Search PubMed⌕ Search

Biomedical subjects

E L Snyder

Publications and source records attributed to E L Snyder.

At least 37 records · Page 2Linked to original sources

A prospective, randomized study of the use of platelet concentrates irradiated with ultraviolet-B light in patients with hematologic malignancy.

BACKGROUND: Irradiation of platelet concentrates (PCs) with ultraviolet-B (UVB) light inactivates the contaminating white cells and might be an alternative to filtration for the prevention of alloimmunization to HLA antigens and subsequent refractoriness to further platelet transfusions in multiply transfused patients with bone marrow failure. STUDY DESIGN AND METHODS: Patients with hematologic malignancy, mainly acute myeloid leukemia, were prospectively assigned in a random manner to receive either UVB-irradiated or control, nonirradiated PCs. All patients were given red cells that were white cell reduced by filtration. Transfusion efficacy and alloimmunization were assessed by means of corrected count increments, requirement for red cells and PCs, and measurement of lymphocyte-reactive antibodies. RESULTS: UVB-irradiated PCs had a clinical efficacy similar to controls as judged by corrected count increments at 1 to 6 and 12 to 24 hours and by the median requirement for red cell and platelet transfusions. Alloimmunization determined by measurements of lymphocyte-reactive antibodies using both conventional and antiglobulin-augmented lymphocytotoxicity techniques was not abolished in recipients of UVB-irradiated PCs (4/30, 13%) but was less than that in controls (5/20, 25%; p = NS). The mean number of platelet transfusion episodes prior to the occurrence of alloimmunization was greater in the control group (27 vs. 10; p = 0.017). CONCLUSION: In this trial, UVB irradiation did not diminish the clinical efficacy of platelet transfusions. There was a small but nonsignificant reduction alloimmunization, but no difference in refractoriness of the two groups was observed. Larger prospective randomized studies are required to confirm these findings and to compare UVB irradiation with white cell reduction.

Adolescent↗

Removal of soluble biologic response modifiers (complement and chemokines) by a bedside white cell-reduction filter.

BACKGROUND: Biologic response modifiers infused with stored platelet concentrates (PCs) are believed to contribute to symptoms seen during transfusion reactions. Although prestorage white cell reduction is known to decrease the production of some biologic response modifiers during storage, the possibility that poststorage (bedside) white cell reduction could reduce the amount of biologic response modifiers already present in stored PCs during bedside filtration has not been well studied. STUDY DESIGN AND METHODS: Individual PCs were pooled on storage Days 2 and 5 and passed through a third-generation white cell-reduction filter. The results from a series of in vitro PC assays were studied, before and immediately after filtration, as were levels of C3a and interleukin 8 (n = 5). Levels of other biologic response modifiers-C5a, interleukin 1 beta, interleukin 6, tumor necrosis factor alpha, and RANTES-were also studied. Removal of interleukin 8 and RANTES was studied further by using serial filtration of units of PC. RESULTS: For the in vitro platelet assays studied, pH was unchanged after filtration from prefiltration values in units of PCs pooled on storage Day 2 or 5. A 4 log10 reduction in white cells was reliably seen after filtration in Day 2 and 5 pooled PCs. Postfiltration platelet loss was 14.8 percent for Day 2 pooled PCs and 9.6 percent for Day 5 pooled PCs. For pools of both Day 2 and Day 5 platelets, postfiltration levels of CD62 (P-selectin, CD62P) were unchanged from prefiltration levels, as were results for morphology scores. Levels of C3a decreased after filtration in both the Day 2 pooled PCs (448 ng/mL before filtration vs. 20 ng/mL after filtration) and the Day 5 pooled PCs (1976 ng/mL before filtration vs. 124 ng/mL after filtration). Levels of interleukin 8 were similarly reduced after filtration in the Day 2 pooled platelets (188 pg/mL before filtration vs. 27 pg/mL after filtration) and the Day 5 pooled platelets (2234 pg/mL before filtration vs. 799 pg/mL after filtration). Levels of interleukin 8 in other components evaluated after filtration declined similarly. However, levels of the proinflammatory cytokines interleukin 1 beta and interleukin 6 did not decline after filtration. Serial filtration studies showed that, although levels of interleukin 8 and RANTES were initially lowered by filtration, they returned to prefiltration values with increases in the volume of filtration. CONCLUSION: The third-generation bedside filter used in this study reliably reduced the level of white cell contamination to 4 log10 white cells per PC. It also lowered the levels of interleukin 8, RANTES, and C3a. The filter did not, however, remove (scavenge) the proinflammatory cytokines interleukin 1 beta and 6. The mechanism of chemokine and C3a removal by the filter is unknown, but it may be related to ionic interactions between these biologic response modifiers and the filter medium.

