Search PubMed⌕ Search

Biomedical subjects

E Manjarrez

Publications and source records attributed to E Manjarrez.

13 recordsLinked to original sources

Phantom reflexes: muscle contractions at a frequency not physically present in the input stimuli.

In the motor system, the periodic stimulation of one Ia-afferent input produces reflex muscle contractions at the input frequency. However, we observed that when two Ia monosynaptic reflex-afferent inputs are involved the periodic muscle contractions may occur at a frequency physically not present in the afferent inputs even when these inputs are sub-threshold. How can the muscles respond with such phantom reflex contractions at a frequency physically absent in the sub-threshold Ia-afferent input stimuli? Here we provide an explanation for this phenomenon in the cat spinal cord, that we termed "ghost motor response". We recorded monosynaptic reflexes in the L7 ventral root, intracellular potentials in the motoneurons, and the associated muscular contractions elicited by stimulation of the lateral and medial gastrocnemius nerves. By stimulating with periodic pulses of sub-threshold intensities and distinct frequencies of 2 and 3 Hz the lateral and medial gastrocnemius nerves, respectively, we observed monosynaptic responses and phantom reflex muscle contractions occurring at the fundamental frequency (1 Hz), which was absent in the input stimuli. Thus we observed a reflex ghost motor response at a frequency not physically present in the inputs. We additionally studied the inharmonic case for sub-threshold stimuli and observed muscular contractions occurring at much lower frequencies, which were also conspicuously absent in the inputs. This is the first experimental evidence of a phantom reflex response in the nervous system. The observed behavior was modeled by numerical simulations of a pool of neurons subjected to two different input pulses.

Animals↗

Spinal source for the synchronous fluctuations of bilateral monosynaptic reflexes in cats.

Successive stimuli of constant intensity applied to Ia afferents produce spinal monosynaptic reflexes (MSRs) of variable amplitude. We recorded simultaneous MSRs in the left and right L7 (or L6) ventral roots of anesthetized cats. We analyzed the cross-covariance (CCV) between the amplitudes of bilateral MSRs. Long-time series (5 to 8 h) of these bilateral MSRs exhibited transitory changes in their covariations (as measured by the zero-lag peak of their CCV), thus suggesting the existence of certain neural sources contributing to produce these changes. The aim of the present study was to show that spinal centers producing negative spontaneous cord dorsum potentials (nSCDPs) contribute to maintain correlations in the amplitude of bilateral MSRs. After spinal cord transection at the L1 segment, no significant changes were observed in the correlation between the amplitude of bilateral nSCDPs versus the amplitude of bilateral MSRs. However, this correlation, as well as the peak at zero lag in the CCV between bilateral MSRs and the CCV between bilateral nSCDPs, respectively, were abolished after a subsequent longitudinal bisection at the L1-S2 spinal segments. These results suggest that lumbar spinal neurons (bilaterally interconnected) contribute to maintain the synchronous fluctuations of bilateral MSRs.

Animals↗

Persistence of PAD and presynaptic inhibition of muscle spindle afferents after peripheral nerve crush.

Two to twelve weeks after crushing a muscle nerve, still before the damaged afferents reinnervate the muscle receptors, conditioning stimulation of group I fibers from flexor muscles depolarizes the damaged afferents [M. Enriquez, I. Jimenez, P. Rudomin, Changes in PAD patterns of group I muscle afferents after a peripheral nerve crush. Exp. Brain Res., 107 (1996), 405-420]. It is not known, however, if this primary afferent depolarization (PAD) is indeed related to presynaptic inhibition. We now show in the cat that 2-12 weeks after crushing the medial gastrocnemius nerve (MG), conditioning stimulation of group I fibers from flexors increases the excitability of the intraspinal terminals of both the intact lateral gastrocnemius plus soleus (LGS) and of the previously damaged MG fibers ending in the motor pool, because of PAD. The PAD is associated with the depression of the pre- and postsynaptic components of the extracellular field potentials (EFPs) evoked in the motor pool by stimulation of either the intact LGS or of the previously damaged MG nerves. These observations indicate, in contrast to what has been reported for crushed cutaneous afferents [K.W. Horch, J.W. Lisney, Changes in primary afferent depolarization of sensory neurones during peripheral nerve regeneration in the cat, J. Physiol., 313 (1981), 287-299], that shortly after damaging their peripheral axons, the synaptic efficacy of group I spindle afferents remains under central control. Presynaptic inhibitory mechanisms could be utilized to adjust the central actions of muscle afferents not fully recovered from peripheral lesions.

