Search PubMed⌕ Search

Biomedical subjects

E J Sampson

Publications and source records attributed to E J Sampson.

At least 37 records · Page 2Linked to original sources

Pesticide residues in urine of adults living in the United States: reference range concentrations.

We measured 12 analytes in urine of 1000 adults living in the United States to establish reference range concentrations for pesticide residues. We frequently found six of these analytes: 2,5-dichlorophenol (in 98% of adults); 2,4-dichlorophenol (in 64%); 1-naphthol (in 86%); 2-naphthol (in 81%); 3,5,6- trichloro-2-pyridinol (in 82%); and pentachlorophenol (in 64%). The 95th percentile concentration (95th PC) for 2,5-dichlorophenol (indicative of p-dichlorobenzene exposure) was 790 micrograms/liter; concentrations ranged up to 8700 micrograms/liter. 2,4-Dichlorophenol concentrations ranged up to 450 micrograms/ liter, and the 95thPC was 64 micrograms/liter. 1-Naphthol and 2-naphthol (indicative of naphthalene exposure) had 95thPCs of 43 and 30 micrograms/liter, respectively; concentrations of 1-naphthol ranged up to 2500 micrograms/liter. Chlorpyrifos exposure was indicated by 3,5,6-tricholoro-2-pyridinol concentrations of 13 (95thPC) and 77 micrograms/liter (maximum observed). Pentachlorophenol had a 95thPC of 8.2 micrograms/liter. Other analytes measured included 4-nitrophenol (in 41%); 2,4,5-trichlorophenol (in 20%); 2,4,6-trichlorophenol (in 9.5%); 2,4-dichlorophenoxyacetic acid (in 12%); 2-isopropoxyphenol (in 6.8%); and 7-carbofuranphenol (in 1.5%). The 95thPCs of these analytes were < 6 micrograms/liter. p-Dichlorobenzene exposure is ubiquitous; naphthalene and chlorpyrifos are also major sources of pesticide exposure. Exposure to chlorpyrifos appears to be increasing. Although pentachlorophenol exposure is frequent, exposure appears to be decreasing. These reference range concentrations provide information about pesticide exposure and serve as a basis against which to compare concentrations in subjects who may have been exposed to pesticides.

2,4-Dichlorophenoxyacetic Acid↗

Using biological monitoring to assess human exposure to priority toxicants.

Scientifically valid exposure assessment is crucial to risk assessment, risk management, and prevention of environmental disease. Scientists have used three tools to assess exposure: exposure history/questionnaire, environmental monitoring (including personal monitoring), and biological monitoring. Combinations of these tools usually provide the exposure information needed to meet objectives of human studies evaluating the exposure-health effect relationship. Biological monitoring is a capable exposure assessment tool that has provided important information used in public health decisions. We briefly describe how risk assessment and risk management decisions for lead, dioxin, and volatile organic compounds have substantially benefited from exposure information obtained from biological monitoring.

Dioxins↗

The priority toxicant reference range study: interim report.

The relationship between human exposure to environmental toxicants and health effects is of utmost interest to public health scientists. To define this relationship, these scientists need accurate and precise methods for assessing human exposure and effects. One of the most accurate and precise means of assessing exposure is to measure the level of the toxicant or its primary metabolite in a biologic specimen; this has been defined as measuring the internal dose. This measurement must be quantitative to best study the dose-response relationship. Pertinent questions asked during an exposure assessment include "How do the levels of a given toxicant in a particular population compare with the levels of that toxicant in other populations?" and "What is the prevalence of exposure to that toxicant in other populations?" To answer these questions for two chemical classes of environmental toxicants, we developed state-of-the-art analytic methods and then applied them to measure the levels of 44 environmental toxicants in biologic specimens from 1000 United States residents who participated in the Third National Health and Nutrition Examination Survey (NHANES III). These 1000 people are a cross-sectional subset of the NHANES III population and were selected from urban and rural communities in four regions of the United States; all were between 20 and 59 years of age. This subset is not a probability-based sample.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Traditional lipoprotein profile: clinical utility, performance requirement, and standardization.

