[Dynamic evaluation of the hypothalamo--pituitary-gonadal axis in man].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to E Mattar.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A method is described for the enzymatic radioiodination of human follicle-stimulating hormone (hFSH) by a system consisting of lactoperoxidase, hydrogen peroxide and Na125I. It was compared with the Chloramine-T modified technique. A satisfactory specific activity of the labelled hormone was obtained with the enzymatic iodination with much greater immunoreactivity was stability than after Chloramine-T.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Plasma progesterone levels during the follicular and luteal phases were compared when measured simultaneously by competitive protein binding (using guinea pig sera as binding agent) and radioimmunoassay (antiserum against progesterone-11-alpha-succinyl bovine serum albumin in rabbits), the values obtained were significantly different within each technique, depending on whether previous thin-layer chromatographic purification of the extracts was employed or not. No significant differences were noticed between CPB and RIA when the chromatographic step was used, but when it was omitted, CPB was greater than RIA at the follicular but not at the luteal phase.
In cooperation with the Department of Electronic Data Processing Systems we have developed a data processing unit for the analysis of hemodynamic data at the Department of Internal Medicine I. The aim was to design a computer-system for the daily routine in heart-catheterizations as well as for the solution of scientific problems during hemodynamic studies. In the on-line-mode besides the ECG up to four pressures can be analysed simultaneously. Analog and digital tapes can also be processed off-line on demand. The concept of the whole system and the individual steps of computer-handling are adjusted to the problems of data-analysis in praxis from the viewpoint of the examining cardiologist. Since the system is interactive after each measurement and each given command the computer-results are displayed on the video-scope. Because of the modular structure of the program new medical criteria can easily be implemented at any time. Since the computer-system is not effectively used with only one cath-lab other units possibly of different hard-ware configuration can be connected simultaneously to the computer. Each cath-lab shares 16 K out of the total 32 K core-memory. The results are displayed graphically and alpha-numerically on video-scope, x-y-plotter and line printer. The sampling-rate for fluid-filled catheters is 200 Hz and for catheter-tip-manometers 400 Hz. Smothing and differentiation-procedures are adapted to the respective catheter-material. The computer-program calibrates the different pressure amplifiers automatically. After defining the catheter-position the pressure-signals are sampled for 10 s and immediately afterwards analyzed by the computer. The ECG and the corresponding pressure-curves are displayed on the video-scope. The automatically selected representative beat as well as each of the identified and numerated other beats of the sampling-phase can be displayed selectively together with its numerical results. The computer marks the positions within the pressure-curves, where the individual measurements were taken. Besides the systolic and diastolic pressures in valvular stenosis the maximal and mean systolic or diastolic gradients, ejection- or filling-period, valve-flow and valve-area are calculated autonomously. The calculation of cardiac-output, different volume-indices and stroke-work-index are based on Fick-method, thermo- or indicator-dilution technique. The contractility-parameters max dp/dt, t-max dp/dt, max dp/dt/DP, max dp/dt/P, VPM, V40, min dp/dt and the stiffness are computed for the left and on demand also for the right ventricle. Data of the patient and the operating-team, catheter-technique, complications and free comments are transmitted to the computer via terminal together with the actual time. The computer-system was drafted for permanent use. Therefore possible technical defects have been anticipated in the design of hard- and soft-ware. In cases of failure suitable steps allow the immediate restart of the system without loosing information...
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.