Blood Transfusion↗

Cytokine generation in stored, white cell-reduced, and bacterially contaminated units of red cells.

BACKGROUND: Proinflammatory cytokines were measured in the supernatant portion of stored, bacterially contaminated, and/or white cell (WBC)-reduced units of red cells (RBCs). Previous studies from this laboratory and others have shown that cytokines are generated in platelet concentrates during storage. This earlier work has been expanded to the study of stored RBCs. STUDY DESIGN AND METHODS: Units of AS-1 RBCs (n = 10 non-WBC-reduced; n = 10 WBC-reduced) were obtained from a regional blood center, and each was split on Day 3 of storage into three equal portions by sterile techniques. One portion was kept sterile (control), and the other two were inoculated with Yersinia enterocolitica and Staphylococcus aureus, respectively, at 1 to 3 colony-forming units per mL. The RBCs were stored at 1 to 6 degrees C for 42 days. Sequential samples were taken during storage and assayed for interleukin 8 (IL-8), interleukin 1 beta (IL-1 beta), interleukin 6, WBC count, and bacteria count. For the WBC-reduced group (n = 10), WBC removal was done by filtration on Day 3 of storage, before bacterial inoculation. RESULTS: IL-8 was detected in the supernatant portion of all 42-day-old, non-WBC-reduced (mean WBCs = 4760 +/- 3870/microL) units of AS-1 RBCs at levels ranging from 63 to 1610 pg per mL. By contrast, at 2 to 3 days of storage, lower levels of IL-8 (range, 0-280 pg/mL) were detected in the same units. IL-8 levels increased progressively during storage in most (7/10) units. The highest mean levels of IL-8 were reached by outdate at Day 42. Y. enterocolitica-contaminated units had statistically higher levels of IL-8, with a range of 170 to 2100 pg per mL, by 42 days of storage. S. aureus grew poorly in stored units of RBCs and failed to further stimulate cytokine production. No WBC-reduced unit (mean WBCs = 0.5 +/- 0.6/microL), even when contaminated with bacteria, had more than 260 pg per mL of IL-8. Although IL-1 beta was not detected in any unit of RBCs at 3 days of storage, it increased to low levels (5-13 pg/mL) in all units tested at 42 days. Interleukin 6 was not detected in any unit at any storage time. CONCLUSION: IL-8 and IL-1 beta accumulated in the supernatants of stored RBCs despite cold storage conditions. IL-8 reached levels > 1000 pg per mL in the supernatants of some RBC units. IL-1 beta increased to significant but low levels (< 13 pg/mL). WBC filtration early in storage prevented the accumulation of IL-8. The physiologic significance to transfusion recipients of IL-8 in RBC supernatants is currently unknown and deserves further investigation.

Blood Preservation↗

The effect of solvent/detergent-treated plasma on red cells stored in vitro.

BACKGROUND: The potential use of solvent/detergent-treated plasma (S/D plasma) in transfusion practice raises concerns about the cytolytic effects that any residual solvent and detergent in the virally inactivated blood component might have on units of red cells in vitro, if the two components are mixed during preparation. STUDY DESIGN AND METHODS: S/D plasma was mixed with variously processed units of stored red cells, in vitro, to evaluate the effect the residual solvent and detergent would have on cell membrane integrity. A paired protocol design was used in which half-units of red cells were exposed to S/D plasma (test), and the matched half-units were exposed to either the supernatant additive solution from the original red cell unit or standard fresh-frozen plasma (FFP) (control). After incubation for up to 5 days, the units were evaluated for evidence of hemolysis or changes in other red cell storage assays. RESULTS: This study showed that, for fresh additive solution red cells (AS-1), the 5-day storage plasma hemoglobin levels were comparable in the red cells exposed to S/D plasma (21 mg/dL) and in the paired half-units stored in the original AS-1 supernatant (31 mg/dL) (p > 0.05). Similar findings were recorded for stored AS-1 red cells (S/D plasma; 111 mg/dL vs. AS-1 supernatant, 147 mg/dL; p > 0.05); stored CPDA-1 red cells (S/D plasma, 133 mg/dL vs. FFP, 103 mg/dL; p > 0.05); frozen red cells (S/D plasma, 28 mg/dL vs. FFP, 18 mg/dL; p > 0.017); and stored irradiated AS-1 red cells (S/D plasma, 608 mg/dL vs. AS-1 supernatant, 726 mg/dL; p > 0.05). Comparable results were found for other assays, including levels of plasma potassium, osmotic fragility, and red cell antigen titer. CONCLUSION: These data show that S/D plasma does not induce red cell lysis even after 5 days of in vitro storage. These results are consistent with previous findings by this laboratory that platelets are not harmed by storage in S/D plasma. Red cells resuspended in S/D plasma and stored for up to 5 days maintain in vitro storage characteristics that are acceptable for the use of the cells in clinical transfusion practice.