The lipid and lipoprotein parameters which are predominantly measured and effectively comprise the traditional lipoprotein profile include total cholesterol, high density lipoprotein (HDL) cholesterol, low density lipoprotein (LDL) cholesterol, and triglyceride. Total cholesterol is accepted as the initial entry point in a case finding approach such as that recommended by the National Cholesterol Education Program (NCEP). HDL cholesterol, known to be a strong inverse predicator of risk, is an additional measurement to total cholesterol to improve risk assessments. The evidence for triglyceride association remains mixed: although strong associations are found in some studies, the evidence as an independent risk factor is still incomplete. Triglyceride is therefore measured primarily for LDL estimation. Final classification and potential intervention is ultimately based on the measurement of LDL cholesterol. Reliability in the measurement of total cholesterol, HDL, LDL, and triglyceride is especially important if the uniform decision points established by the NCEP are to be properly implemented. Attention must be placed on controlling preanalytical sources of variation, which can account for as much as 60% of the total measurement variability. The major analytical source of error comes from matrix effects, which results in problems of proper analytical calibration. Instrument system calibration should be verified by a comparison with an accuracy base using fresh patient specimens. CDC has established a network of reference method laboratories to provide access to these lipid and lipoprotein accuracy bases.

Coronary Disease↗

Technical and scientific developments in exposure marker methodology.

Recent advances in techniques to measure markers of exposure to environmental toxicants in humans are changing the ways in which environmental scientists, epidemiologists, and policymakers characterize and interpret such exposure. In this article we review some major technical and scientific developments in exposure marker methodology for estimating internal dose, with special reference to studies conducted at the US Centers for Disease Control and Prevention. We consider important characteristics of laboratory methods, advances in laboratory technology, analytical standards, and quality assurance of laboratory measurements; comparisons with indirect methods for estimating exposures, such as exposure indices and questionnaires; human pharmacokinetic data; sampling problems; surveillance of human exposures to toxicants; and interpretation of measurements. With a view to increasing the reliability of exposure assessment, we make recommendations for obtaining more data on human exposure to toxicants.

Biomarkers↗

Estimating and minimizing effects of biologic sources of variation by relative range when measuring the mean of serum lipids and lipoproteins.

Biologic intraindividual variation (CVb) is a major source of inaccuracy in current lipid and lipoprotein measurements. Metaanalysis has been used to estimate the average CVb of serum total cholesterol (TC), high-density lipoprotein cholesterol (HDLC), low-density lipoprotein cholesterol (LDLC), and triglyceride (TG). These CVb values are larger than the National Cholesterol Education Program-accepted and -proposed analytic (CVa) goals. Measuring serial specimens reduces the error in determination of the mean concentration used in classification of the patient by cutoff points. We show (a) a convenient technique, based on the relative range, to qualitatively estimate and interpret biologic variation of TC, HDLC, LDLC, and TG, and (b) the number of serial specimens required to meet a total variation goal for measurements of mean lipid and lipoprotein values. A total variation goal has been selected that can be met by two serial specimens for a majority of individuals.

Cholesterol↗

Tryptophan contaminants associated with eosinophilia-myalgia syndrome. The Eosinophilia-Myalgia Studies of Oregon, New York and New Mexico.

Eosinophilia-myalgia syndrome (EMS) has been linked to ingestion of tryptophan contaminated with 1,1'-ethylidene-bis[L-tryptophan] (EBT), but other contaminants have received little study. The authors identified 101 lots of L-tryptophan that had been consumed either by persons with EMS or by asymptomatic tryptophan users and quantified the amounts of EBT and five other contaminants in each lot. After stratification of case and noncase lots by time of manufacture to adjust for the strong sequential pattern over time among case and noncase lots, higher EBT levels were still associated with a lot's case status, but the association lacked statistical significance (p = 0.120, odds ratio = 1.56, 95% confidence interval 0.758-3.23). While these findings do not rule out the possibility that EBT is the etiologic agent in EMS, they raise the possibility that other chemical contaminants in manufactured tryptophan modify the effects of EBT or that the causal agent of EMS is an entirely distinct compound.

