Search PubMed⌕ Search

Biomedical subjects

E J Swift

Publications and source records attributed to E J Swift.

At least 37 records · Page 2Linked to original sources

Dentin bonding: what is the state of the art?

Currently, two approaches are available for bonding resin-based materials to dentin--total-etch and self-etch. The total-etch approach, using either a three-step or a two-step method, has been available for several years. Clinical studies have demonstrated excellent success rates for total-etch adhesives, but many clinicians report problems with postoperative sensitivity. The self-etch approach, which is relatively new to the US market, reduces the incidence of postoperative sensitivity. However, the long-term clinical performance of self-etch materials--particularly those that use a single solution to etch, prime, and bond--is not yet proven. This article provides an overview of the current options for bonding resin to dentin.

Acid Etching, Dental↗

Effects of adhesive composition on microtensile bond strength to human dentin.

PURPOSE: To evaluate the role of adhesive composition (solvent and filler content) on microtensile bond strength (muTBS) to human dentin. MATERIALS AND METHODS: 15 third molars were ground to expose superficial dentin, which was polished to 600-grit. The dentin was etched for 15 s with 37.5% phosphoric acid, rinsed, and blotted with tissue paper. The surface remained visibly moist for all specimens. The following adhesives were applied to the etched dentin according to manufacturers' directions: Single Bond (SB), experimental Single Bond (with filler) (ExpSB), Prime & Bond NT (NT), experimental Prime & Bond NT (without nanofiller) (ExpNT), and One Coat Bond (with filler) (OC). Each adhesive was applied to three teeth, and a cylinder of resin-based composite was built up on the occlusal surface. After 24-hour water storage, each tooth was vertically sectioned with a low-speed saw to produce a series of 0.7 mm slabs. Each slab was then sectioned to obtain "sticks" with a cross-sectional area ranging from 0.35 to 0.45 mm2. muTBS were determined using an Instron universal testing machine. Data were analyzed using one-way ANOVA, and Duncan's test. RESULTS: For filled adhesives, mean bond strengths ranged from 57.9 MPa for ExpSB to 48.2 MPa for NT. The unfilled adhesives SB and ExpNT had mean bond strengths of 75.9 MPa and 38.7 MPa, respectively. Unfilled SB had a significantly higher mean bond strength than the experimental filled version. The ethanol-based adhesive SB had a significantly higher mean bond strength than either the nonvolatile solvent-based OC or the acetone-based NT.

Acetone↗

Effect of finishing technique on the microleakage and surface texture of resin-modified glass ionomer restorative materials.

PURPOSE: The purpose of this study was to evaluate the effects of wet and dry finishing/polishing procedures on the microleakage and surface texture of resin-modified glass ionomer (RMGI) restorative materials. MATERIALS AND METHODS: Class V cavity preparations were made at the cemento-enamel junction (CEJ) on the buccal and lingual surface of 30 extracted human molars. The teeth were restored in three groups of 10 (20 preparations in each group) using Fuji II LC and Vitremer, both RMGIs, and Fuji II, a capsulated conventional glass ionomer cement (control). One restoration per tooth was finished/polished with copious applications of water and the other was finished/polished without water. All restorations were finished/polished using a sequence of four abrasive disks. Finishing/polishing was initiated according to manufacturers' instructions-immediately after light-curing Fuji II LC and Vitremer, and 15min after placement for Fuji II. The specimens were thermocycled and subjected to a silver nitrate leakage test. Each tooth was sectioned buccolingually and examined with an optical microscope at 40x to determine the extent of microleakage at enamel and dentin margins. The data were subjected to a non-parametric statistical analysis. To evaluate surface roughness after polishing, three disks each of Vitremer and Fuji II LC were fabricated in Teflon molds. One disk of each material was not finished/polished (control). The others were finished/polished using Sof-Lex abrasive disks. One specimen of each material was kept wet during all finishing/polishing procedures, while the other was kept dry. Atomic force microscopy was used to determine the average roughness (R(a)) of the specimens. RESULTS: For each material, microleakage at the enamel margin was very slight. Leakage of the conventional glass ionomer Fuji II was severe at dentin margins. Statistical analysis indicated that both Vitremer and Fuji II LC had significantly less leakage than Fuji II, and that Vitremer had significantly less leakage than Fuji II LC (p<0.05). Leakage at enamel margins was significantly less than at dentin margins. Differences related to wet and dry polishing were not statistically significant. Profilometry data indicated that polished specimens were rougher than those cured against a Mylar strip. Wet polishing created greater surface roughness than dry polishing. CONCLUSIONS: RMGIs rather than conventional glass ionomers should be used in Class V cavity sites to allow immediate finishing and to reduce the incidence of microleakage. Dry finishing of RMGIs with abrasive disks is recommended because it produces a smoother surface and does not contribute to microleakage. However, wet finishing of conventional glass ionomers is still recommended to avoid desiccation.