Blood Preservation↗

Effects of white cell reduction on the resistance of blood components to bacterial multiplication.

BACKGROUND: While prestorage white cell (WBC) reduction by filtration may improve platelet and red cell quality, it also may remove an important anti-bacterial defense mechanism, especially if blood is WBC-reduced shortly after collection. STUDY DESIGN AND METHODS: The question of whether WBC reduction of platelet concentrates and red cells altered bacterial proliferation kinetics in components prepared from deliberately contaminated, freshly collected blood was investigated. Two-unit pools of whole blood were inoculated, at a concentration of approximately one colony-forming unit per mL, with one of 17 bacterial species reported to have caused septicemia in transfusion recipients. Each pool was divided after inoculation, and components were prepared from the 2 units after a 7-hour room-temperature holding period. One unit of each AS-1 red cell or platelet pair was WBC-reduced, and the pairs were then stored for 42 days at 4 degrees C (red cells) or for 10 days at 22 degrees C (platelets). Quantitative bacterial cultures were performed at periodic intervals. RESULTS: In red cells, clinically significant bacterial proliferation occurred in only one instance (Serratia marcescens), and growth was less rapid in the WBC-reduced unit than in the control. Three patterns of growth were seen in platelet concentrates. In four cases, there was rapid proliferation in both test and control units, while on 13 occasions there was minimal replication in either pair. On six occasions, substantial growth was noted in control units, while few or no bacteria could be found in the WBC-reduced units. There was no evidence in either red cells or platelets that bacteria proliferated more rapidly in units that had been WBC-reduced before storage than they did in units in which WBCs were retained. CONCLUSION: Rather than increasing the risk of bacterial proliferation through removal of active phagocytic cells, WBC reduction by filtration before blood storage may act to reduce the likelihood of significant bacterial proliferation, possibly by removal of microorganisms along with WBCs.

Bacteria↗

Cytokine generation in stored platelet concentrates.

BACKGROUND: Cytokines, because of the nature of their immunoinflammatory actions, are potential mediators of the symptom complex of nonhemolytic transfusion reactions. One possible source of cytokines in the transfusion setting is the stored blood component itself. STUDY DESIGN AND METHODS: To test this possibility, the plasma portion of stored platelet concentrates (PCs) was assayed for the presence of interleukins 1 beta (IL-1 beta), 6 (IL-6), and 8 (IL-8) and tumor necrosis factor alpha (TNF-alpha). Samples were taken from PCs obtained from the inventory of a regional blood center (n = 120; 30 each of 2-, 3-, 4-, and 5-day-old units). RESULTS: Detectable levels of IL-8 were measured in 59 percent of the PCs sampled, ranging from 30 percent of the 2-day-old units to 83 percent of the 5-day-old units. The median IL-8 concentration ranged from undetectable levels in 2-day-old units up to 1100 pg per mL in 5-day-old units. The mean IL-8 concentration in 5-day-old units, 11,600 pg per mL, was 100 times the mean for 2-day-old units, which was 116 pg per mL (p < 0.0001). The highest levels of IL-8, 50,000 to 200,000 pg per mL, in general were found in units with the longest storage times and highest white cell counts. Sequential sampling of 17 individual PCs over 7 days of storage confirmed that IL-8 increases progressively with increasing storage time. Parallel, but smaller, increases in IL-1 beta were observed in those units with high IL-8 concentrations. TNF-alpha was detected in 3 (10%) of 30 five-day-old PCs, but never exceeded 55 pg per mL in any unit tested. IL-6 at levels of 740 and 508 pg per mL was detected in two 5-day-old units with high white cell counts of 9500 and 14,800 per microL, respectively, but not in 21 additional units tested with white cells < or = 9200 per microL or storage time of < or = 2 days. White cell reduction by third-generation filters on Day 1 of platelet storage prevented the generation of IL-8 and IL-1 beta to Day 5 of storage. CONCLUSION: Although IL-8 achieved levels in some units of PCs that appear capable of causing physiologic changes, the potential adverse effect on transfusion recipients of the infusion of cytokines in PCs remains to be investigated.

