Search PubMed⌕ Search

Biomedical subjects

E M Jackson

Publications and source records attributed to E M Jackson.

At least 19 recordsLinked to original sources

Kinetics and plasma concentrations of 26-hydroxycholesterol in baboons.

26-Hydroxycholesterol (26OHC), a major oxysterol in human blood, is believed to play an important role in reverse cholesterol transport, bile acid formation, and regulation of various cellular processes. Using isotope dilution mass spectrometry, we measured plasma 26OHC concentrations in baboons fed either a high cholesterol/saturated fat (HC-SF) or normal chow diet. Plasma 26OHC levels in baboons were comparable to those reported for humans and were positively correlated with plasma cholesterol concentrations. Animals on the HC-SF diet had significantly higher 26OHC levels (0.274+/-0.058 microM, mean+/-S.D.) than those on the chow diet (0.156+/-0.046 microM). In separate experiments, [(3)H]26OHC was injected into four tethered baboons, and multiple blood samples drawn over a 1-h period were analyzed for [(3)H]26OHC and 26OHC. Fitting the specific radioactivity data to a two-pool compartmental model indicated a rapidly turning over plasma compartment (t(1/2) 2.9-6.0 min) and a second compartment with slow turnover (t(1/2) 76-333 min). The calculated 26OHC production rate was 2.5 micromol/kg body weight/day. Assuming all 26OHC is converted to bile acids, the 26OHC production rate corresponds to about 10% of total bile acid production in adult baboons. These results indicate that rapid turnover of plasma 26OHC at submicromolar concentrations could significantly contribute to bile acid synthesis.

Animals↗

A global inventory of hospitals using powder-free gloves: a search for principled medical leadership.

Scientific experimental and clinical studies have demonstrated that cornstarch on surgical and examination gloves promotes disease by acting as a reactive foreign body in tissue and serving as a vector for latex allergy. Consequently, hospitals have selected an innovative glove selection program utilizing only powder-free gloves. Healthcare workers in emergency medical systems are now wearing powder-free, latex-free gloves to care for the growing number of patients sensitized to latex. A global Internet search has now identified 70 hospitals in the United States and three hospitals in Europe that use only powder-free gloves.

Data Collection↗

Failure of glove hole detection device for synthetic gloves.

Holes in latex gloves can be reliably detected by commercially available electronic devices. The purpose of this study was to compare the performance of an electronic glove hole detection device using latex gloves to that of neoprene, vinyl, and nitrile latex-free gloves. The electronic hole detection device accurately detected holes in the latex gloves during the 2-h study. In contrast, the latex-free gloves were immediately conductive of electricity in the absence of holes. Consequently, electronic glove hole detection devices cannot be reliably used with latex-free gloves.

Electronics↗

Biomechanical performance of orthopedic gloves.

The purpose of this study was to compare the biomechanical performance of commercially available orthopedic gloves to that of a single surgical glove, as well as a double glove system. The orthopedic gloves were found to be thicker than the single surgical glove. This increased thickness of the orthopedic glove was associated with a greater resistance to glove puncture. The thickest orthopedic gloves also had reduced tactile sensitivity when compared to the single surgical glove. In addition, the glove donning forces and glove hydration rates varied considerably. These latter biomechanical performance parameters were not significantly related to glove thickness. The double glove systems tested in this study had similar performance characteristics in regard to many of the orthopedic gloves. The glove donning forces for the double glove systems were the lowest of the gloves tested. In addition, the double glove systems displayed the greatest resistance to glove hydration of the gloves tested. Their performance in the glove hydration tests and the force required to don the double glove systems were much more desirable than any of the orthopedic gloves. The results of this study indicate that the double glove systems may provide a desirable alternative to the use of the single orthopedic gloves.

Biocompatible Materials↗

Biomechanical performance of examination gloves.

The purpose of this study was to compare the biomechanical performance of new powder-free commercially available synthetic examination gloves to that of commercially available powder-free latex examination gloves. The synthetic gloves were significantly thinner than the latex gloves. Despite the decreased thickness, all three nitrile gloves, as well as the polyvinyl chloride glove, exhibited a greater resistance to glove puncture. The glove donning forces varied considerably among all gloves, and wet donning forces were greater than dry donning forces. Under dry conditions, the donning forces for the synthetic gloves were less than or equal to the forces for the latex gloves. Because of their increased puncture resistance and similar donning forces, synthetic gloves are a safe alternative to latex examination gloves.

Biomechanical Phenomena↗

Integrity of powder-free examination gloves to bacteriophage penetration.

The purpose of this study was to compare the resistance to viral penetration of powder-free synthetic examination gloves with powder-free latex examination gloves commonly used in hospitals. Because these gloves had no holes, this study examined viral penetration through a membrane. Using a standard bacteriophage penetration model, no bacteriophage penetration was detected through the membrane for any of the gloves tested. The new powder-free nitrile and polyvinyl chloride synthetic examination gloves provided comparable resistance to viral penetration as did the powder-free latex examination gloves.

