Search PubMed⌕ Search

Biomedical subjects

E K Paulson

Publications and source records attributed to E K Paulson.

At least 19 recordsLinked to original sources

Acute cholecystitis: CT findings.

Some patients with acute cholecystitis may have symptoms suggestive of an abscess or other intra-abdominal inflammation and, therefore, may be referred for a CT of the abdomen. This report reviews the pathophysiology, clinical presentation, and CT findings of acute cholecystitis (gallstones, wall thickening, distention, pericholecystic fluid, and pericholecystic stranding). Pitfalls and complications of the diagnosis are discussed. Those scenarios where CT may prove superior to ultrasound or hepatobiliary scintigraphy are highlighted.

Acute Disease↗

Partial NMR assignments for uniformly (13C, 15N)-enriched BPTI in the solid state.

We demonstrate that high-resolution multidimensional solid state NMR methods can be used to correlate many backbone and side chain chemical shifts for hydrated micro-crystalline U-13C,15N Basic Pancreatic Trypsin Inhibitor (BPTI), using a field strength of 800 MHz for protons, magic angle sample spinning rates of 20 kHz and proton decoupling field strengths of 140 kHz. Results from two homonuclear transfer methods, radio frequency driven dipolar recoupling and spin diffusion, were compared. Typical 13C peak line widths are 0.5 ppm, resulting in Calpha-Cbeta and Calpha-CO regions that exhibit many resolved peaks. Two-dimensional carbon-carbon correlation spectra of BPTI have sufficient resolution to identify and correlate many of the spin systems associated with the amino acids. As a result, we have been able to assign a large number of the spin systems in this protein. The agreement between shifts measured in the solid state and those in solution is typically very good, although some shifts near the ion binding sites differ by at least 1.5 ppm. These studies were conducted with approximately 0.2 to 0.4 micromol of enriched material; the sensitivity of this method is apparently adequate for other biological systems as well.

Aprotinin↗

Pelvic CT morphometry in Down syndrome: implications for prenatal US evaluation--preliminary results.

PURPOSE: To characterize pelvic morphometric differences in patients with and those without Down syndrome by using computed tomography (CT) and to determine useful indexes for ultrasonographic (US) evaluation. MATERIALS AND METHODS: Pelvic CT scans in seven patients with Down syndrome and in 27 patients without Down syndrome were reviewed. Iliac angle, iliac length, sacroiliac joint angle, and anterior iliac wing separation were measured at superior, middle, and inferior transverse sacral levels. The effects of chromosomal status and transverse level were evaluated statistically. RESULTS: Significant differences were found for mean iliac angle (P < .007) and length (P < .005) between patients without Down syndrome (angle, 75 degrees; length, 8.4 cm) and those with Down syndrome (angle, 82 degrees; length, 7.5 cm). Depending on the level of measurement, variations in iliac angle between patients without and those with Down syndrome were as much as 13 degrees and 15 degrees, respectively, and variations in length were as much as 1.6 cm and 0.9 cm, respectively. The greatest differences were at the middle sacral level. Sacroiliac joint angle and the anterior iliac wing separation were not different between groups. CONCLUSION: Patients with Down syndrome had a larger mean iliac angle and a shorter mean iliac length. The most pronounced differences were at the middle sacral level, which suggests that this may be the optimal level for measuring these parameters at prenatal US.

Down Syndrome↗

Hepatic parenchymal enhancement during triple-phase helical CT: can it be used to predict which patients with breast cancer will develop hepatic metastases?