Blood Platelets↗

In vitro characteristics of white cell-reduced single-unit platelet concentrates stored in syringes.

BACKGROUND: Platelet concentrates (PCs) for premature infants may be subjected to filtration, centrifugation, and various storage conditions before transfusion. STUDY DESIGN AND METHODS: As there are few data on the cumulative effect of these procedures on PCs, platelet properties (including biochemical and functional in vitro assays) were evaluated after the processing of single units of PCs through a 1-unit-capacity high-efficiency white cell (WBC)-reduction filter followed by syringe storage at either 22 or 37 degrees C for 6 hours. Two- and 5-day-old PCs, volume-reduced PCs, and prestorage WBC-reduced PCs were evaluated. RESULTS: WBC filtration consistently resulted in a 3 to 4 log10 reduction in WBCs, with less than 15-percent platelet loss. No adverse effects of platelet function or evidence of increased platelet activation as determined by the percentage of P-selectin positivity were noted. A decrease in pH associated with increased lactate production and consumption of glucose was observed following syringe storage under all conditions tested. Such changes were most pronounced, however, with volume-reduced PCs stored at 37 degrees C (pH 6.31 +/- 0.15, lactate 23.0 +/- 3.06 mmol/L). All pH levels at the end of storage were above the minimum Food and Drug Administration requirement (pH 6.0). CONCLUSION: The in vitro data suggest that single units of PCs can undergo WBC filtration followed by syringe storage for up to 6 hours and still maintain acceptable storage characteristics. The practice of maintaining volume-reduced PCs in syringes for 6 hours at 37 degrees C in isolettes during transfusion should, however, be avoided.

Blood Component Removal↗

Activation in stored platelet concentrates: correlation between membrane expression of P-selectin, glycoprotein IIb/IIIa, and beta-thromboglobulin release.

By using two distinct measurements of alpha-degranulation (surface P-selectin [alpha-granule membrane protein-140] expression and beta-thromboglobulin [beta-TG] release) and quantitation of glycoprotein (GP) IIb/IIIa surface density, stored platelet concentrates were evaluated to determine a) which method of measuring platelet alpha-granule release was more sensitive in detecting early platelet activation; b) whether Day 1 levels of activation predicted the extent of activation or cell lysis on Day 5 of storage; and c) whether changes in surface GPIIb/IIIa density were primarily dependent on platelet activation. By using samples from paired and unpaired units stored for 1, 3, and 5 days, four observations could be made. 1) A flow cytometric assay for the percentage of P-selectin-positive platelets was more sensitive for early detection of platelet activation than was measurement of beta-TG release. This finding was most likely due to enhanced sensitivity in detecting platelets that had undergone partial alpha-granule release. 2) Total P-selectin expression correlated with beta-TG release, which indicated that the extent of alpha-granule membrane fusion with the external platelet membrane was proportional to the amount of alpha-granule contents released into the supernatant. 3) All of the activation measurements on Day 1 predicted the activation values, but did not predict the degree of cell lysis (measured by lactate dehydrogenase discharge), on Day 5 of storage. 4) Surface GPIIb/IIIa density was increased on the subset of P-selectin-positive platelets as compared with the P-selectin-negative subset at all times during storage, but, within each subset, GPIIb/IIIa surface density did not significantly increase over the time of storage.

Antigens, CD↗

The effect of solvent/detergent-treated plasma on stored platelet concentrates.