Bacteria↗

Trigeminal neuralgia: a diagnostic challenge.

A 38-year-old white woman came to the emergency department complaining of severe, unilateral jaw pain. She had consulted her primary care physician and dentist without achieving the correct diagnosis or significant relief of her symptoms. The emergency physician made the diagnosis of trigeminal neuralgia by obtaining a history of severe paroxysmal ipsilateral facial pain activated by numerous facial stimuli. A light stimulation of the trigger point precipitated the pain. Her pain relief from carbamazepine lent further credence to the diagnosis of trigeminal neuralgia and appropriate referral to a neurosurgeon. Pain relief was ultimately achieved for the last 8 months by a neurectomy of the right infraorbital nerve.

Adult↗

Ease of donning commercially available latex examination gloves.

There are a wide variety of latex examination gloves now available for use by health care providers. A prospective randomized trial was completed to quantify the forces required to don a sample of seven cornstarch-lubricated gloves and 13 powder-free latex examination gloves. The data collected was analyzed by a 20 x 2 general factorial ANOVA, as well as two 1-way ANOVAs using a least significance difference post hoc test. Some powder-free gloves can be easily donned with dry or wet hands without tearing with forces comparable to those encountered with powdered gloves. With the advent of these powder-free examination gloves, powdered gloves can now be abandoned, protecting health professionals and patients from the dangers of absorbable dusting powders. Despite the dangers of the absorbable dusting powders and the Food and Drug Administration's requirement for labeling examination glove boxes, some manufacturers of powdered examination gloves do not appropriately label their boxes with a warning to the health professional and patient of the presence of powder.

Gloves, Protective↗

Latex glove penetration by pathogens: a review of the literature.

Universal precautions mandate the use of examination and surgical gloves to protect the health professional from contact with the HIV virus. The purpose of this paper is to provide a review of the literature on the barrier properties of examination and surgical gloves measured by water leakage and viral penetration. The literature data indicate that glove composition, glove manufacturer, glove design (examination vs. surgical), and mechanical manipulation had considerable influence on glove performance when tested for leakage and viral penetration. In general, latex gloves were found to be superior to vinyl gloves as barriers to water leakage and viral penetration.

Bacteriophage phi X 174↗

Influence of latex glove hydration on bacteriophage penetration.

The purpose of this study was to determine whether glove hydration influenced bacteriophage penetration. Using an electronic glove hole-detection device, one brand of latex glove was identified that hydrated rapidly (3.25 min +/- 0.71 min), while another brand was selected that resisted hydration (120 min +/- 0 min). Using a standard bacteriophage penetration model, the amount of bacteriophage penetration in both the rapidly hydrating gloves and the gloves that resisted hydration was extremely small and did not differ significantly from each other.

Bacteriophage phi X 174↗

Comparison testing of the irritancy of children's liquid bubble bath using a modified human repeat insult patch test.

BACKGROUND: Bubble baths are common products used by parents with young children. Some dermatologists and pediatricians do not recommend the use of these products. OBJECTIVE: The purpose of this study was to compare the irritancy of nine children's liquid bubble bath solutions. METHODS: A modified human repeat insult patch test (HRIPT) was used to rank order the irritancy of nine bubble bath preparations. Erythema, scaling, and fissuring were evaluated at the patch test sites. RESULTS: The nine products tested varied in their ability to cause irritation. Based on the degree of erythema, the least irritation was produced with Sesame Street Fresh Apple Splash bubble bath. CONCLUSION: This study suggests that there are differences in the irritancy of brands of children's liquid bubble bath and that recommendations can be made by both dermatologists and pediatricians when parents choose to use these products on their children.

Adult↗

Prognostic patch testing: the other kind of patch test.

Prognostic patch testing differs from diagnostic patch testing. Clinicians routinely perform diagnostic patch testing, but prognotic patch testing is the province of corporate research and development departments and, in the United States, contract laboratories. The three types of prognostic patch testing are described and referenced in the scientific and medical literature. A comparison among the three types of prognostic patch testing and diagnostic patch testing is provided. In addition, the variables in both prognostic and diagnostic patch testing are listed, as well as the types of ingredients and products routinely tested in prognostic patch testing.

Consumer Product Safety↗

Dimensions of care in five United States nursing homes: identifying invisible work in care-giving.

This article reports on a study carried out to identify components of practical knowledge, which is the knowledge that is used to guide decision-making and actions, used by care-givers in nursing homes. The practical knowledge behind the giving of care in the day-to-day activities in five nursing homes was studied and models for such care were developed. One finding from this study was that a large portion of the work of caring as known and understood by care-participants (patients, families, and nursing staff) was excluded from prescribed routines established by administration for care.

Attitude of Health Personnel↗