Composite Resins↗

Effects of different re-wetting techniques on dentin shear bond strengths.

PURPOSE: For contemporary hydrophilic resin adhesive systems, bonding to dentin is improved if the substrate is maintained in a hydrated state following acid-etching. The purpose of this study was to compare the dentin shear bond strengths of two single-bottle adhesives (one acetone-based and one ethanol-based) applied under different etched-dentin conditions: dry, wet, or dry and re-wetted with different solutions. MATERIALS AND METHODS: Bovine incisors (N = 120) were mounted in acrylic, polished to 600-grit, and randomly assigned to 12 groups (n = 10). Dentin was etched for 15 seconds using 35% phosphoric acid, rinsed, and either blot-dried, air-dried, or air-dried and re-wetted with different solutions (distilled water, Gluma Desensitizer, Aqua-Prep, and 5% glutaraldehyde in water). Two adhesives (Single Bond and Prime & Bond NT) were applied to each of the surface conditions following manufacturers' instructions. After adhesive application and curing, composite was applied in a No. 5 gelatin capsule and light-cured. Specimens were loaded in shear, using an Instron at 5 mm per minute. Shear bond strengths were calculated by dividing the failure load by the bonded surface area. Data were subjected to analysis of variance (ANOVA) and a post hoc Tukey test. RESULTS: Mean shear bond strengths ranged from 12.5 to 26.6 MPa for Single Bond and from 5.6 to 14.7 MPa for Prime & Bond NT. Significant differences were found in both groups of materials (p < .001). The three highest mean bond strengths were obtained (in order) on dentin that was re-wetted with Gluma Desensitizer, re-wetted with Aqua-Prep, or never dried. Differences between these surface conditions were not statistically significant for either material.

Acetone↗

Shear bond strengths of one-bottle adhesives to oil-contaminated enamel.

PURPOSE: To evaluate resin bond strength to enamel contaminated with handpiece oil. MATERIALS AND METHODS: Bovine teeth were randomly assigned to six groups of 20 teeth each for treatment with one of six different bonding systems (five one-bottle and one multibottle). For each system, 10 enamel specimens were contaminated with handpiece oil before acid-etching and 10 were contaminated after acid-etching. The enamel was etched for 15 seconds using 35% phosphoric acid. Following adhesive application, composite resin was bonded using a gelatin capsule technique. Shear bond strengths from the two contaminated groups were compared to bond strengths to uncontaminated enamel obtained from a previous study that was performed by the same group of investigators, using the same facility, materials, and methods. RESULTS: Two-way analysis of variance (ANOVA) showed that the factor "surface contamination" did not have a significant effect on bond strength (p > .542). The type of adhesive and the interaction of adhesive and surface contamination were significant (p < .0001 and p < .003, respectively). When oil was applied before etching, mean bond strengths ranged from 18.0 +/- 4.8 MPa for OptiBond SOLO (Kerr Corp., Orange, California) to 25.3 +/- 5.6 MPa for Tenure Quik with Fluoride (Den-Mat Corp., Santa Maria, California). With oil applied after etching, bond strengths ranged from 18.4 +/- 8.0 MPa for Tenure Quik with Fluoride to 27.4 +/- 5.4 MPa for Single Bond (3M Dental Products, St. Paul, Minnesota). For the same adhesive, comparing uncontaminated and "oil-before-etch" contaminated groups, the only statistically significant difference in bond strengths was for OptiBond SOLO: 21.8 +/- 4.0 MPa (uncontaminated) versus 18.0 +/- 4.8 MPa (oil before etch). Comparing uncontaminated and "oil-after-etch" groups, the only statistically significant difference was for Tenure: 24.5 +/- 5.7 MPa (uncontaminated) and 18.4 +/- 8.0 MPa (oil after etch).

