Search PubMed⌕ Search

Biomedical subjects

E Ishikawa

Publications and source records attributed to E Ishikawa.

At least 55 records · Page 3Linked to original sources

Water permeability of plasma membranes of cultured rice, grape, and CH27 cells measured dielectrically.

The capacitance of suspensions of cultured rice cells (Oryza sativa L. ssp. japonica), grape cells (Vitis sp.), and CH27 cells originated from murine B-cell lymphoma was measured in the frequency range of 0.2 to 10 MHz. The relationship between the increase in capacitance caused by the presence of cells at 0.4 MHz, delta C, and the cell density was linear. Measurement of capacitance was useful in measurement of transitional changes in cell volume under external osmotic stress when sucrose was added. From the course of volume changes with such stress, the water permeabilities of the plasma membrane, Lp, were measured to be 0.015, 0.020, and 0.090 pm/(s.Pa) at 25 degrees C, for rice cells, grape cells, and CH27 cells, respectively. The smaller Lp for plant cells seemed to explain why preservation of plant cells by freezing is more difficult than for animal cells. From the temperature dependence of Lp, the apparent activation energies were calculated to be 12.0 +/- 2.9 and 13.0 +/- 5.2 kcal/mol for rice cells and CH27 cells, respectively.

Animals↗

Total anomalous pulmonary vein drainage in an adult diagnosed by helical computed tomography.

A 41-year-old man visited our hospital with the complaint of palpitation by atrial flutter. He was finally diagnosed as total anomalous pulmonary vein drainage by helical computed tomography (CT). This case is very unusual due to the lack of symptoms until the age of 41. The absence of pulmonary artery stenosis, and the presence of atrial septal defect providing sufficient right to left shunt flow to maintain the output of left ventricle are some of the reasons to explain the lack of symptoms and very slight impact on daily life. Helical CT, in particular 3-dimensional imaging, is very useful in diagnosing complicated cardiovascular deformation as in this case.

Adult↗

More reliable diagnosis of infection with human immunodeficiency virus type 1 (HIV-1) by detection of antibody IgGs to pol and gag proteins of HIV-1 and p24 antigen of HIV-1 in urine, saliva, and/or serum with highly sensitive and specific enzyme immunoassay (immune complex transfer enzyme immunoassay): a review.

Ultrasensitive enzyme immunoassays (immune complex transfer enzyme immunoassays) were developed for antibody IgGs to HIV-1 using recombinant reverse transcriptase (rRT), p17 (rp17), and p24 (rp24) as antigens. Antibody IgGs were reacted with 2,4-dinitrophenyl-recombinant antigens and recombinant antigen-beta-D-galactosidase conjugates, and the immune complexes formed, comprising the three components, were trapped onto polystyrene beads coated with (anti-2,4-dinitrophenyl group) IgG. After washing, the immune complexes were eluted from the polystyrene beads with excess of epsilon N-2,4-dinitrophenyl-L-lysine and were transferred to clean polystyrene beads coated with (antihuman IgG gamma-chain) IgG. beta-D-Galactosidase activity bound to the last polystyrene beads was assayed by fluorometry. By transfer of the immune complexes from one solid phase to another, the nonspecific binding of the beta-D-galactosidase conjugates was minimized and the sensitivity was markedly improved. The immune complex transfer enzyme immunoassays using rRT, rp17, and rp24 as antigens were 300-1,000-fold, 1,000-3,000-fold, and 30-100-fold, respectively, more sensitive than Western blotting for the corresponding antigens and 10-300-fold more sensitive than a conventional ELISA and a gelatin particle agglutination test. For urine (100 microliters), whole saliva (1 microliter), and serum (1 microliter) samples, the sensitivity and specificity of the immune complex transfer enzyme immunoassay using rRT as antigen were both 100%. However, for urine samples in which the specific activities of antibody IgG to RT, p17, and p24 were much lower than those in serum samples probably due to degradation by the kidney, a longer assay of bound beta-D-galactosidase activity or/and a concentration process for urine was required. The use of more than 1 microliter of whole saliva was recommended for reliable diagnosis of the infections, whereas 1 microliter of serum was sufficient for the purpose. The positivity with rRT as antigen could be confirmed by demonstration of antibody IgGs to p17 and p24 in most of the urine, whole saliva, and serum samples. In HIV-1 seroconversion serum panels, antibody IgG to p17 was detected as early as or even earlier than antibodies to HIV-1 by a conventional ELISA or/and a gelation particle agglutination test, whereas antibody IgGs to RT and p24 were detected as early as or later than antibody IgG to p17. Thus the uses of rRT and rp17 as antigens were advantageous over that of the other antigens for randomly collected serum samples probably long after the infection and serum samples at early stages of the infection, respectively. On the basis of these results and other reports, the immune complex transfer enzyme immunoassay was developed for simultaneous detection of p24 antigen and antibody IgGs to RT and p17 in a single assay tube, and the window period (8 weeks, although widely variable), during which diagnosis of HIV-1 infection is not possible due to the absence of detectable antibodies to HIV-1, was shortened by 2 weeks. As a result, the simultaneous detection made possible not only as early diagnosis as that by detection of p24 antigen, but also as reliable diagnosis as that by detection of antibodies to HIV-1. Finally, the immune complex transfer enzyme immunoassay has been recently improved so as to be performed within shorter periods of time (2-3 hr) with higher sensitivity, and testing many samples has become easy.

