Search PubMed⌕ Search

Biomedical subjects

E J Hoffman

Publications and source records attributed to E J Hoffman.

At least 37 records · Page 2Linked to original sources

Whole-body positron emission tomography: Part I. Methods and performance characteristics.

Methods for whole-body PET imaging have been developed to provide a clinical tool for the detection and evaluation of primary and metastatic cancers. The axial FOV of the PET system is extended by imaging at multiple bed positions to cover the whole body. In typical rectilinear PET scans, only a small fraction of the data is collected to form two-dimensional projection images. In this work, 100% of the projection data was collected to form the two-dimensional projection images. These projection images were generated for continuous angles over 180 degrees by resorting sinogram data. In addition, tomographic images were formed by using filtered backprojection reconstruction without attenuation correction. Coronal and sagittal cuts were then extracted from the three-dimensional data set. The tomographic images were reconstructed to a resolution of 10.8 mm in all dimensions because of statistical limitations of the data. Both methods of image formation resulted in images of high quality with the tomographic reconstruction providing the highest contrast and resolution. An acquisition time of 1-2 min/bed position after a 10-mCi injection of [18F]fluoride ion or [18F]FDG was found to give a sufficient number of counts for producing images of good resolution and contrast, from a total scanning time of 32-64 min.

Deoxyglucose↗

Assessment of accuracy of PET utilizing a 3-D phantom to simulate the activity distribution of [18F]fluorodeoxyglucose uptake in the human brain.

A three-dimensional brain phantom has been developed to simulate the activity distributions found in human brain studies currently employed in positron emission tomography (PET). The phantom has a single contiguous chamber and utilizes thin layers of lucite to provide apparent relative concentrations of 5, 1, and 0 for gray matter, white matter, and CSF structures, respectively. The phantom and an ideal image set were created from the same set of data. Thus, the user has a basis for comparing measured images with an ideal set that allows a quantitative evaluation of errors in PET studies with an activity distribution similar to that found in patients. The phantom was employed in a study of the effect of deadtime and scatter on accuracy in quantitation on a current PET system. Deadtime correction factors were found to be significant (1.1-2.5) at count rates found in clinical studies. Deadtime correction techniques were found to be accurate to within 5%. Scatter in emission and attenuation correction data consistently caused 5-15% errors in quantitation, whereas correction for scatter in both types of data reduced errors in accuracy to less than 5%.

Brain↗

Performance standards in positron emission tomography.

A standard set of performance measurements is proposed for use with positron emission tomographs. This set of measurements has been developed jointly by the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. The measurements include tests of spatial resolution, scatter fraction, sensitivity, count rate losses and randoms, uniformity, scatter correction, attenuation correction, and count rate linearity correction.

Humans↗

Three-dimensional SPECT simulations of a complex three-dimensional mathematical brain model and measurements of the three-dimensional physical brain phantom.

We have developed a three-dimensional computer simulation of SPECT imaging. We have applied the simulation procedure to the realistic mathematical Hoffman three-dimensional brain model to generate the projection data (in the absence of attenuation, scatter, or noise) of both a parallel-hole and a multidetector SPECT system with point-focusing collimators. The simulated projection data were then reconstructed using standard software. The projection data resulting from the distribution of grey matter alone, or grey and white matter, were simulated. The results of these simulations indicate the existence of significant qualitative and quantitative artifacts in reconstructed human brain images. For example, the reconstructed values for grey matter along a cortical circumferential profile in a transverse slice through the basal ganglia varied by a factor of 2.40 (parallel-hole) and 2.99 (point-focusing), although the original grey matter values were identical in all cortical regions in the model. We have compared the simulated reconstructed images with those obtained by imaging the physical three-dimensional Hoffman brain phantom, which was constructed based upon the same set of data from which the mathematical three-dimensional Hoffman brain model was derived. Although the simulation did not include all of the degrading factors present in the physical imaging, the two images were in good agreement, indicating the applicability of the simulation to a realistic situation and the importance of the detector resolution effect.

Artifacts↗

The C15O2 build-up technique to measure regional cerebral blood flow and volume of distribution of water.

A new method to measure regional CBF (rCBF) and volume of distribution of water is presented. It centres on recording the tissue build-up and retention of 15O-labelled water during the continuous inhalation of 15O-labelled carbon dioxide. Simultaneously, the arterial concentration is continuously monitored, and corrections for delay and dispersion in the recorded response are made by curve fitting. The values for the volume of distribution of water obtained in four normal subjects were close to reported in vitro values. Using the same fixed distribution volumes for both build-up and steady-state studies resulted in comparable rCBF values for both techniques.