Drug Contamination↗

Contaminants in L-tryptophan associated with eosinophilia myalgia syndrome.

In late 1989, an epidemic of eosinophilia-myalgia syndrome (EMS) that resulted in several thousand cases of the syndrome and 36 deaths was recognized in the United States. Physicians in New Mexico linked the epidemic to the ingestion of L-tryptophan (LT). Results of studies indicated that one or more trace contaminants in LT were likely causes of the EMS epidemic. Investigators traced the LT that was taken by most patients with EMS to a single manufacturer, Showa Denko K.K. of Japan. We now report results of high performance liquid chromatographic analysis of LT samples from this manufacturer. Three sets of blind-coded samples were analyzed: the priority case lot set, which included 54 case-associated LT lots and 50 noncase-associated LT lots that were taken by case and control subjects who used only one brand of LT; the single lot case set, which included 73 case-associated LT lots and 25 noncase associated LT lots taken by case and control subjects who used only a single lot of LT; and the South Carolina tablet set, which included LT tablets taken by case subjects (n = 26) and by control subjects (n = 52). We statistically compared the concentration of each contaminant in case-associated, noncase-associated, and control samples of each sample set. The analyses showed that there were more than 60 minor contaminants in the LT from Showa Denko K.K., and that six of these contaminants were associated with EMS. The structures of three contaminants are known, but the identities of the other three contaminants are currently unknown.(ABSTRACT TRUNCATED AT 250 WORDS)

Bacillus↗

Biological variability in concentrations of serum lipids: sources of variation among results from published studies and composite predicted values.

To obtain the best estimates of the average intraindividual biological variability (CVb) in the concentrations of total cholesterol (TC), low-density lipoprotein cholesterol (LDLC), high-density lipoprotein cholesterol (HDLC), and triglyceride serum lipids in a person's blood, we evaluated results from 30 studies published from 1970 to 1992. The usually more applicable random-effects model estimated an average CVb of 6.1% for TC, 7.4% for HDLC, 9.5% for LDLC, and 22.6% for triglyceride. Composite estimates of the average CVb from all evaluated published studies by different models of estimation ranged from 6.0% to 6.4% for TC, from 6.2% to 7.5% for HDLC, from 7.0% to 9.6% for LDLC, and from 22.4% to 22.9% for triglyceride. Two important factors influenced the reported biological variation of the study subjects: (a) the magnitude of the variability of the analytical method used and (b) the design characteristics of the study--primarily the number of subjects, the sampling interval, and the number of measurements per subject. For TC, we found a statistically significant positive correlation between the reported mean CVb and both the number of study subjects and the analytical variation. For TC and LDLC we estimate CVb as a function of the study design features. The number of patient specimens required to obtain reliable estimates for serum lipid concentrations are determined from the CVb and the current analytical variation.

Cholesterol↗

Factors influencing the accuracy of the national reference system total cholesterol reference method.

Previous comparisons between the Reference and Definitive Methods for measuring serum cholesterol have demonstrated a small but persistent positive bias in the Reference Method, averaging about +1.6%. Here we describe the results of further investigations designed to better characterize the nature of this bias. Analysis of a well-characterized model serum sample (SRM 909) suggests that more than half of the difference in cholesterol values determined by the two methods is the result of small contributions from cholesterol precursor sterols and phytosterols, which are also measured for the Reference Method. An additional significant contribution may be from cholesterol oxidation products, particularly 7-hydroxycholesterol isomers, which are active in the Liebermann-Burchard reaction. The 7-hydroxycholesterol in SRM 909, most of which appeared to be already present in the serum rather than formed during saponification, may account for as much as 20% of the observed difference between the methods. Contributions from other possible sources, including impurities in the cholesterol standard and incomplete saponification of cholesteryl esters, are very small. Because the observed bias is both quite small and consistent among samples, the cholesterol Reference Method continues to meet all of the requirements generally expected for a dependable and effective Reference Method.

Carbon Isotopes↗

Standardization of lipid, lipoprotein, and apolipoprotein measurements.