The treatment of fresh-frozen plasma (FFP) with a solvent/detergent (S/D) solution to inactivate contaminating viruses has been shown to be effective in reducing virus transmission while maintaining the hemostatic properties of the plasma. FFP is treated with tri(n-butyl)phosphate (solvent) and Triton X-100 (detergent) and then purified; the in vivo effect of the residual S/D has been reported to be minimal. In clinical transfusion practice, ABO-incompatible, HLA-matched, single-donor platelets may have to be resuspended in ABO-compatible plasma. The use of S/D-treated plasma for this purpose would remove the added risk of transfusion-transmitted diseases due to the use of another blood component. As there are no data on the use of S/D-treated plasma as a platelet-resuspending medium, the potential toxicity of the residual solvent and detergent on the in vitro function and integrity of platelets stored in S/D-treated plasma for 5 days was studied. A repeated-measures analysis of variance was used for statistical analysis. Results showed that, as compared to controls (non-S/D-treated plasma), platelets resuspended in S/D-treated plasma maintained their functional properties, including morphology score and osmotic recovery, for up to 5 days of storage (p > 0.05, NS). No significant changes were seen among S/D-treated plasma and control groups for platelet count, lactate dehydrogenase discharge, beta-thromboglobulin release, glucose utilization, or generation of lactate. Measurement of pO2 and pCO2 values showed some differences between S/D-treated plasma and control groups that were significant, but not clinically significant. The pH values for all four groups ranged from 7.1 to 7.4 on Day 5.(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance↗

In vitro changes in platelet function and metabolism following increasing doses of ultraviolet-B irradiation.

Ultraviolet-B (UV-B) irradiation of platelet concentrates (PCs) may prevent the development of posttransfusion HLA alloimmunization. This study evaluated the effect of increasing doses of UV-B radiation on stored PCs. Pooled PCs were irradiated at UV-B doses of 600, 2400 or 10,000 mJ per cm2 and stored up to 96 hours under standard blood bank conditions. Compared to nonirradiated room-temperature and 37 degrees C controls, the irradiated units showed no significant changes in platelet count, white cell count, discharge of lactate dehydrogenase, release of beta-thromboglobulin, metabolism of ATP, ADP, ammonia, glutamine, glutamate, hypoxanthine, pCO2, or pO2 at any time of storage following any of the three UV-B doses. However, after a dose of 10,000 mJ per cm2, there were significant decreases in in vitro assays of platelet function-specifically, osmotic recovery and morphology score. Some metabolic systems were also affected by the 10,000 mJ per cm2 radiation dose, as shown by a decline in pH and bicarbonate and an increase in glucose consumption and lactate production (p < 0.05). The changes in these latter assays appeared only after 96 hours of postirradiation storage. Such changes were not seen in either the room-temperature or 37 degrees C control groups. Thus, heat generated during irradiation, per se, did not appear responsible for the observed in vitro changes in platelet function and metabolism. On the basis of the assays analyzed, it is concluded that UV-B irradiation of PCs at doses up to 10,000 mJ per cm2 does not induce significant metabolic or functional derangements following short-term storage (24-48 hours).(ABSTRACT TRUNCATED AT 250 WORDS)

Adenosine Diphosphate↗

Stability of red cell antigens and plasma coagulation factors stored in a non-diethylhexyl phthalate-plasticized container.

Red cell antigen stability studies were performed to evaluate whether the storage of red cells in plastic segments made up of a new non-di-2(ethylhexyl)phthalate (DEHP)-plasticized material resulted in poststorage antigenic reactivity different from that seen in segments made from DEHP-containing plastic. Serial 1-in-2 dilutions of commercially available antisera were prepared and tested by using stored red cells obtained from segments on Days 0, 28, 42, and, in some instances, 49. Antigenic determinants tested included A, B, D, c, K, Le(a), Fya, Jka, M, and P1. To minimize variability, the same reagent lots were used throughout each study, and the same technologists performed the assays in each laboratory. No significant differences in titration scores were seen when cells stored in segments made of the test plastic were compared with cells obtained from the same donor and stored for the same length of time in segments made of control plastic. In addition, plasma coagulation factor stability was studied in fresh-frozen plasma and cryoprecipitate stored for up to 1 year in the non-DEHP-plasticized plastic containers. No significant differences were seen in prothrombin time, activated partial thromboplastin time, fibrinogen content, or factor V, VII, VIII, IX, or X activity as compared with plasma stored for equal periods of time in control plastic containers. It is concluded that the test plastic does not adversely affect red cell antigenic reactivity or plasma coagulation factor stability and that it is suitable for use in clinical transfusion practice.

Blood Coagulation Factors↗