Animals↗

Intersegmental synchronization of spontaneous activity of dorsal horn neurons in the cat spinal cord.

Extracellular recordings of neuronal activity made in the lumbosacral spinal segments of the anesthetized cat have disclosed the existence of a set of neurons in Rexed's laminae III-VI that discharged in a highly synchronized manner during the occurrence of spontaneous negative cord dorsum potentials (nCDPs) and responded to stimulation of low-threshold cutaneous fibers (<1.5x T) with mono- and polysynaptic latencies. The cross-correlation between the spontaneous discharges of pairs of synchronic neurons was highest when they were close to each other, and decreased with increasing longitudinal separation. Simultaneous recordings of nCDPs from several segments in preparations with the peripheral nerves intact have disclosed the existence of synchronized spontaneous nCDPs in segments S1-L4. These potentials lasted between 25 and 70 ms and were usually larger in segments L7-L5, where they attained amplitudes between 50 and 150 micro V. The transection of the intact ipsilateral hindlimb cutaneous and muscle nerves, or the section of the dorsal columns between the L5 and L6, or between the L6 and L7 segments in preparations with already transected nerves, had very small effects on the intersegmental synchronization of the spontaneous nCDPs and on the power spectra of the cord dorsum potentials recorded in the lumbosacral enlargement. In contrast, sectioning the ipsilateral dorsal horn and the dorsolateral funiculus at these segmental levels strongly decoupled the spontaneous nCDPs generated rostrally from those generated caudally to the lesion and reduced the magnitude of the power spectra throughout the whole frequency range. These results indicate that the lumbosacral intersegmental synchronization between the spontaneous nCDPs does not require sensory inputs and is most likely mediated by intra- and intersegmental connections. It is suggested that the occurrence of spontaneous synchronized nCDPs is due to the activation of tightly coupled arrays of neurons, each comprising one or several spinal segments. This system of neurons could be involved in the modulation of the information transmitted by cutaneous and muscle afferents to functionally related, but rostrocaudally distributed spinal interneurons and motoneurons, as well as in the selection of sensory inputs during the execution of voluntary movements or during locomotion.

Action Potentials↗

Absence of coherence between cervical and lumbar spinal cord dorsal surface potentials in the anaesthetized cat.

Recordings of spontaneous cord dorsum potentials (CDPs) along the longitudinal axis of the spinal cord were made. These recordings were obtained from the surface of the dorsal horn at different points along the spinal cord caudally and cranially in relation to the point giving spontaneous potentials of maximal amplitude. We found two curves (lumbar and cervical) for the longitudinal distribution of the area of the power spectra of these recordings. Each of these curves had a symmetrical decrement on both sides of the position of the point for the maximal area of power. Such points were discovered on the L5-L7 and C3-C4 spinal segments. Spectral analysis of the spontaneous CDPs simultaneously recorded in both regions indicates no evidence of coherence, thus suggesting that the spontaneous CDPs recorded in the lumbar and cervical regions of the pentobarbitone-anaesthetized cat are generated by two independent populations of neurones not functionally interconnected between them.

Action Potentials↗

Internal stochastic resonance in the coherence between spinal and cortical neuronal ensembles in the cat.