PURPOSE: To evaluate the efficacy of hepatic enhancement characteristics for identification of patients with breast cancer who are at risk for future hepatic metastases. MATERIALS AND METHODS: Triple-phase helical computed tomography (CT) was performed in 60 patients with known breast cancer without visible hepatic metastases. Peak hepatic attenuation and enhancement, and attenuation and enhancement at 25 and 30 seconds were obtained. Ratios of hepatic attenuation or enhancement at 25 and 30 seconds to peak hepatic attenuation or enhancement were calculated. A Wilcoxon rank sum test was used to compare patients with and those without subsequent hepatic metastases. RESULTS: During a mean 18-month follow-up, 18 patients (30%) developed hepatic metastases. Decreases in peak hepatic attenuation and enhancement and increases in hepatic attenuation and enhancement ratios at 25 and 30 seconds were seen in patients who developed metastases compared with those who did not (P < .05). When corrected for chemotherapy interval, these differences were not statistically significant. Using a threshold value of 0.40 or more for the enhancement ratio at 30 seconds resulted in sensitivity of 28%, specificity of 92%, and accuracy of 55%. CONCLUSION: Patients with breast cancer who develop subsequent hepatic metastases have higher relative hepatic arterial perfusion during triple-phase CT; however, after correction for chemotherapy interval, this difference was not statistically significant. Threshold values cannot be used reliably to identify patients who will develop metastases.

Adult↗

Treatment of iatrogenic femoral arterial pseudoaneurysms: comparison of US-guided thrombin injection with compression repair.

PURPOSE: To evaluate and compare the treatment of iatrogenic femoral arterial pseudoaneurysms by using ultrasonographically (US) guided direct thrombin injection with US-guided compression repair. MATERIALS AND METHODS: Twenty-six patients with iatrogenic femoral arterial pseudoaneurysms were treated with direct thrombin injection. With US guidance, a 22-gauge needle was placed into the pseudoaneurysm flow lumen and thrombin (mean volume, 0.35 mL; range, 0.10-0.60 mL) was injected with continuous color Doppler US guidance. Demographics, clinical variables, pseudoaneurysm characteristics, and results in these patients were compared with those in 281 consecutive patients who underwent US-guided compression repair. RESULTS: The success rate of thrombin injection was 96% (25 of 26 patients), which was significantly higher than that of compression, 74% (209 of 281 patients) (P =.013). Twenty of 26 (77%) patients required a single injection, and six (23%) required two injections. Mean thrombosis time for thrombin injection was 6 seconds, compared with 41.5 minutes for compression. For thrombin injection, there were no complications, foot pulses did not change and no patients required conscious sedation. Follow-up US at 24 hours showed no recurrent pseudoaneurysms. CONCLUSION: For the treatment of iatrogenic femoral arterial pseudoaneurysms, thrombin injection with US guidance appears to be superior to compression repair.

Aged↗

Nonenhanced helical CT and US in the emergency evaluation of patients with renal colic: prospective comparison.

PURPOSE: To compare nonenhanced helical computed tomography (CT) with ultrasonography (US) for the depiction of urolithiasis. MATERIALS AND METHODS: During 9 months, 45 patients (mean age, 44 years; mean weight, 92.5 kg) prospectively underwent both nonenhanced helical CT (5-mm collimation; pitch of 1.5) and US of the kidneys, ureters, and bladder. US evaluation included a careful search for ureteral calculi. Presence of calculi and obstruction and incidental diagnoses were recorded. Clinical, surgical, and/or imaging follow-up data were obtained in all patients. The McNemar test was used to compare groups. RESULTS: Diagnoses included 23 ureteral calculi and one each of renal cell carcinoma, appendicitis, ureteropelvic junction obstruction, renal subcapsular hematoma, cholelithiasis, medullary calcinosis, and myelolipoma. CT depicted 22 of 23 ureteral calculi (sensitivity, 96%). US depicted 14 of 23 ureteral calculi (sensitivity, 61%). Differences in sensitivity were statistically significant (P: =.02). Specificity for each technique was 100%. When modalities were compared for the detection of any clinically relevant abnormality (eg, unilateral hydronephrosis and/or urolithiasis in patients with an obstructing calculus), sensitivities of US and CT increased to 92% and 100%, respectively. One case of appendicitis was missed at US, whereas medullary calcinosis and myelolipoma were missed at CT. CONCLUSION: Nonenhanced CT has a higher sensitivity for the detection of ureteral calculi compared with US.

Adult↗

Helical CT cholangiography with three-dimensional volume rendering using an oral biliary contrast agent: feasibility of a novel technique.