Adult↗

13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography.

Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided into eight sectors, and a small region of interest was assigned to the left ventricular blood pool to obtain the arterial input function. The net extraction of 13N ammonia was obtained for each sector by dividing the tissue 13N concentration at 10 minutes by the integral of the input function from the time of injection to 10 minutes. With this approach for calculating net extractions, rest and exercise net extractions were not significantly different from each other. To obviate possible overestimation of the true 13N ammonia input function by contamination by 13N-labeled compounds other than 13N ammonia or by spillover from myocardium into blood pool, the net extractions were calculated using only the first 90 seconds of the blood and tissue time-activity curves. This approach for calculating net extractions yielded significant differences between rest and exercise, with an average ratio of exercise to rest of 1.38 +/- 0.34. Nonetheless, the increase was less than predicted from the average 2.7-2.8-fold increase in double product at peak exercise or the 1.7-fold increase in double product at 1 minute after exercise. However, when the first 90 seconds of dynamic data were fit with a two compartment tracer kinetic model, average perfusion rates of 0.75 +/- 0.43 ml/min/g at rest and 1.50 +/- 0.74 ml/min/g with exercise were obtained. This average increase in perfusion of 2.2-fold corresponded to similar average increases in double product. Thus, the noninvasive technique of PET imaging with 13N ammonia shows promise for future applications in determining absolute flows in patients with coronary artery disease.

Adult↗

Validation of PET-acquired input functions for cardiac studies.

To validate the determination of the arterial input function by noninvasive dynamic PET imaging, measurements of blood-pool activity in canine LV by PET were compared to beta probe measurements of arterial blood withdrawn directly from the LV. PET scans were done during intravenous bolus injections of [13N]ammonia or 82Rb, while the activity of blood withdrawn continuously from a catheter inserted in the LV was measured with a beta probe. PET determinations of LV blood-pool activity were compared with dispersion-corrected beta probe time-activity curves. In 15 experiments involving four dogs under a wide range of physiologic conditions, LV time-activity curves obtained with PET matched well in shape with those obtained with the beta probe. Linear regression yielded slopes within 10% of unity (95% confidence interval) and high correlation (r greater than 0.968, p less than 0.001). We conclude that noninvasive measurement of the arterial input function by dynamic PET imaging is valid.

Ammonia↗

Measurement of glucose and 2-deoxy-2-[18F]fluoro-D-glucose transport and phosphorylation rates in myocardium using dual-tracer kinetic experiments.

To examine the use of 2-deoxy-2-[18F]fluoro-D-glucose (2-FDG) as a glucose analog for measuring glucose utilization rate in myocardium, dual-tracer kinetic experiments with 2-FDG and 2-[3H]glucose were performed in the perfused, isolated rabbit interventricular septum to measure simultaneously the transport and phosphorylation rates of glucose and 2-FDG. Results of the present study indicated that, in the septum, the transport rate constants of 2-FDG and glucose were similar in magnitude, the phosphorylation rate constant for 2-FDG was about 60% of that of glucose, hypoxia caused an increase in phosphorylation rates of glucose and 2-FDG without affecting transport.

Animals↗

Quantitative measurement of myocardial blood flow with oxygen-15 water and positron computed tomography: an assessment of potential and problems.

An in vivo measurement technique using 15O water and positron CT for quantitation of myocardial blood flow (MBF) was investigated. A closed-chest dog model and NeuroECAT scanner were used in the study. The in vivo technique involves i.v. infusion of 15O water for a duration of 2-3 min. Oxygen-15 water radioactivity in myocardium was imaged with a NeuroECAT scanner for 10 min, starting at the time of tracer infusion. A separate scan following inhalation of 15O CO was obtained to label the blood pool and to help remove the contribution of radioactivity in the blood pool during the 15O water scans. The integrated projection technique was used for calculating MBF. The quantitative microsphere technique for measurement of MBF was performed along with the 15O water study to provide reference values, with which the MBF values by the in vivo technique was compared. Results of 12 experimental runs (in seven animals) show the in vivo technique with 15O water and positron CT can give quantitative flow images of myocardium. The in vivo positron CT measurement was found to correlate well (r = 0.93) with the in vitro values (by microspheres) over the flow range of 40 to 150 ml/min/100 g.

Animals↗

Prospects for both precision and accuracy in positron emission tomography.

