationic polymers, especially carrying novel targeting ligands. are receiving increasing attention. Intelligent polymers with temperature, pH, and light sensitivities for a controllable and effective non-viral transfection have recently been introduced but are just at the beginning. Our preliminary studies showed that block copolymers of N-isopropylacrylamide-acrylic acid with poly(ethylene imine) could be one example of these novel non-viral vectors.

Biocompatible Materials↗

Pulsatile roller pump perfusion is safe in high risk patients.

In this study, controllability, safety, blood cell depletion, and hemolysis of a pulsatile roller pump in high-risk patients was evaluated. Sarns 8000 roller pump (Sams, Terumo CVS, Ann Arbor, MI, USA) with a pulsatile control module was used as arterial pump in a clinical setting. Forty patients undergoing elective open heart surgery with high-risk either having chronically obstructive pulmonary disease or chronic renal failure were randomly included in the study to be operated on using pulsatile perfusion or non-pulsatile perfusion. Blood samples were withdrawn at induction of anesthesia, at the time of aortic clamping and de-clamping and at 1 hour and 24 hours following cessation of the bypass. Hematocrit and plasma free hemoglobin values were measured. We observed that the pulsatile roller pump perfusion and the extracorporeal circuit used in the clinical study is safe in high-risk patients undergoing cardiopulmonary bypass. We did not face any emboli, hemolysis, or technical problems. Pulsatile roller pump perfusion with Sarns 8000 heart-lung machine is a simple and reliable technique and can be easily applied during open heart surgery.

Adult↗

A novel biodegradable PCL film for tendon reconstruction: Achilles tendon defect model in rats.

This study aims to investigate applicability of poly(epsilon-caprolactone) (PCL) biodegradable films for repair of gaps in Achilles tendons in a rat model, also comparing surgical repair versus no repair approaches. PCL was synthesized with tailor-made properties, then, PCL films were prepared by solvent casting. Seventy-five outbred Sprague-Dawley rats were randomly allocated into five groups: (i) sham operated (skin incision only); (ii) no repair (complete division of the Achilles tendon and plantaris tendon without repair); (iii) Achilles repair (with a modified Kessler type suture); and (iv) plasty of Achilles tendon defects with the biodegradable PCL films, and (v) animals subjected to 1 cm mid-substance defect with no repair. Functional performance was determined from the measurements of hindpaw prints utilizing the Achilles functional index. The animals were killed 8 weeks after surgery and histological and biomechanical evaluations were made. All groups subjected to Achilles tendon division had a significant functional impairment that gradually improved so that by day 28 there were no functional impairments in any group whereas animals with a defect remained impaired. The magnitude of the biomechanical and morphological changes at postoperative 8 weeks were similar for no repair group (conservative), Achilles repair group and tendonplasty group (biodegradable PCL film group). The initial rate of functional recovery was significantly different for primary suture, Achilles repair group and PCL film group (p>0.01). But, at the 28th day, functional recovery was quite similar to the other groups. In summary, our results suggest that the PCL film can be an alternative biomaterial for tendon replacement.

Absorbable Implants↗

Optimization of urease immobilization onto non-porous HEMA incorporated poly(EGDMA) microbeads and estimation of kinetic parameters.

Jack bean urease (urea aminohydrolase, EC 3.5.1.5) was immobilized onto modified non-porous poly(ethylene glycol dimethacrylate/2-hydroxy ethylene methacrylate), (poly(EGDMA/HEMA)), microbeads prepared by suspension copolymerization for the potential use in hemoperfusion columns, not previously reported. The conditions of immobilization; enzyme concentration, medium pH, substrate and ethylene diamine tetra acetic acid (EDTA) presence in the immobilization medium in different concentrations, enzyme loading ratio, processing time and immobilization temperature were investigated for highest apparent activity. Immobilized enzyme retained 73% of its original activity for 75 days of repeated use with a deactivation constant kd = 3.72 x 10(-3) day(-1). A canned non-linear regression program was used to estimate the intrinsic kinetic parameters of immobilized enzyme with a low value of observable Thiele modulus (phi < 0.3) and these parameters were compared with those of free urease. The best-fit kinetic parameters of a Michaelis-Menten model were estimated as Vm = 3.318 x 10(-4) micromol/s mg bound enzyme protein, Km = 15.94 mM for immobilized, and Vm = 1.074 micromol NH3/s mg enzyme protein, Km = 14.49 mM for free urease. The drastic decrease in Vm value was attributed to steric effects, conformational changes in enzyme structure or denaturation of the enzyme during immobilization. Nevertheless, the change in Km value was insignificant for the unchanged affinity of the substrate with immobilization. For higher immobilized urease activity, smaller particle size and concentrated urease with higher specific activity could be used in the immobilization process.

