Comparison of two radioimmunoassay kits for aldosterone determination.

Two commercially available radioimmunoassay kits for aldosterone determination not requiring preliminary chromatographic purification were examined. Aldosterone standard curve solutions prepared from the CIS kit, Nuclear International Corp., (x-axis) and Diagnostic Products kit (y-axis) were assayed with both kits and the results yielded a regression equation of y = 0.834x + 0.08 nmol/liter. Analytical recovery experiments with aldosterone added to urine and serum showed 120% and 101% recovery with the CIS kit, respectively, and 92% and 92% recovery with the Diagnostic Products kit, respectively. Both kits demonstrated good parallelism with urine and serum. Antibody specificity was tested with six structurally related steroids and each kit showed virtually no cross-reactivity at clinically normal serum concentrations. Serum aldosterone values were compared before (y-axis) and after (x-axis) column chromatography on Sephadex LH-20, with the following regression equations: y = 1.070x + 0.092 nmol/liter for the CIS kit and y = 1.023x + 0.093 nmol/liter for the Diagnostic Products kit. Regression equations comparing patient samples between kits, CIS (x-axis) and Diagnostic Products (y-axis), were: y = 0.832x + 0.007 mumol/24 h with urine and y = 0.850x + 0.097 nmol/liter with serum.

Aldosterone↗

Comparison of results for 13 clinical laboratory determinations with three automated analytical systems.

We evaluated the Abbott Bichromatic Analyzer-100 (ABA-100) for use in the routine clinical chemistry laboratory by examining 13 different determinations that can be performed on the instrument. Results with the Du Pont "aca" and Technicon continuous-flow systems were compared to the ABA-100 in terms of upper limits of linearity, inter-run coefficient of variation, and results for samples from patients. The upper limits of linearity for the methods on the ABA-100 exceeded all of those for the continuous-flow systems, except for urea nitrogen. Precision of the ABA-100 was as good as or better than that of the aca for all determinations, except for glucose in a normal control serum and creatine kinase and creatinine in an above-normal control serum.

Alanine Transaminase↗

Faster enzymatic procedure for serum triglycerides.

We describe a single-reagent, enzymatic procedure for triglycerides in serum, which may be performed in 5 min per sample with use of an Abbott ABA-100 analyzer system. This procedure is compared to the semi-automated enzymatic procedure with the ABA-100, which requires 30 min per sample.

Autoanalysis↗

Analysis of benzoylecgonine in dried blood spots by liquid chromatography--atmospheric pressure chemical ionization tandem mass spectrometry.

Residual samples from blood spots (i.e., whole blood spotted onto filter paper) are a useful source for epidemiological screening studies involving newborns. However, the small volume of blood available from residual blood spots complicates the assay. A method for analyzing benzoylecgonine (BZE; the primary metabolite of cocaine) in blood spots, in which the blood spot is eluted with aqueous ammonium acetate-methanol containing N-methyl trideuterated-BZE as an internal standard, followed by high-performance liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry using multiple reaction monitoring, has been developed. This approach provides a rapid, direct, sensitive (limit of detection, approximately 2 ng/mL, based on a 12-microL sample size), and highly specific means of determining BZE concentrations in blood spots. We have applied this method for confirmatory analyses in a large epidemiological study of the prevalence of cocaine use during late pregnancy.

Acetates↗

Strategies for biological monitoring of exposure for contemporary-use pesticides.

Pesticides are used on a massive scale in the United States. The widespread use of these pesticides has made it virtually impossible for the average person to avoid exposure at some level. Generally, it is believed that low-level exposure to these pesticides does not produce acute toxic effects; however, various cancers and other noncancer health endpoints have been associated with chronic exposure to several groups of pesticides. Therefore, it is imperative that well-designed studies investigate the potential relationship between contemporary pesticide exposure and health effects. For these studies to be accurate, reliable methods for determining individual exposure must be used. Biological monitoring is a useful tool for assessing exposure to some contemporary pesticides. As with any analytical method, biological monitoring entails many difficulties, but, in many instances, they can be overcome by the logical use of available information and information acquired in carefully designed studies. At the Centers for Disease Control and Prevention (CDC), we have acquired extensive experience in the development and application of specific techniques for biological monitoring of a variety of toxicants, including many of the contemporary-use pesticides. We have used these methods to measure the internal dose of pesticides received by people in acute and chronic incidents resulting from both environmental and industrial exposure. Additionally, we have established normative values, or reference ranges, of several pesticides based on measurements of their metabolites in the urine of randomly selected adults in the US population. These data have been successfully used to distinguish overt exposures from 'background' exposure. In this paper, we present several examples of the usefulness of biological monitoring in urine and blood and describe the difficulties involved with developing methods in these matrices. We also present a general strategy, considerations, and recommendations for developing biological monitoring techniques for measuring the internal dose of contemporary-use pesticides.

Adult↗

Serum dioxin levels in Seveso, Italy, population in 1976.

On July 10, 1976, an explosion at a chemical plant near Seveso, Italy, released a mixture of chemicals, including 2,3,7,8-tetrachlorodibenzo-p-dioxin and 2,4,5-trichlorophenol. As a result, several thousand people in the Seveso area may have been exposed to those chemicals. At that time, human exposure assessment was based primarily on soil levels of 2,3,7,8-tetrachlorodibenzo-p-dioxin. Medical examinations of this potentially exposed population and control subjects were begun in 1976 and in some cases continued until 1985. In 1988, we began assessing human exposure in this population by measuring 2,3,7,8-tetrachlorodibenzo-p-dioxin in small volumes of serum specimens remaining from the medical examinations. As expected, we found that the median serum dioxin levels were highest among people who lived closest to the explosion and were progressively lower among groups living farther away. These measurements have allowed us to assess exposure more accurately among individuals in this population and to relate exposure to various health effects. We found that some individuals in the exposed population had among the highest serum dioxin levels ever reported, yet chloracne was the only unequivocal effect found; cancer risks are still being investigated. We also found that other individuals with as high or higher serum dioxin levels did not develop chloracne. We also found that the serum half-life of dioxin in this population was 7-8 years, which agrees with other findings although we do report some differences in the serum half-life of TCDD for women and children. We also observed an increase in the percentage of female newborns to parents who resided in Zone A at the time of the explosion, and we also report on the 1976 serum dioxin levels in people who later developed cancer.

Accidents↗