Analysis of Variance↗

Medium-viscosity polyether impression material: a case report.

Polyethers are elastomeric materials commonly used for making precision impressions. They are hydrophilic, which facilitates the contact of the unset material with the intraoral tissue and the wetting of the impression by cast materials. The final hardness of this new impression material is reduced in an attempt to overcome rigidity of the set impression. A case is described involving the restoration of a fractured maxillary premolar and a single-phase impression technique using the new polyether impression material.

Bicuspid↗

Two-year clinical evaluation of tooth whitening using an at-home bleaching system.

PURPOSE: The purpose of this study was to evaluate the 2-year effectiveness of a carbamide peroxide at-home bleaching gel used to provide tooth lightening treatment. MATERIAL AND METHODS: Twenty-nine patients participated in the original study, during which they treated their maxillary teeth with a 10% carbamide peroxide gel nightly for 2 weeks. Shades were determined before and after treatment by comparison with a Vita shade guide. Twenty-four patients (a recall rate of 83%) were recalled for evaluation 2 years after the initial bleaching treatment. The shade of the maxillary incisors was evaluated and compared with shades before, immediately after, and at 6 months and 2 years after initial treatment. Data were analyzed using a repeated-measures analysis of variance. RESULTS: At 2 years after bleaching with a 10% carbamide peroxide gel, the median shade was D2, a six-increment difference from the baseline median of D3. Twenty of 24 patients (83.3%) had a shade change of two or more units, which is the threshold value for bleaching efficacy using American Dental Association guidelines. The lightening result remained statistically significant (p < .0001) at 2 years. CLINICAL SIGNIFICANCE: Although some reversal of the lightening effect occurs over time following the original bleaching treatment, loss of the lighter color appears to be gradual for most patients. Although the longevity of the lightening effect remains to be determined, this clinical trial indicates that the majority of patients have a satisfactory result 2 years after treatment.

Adult↗

Shear bond strengths of one-bottle adhesives to moist enamel.

PURPOSE: This study evaluated bond strengths of six one-bottle bonding agents and a control (primer plus unfilled resin) to moist enamel. MATERIALS AND METHODS: One-hundred and five bovine teeth were randomly assigned to seven groups of 15. Enamel was etched for 15 seconds with 35% phosphoric acid. Etched enamel was rinsed, and excess water was blotted with tissue paper. Following application of the adhesive, composite resin was bonded using a gelatin capsule technique. Shear bond strengths to enamel were determined using a universal testing machine (Instron Corp., Canton, Massachusetts). RESULTS: Mean bond strengths ranged from 21.9 MPa for OptiBond Solo (Kerr Corp., Orange, California) to 29.6 MPa for Prime & Bond 2.1 (Dentsply/Caulk, Milford, Delaware). Prime & Bond 2.1 had a significantly higher mean bond strength than the other adhesives. CLINICAL SIGNIFICANCE: The results of this study suggest that all of the one-bottle systems tested should provide clinically acceptable bonding to moist enamel.

Animals↗

Packable composites: overview and technical considerations.

OBJECTIVE: New composites, called packable or condensable composites, are being promoted as amalgam alternatives. The purposes of this review article are to identify these products, define new terminology associated with them, summarize the advertised properties for the materials, discuss the ideal properties for packable composites, review the properties of the major products, and critically evaluate the proposed handling procedures for these materials. REVIEW: The term packable is preferable to condensable for describing this new class of materials. All materials should be considered amalgam alternatives, not amalgam substitutes. The compositions and physical properties reported by manufacturers reveal that none of the materials represents a remarkable improvement over the properties of more traditional universal composites. The designs of Solitaire (Heraeus Kulzer), ALERT (Jeneric-Pentron), and SureFil (Dentsply/Caulk) are discussed in detail. The distinguishing characteristics of all packable compositions are less stickiness or stiffer viscosity than conventional composites, which allow them to be placed in a manner that somewhat resembles amalgam placement. CONCLUSIONS: Packable composites may allow more convenient placement in posterior sites and may offer some technique advantages over conventional composites. However, there is no evidence that their clinical properties are consistently better than those of conventional universal composites. CLINICAL SIGNIFICANCE: Packable composites may be selected as alternatives to amalgam or conventional universal composites, but they are not equal to or better than dental amalgam in all respects. Also, in most cases, mechanical properties of packable composites are not substantially better than those of most conventional universal composites.