Acquired Immunodeficiency Syndrome↗

Whole saliva dried on filter paper or diagnosis of HIV-1 infection by detection of antibody IgG to HIV-1 with ultrasensitive enzyme immunoassay using recombinant reverse transcriptase as antigen.

Whole saliva samples collected from HIV-1 seropositive subjects by simple spitting without using any devices were dried on filter paper strips, from which filter paper discs of 3-mm diameter were punched out. The eluates of the discs were subjected to the immune complex transfer enzyme immunoassay for antibody IgG to HIV-1 using recombinant reverse transcriptase of HIV-1 as antigen and a two-site enzyme immunoassay for whole IgG. The signals for antibody IgG to HIV-1 and the amounts of whole IgG obtained with one disc per assay tube were 126-290% of those obtained with 1 microliter of whole saliva samples, provided that filter paper strips were treated with nonspecific rabbit serum prior to drying whole saliva samples and that filter paper discs were tested within a few days after drying whole saliva samples. From these results, diagnosis of HIV-1 infection was indicated to be possible with whole saliva samples dried on filter papers, since the diagnosis was previously shown to be possible with 1 microliter of whole saliva samples. The test for HIV-1 infection with whole saliva samples dried on filter papers was suggested to be useful for various purposes.

Acquired Immunodeficiency Syndrome↗

Earlier diagnosis of HIV-1 infection by simultaneous detection of p24 antigen and antibody IgGs to p17 and reverse transcriptase in serum with enzyme immunoassay.

Serum samples of four HIV-1 seroconversion serum panels were subjected in a single assay tube simultaneously to ultrasensitive enzyme immunoassays (immune complex transfer enzyme immunoassays) for p24 antigen of HIV-1 and for antibody IgGs to p17 and reverse transcriptase (RT) of HIV-1. Signals became positive 7-15 days earlier than the detection of antibodies to HIV-1 by conventional methods and remained strongly positive even after levels of p24 antigen declined. Thus the simultaneous detection of p24 antigen and antibody IgGs to p17 and RT made possible both as early a diagnosis of HIV-1 infection as the appearance of p24 antigen in the circulation, shortening "the window period," and as reliable a diagnosis of the infection as that by the detection of antibodies to HIV-1 from the time of seroconversion until late stages of the infection, since the serum level of antibody IgG to RT was high not only in asymptomatic carriers but also in patients with AIDS-related complex and AIDS.

Adult↗

Simple and more sensitive immune complex transfer enzyme immunoassay for antibody IgG to reverse transcriptase of HIV-1 using microplates, modified polystyrene solid phase and fluororeader.

In a previously reported ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for antibody IgG to HIV-1, polystyrene beads in test tubes were handled with tweezers, and bound beta-D-galactosidase activity was measured with a fluorometer. The use of tweezers was causative of false-positivity by carryover, and testing many samples was difficult. Recently, these drawbacks have been minimized using microplates, a fluororeader, and modified polystyrene beads with sticks for easy handling. The modified polystyrene beads were transferred from wells to wells more quickly and easily without tweezers, eliminating false-positivity due to carryover. The fluorescence intensity for bound beta-D-galactosidase activity was quickly measured with a fluororeader. As a result, it became easy to test many samples with high reliability. However, modified polystyrene beads used were handmade, and the sensitivity was lower than the previous assay with test tubes. In the present study, the condition of the immune complex transfer enzyme immunoassay for antibody IgG to reverse transcriptase of HIV-1 was optimized using microplates, a fluororeader, and polystyrene solid phase with stick, which is commercially available. Testing many samples became easy with higher sensitivity.