OBJECTIVE: We evaluated the feasibility and image quality of a new noninvasive biliary imaging technique: helical CT cholangiography with three-dimensional volume rendering using an oral biliary contrast agent. SUBJECTS AND METHODS: Nineteen subjects including five healthy volunteers and 14 patients underwent helical CT cholangiography. Subjects ingested 6.0 g of iopanoic acid 6-10 hr before undergoing imaging. Axial data were used to construct three-dimensional volume-rendered cholangiograms. Two radiologists, an endoscopist, and a laparoscopic surgeon reviewed the images and evaluated overall image quality. In the 14 patients, findings from CT cholangiography were compared with those from ERCP, surgery, and intraoperative cholangiography. RESULTS: All segments of the biliary tree were opacified in all volunteers except one, in whom the intrahepatic ducts were not opacified. Image quality was good to excellent in all volunteers. Anomalous cystic duct insertions were seen in two volunteers. Opacification of the biliary tree was rated as acceptable to excellent in nine patients and suboptimal in five. In five patients with good or excellent opacification, the biliary anatomy correlated with findings on intraoperative cholangiography or ERCP. CT cholangiography revealed additional conditions (gallbladder varices and acute pancreatitis) and variant anatomy in three patients. CONCLUSION: Results of this pilot project suggest that obtaining CT cholangiograms using an oral biliary contrast agent is a feasible, noninvasive method for revealing biliary anatomy. However, visualization of the biliary tree was suboptimal in 36% of the patients, which represents a limitation of this technique.

Administration, Oral↗

Evaluation of pseudoenhancement of renal cysts during contrast-enhanced CT.

OBJECTIVE: The purpose of our study was to evaluate renal cyst pseudoenhancement during helical CT in a phantom model and in patients. MATERIALS AND METHODS: Iodine baths containing water-filled spheres and cylinders were constructed to simulate cysts in enhancing renal parenchyma. Iodine concentration, cyst size and location, collimation, and peak kilovoltage were varied and cyst attenuation was measured. Data were analyzed with the mixed linear models and Mantel-Haenszel tests. Subsequently, a paired t test compared CT attenuation values before and after contrast material enhancement in 40 patients with 68 renal cysts (radiographic stability >3 months). RESULTS: The attenuation values of phantom cysts increased when placed in a contrast media bath (p = 0.001). The increase in attenuation values became more pronounced with increasing iodine concentrations, decreasing peak kilovoltage, and smaller sphere sizes. In patients, mean cyst attenuation increased 3.4 +/- 6.2 H after administration of contrast material (p = 0.00002). The attenuation did not increase more than 10 H in any of the 37 cysts larger than 2 cm found in patients. Eight (26%) of the 31 cysts smaller than 2 cm found in patients increased by at least 10 H. CONCLUSION: In a phantom model, at simulated physiologic levels of renal enhancement, cysts may pseudoenhance by more than 10 H. Similarly, in patients, cysts may also pseudoenhance; however, most pseudoenhancement does not exceed 10 H. In patients, pseudoenhancement of at least 10 H is more likely in cysts smaller than 2 cm.

Humans↗

Comparison of sonographic and CT guidance techniques: does CT fluoroscopy decrease procedure time?

OBJECTIVE: Procedure times for percutaneous biopsies were compared for various guidance techniques including helical CT, CT fluoroscopy, sonography with an attached needle guide, and freehand sonography with computer guidance. MATERIALS AND METHODS: Three interventional radiologists experienced in CT- and sonographically guided procedures performed biopsies on a phantom model. The phantom simulated hepatic metastases of various sizes and depths with subcostal or intercostal locations. Lesion sizes were 7, 10, and 20 mm, at 3- and 7-cm depths. Using self-aspirating needles, two passes were performed in each lesion. Mean procedure time per biopsy pass was calculated. A two-tailed Student's t test was used to compare guidance techniques. RESULTS: Mean procedure time per biopsy pass for the four guidance techniques was sonography with a needle guide, 36+/-9 sec; sonography with computer guidance, 43+/-10 sec; helical CT, 146+/-42 sec; and CT fluoroscopy, 50+/-18 sec. CT fluoroscopy required 2.6+/-1.0 sec per biopsy. Helical CT required more procedure time than sonography with a needle guide, CT with computer guidance, and CT fluoroscopy (p < 0.0001). Sonography with a needle guide required less procedure time than sonography with computer guidance (p < 0.002) and CT fluoroscopy (p = 0.0003). Procedure times for CT fluoroscopy and sonography with computer guidance were not statistically different (p = 0.06). CT and sonographic guidance were equally effective regardless of lesion size, depth, or location. CONCLUSION: Traditional sonographic biopsy techniques are faster and more cost-effective than traditional CT techniques; however, CT fluoroscopy offers the localization advantages of CT with improved procedure times.