Accurate laboratory measurement of serum cholesterol has become a national public health priority. National proficiency testing surveys indicate that laboratory inaccuracy in cholesterol testing is more of a problem than precision. Like precision, accuracy is a function of multiple pre-analytical and analytical sources of variation. Controlling pre-analytical sources of variation helps minimize such sources of variation as intraperson biological, behavioral, and clinical differences, and variations caused by sample collection, handling, and shipping. Standardization of analytical sources of variation helps to achieve and maintain desirable analytical performance, accurate reporting, and correct interpretation of a reported cholesterol result. The intraperson total variation in lipoproteins and their constituents is of primary interest when one is interpreting a single result or a series of results from a single person. The mean of multiple specimens from the same person is required if one is to obtain an accurate value for intraperson total cholesterol and minimize pre-analytical sources of variation. Standardizing analytical sources of variation in some instrument systems requires standardizing results by using "fresh" patients' specimens.

Apolipoproteins↗

2,3,7,8-Tetrachlorodibenzo-p-dioxin levels in adipose tissue of exposed and control persons in Missouri. An interim report.

The compound 2,3,7,8-tetrachlorodibenzo-p-dioxin, commonly known as dioxin, was measured in the adipose tissue of 39 persons with a history of residential, recreational, or occupational exposure in Missouri and in 57 persons in a control group. All participants had detectable levels of 2,3,7,8-tetrachlorodibenzo-p-dioxin in their adipose tissue, but the exposed group had significantly higher levels. Levels of six of the exposed persons were more than five times greater than the level of the highest control. Measuring 2,3,7,8-tetrachlorodibenzo-p-dioxin in adipose tissue provides a much improved index of exposure, an important advance for research studies evaluating the possible health effects of this compound.

Adipose Tissue↗

Determination of steroid hormones in a human-serum reference material by isotope dilution--mass spectrometry: a candidate definitive method for cortisol.

We report a method, based on isotope dilution--mass spectrometry, for determining cortisol in a pooled specimen of human serum. Isotopically labeled cortisol is added to 5.0 mL of serum so that the molar concentrations of labeled cortisol and unlabeled cortisol are approximately equal. The specimen and two calibration standards are extracted with dichloromethane, and the extracted cortisol is converted to the methoxime-trimethylsilyl ether derivative. Samples and standards are analyzed by gas chromatography--mass spectrometry by monitoring the peak areas for m/z 605 and 608. The cortisol concentration is calculated by linear interpolation between the two bracketing standards. Variances of data collected during six weeks showed that the overall coefficient of variation (CV) was 0.69% (n = 32); the within-vial CV, 0.63%; the among-vial CV, 0.22%; and the among-day CV, 0.15% (means = 3.973 nmol/vial). Method specificity was demonstrated by liquid chromatographic as well as C8 mini-column cleanup of samples before derivation, by alternative ion monitoring at m/z 636 and 639, and by negative-ion chemical ionization at m/z 459 and 462. Derivatives of all observed degradation products of cortisol under basic, neutral, and acidic conditions did not interfere.

Chromatography, High Pressure Liquid↗

Multivariate examination of response surfaces around the reaction conditions for the Scandinavian Society's recommended method for creatine kinase determinations.

We examined the reaction surfaces around five variables (imidazole, ADP, creatine phosphate, magnesium, and pH) in the Scandinavian method for determining creatine kinase, using factorial experimentation (five level, five factor) at reaction temperatures of 30 and 37 degrees C. Theoretical response surfaces were computed by fitting a quadratic polynomial equation to the experimental data by least-squares regression. Essentially no differences were apparent in the theoretical curves among the five specimens we analyzed, or between reaction temperatures. Our response-surface data showed the following: for pH and imidazole, activity optima in the region of the Scandinavian conditions; for creatine phosphate, a broad plateau over the concentration range investigated (10 to 50 mmol/L); and for magnesium and ADP, gently increasing contours with maximal creatine kinase activity at concentrations greater than those investigated in our study (magnesium 15 mmol/L, ADP 3.5 mmol/L).

Adenosine Diphosphate↗