Enzymes, Immobilized↗

Biodegradable polymeric matrices for bioartificial implants.

Biomaterials made of polymers, metals or their alloys, ceramics and their composites, are used as implants to restore or to replace the damaged soft and hard tissue/organ functions for an intended time period. Biomaterials made of synthetic materials are very simple materials compared to their natural counterparts, they only replace very simple functions of the damaged tissue during healing. Natural tissues have been used for both soft and hard repair and replacement, but they do have serious limitations such as: shortage of donor tissue, donor site morbidity, unpredictable resorption characteristics, immunogenic response, risk of disease transmission, and ethical limitations. Tissue engineering is a relatively new approach, in which healthy mammalian cells are used with supporting matrices, usually made of either natural or synthetic polymers as composite bioartificial implants. Primary cells, especially embryonic stem cells, cell lines, hybridomas, genetically modified cells are considered as potential sources for this application. Both closed and open matrices are used as support matrices. Nondegradable and biocompatible microcapsules and hollow fibers are utilized in closed systems, especially for immunoprotection of the transplanted cells. Biodegradable polymers, both natural and synthetic are used in the preparation of bioartificial implants carrying only autogenic cells.

Biocompatible Materials↗

Dye-ligand affinity systems.

Dye-ligands have been considered as one of the important alternatives to natural counterparts for specific affinity chromatography. Dye-ligands are able to bind most types of proteins, in some cases in a remarkably specific manner. They are commercially available, inexpensive, and can easily be immobilized, especially on matrices bearing hydroxyl groups. Although dyes are all synthetic in nature, they are still classified as affinity ligands because they interact with the active sites of many proteins mimicking the structure of the substrates, cofactors, or binding agents for those proteins. A number of textile dyes, known as reactive dyes, have been used for protein purification. Most of these reactive dyes consist of a chromophore (either azo dyes, anthraquinone, or phathalocyanine), linked to a reactive group (often a mono- or dichlorotriazine ring). The interaction between the dye ligand and proteins can be by complex combination of electrostatic, hydrophobic, hydrogen bonding. Selection of the supporting matrix is the first important consideration in dye-affinity systems. There are several methods for immobilization of dye molecules onto the support matrix, in which usually several intermediate steps are followed. Both the adsorption and elution steps should carefully be optimized/designed for a successful separation. Dye-affinity systems in the form of spherical sorbents or as affinity membranes have been used in protein separation.

Chromatography, Affinity↗

Stimuli-responsive properties of conjugates of N-isopropylacrylamide-co-acrylic acid oligomers with alanine, glycine and serine mono-, di- and tri-peptides.

A random oligomer of N-isopropylacrylamide (NIPAAm) and acrylic acid (AAc) with a AAc content of 3.1+/-0.19 mmol carboxylic acid groups per gram of the oligomer and with a number average molecular weight of 1400 was synthesised by a free radical polymerisation using AIBN in DMF. Then, mono-, di-, and tri-peptide conjugates of this oligomer were prepared by using carboxyl-ends-protected (with methyl ester hydrochloride) forms of alanine, glycine and serine, with a water-soluble carbodiimide. 95, 93, and 31% of the carboxylic acids were conjugated (loaded) at the first step (mono-peptides) with glycine, alanine and serine, respectively. At the second step, percentage of the conjugation of carboxylic acid groups with glycine, alanine and serine were between 99 and 80, 68 and 100, and 21 and 58%, respectively, while the third amino acids were attached to only 21-64% of the carboxylic acids available on the conjugate chains. A decrease was observed in the lower critical solution temperatures (LCSTs) of the amino acid conjugates at pH 4.0 compared with the unconjugated oligomer, which has LCST at 37.7 degrees C at the same pH. LCSTs of di- and tri-peptide conjugates at pH 4.0 were in the range of 38.4-43.3 degrees C, and 42.6-50.8 degrees C, respectively. At pH 7.4, LCSTs of the mono- and di-peptide conjugates were observed in the range of 41.6-43.9 degrees C, and 46.2-60.2 degrees C, respectively, while the co-oligomer at pH 7.4 did not show a LCST up to 60 degrees C. Tri-peptide conjugates did not display LCST at pH 7.4, except the one with glycine-alanine-serine sequence.

Acrylamides↗

Biodegradable biocomposite non-woven matrices based on PDLLA- and elastin-solubilized proteins/elastin.