Abdomen↗

Transjugular intrahepatic portosystemic shunts (TIPS): effects of respiratory state and patient position on the measurement of Doppler velocities.

OBJECTIVE: The purpose of this prospective study was to examine the effects of patient position and respiratory state on the measurements of Doppler velocities in transjugular intrahepatic portosystemic shunts. SUBJECTS AND METHODS: Thirty-eight transjugular intrahepatic portosystemic shunts in 34 consecutive patients were studied using Doppler sonography. Peak velocities were measured in the mid shunt with the patient in three positions (supine, sitting upright, and left lateral decubitus) and two respiratory states (deep inspiration and quiet respiration). A mixed linear regression model was used to assess statistically significant differences among the six velocity measurements. RESULTS: Peak velocities in the mid stent averaged 22 cm/sec greater in quiet respiration than in deep inspiration, which was a significant difference (p < 0.00001). Differences in velocities in the three patient positions were not significant (p = 0.53). Using 90-190 cm/sec as the normal range, the peak velocity shifted from normal to abnormal levels by changing respiratory state in 17 (45%) of 38 studies. Using 60 cm/sec as the lower normal limit, the peak velocity fell below the normal range with inspiration in 10 (26%) of 38 studies. In 12 (32%) of 38 studies, a decline in peak velocity exceeding 50 cm/sec could be induced by inspiration. CONCLUSION: Peak systolic velocity in transjugular intrahepatic portosystemic shunts is substantially altered by the respiratory state of the patient at the time of the measurement, but not by the patient position. Respiratory state must be taken into account in the interpretation of peak velocity for shunt stenosis.

Adult↗

Detection of hepatic lesions in candidates for surgery: comparison of ferumoxides-enhanced MR imaging and dual-phase helical CT.

OBJECTIVE: The purpose of this study was to compare the use of phased array MR imaging of the liver at 1.5 T with and without ferumoxides with dual-phase helical CT for the detection of hepatic lesions in candidates for hepatic surgery. SUBJECTS AND METHODS: Patients with known or suspected hepatic lesions who were eligible for surgery underwent dual-phase helical CT at 20 and 70 sec after the start of contrast material injection and phased array MR imaging using fast spin-echo T2-weighted imaging and gradient-echo T1-weighted imaging before and after ferumoxides infusion of 0.56 mg of iron per kilogram of body weight. Three observers who were unaware of the surgical findings separately reviewed the CT scans and unenhanced and enhanced MR images of 24 patients who completed the protocol. The observers' findings were compared with results obtained at surgery using intraoperative sonography and having histopathologic confirmation. Statistical analysis was performed using a segment-by-segment analysis. RESULTS: Eighty-two lesions were found at surgery. The sensitivity of CT, unenhanced MR imaging, and enhanced MR imaging for blinded observers was 60.4%, 62.0%, and 68.2%, respectively. The specificity was 89.2%, 81.9%, and 81.6%, respectively. Five lesions in three patients were not detected preoperatively using any of the techniques. MR imaging found additional lesions not detected on CT in four patients; CT detected one additional lesion not seen on MR imaging. CONCLUSION: Ferumoxides-enhanced MR imaging of the liver shows a trend toward increased sensitivity compared with dual-phase helical CT. Specificity of helical CT was superior to that of enhanced MR imaging for most observers.

Case-Control Studies↗

Value of prone positioning in the ultrasonographic diagnosis of gallstones: prospective study.