Composite Resins↗

Fluoride release from restorative materials and its effects on dentin demineralization.

As the use of adhesive restorative materials has increased during the last several years, interest in adhesive materials that release fluoride has also grown. The purpose of this study was to measure fluoride release from several adhesive restorative materials and to evaluate its effect on dentin resistance to demineralization and on bacterial metabolism in a modified in vitro system. Standardized cavities (1.8 mm in diameter) were prepared in bovine teeth that had been ground to dentin. One cavity in each tooth was restored with one of the following restorative systems: (a) Single Bond and Z100; (b) Single Bond and Tetric Ceram; (c) Fuji Bond LC and Z100; (d) Fuji Bond LC and Tetric Ceram; (e) Fuji II LC; or (f) Fuji IX GP. The other cavity in each tooth was "restored" with wax as a control. For each restorative system, 12 specimens were evaluated for fluoride release during the first 24 hrs after restoration placement. Dentin adjacent to the restored sites was subjected to lactic acid challenge (pH 4.3) for 3 hrs, after which calcium release was measured. Another 12 specimens in each group were stored for 24 hrs in de-ionized water, and were exposed to an S. mutans suspension (1:1 THB/de-ionized water and 50 mM glucose, A660 = 0.2) for 6 hrs, followed by calcium release and pH measurement. Bulk specimens of each material were also made and stored in water. Fluoride released from Fuji Bond LC, Fuji IX GP, and Fuji II LC in bulk was significantly greater than from the other materials. In the restored dentin specimens, increased resistance to demineralization from a lactic acid challenge was directly related to fluoride release. The same effects were seen as a result of the S. mutans challenge. While fluoride release from restorative materials increased the resistance of dentin to demineralization in this system, the clinical relevance of the findings is not known.

Animals↗

Treatment options for the exposed vital pulp.

The exposure of dental pulp generally occurs as the result of accidental trauma or preparation techniques utilized during the restoration of carious lesions. While frank carious exposures are optimally treated with pulpectomy and root canal therapy, the ideal treatment of mechanically exposed pulps has remained controversial. This article describes the indications, clinical techniques, and prognosis for direct pulp capping and partial pulpotomy.

Anti-Infective Agents, Local↗

Effects of repeated use on bond strengths of one-bottle adhesives.

OBJECTIVE: Most one-bottle adhesives contain organic solvents (acetone or ethanol) that displace the water entrapped within the network of collagen fibers in etched dentin. Acetone and ethanol are volatile substances that could easily evaporate from bottles during use. The objective of this in vitro study was to assess the effects of repeated opening of bottles on dentin shear bond strengths of 4 adhesives. METHOD AND MATERIALS: Eighty freshly extracted bovine incisors were mounted, polished to 600 grit, and randomly assigned to 8 groups (n = 10). After the application of the materials to 40 specimens at baseline, adhesive use was simulated by opening bottles for 1 minute, 2 times a day, for 3 weeks, except during weekends, when the bottles were kept refrigerated. After 3 weeks of simulated use, the same adhesives were applied to 40 additional specimens. Resin composite was applied to dentin in a No. 5 gelatin capsule and was light-cured. After 500 thermal cycles (5 degrees C to 55 degrees C), shear bond strength testing was performed with a universal testing machine at 0.5 cm/min. RESULTS: Adhesives containing ethanol or water had similar mean bond strengths at baseline and at 3 weeks. The acetone-based material had a significantly lower mean bond strength at 3 weeks than at baseline. CONCLUSION: Acetone-based adhesives may have a shorter useful life than ethanol- and water-based adhesives.

Acetone↗

Bond strengths of new simplified dentin-enamel adhesives.