Poly(D,L-lactide) (PDLLA) was synthesized by ring-opening polymerization of D,L-lactide. Non-woven PDLLA matrices were prepared by an extrusion/winding process. The process conditions were optimized and the surfaces of these matrices were modified by glow-discharge treatment and/or glutaraldehyde incorporation for immobilization of elastin-derived proteins (ESP) to the matrix to increase the biocompatibility and also to improve the bioactivity of the matrix. Glow-discharge conditions were optimized. Ethylene diamine (EDA) and Ar were used as the active monomers in the plasma phase. When EDA was used, the glow-discharge treated PDLLA matrices were first allowed to be reacted with glutaraldehyde, although, when Ar used, the treated matrices were used directly for ESP immobilization. The higher degree of immobilization was obtained for EDA and glutaraldehyde. The ESP-incorporated PDLLA matrices were further treated with elastin by cross-reaction of the ESP molecules on the matrix surfaces with elastin. Scanning electron microscopy (SEM) studies showed that ESP were homogeneously deposited the surface of the matrix.

Biocompatible Materials↗

Protein A immobilization and HIgG adsorption onto porous/nonporous and swellable HEMA-incorporated polyEGDMA microspheres.

Both non swellable and swellable poly(EGDMA/HEMA) microbeads were produced by suspension copolymerization. These microbeads were modified by immobilization of a spacer-arm (hexamethylene diamine (HMDA)) and protein A. The optimal values for modifications were as follows: sodium periodate concentration, 1.0 mgml(-1); HMDA concentration, 4 mgml(-1); and glutaraldehyde concentration, 0.070 microgml(-1). Adsorption of protein A onto the plain and periodate oxidized poly(EGDMA/HEMA) microbeads were very close to each other, and were 0.01-0.02 mg protein A on the 1-g Microbeads I and II, respectively. Protein A immobilization on poly(EGDMA/HEMA) microbeads were studied at different temperatures, times, and pHs using single protein solution containing different amounts of proteins. The optimal values for immobilization were as follows: the initial protein A concentration, 0.1 mgml(-1); temperature, 25 degrees C; pH, 9.5; and immobilization time, 120 min. Incorporation of protein A resulted in 1.420 and 1.825 mg protein A on the 1-g Microbeads I and II, respectively. HIgG adsorption capacity on the protein A-incorporated poly(EGDMA/HEMA) microbeads is 27 and 35 mg HIgGg(-1) polymer for Microbeads I and II, respectively.

Adsorption↗

Preparation and properties of poly(L-lactide)/hydroxyapatite composites.

In this study, two different viscosity-average molecular weight (eta = 4.0 and 7.8) poly(L-lactide) (PLLA) were synthesized by ring-opening polymerization and the poly(L-lactide)/hydroxyapatite composites (PLLA/HA) were prepared by blending HA particles (size range: 25-45 microm and Ca/P = 1.69) with a content of 10, 30, and 50 wt% in PLLA solution with further evaporation of the solvent. The plain PLLA polymers and PLLA/HA composites were compression-molded and machined to yield 25 x 3 x 2 mm3 specimens. The molar mass of resulting specimens was decreased drastically due to the hydrolytic and thermal degradation of ester bonds. Scanning electron microscopy and thermal gravimetric results indicated that the compositions of HA in PLLA were well dispersed. With increasing HA content, the crystallinity of PLLA/HA composites are slightly increased due to the effect of HA as a nucleating agent. The dynamic mechanical analysis is useful in studying the viscoelastic behaviour of the PLLA/HA composites and no secondary relaxation was observed below the glass-to-rubber transition (60 degrees C). The mechanical properties of the PLLA/HA composites were found to vary with HA content. Increased levels of HA resulted in increased bending modulus and strength.

Absorbable Implants↗

Attachment of 3T3 and MDBK cells onto poly(EGDMA/HEMA) based microbeads and their biologically modified forms.

Poly(EGDMA/HEMA) based microbeads were prepared by suspension polymerization. A comonomer, i.e., 2-hydroxyethylmethacrylate (HEMA) was included in the recipe in order to have functional hydroxyl groups on the microbead surfaces. Toluene was used in the polymerization formulations to introduce porosity into the matrix. Hydroxyl groups were first oxidized with NaIO4, and then two biological molecules, namely collagen and fibronectin were immobilized by using glutaraldehyde. A spacer-arm, i.e., hexamethylene diamine, was also used in some cases. More protein molecules were immobilized onto more swellable microbeads using spacer-arm. Higher amounts of collagen were immobilized, more than fibronectin immobilization. Attachment of two cell lines (i.e., 3T3 and MDBK cell lines) on these microbeads with a wide variety of surface properties was studied in vitro culture media. Attachments of both cells even onto the plain microbeads were significant. More cells did attach to more swellable microbeads. Introducing both fibronectin and collagen onto the microbeads caused significant increase in the cell attachment. More cells attached to the microbeads carrying fibronectin covalently attached onto the microbeads through the spacer-arm molecules. Fibronectine was better than collagen for high attachment values. The mathematical model proposed successfully simulated attachment kinetics.