To determine prospectively the value of prone/postprone positioning in the sonographic detection of gallstones, 682 patients were scanned in the recumbent, erect, and prone or postprone positions. The gallbladder was evaluated for an intraluminal hyperechoic focus, shadowing, and gravitational dependence and was identified in 679 patients. Among these, 28% had cholelithiasis. In five cases, prone positioning alone revealed gallstones. In 11 of 140 cases, gravitational dependence was only seen with prone scanning. The gallbladder was seen more frequently when the patients were prone than erect. Prone or postprone scanning is a useful supplement to the gallbladder examination, allowing increased demonstration of gravitational dependence and increased stone detection.

Adult↗

Fine-needle aspiration with flow cytometric immunophenotyping for primary diagnosis of intra-abdominal lymphomas.

Cytomorphology in conjunction with immunophenotypic characterization is becoming increasingly used for the primary diagnosis of non-Hodgkin's lymphomas (NHL). This combination is especially advantageous for the diagnosis of intra-abdominal and intrathoracic lymphomas, since unlike superficial lesions, open biopsy of deep-seated tissues is more invasive and more costly, and is associated with a higher risk. We report the cytologic and immunophenotypic features of intra-abdominal NHL obtained by fine-needle aspiration (FNA). Twenty-two cases of intra-abdominal lesions obtained by image-guided FNA where flow cytometry was also performed were reviewed. Of the 22 studied cases, 7 were classified as large-cell lymphoma, 5 as follicular center-cell lymphoma, 2 as small noncleaved-cell lymphoma, 2 as lymphoplasmacytoid lymphoma, one as small lymphocytic lymphoma, and one as marginal-zone lymphoma. In the remaining 4 cases where the immunophenotypic pattern was not definitive, the cytomorphologic features were of small cleaved cells in 3 cases and of mixed small cleaved and large cells in one case. We successfully classified 9 of the 10 patients on whom histologic confirmation was obtained. The successful primary classification of most intra-abdominal non-Hodgkin's lymphomas can be done with a combination of cytology and flow cytometry, and this can be the initial approach in patients with deep-seated lesions. Diagn. Cytopathol. 1999;21:98-104.

Abdominal Neoplasms↗

Imaging-guided percutaneous biopsy of focal splenic lesions: update on safety and effectiveness.

OBJECTIVE: The purpose of this study is to determine the safety and effectiveness of percutaneous imaging-guided biopsy in the diagnosis of focal splenic lesions. MATERIALS AND METHODS: From May 1995 to November 1997, 20 imaging-guided biopsies of focal splenic lesions were performed in 18 patients, including seven patients with a prior diagnosis of extrasplenic malignancy (breast cancer, n = 3; lymphoma, n = 2; ovarian cancer, n = 1; and osteogenic sarcoma, n = 1), three immunosuppressed patients (cause of immunosuppression: AIDS, n = 1; liver transplantation, n = 1; and bone marrow transplantation, n = 1), two patients with anemia, one patient with a recent history of IV drug abuse, and five patients with incidentally discovered splenic lesions. Biopsies were performed with an 18-gauge (n = 1), a 20-gauge (n = 8), or a 22-gauge (n = 14) self-aspirating needle or an 18-gauge cutting needle (n = 1). Biopsies were considered successful if a specific diagnosis of benign or malignant disease was made. RESULTS: A specific diagnosis was made in 16 (88.9%) of 18 patients, and no complications occurred. Malignancy was diagnosed in six patients including three patients with lymphoma. Benign conditions were diagnosed in 10 patients: a cyst in two patients; hamartoma in one; lipogranuloma in one; infarct in one; and infection in four, including one case each of Candida albicans, Pneumocystis carinii, Mycobacterium tuberculosis, and mixed flora. The tenth benign diagnosis was a pseudotumor of the spleen related to a bulbous tail of the pancreas that was inseparable from the splenic hilum. Biopsy did not establish a diagnosis in one patient with lymphoma and in one patient with presumed splenic candidiasis. A mean of 1.5 needle passes was made per biopsy. CONCLUSION: Imaging-guided splenic biopsy is a safe technique that provides a specific diagnosis in most patients with focal splenic lesions.

Adult↗