Adult↗

Ultrasensitive and more specific enzyme immunoassay (immune complex transfer enzyme immunoassay) for p24 antigen of HIV-1 in serum using affinity-purified rabbit anti-p24 Fab' and monoclonal mouse anti-p24 Fab'.

Previously, an ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for p24 antigen of HIV-1 was developed. The immune complex comprising 2,4-dinitrophenyl-biotinyl-bovine serum albumin-rabbit anti-p24 Fab' conjugate, p24 antigen, and rabbit anti-p24 Fab' -beta-D-galactosidase conjugate was trapped onto polystyrene beads coated with affinity-purified (anti-2,4-dinitrophenyl group) IgG, was eluted with epsilon N-2, 4-dintrophenyl-L-lysine, and was transferred to polystyrene beads coated with streptavidin. beta-D-Galactosidase activity bound to the streptavidin-coated polystyrene beads was assayed by fluorometry. This assay was highly sensitive. However, bound beta-D-galactosidase activity had to be assayed for a long time (20 h), and the nonspecific signal was observed in 5% serum samples from subjects with low risk of HIV infection. In the present study, the assay time for bound beta-D-galactosidase activity was shortened to 2.5 h by using 2,4-dinitrophenyl-biotinyl-bovine serum albumin-affinity-purified rabbit anti-p24 Fab' conjugate and affinity-purified rabbit anti-p24 Fab' -beta-D-galactosidase conjugate. Furthermore, the nonspecific signal was found to increase with increasing periods of time for storage of serum samples at -20 degrees C, and this increase was prevented without prolongation of the assay time for bound beta-D-galactosidase activity and without loss of the sensitivity by substituting monoclonal mouse anti-p24 Fab'-beta-D-galactosidase conjugate for affinity-purified rabbit anti-p24 Fab'beta-D-galactosidase conjugate.

Acquired Immunodeficiency Syndrome↗

Retiform haemangioendothelioma.

A case of retiform haemangioendothelioma (RH), a recently described rare cutaneous low-grade angiosarcoma, is presented. A 75-year-old female had a 3.5 cm cutaneous nodule in her right lower thigh with 10 year preoperative duration. Microscopically, the dermis and subcutis contained a diffuse and infiltrative neoplasm which was characterized by long arborizing blood vessels arranged in a retiform pattern lined by cuboidal and flattened cells, occasional hobnail appearance of endothelial cells, and a prominent small lymphocytic infiltrate. Small solid areas were also found. Neither significant cellular atypia nor mitotic activity was observed. Immunohistochemically, the tumour cells reacted with endothelial markers (CD31, CD34, factor-VIII-related antigen) and bound Ulex europaeus agglutinin 1. There was no pericytic component within the tumour. The tumour was diploid by flow cytometry. The patient had a local recurrence 27 months after the excision. These findings support the view that RH is a low-grade angiosarcoma and indicate that RH must be distinguished from conventional angiosarcoma.

Aged↗

Shortening of the window period in diagnosis of HIV-1 infection by simultaneous detection of p24 antigen and antibody IgG to p17 and reverse transcriptase in serum with ultrasensitive enzyme immunoassay.

Following HIV infection, there is a window period of 6-8 weeks, during which HIV antibodies are not detectable and the infection cannot be diagnosed by methods for detecting HIV antibodies. However, HIV antigens are detectable in the latter part of the window period, although the level of HIV antigens declines as the level of HIV antibodies increases. We developed an ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for the simultaneous detection of both p24 antigen of HIV-1 and antibody IgGs to p17 and reverse transcriptase of HIV-1 in a single assay tube and tested 11 HIV-1 seroconversion serum panels and serum samples randomly collected from 79 HIV-1 seropositive subjects and 100 HIV-1 seronegative subjects. The simultaneous detection was shown not only to shorten the window period significantly as compared with conventional methods for HIV-1 antibody detection but also to make possible a reliable diagnosis of HIV-1 infection from the time of seroconversion until late stages of the infection.

Antibodies, Viral↗

Mixed tumour of the vagina.