PURPOSE: To compare the in vitro shear bond strengths (SBS) of five simplified dentin adhesives. The tested hypothesis was that the recently introduced simplified adhesive systems would have similar or higher SBS than an existing simplified acetone-based adhesive used as a control. MATERIALS AND METHODS: 100 flat bonding sites were polished to 600-grit on the labial surface of bovine incisors mounted in acrylic resin. 50 teeth were ground to expose enamel, while the remaining 50 specimens were prepared to expose middle dentin. The specimens were randomly divided into five equal groups to be treated with simplified dentin adhesives: Dentastic Uno, EasyBond, Gluma One Bond, One Coat Bond, and One-Step (control). A composite post was bonded to each treatment area. After thermo-cycling, enamel and dentin shear bond strengths were determined using an Instron testing machine and the data were submitted to statistical analyses. RESULTS: Mean enamel bond strengths ranged from 14.6-28.4 MPa. One Coat Bond had the highest mean enamel SBS, but it was not significantly higher than those of Gluma One Bond and Dentastic Uno. EasyBond and One-Step had statistically similar mean enamel SBS and these were significantly lower than the mean enamel SBS of the other three adhesives. For dentin, mean SBS ranged from 14.8-21.7 MPa. Dentastic Uno had the highest mean dentin SBS, but it was not significantly greater than those of One Coat Bond and Gluma One Bond. Although One Step had the lowest mean dentin SBS, it was not significantly different from those of either EasyBond or Gluma One Bond.

Analysis of Variance↗

A prospective clinical evaluation of electronically mixed polyvinyl siloxane impression materials: results from the prosthetic "SuperStudy"--a consumer evaluation.

Polyvinyl siloxane (PVS) impression materials incorporating a polyether carbosilane wetting agent and mixed with an electronic mixing system (Pentamix) were clinically compared with traditionally delivered (i.e., automixed) PVS impression materials during routine use by 1,505 general and specialized dental practitioners evaluating more than 30,000 impressions. Each study participant selected 20 patients and used standard tooth-preparation procedures appropriate to the therapy required, supplied specific data on each case, and ultimately evaluated the marginal detail, fit, and success of the final restorations. The areas requiring evaluation upon completion of the final restorations were ranked between "excellent," "good," "poor," and "remake needed," among users of the PVS materials with the electronic mixing system. About 80% of the respondents rated the Pentamix system as easier to mix and deliver than the gun or hand-mixed systems and two thirds said it was faster to mix. The system also received high scores for hygienic delivery, ease of mixing, and clean-up.

Consumer Behavior↗

Effect of polymerization mode on bond strengths of resin adhesive/cement systems.

PURPOSE: The purpose of this study was to examine the effect of resin adhesive/cement system primer and cement polymerization mode (auto- vs dual-polymerized) on the shear bond strength to dentin. MATERIALS AND METHODS: Dentin surfaces of 90 bovine teeth were polished to 600 grit. The dentin was etched for 15 seconds with phosphoric acid, rinsed, and blotted. Three adhesive systems, All-Bond 2, Prime & Bond 2.1 Dual-Cure, or Scotchbond Multi-Purpose Plus, were applied. Three primer polymerization methods were used with each system: dual-polymerized, autopolymerized, or strictly following manufacturers' recommendations. Resin cements, which were also either auto- or dual-polymerized, were applied to dentin using gelatin capsules. Shear bond strengths were determined using an Instron universal testing machine. RESULTS: The greatest bond strength, 15.4 MPa, was found with the Scotchbond system when the primer was dual-polymerized and the cement was autopolymerized. The lowest bond strength, 7.5 MPa, was found with All-Bond 2/Duo-Link, when the primer and cement were dual-polymerized. The autopolymerization mode produced the highest mean bond strength for All-Bond 2, while dual-polymerization of primer and cement resulted in the highest mean bond strength for Prime & Bond 2.1. Scotchbond Multi-Purpose Plus was least affected by the polymerization method. Two-way ANOVA showed that the interaction between the type of adhesive system and the method of polymerization significantly influenced bond strength (p = .0001). CONCLUSIONS: The effect of the primer polymerization method on ultimate bond strength was different for each adhesive system evaluated. More research is needed to elucidate the interaction between adhesive system and method of polymerization on bonding of resin cements to dentin.

Animals↗

A characterization of first-generation flowable composites.

A plethora of new low-viscosity composite resin materials, or flowable composites, have been marketed during the last two years, but little has been published about them. The authors describe research in which they compared the properties--filler, depth or cure, flow, wear, compressive strength, diametral tensile strength, indented biaxial flexure strength and toughness--of flowable and hybrid composites. Mechanical property tests (ISO 4049, ISO/DIS 6872) of eight flowable composites and two hybrid composites were conducted. The flowable composite with the least flow was similar to traditional composites. Mechanical properties were generally about 60 to 90 percent of those of conventional composites. The authors conclude that flowable materials should be used with caution in high-stress applications for restorative dentistry.

Chemical Phenomena↗