Internal stochastic resonance is a phenomenon in which the coherence of a non-linear system is enhanced by the presence of a particular, non-zero level of noise generated by internal or external sources without a periodic input signal. The aim of this study was to demonstrate the experimental occurrence of internal stochastic resonance in the coherence between spinal and cortical neuronal ensembles. Simultaneous recordings of spinal and cortical evoked potentials were made in the somatosensory system of the anaesthetized cat. Evoked potentials were produced by input noise introduced in the tactile stimulation of the hindpaw skin. Coherence between the spinal and cortical evoked activity recorded during different levels of input noise was calculated. All animals showed distinct internal stochastic resonance like behavior. We found that the mean coherence was an inverted U-like function of the level of input noise with a mean coherence peak of 0.43. To our knowledge, this is the first documented evidence of such phenomenon in an in vivo preparation of the central nervous system.

Animals↗

Stochastic resonance in human electroencephalographic activity elicited by mechanical tactile stimuli.

Stochastic resonance (SR) is a phenomenon in which the response of a non-linear system to a weak input signal is optimized by the presence of noise. The aim of this study was to demonstrate the experimental occurrence of SR in electroencephalographic (EEG) activity elicited by mechanical tactile stimuli. Our experiments show that EEG responses evoked by mechanical tactile stimuli in the region overlying the somatosensory cortical area were optimized by the addition of certain noise amplitudes. All subjects showed distinct SR behavior. The signal-to-noise ratio (SNR) of the response evoked by mechanical indentations of the skin was an inverted U-like function of the input noise. As the noise amplitude increased, SNR values became larger. A maximum value was reached with a particular noise amplitude value. Beyond such peak, with higher noise amplitudes, the curve subsided gradually. To our knowledge, this is the first documented evidence that such remarkable phenomenon embodies electrical processes of the human brain. Such behavior might explain related findings described in psychophysical studies.

Adolescent↗

Amplitude of somatosensory cortical evoked potentials is correlated with spontaneous activity of spinal neurones in the cat.

Simultaneous recordings of cortical evoked potentials in the posterior sigmoid gyrus, and spontaneous negative cord dorsum potentials (CDPs) of the L6 lumbar spinal segment, were made in the anaesthetised cat. The electrodes were positioned in cortical and spinal somatosensory regions where the largest spontaneous and evoked negative potentials were detected. Evoked potentials were produced by electrical stimulation to cutaneous nerves or by mechanical stimulation of the hindpaw skin. We found that both electrically and mechanically cortical evoked potentials were facilitated during the spontaneous negative CDPs. The magnitude of such facilitation was proportional to the amplitude of the 'conditioning' spontaneous negative CDPs. This led to a high positive correlation between amplitude fluctuations of spontaneous negative CDPs and fluctuations of the cortical evoked potentials. This observation suggests that transmission of cutaneous sensory information in ascending pathways could be facilitated when dorsal horn spinal neurones are active.

Action Potentials↗

Cortical neuronal ensembles driven by dorsal horn spinal neurones with spontaneous activity in the cat.

Simultaneous recordings of cortical activity, recorded as the cortical local field potential (CLFP) in the contralateral posterior sigmoid gyrus, and the spinal activity, recorded as the cord dorsum potential (CDP) of the L6 lumbar segment, were made in the anaesthetized cat. The electrodes were positioned in somatosensory regions where the largest spontaneous negative CLFPs and CDPs were recorded. We found that spontaneous negative CLFPs were preceded by spontaneous negative CDPs with a mean latency of 14.4+/-3.5 ms. Amplitude of these spontaneous negative CLFPs was abolished after section of the dorsal columns and ipsilateral dorsolateral funiculus. It is concluded that the neurones of the primary somatosensory cortex can be driven by dorsal horn spinal neurones producing the spontaneous negative CDPs. This suggests very strongly that spontaneous neuronal activity in somatosensory regions of the brain is generated not only by ongoing activity of neurones located at supraspinal sites, but also by ongoing activity of spinal neurones.

Action Potentials↗

NO donor SIN-1 potentiates monosynaptic reflexes in the cat spinal cord.