Reproducibility or precision was measured for a current positron emission tomographic (PET) system and was simulated by both computer and experimental methods for potential future systems. The present and potential future precision of PET systems is on the order of 1 to 2% for equilibrium studies (such as fluorodeoxyglucose metabolism measurements) with a few million counts per image, and better than 10% for dynamic studies with a few hundred thousand counts per image. To take advantage of this high precision, the instrumental accuracy of PET systems should match or better the precision of the measurements. The major sources of inaccuracy in PET, outside of deficiencies in electronic or computer hardware and software, are poor resolution, nonuniform resolution, and scatter. The use of narrow bismuth germanate detectors, adequately large detector ring diameters, and properly designed interplane septa will provide substantial improvements in all of these deficiencies.

Brain↗

Cardiac emission computed tomography: underestimation of regional tracer concentrations due to wall motion abnormalities.

Possible effects of regional wall motion abnormalities on apparent regional myocardial tracer concentrations on emission tomographic images were evaluated in six open chest dogs. Each dog was studied twice: In Run 1, 13N ammonia and microspheres were injected during a 6 min coronary occlusion, and serial images acquired by positron emission tomography during occlusion and reperfusion. In Run 2, 1 h later, 13N ammonia and microspheres were reinjected at control, and serial images recorded at control, during a repeat 6 min coronary occlusion, and after reperfusion. Segmental function was monitored with ultrasonic crystals, and 13N tissue concentrations determined in vivo from the tomographic images and postmortem by well counting. In Run 1, fractional shortening in ischemic segments fell by 89 +/- 16% SD from control. The ischemic versus control segment ratio for 13N activity concentrations averaged 0.29 +/- 0.08 and for microspheres 0.20 +/- 0.15. In Run 2 the ischemic versus control segment ratio was at control 0.77 +/- 0.12 for 13N tissue activity and 0.85 +/- 0.07 for microspheres. Fractional shortening fell during occlusion by 131 +/- 29% from control, returned to control early, and fell again by 11 +/- 16% late during reperfusion. These changes were paralleled by changes in apparent regional 13N tissue concentrations of the prelabeled myocardium. Compared with control, they were 37 +/- 9% lower during occlusion and rose to 94 +/- 20% early and to 89 +/- 16% at control late during reperfusion. In vitro determined tissue concentration ratios of ischemic to control myocardium were similar for 13N and microsphere activity (0.83 and 0.85), which ruled out loss of 13N ammonia from tissue during occlusion or reperfusion. Our results indicate that regional wall motion abnormalities cause artifactual segmental defects in tracer concentrations on emission tomographic images of the heart, which must be considered for qualitative and quantitative analysis of regional tracer tissue concentrations.

Ammonia↗

Quantitative measurement of local cerebral blood flow in humans by positron computed tomography and 15O-water.

A noninvasive method that employs 15O-water and positron-computed tomography (PCT) was used to measure quantitative local cerebral blood flow (lCBF) in man. 15O-Water (about 30-50 mCi) was introduced through a single-breath inhalation of 15O-carbon dioxide or through an intravenous bolus injection of 15O-water. A sequence of five 2-min PCT scans was initiated at the time of tracer administration. A series of 15-20 blood samples (1 ml each) was withdrawn from the radial artery of the subject over a period of 10 min. Oxygen-15 radioactivities in the blood samples were immediately counted in a well counter to give an input function, which together with the projection data collected by PCT were processed to provide images of 1CBF and local water distribution volume. The method was found to be convenient to use and gave good-quality images of 1CBF. Quantitative values of 1CBF in images were 59 +/- 11 and 20 +/- 4 ml/min/100 g for gray and white matter, respectively, with a gray-to-white matter ratio of 2.93 and a global flow value of 42 +/- 8 ml/min/100 g. Distribution volume of water was 0.85 +/- 0.03, 0.76 +/- 0.03, and 0.81 +/- 0.02 ml/g respectively, for gray matter, white matter, and whole brain.

Adult↗

Identification and characterization of axopodial tubulins from Echinosphaerium nucleofilum.