3T3 Cells↗

A potential cell affinity sorbent: fibronectin carrying poly(EGDMA/HEMA) microbeads.

Both non-swellable and swellable poly(EGDMA/HEMA) microbeads were produced by suspension copolymerization. These microbeads were modified by immobilization of a spacer-arm (hexamethylene diamine, HMDA) and fibronectin. The optimal values for modifications were as follows: the sodium periodate concentration 1.0 mg ml(-1); the HMDA concentration 4 mg ml(-1); and the glutaraldehyde concentration 0.070 microg ml(-1). Adsorption of fibronectin onto the plain and periodate-oxidized poly(EGDMA/HEMA) microbeads were very similar, and were 0.025-0.035 mg fibronectin per g polymer, respectively. Fibronectin immobilization on poly(EGDMA/HEMA) microbeads were studied at different temperature, time and pH using single protein solution containing different amount of proteins. The optimal values for immobilizations were as follows: the initial fibronectin concentration 0.1 mg ml; temperature + 25 degrees C; pH 7; the immobilization time 120 min. Both fibroblastic 3T3 and epithelial MDBK cells were attached to these unmodified and modified microbeads. The attachments of both 3T3 and MDBK cells, especially to the fibronectin-immobilized swellable microbeads, were very high. Almost 96% of the 3T3 cells available in the cell culture medium did attach to these microbeads (2345 +/- 98 cells per mg of polymer).

3T3 Cells↗

Diamine-plasma treated and Cu(II)-incorporated poly(hydroxyethylmethacrylate) microbeads for albumin adsorption.

Poly(2-hydroxyethylmethacrylate) (PHEMA) microbeads prepared by suspension polymerization were treated with diamine-plasmas (i.e. ethylene-diamine (EDA) and hexamethylene diamine (HMDA)) in a glow-discharge reactor in which the exposure time and glow-discharge power were changed between 5 and 30 min and 5 and 20 W, respectively. The amount of nitrogen deposition increased both with increase in exposure time and glow-discharge power. The maximum amounts of nitrogen deposition on the microbeads were 22.3 and 23.4 micromol g(-1) with the EDA- and HMDA-plasmas. Then, Cu(II) ions were incorporated onto the PHEMA microbeads by chelating with the nitrogen-carrying functional groups. Different amounts of Cu(II) ions (2.4-6.8 mg g(-1)) were incorporated on the PHEMA microbeads by changing the initial concentration of Cu(II) ions. Bovine serum albumin (BSA) adsorption onto the unmodified PHEMA, diamine-plasma treated PHEMA, and diamine-plasma treated Cu(II)-incorporated PHEMA microbeads was investigated. The non-specific adsorption of BSA on the unmodified microbeads was very low (0.22 mg BSA g(-1)). Deposition of nitrogen increased the BSA adsorption (9.3 mg g(-1) for EDA-plasma and 12.7 mg g(-1) for HMDA-plasma). Cu(II)-incorporation significantly increased the BSA adsorption (154 mg g(-1) for EDA-plasma and 178 mg g(-1) for HMDA-plasma). Further increases in the albumin adsorption capacities of the polymer microbeads (185 mg g(-1) for EDA-plasma and 208 mg g(-1) for HMDA-plasma) were observed when human plasma was used. More than 92% of the adsorbed albumin molecules was desorbed in 1 h in the desorption medium containing 0.5 M NaSCN at pH 8.0. Repeated adsorption-desorption cycles showed the feasibility of these plasma-modified polymer microbeads.

Adsorption↗

Characterization of processed tooth hydroxyapatite for potential biomedical implant applications.

In this study hydroxyapatite (HA) (100-150 microns) derived from freshly-extracted human teeth in laboratory conditions was investigated. Scanning electron microscope (SEM), energy dispersive x-ray spectroscopy (EDXS), wet chemical, ion chromatographic peak method (ICP), atomic absorption, x-ray diffraction and infra-red (IR) were performed separately for HA obtained from dentine and enamel. This naturally derived HA did not differ from synthetic ones. Its production was simple when compared with other methods. Processed tooth HA could safely be used in animal subjects prior to human studies as a graft material after biocompatibility studies fully conducted.

Animals↗