A 33-year-old Japanese woman presented with a polypoid 2.5 x 2.5 x 1.9 cm mass located in the posterior wall of the lower vagina. Microscopically, the tumour was composed of benign epithelial and stromal-type elements. Predominant epithelial elements were mucinous glands with squamous metaplasia and islands of mature squamous epithelium. The stromal-type cells showed reticular or short fascicular patterns with a transition to the epithelial elements. There was no dual epithelial-myoepithelial combination in the glands as seen in so-called mixed tumours (pleomorphic adenomas) of the salivary gland. Immunohistochemically, the epithelial elements were strongly positive for cytokeratin, PKK1 and epithelial membrane antigen, while the stromal-type cells co-expressed PKK1 and vimentin. Staining for S-100 protein, muscle actin, alpha-smooth muscle actin, desmin, and CD34 was uniformly negative in the tumour cells. The DNA pattern was diploid. The patient is alive and well without recurrence for 50 months after excision. These results indicate that an epithelial cell proliferation, probably of the remnant vestibular gland, plays a major role in the development of mixed tumours of the vagina.

Adenoma, Pleomorphic↗

Postmenopausal intra-abdominal desmoplastic small cell tumor.

Intra-abdominal desmoplastic small cell tumor (DSCT) usually occurs in infants and young male adults. A case of DSCT occurring in a 60 year old female is described. No other apparent primary origin was detected. A mesocolon tumor, measuring 23 x 12 x 10 cm, was composed predominantly of round to spindle cells which showed epithelioid- and focally sarcomatous arrangements. Immunohistochemically, the tumor cells showed perinuclear dot-like staining of CAM5.2, many cells expressed HHF35, and some cells contained vimentin, epithelial membrane antigen, desmin, alpha-smooth muscle actin, neuron-specific enolase, or Leu 7. Electron microscopic examination showed that the tumor cells had mesenchymal-fibroblastic features. The tumor had an aneuploid DNA content with high S-phase fraction. The patient, who was treated with adjuvant chemotherapy, was alive, having had three recurrences in 36 months. In the second and third recurrent lesions, increased cellular atypia and fascicular arrangements of spindle cells were observed. DSCT should be included in differential diagnoses of post-menopausal pelvic tumors which show light-microscopically and immunohistochemically divergent phenotypes.

Abdominal Neoplasms↗

Somatostatin infusion suppresses GH secretory burst frequency and mass in normal men.

In attempting to elucidate the neuroendocrine mechanisms that regulate pulsatile growth hormone (GH) secretion, we measured serum GH concentrations by an ultrasensitive immunofluorometric method in blood collected every 10 min for 8 h in 11 young healthy male volunteers (age range 21-31 yr) before and during somatostatin (SS) administration (an iv bolus dose of 350 micrograms followed by a continuous infusion at the rate of 6 micrograms.kg-1.h-1, which increases the circulating SS levels to approximately 570 pg/ml). Pulsatile GH secretion was analyzed using the computer-assisted pulse detection program cluster method and deconvolution analysis. The area and frequency of GH peaks were significantly reduced during SS infusion compared with basal values, but detectable pulsatile episodes were still present. These data suggest that, in adult males, SS controls pulsatile GH secretion and can decrease the mass and frequency of GH secretory bursts.

Adult↗

[Evaluation of the clinical usefulness of super dynamic 99mTc-HM-PAO SPECT in ischemic cerebrovascular disease--detection of hypo- and hyperperfusion area].

The purpose of this study is to assess the clinical usefulness of super dynamic SPECT of 99mTc-HM-PAO. Six patients with unilateral occlusion of middle cerebral artery (MCA) or internal carotid artery (ICA) in the chronic phase, and 5 patients with subacute cerebral infarction were studied. We used a ring-type SPECT "HEADTOME." Two types of collimator were used: a high sensitivity (HS) collimator for super dynamic scan and a high resolution (HR) collimator for static scan. First, the intravenous constant infusion of 99mTc-HM-PAO (925-1480 MBq) for 1 minute was started. After 30 seconds from the beginning of the injection, we performed the 12 seconds/frame super dynamic SPECT for 2 minutes. Then, the static SPECT for 10 minutes was done. For semiquantitative analyses, differential percentage of regional activity between affected and non-affected hemispheres was calculated in the 6th frame image of super dynamic SPECT and static SPECT image. In all 6 patients with unilateral occlusion of MCA and ICA, super dynamic SPECT images showed the better contrast of low perfusion areas in comparison with the static SPECT images. In 5 patients with subacute cerebral infarction who showed focal hyperactivities on static SPECT, focal hyperactivities (hyperperfusion or hyperemia) were displayed in 3 cases, whereas, focal hypo- or isoactivities (hypo- or isoperfusion) were shown in 2 cases on super dynamic SPECT. However, all patients with subacute cerebral infarction showed hyperfixation on static SPECT as compared with super dynamic SPECT. Although the image quality on super dynamic SPECT is not as high as that on static SPECT, cerebral hemodynamics would be detected with less backdiffusion of 99mTc-HM-PAO from the brain to blood, and with less accumulation of hydrophilic components in subacute infarct region. In conclusion, super dynamic SPECT in early distribution of 99mTc-HM-PAO using dedicated SPECT device might be helpful to detect cerebral perfusion close to true cerebral blood flow distribution.