Isolated microtubule protein from axopodia of the heliozoan Echinosphaerium nucleofilum, consisting of two major bands on SDS-polyacrylamide gel electrophoresis (SDS-PAGE), has been compared to axonemal and cytoplasmic tubulins from both animal and non-animal sources. The upper E. nucleofilum protein band migrated faster than the alpha-tubulins of bovine brain and sea anemone sperm tails but with approximately the same electrophoretic mobility as the axonemal alpha-tubulins of Tetrahymena pyriformis and the alga Chlorogonium elongatum and cytoplasmic alpha-tubulin from the slime mold Physarum polycephalum. The lower E. nucleofilum protein band, however, had a higher electrophoretic mobility than all the beta-tubulins which we have so far examined. It was, nevertheless, a true beta-tubulin as shown by its migration on two-dimensional gel electrophoresis and the general resemblance of its one- and two-dimensional peptide maps to those of other beta-tubulins. The Staphylococcus aureus protease cleavage pattern of the upper axopodial protein band was similar to those of other non-animal alpha-tubulins but quite different from those of the animal alpha-tubulins. In contrast, the two-dimensional tryptic peptide map of axopodial alpha-tubulin was distinct from all of them. For example, a characteristic constellation of peptides common to the peptide maps of the other alpha-tubulins was absent from that of E. nucleofilum. In contrast to Physarum and metazoan tubulins but similar to Tetrahymena tubulin, the axopodial alpha-tubulin had a more basic isoelectric point than the beta-subunit as shown by two dimensional gel electrophoresis. Some of the unusual characteristics of E. nucleofilum axopodial tubulin may not only reflect phylogenetic variation, but also the different functional requirements of axopodial microtubules.

Animals↗

Performance evaluation of a positron tomograph designed for brain imaging.

The NeuroECAT, a multiplane positron tomograph for imaging the brain, was characterized in terms of both quantitative performance and image quality. The tomograph has four modes of operation, defined by the placement of interplane septa and shadow shields. Each mode was fully characterized by measurement of image resolution, axial resolution, resolution uniformity, scatter, accidentals, and deadtime. Each measurement was performed with scattering media simulating the human head, and resolutions were obtained from images processed with reconstruction techniques actually used in patient imaging. The results for the most frequent mode of operation are: image resolution 9.8 +/- 0.2 mm (FWHM), axial resolution 12.4 +/- 0.4 mm, and scatter 8.1% +/- 0.6. At a count rate of 10,000 cps per image plane, accidentals are 9% and the deadtime 3%. Accidentals are measured and subtracted in hardware, and corrections for deadtime loss are calculated from the on-line measurement of triple-coincidence events. Scatter is estimated from the scan data and subtracted in software. Image quality is demonstrated by phantom studies and by the patient images obtained with [F-18] fluorodeoxyglucose and carbon-11 monoxide. The FDG images show clear delineation of the convolutions of the cortical ribbon, internal gray nuclei, internal and external capsules, and other substructures of the brain. The carbon monoxide images, in addition to visualizing the large vessels, clearly show the blood volumes of the cortex, the Sylvian fissure, and the circle of Willis.

Brain↗

Noninvasive assessment of coronary stenoses by myocardial imaging during pharmacologic coronary vasodilation. VI. Detection of coronary artery disease in human beings with intravenous N-13 ammonia and positron computed tomography.

The possibility of detecting mild coronary stenoses with positron computed tomography and nitrogen (N-13) ammonia administered during pharmacologic coronary vasodilation was previously demonstrated in chronically instrumented dogs. The feasibility of using this technique in human beings and its sensitivity in determining the degree and extent of coronary artery disease were examined in 13 young normal healthy volunteers and 32 patients with angiographically documented coronary artery disease. N-13 ammonia was administered intravenously and its distribution in the left ventricular myocardium recorded at rest and during dipyridamole-induced coronary hyperemia. In the 13 volunteers, N-13 activity was homogeneous at rest and during hyperemia, whereas 31 of the 32 patients had regional defects on the hyperemic images not present during rest. All six patients with double, all 10 with triple and 15 of 16 patients with single vessel disease (97 percent) were correctly identified with the technique. Two vessel involvement was correctly identified in five of the six patients with double vessel disease and three vessel disease in six of 10 patients. Of all 58 coronary stenoses, 52 (90 percent) were correctly identified. In a subgroup of 11 patients, the technique was compared with exercise thallium-201 planar images, which were abnormal in 10 (91 percent) whereas N-13 images were abnormal in all 11. Of the 19 stenosed coronary arteries in this subgroup, 11 (58 percent) were correctly identified with thallium-201 and 17 (89 percent) with tomography (p less than 0.01). It is concluded that cross-sectional imaging of the myocardial distribution of N-13 ammonia administered during pharmacologic coronary vasodilation is a highly sensitive and accurate means for noninvasive detection of coronary stenoses in human beings and for estimating the extent of coronary artery disease.

Adolescent↗