The effect produced by the nitric oxide donor SIN-1 on monosynaptic reflexes was examined. Experiments were performed on anesthetized, paralyzed and spinalized cats. Lumbar monosynaptic reflexes were produced by stimulation of Ia afferents. I.v. application of SIN-1 (500 microg/kg) produced a mean marked potentiation of 704% of pre-drug control (100%) in the amplitude of monosynaptic reflexes. In addition, in other experiments a concentration-dependent effect on the amplitude of monosynaptic reflexes was observed after microinjections of SIN-1 into the ventral horn (1 microl; 10(-12) - 10(-3) M), with a mean facilitatory effect of 355%. In both cases, the potentiation was reversible 45 min after i.v. or local application of SIN-1. These results provide the first evidence that monosynaptic reflexes can be potentiated by nitric oxide.

Animals↗

Nitric oxide modulates spontaneous cord dorsum potentials in the cat spinal cord.

A previous study has shown that lumbar spontaneous cord dorsum potentials (CDPs) are produced by background activity of a neuronal ensemble located in the dorsal horn. Here, the effects produced by intravenous application of the nitric oxide synthase inhibitor L-N(G)-nitro arginine (L-NOARG, 100 microg/kg) and of the nitric oxide donor 3-morpholinosydnonimine hydrochloride (SIN-1, 500 microg/kg) on spontaneous CDPs were examined. Experiments were performed on pentobarbitally anesthetized, paralyzed and spinalized cats. The amplitude of spontaneous CDPs increased after L-NOARG, however, decreased after SIN-1. These observations suggest that electrical activity of dorsal horn neurones generating spontaneous CDPs is dependent on nitric oxide production.

Action Potentials↗

Modulation of synaptic transmission from segmental afferents by spontaneous activity of dorsal horn spinal neurones in the cat.

We examined, in the anaesthetised cat, the influence of the neuronal ensembles producing spontaneous negative cord dorsum potentials (nCDPs) on segmental pathways mediating primary afferent depolarisation (PAD) of cutaneous and group I muscle afferents and on Ia monosynaptic activation of spinal motoneurones. The intraspinal distribution of the field potentials associated with the spontaneous nCDPs indicated that the neuronal ensembles involved in the generation of these potentials were located in the dorsal horn of lumbar segments, in the same region of termination of low-threshold cutaneous afferents. During the occurrence of spontaneous nCDPs, transmission from low-threshold cutaneous afferents to second order neurones in laminae III-VI, as well as transmission along pathways mediating PAD of cutaneous and Ib afferents, was facilitated. PAD of Ia afferents was instead inhibited. Monosynaptic reflexes of flexors and extensors were facilitated during the spontaneous nCDPs. The magnitude of the facilitation was proportional to the amplitude of the 'conditioning' spontaneous nCDPs. This led to a high positive correlation between amplitude fluctuations of spontaneous nCDPs and fluctuations of monosynaptic reflexes. Stimulation of low-threshold cutaneous afferents transiently reduced the probability of occurrence of spontaneous nCDPs as well as the fluctuations of monosynaptic reflexes. It is concluded that the spontaneous nCDPs were produced by the activation of a population of dorsal horn neurones that shared the same functional pathways and involved the same set of neurones as those responding monosynaptically to stimulation of large cutaneous afferents. The spontaneous activity of these neurones was probably the main cause of the fluctuations of the monosynaptic reflexes observed under anaesthesia and could provide a dynamic linkage between segmental sensory and motor pathways.

Action Potentials↗

A microcomputer program for automated neuronal spike detection and analysis.

A system for on-line spike detection and analysis based on an IBM PC/AT compatible computer, written in TURBO PASCAL 6.0 and using commercially available analog-to-digital hardware is described here. Spikes are detected by an adaptive threshold which varies as a function of signal mean and its variability. Since the threshold value is determined automatically by the signal-to-noise ratio analysis, the user is not actively involved in controlling its level. This program has been reliably used for the detection and analysis of the spike discharge of vestibular system afferent neurons. It generates the interval-joint distribution graph, the interval histogram, the autocorrelation function, the autocorrelation histogram, and phase-space graphs, thus, providing a complete set of graphical and statistical data for the characterization of the dynamics of neuronal spike activity. Data can be exported to other software such as Excel, Sigmaplot and MatLab, for example.

Ambystoma↗