Search PubMed⌕ Search

Biomedical subjects

E P Wagner

Publications and source records attributed to E P Wagner.

4 recordsLinked to original sources

A history and review of quantitative electroencephalography in traumatic brain injury.

The electroencephalogram (EEG) is a physiologic measure of cerebral function that has been used by some to assess coma and prognosticate survival and global outcome after traumatic brain injury (TBI). Surface recordings of the brain's electrical activity reveal distinct patterns that indicate injury severity, depth of unconsciousness, and patient survival. The data produced with traditional qualitative studies, however, does not allow resolution and quantification of the wave frequency spectrum present in the brain. As a result, conventional EEG typically has only been used for gross and qualitative analyses and is not practical for use in long-term patient monitoring or as a sophisticated prognostic tool. One area of investigation that is working to address the limitations of conventional EEG has been the development and implementation of Fourier Transform (FT) EEG which resolves and quantifies frequency bands present in the brain. When FT analysis is applied to EEG, it provides concurrent and continuous monitoring, resolution, and quantification of all frequencies emitted. This review discusses the history and significance of conventional EEG and provides a review of how FT-EEG, commonly referred to as Quantitative EEG (QEEG), is being used in the clinical setting. The specific applications and significance of QEEG methods regarding treatment of patients with TBI are discussed in detail. The advantages, disadvantages, and future directions of QEEG in TBI are also discussed.

Brain Injuries↗

Ultratrace determination of lead in whole blood using electrothermal atomization laser-excited atomic fluorescence spectrometry.

Laser-excited atomic fluorescence has been used to detect lead that was electrothermally atomized from whole blood in a graphite furnace. A 9 kHz repetition rate copper vapor laser pumped dye laser was used to excite the lead at 283.3 nm, and the resulting atomic fluorescence was detected at 405.8 nm. No matrix modification was used other than a 1:21 dilution of the whole blood with high-purity water. Using the atomic fluorescence peak area as the analytical measure and a background correction technique based upon a simultaneous measurement of the transmitted laser intensity, excellent agreement for NIST and CDC certified whole blood reference samples was obtained with aqueous standards. A limit of detection in blood of 10 fg/mL (100 ag absolute) was achieved.

Calibration↗