Aged↗

Diagnosis of HIV-1 infection with whole saliva by detection of antibody IgG to HIV-1 with ultrasensitive enzyme immunoassay using recombinant reverse transcriptase as antigen.

Whole-saliva samples were collected from 45 asymptomatic carriers, 18 patients with AIDS-related complex (ARC) or AIDS, and 76 medical students by simple spitting with no stimulation and tested by an ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for anti-HIV-1 IgG using recombinant reverse transcriptase as antigen and beta-D-galactosidase as label. With as little as 1 microliter of whole saliva, the lowest signals among the 45 asymptomatic carriers, 8 patients with ARC, and 10 patients with AIDS were 38-, 78-, and 3-fold, respectively, higher than the highest signal among the medical students. When the volume of whole saliva for test was increased up to 100 microliters, no significant effect was observed on signals for seropositive cases and signals for the medical students increased only very slightly. Therefore, whole-saliva samples containing extremely low levels of anti-HIV-1 IgG, even 2,000-fold lower than the lowest level among the 45 asymptomatic carriers tested, were considered to be discriminated from those of seronegative individuals. Thus, the sensitivity and specificity were expected to be both 100% with whole saliva even for a larger number of samples, although the number of samples tested was limited.

Adolescent↗

Augmented expression of atrial myosin light chain 1 in ventricular aneurysms of human: enzyme immunoassay for atrial myosin light chain 1.

We established an enzyme immunoassay (EIA) for atrial myosin light chain 1 (ALC1) using monoclonal antibodies KA1 and KB1, which were specific for ALC1 and for both ALC1 and ventricular myosin light chain 1, respectively. The serum ALC1 levels of healthy subjects were 0.28 +/- 0.14 ng/ml (mean +/- SD). The tissue ALC1 levels of normal adult human atria were much higher than those of ventricles (p < 0.01, 2,120 +/- 1,200 in right atria, 2,180 +/- 1,450 in left atria vs. 36.0 +/- 20.2 in right ventricles, 37.7 +/- 15.3 in left ventricles, ng/mg of proteins). The tissue ALC1 levels of ventricular aneurysms were significantly higher than those of normal ventricles (p < 0.01, 206.7 +/- 101.8). These results indicate that ALC1 is augmented in aneurysms and that the EIA provides a useful tool to investigate the roles of ALC1.

Adult↗

Further simplification of ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for anti-HTLV-I IgG using microplates and fluororeader.

In a previously reported ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for anti-HTLV-I IgG, polystyrene beads were handled with tweezers, and bound beta-D-galactosidase activity was measured with a fluorometer. The use of tweezers was causative of false-positivity by carryover, and testing many samples was difficult. Recently, these drawbacks have been minimized using microplates and a fluororeader. However, tweezers were still required in the initial and final steps. In the present study, the immune complex, comprising 2,4-dinitrophenyl-antigen, anti-HTLV-I IgG, and antigen-beta-D-galactosidase conjugate, was formed in and trapped onto microplate wells coated with (anti-2,4-dinitrophenyl group) IgG. Subsequently, the microplate wells were incubated with epsilon N-2,4-dinitrophenyl-L-lysine and polystyrene beads, modified by attaching to plates through cylindrical bars and coated with (antihuman IgG gamma-chain) IgG, to transfer the immune complex from the microplate wells to the modified polystyrene beads. Alternatively, modified polystyrene beads coated with (anti-2,4-dinitrophenyl group) IgG and microplate wells coated with (antihuman IgG gamma-chain) IgG were substituted for microplate wells coated with (anti-2,4-dinitrophenyl group) IgG and modified polystyrene beads coated with (antihuman IgG gamma-chain) IgG, respectively. The fluorescence intensity for bound beta-D-galactosidase activity was quickly measured with a fluororeader. Thus the modified polystyrene beads were transferred from wells to wells more quickly and easily without tweezers, eliminating false-positivity due to carryover, and it became easy to test many samples with high sensitivity and reliability, although the assay of bound beta-D-galactosidase activity became slightly more time-consuming.

Animals↗