Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators.

There is currently considerable interest in the wear debris and osteolytic potential of different types of bearings used in total joint replacements. The biological activity of the wear debris is dependent on the size and volume of the particles produced. Wear volume also plays an important role in the functional biological activity of a joint replacement. In vitro studies have shown that crosslinking of ultra high molecular weight polyethylene (UHMWPE) acetabular cups and tibial trays produces a reduction in wear volume, and crosslinking has now been introduced clinically for both types of prostheses. Previous studies have identified both micron and submicron-sized polyethylene wear particles. The aim of this study was to characterize the wear and wear particles generated from moderately crosslinked GUR 1,020 GVF UHMWPE acetabular cups and tibial trays in hip and knee joint wear simulators down to 10 nanometers in size. The wear rates of the two prosthesis types were very similar at 25.6 +/- 5.3 mm(3) per million cycles for the hip prostheses and 22.75 +/- 5.95 mm(3) per million cycles for the knee prostheses. Nanometer-sized wear particles were isolated and characterized from both hip and knee simulator lubricants for the first time. Significantly higher numbers (p < 0.05) of particles in the nanometer (<0.1 microm) size range were produced by the hip prostheses compared to the knee prostheses. The knee prostheses produced larger particles, with the mode of particle size in the 0.1-1.0 microm size range, compared to <0.1 microm size range for the hip prostheses. In addition, the knee prostheses produced a greater volumetric concentration of wear particles in the 1.0-10 microm size range, and consequently lower specific biological activity and functional biological activity indices. These results indicated that the knee prostheses had a lower osteolytic potential compared to the hip prostheses.

Biocompatible Materials↗

Tissue engineering of vascular conduits.

BACKGROUND: Autologous conduits are not available in up to 40 per cent of patients with arteriopathy who require coronary or lower limb revascularization, and access sites for renal dialysis may eventually become exhausted. Synthetic prostheses achieve a poor patency rate in small-calibre anastomoses. This review examines how vascular tissue engineering may be used to address these issues. METHODS: A Medline search was performed, using the keywords "vascular tissue engineering", "small diameter vascular conduit", "vascular cell biology", "biomechanics", "cell seeding" and "graft endothelialization". Key references were hand-searched for relevant papers. RESULTS AND CONCLUSION: In vitro and in vivo approaches are currently being used for guided cell repopulation of both biological and synthetic scaffolds. The major clinical problem has been extended culture time (approximately 6 weeks), which precludes their use in the acute setting. However, recent advances have led not only to improved patency rates for prostheses, but also to a potential reduction in culture time. In addition, increased mobilization of endothelial progenitor cells in the presence of ischaemic tissue may increase the autologous cell yield for scaffold reseeding with further reduction in culture time.

Bioartificial Organs↗

Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses.

The problems of osteolysis and late aseptic loosening associated with ultra-high molecular weight polyethylene (UHMWPE) particles has lead to a renewed interest in metal-on-metal prostheses. Wear particles generated by modern Co-Cr-on-Co-Cr prostheses are nanometre in size (range: 10-120 nm; mean: about 40 nm), an order of magnitude smaller than the size of UHMWPE known to be critical for activation of osteolytic cytokines by macrophages. Co-Cr wear particles will induce osteolytic cytokine production by human macrophages, but only at high volumetric concentrations. Unlike UHMWPE, Co-Cr particles are not inert. Co-Cr particles have the potential to release metal ions; they may be toxic to cells, induce deoxyribonucleic acid damage or cause host hypersensitivity. The nanometre size range of Co-Cr wear particles means that they may be disseminated widely in the body. The potential for metal-on-metal bearings to induce adverse effects clinically will be dependent upon the rate of wear. What constitutes a safe wear rate for modern metal-on-metal bearings is unknown. However, the wear of metal-on-metal prostheses is critically dependent upon the design and, in particular, the carbon content of the alloy, the radial clearance, and the head diameter. Thus, the potential for adverse biological reactions associated with metal-on-metal bearings can be reduced by selection of appropriately designed implants.

Chromium Alloys↗

Influence of hyaluronic acid on the time-dependent friction response of articular cartilage under different conditions.

Therapeutic lubricant injections of hyaluronic acid are a relatively recent treatment for osteoarthritis. Their efficacy, however, in vivo has been subject to much debate. Frictional properties of cartilage-cartilage contacts under both static and dynamic loading conditions have been investigated, using healthy cartilage and cartilage with a physically disrupted surface, with and without the addition of a therapeutic lubricant, hyaluronic acid. Most of the cartilage friction models produced typical time-dependent loading curves, with a rise in static friction with loading time. For the dynamic loading conditions the rise in friction with loading time was dependent on the spatial (and time) variation in the load on the cartilage plate. For sliding distances of 4 mm or greater, when the cartilage plate was unloaded during sliding, the dynamic friction remained low whereas, with shorter sliding distances, the dynamic friction increased with increasing loading time. Static friction was higher than dynamic friction (under the same tribological conditions). The 'damaged' cartilage models produced higher friction than healthy cartilage under equivalent tribological conditions. It was shown that hyaluronic acid was an effective boundary lubricant for articular cartilage under static conditions with both healthy and damaged cartilage surfaces. Hyaluronic acid was less effective under dynamic conditions. However, these dynamic conditions had low friction values with the control lubricant because of the effectiveness of the intrinsic biphasic lubrication of the cartilage. It was only under the tribological conditions in which the cartilage friction was higher and rising with increasing loading time because of depletion of the intrinsic biphasic lubrication, that the role of hyaluronic acid as an effective therapeutic lubricant was demonstrated.

Animals↗

The role of the surface amorphous layer of articular cartilage in joint lubrication.

Articular cartilage is a complex soft tissue that performs multiple functions in the joint. In particular, the amorphous layer that covers the surface of articular cartilage is thought to play some role in lubrication. This study aimed to characterize the surface amorphous layer (SAL) using a variety of techniques, including environmental scanning electron microscopy, transmission electron microscopy, white light interferometry, and biochemical analysis of its composition. Friction tests were conducted to investigate the role of the SAL in lubrication. A protocol to remove successfully the SAL without damaging the underlying cartilage was developed and the material removed from healthy cartilage was found to contain approximately equal quantities of glycosaminoglycan (GAG), protein, and lipid. Cartilage-on-cartilage friction tests were conducted on fresh, healthy cartilage with and without the SAL, under both dynamic and static operating conditions. Removal of the SAL was not found to change the friction coefficient. However, subsequent staining of specimens indicated that the SAL had replenished during the test following loading. The replenished SAL was characterized and found to contain lipids and sulphated GAGs with undetectable protein. This study revealed experimental evidence of surface layer replenishment in articular cartilage. It was postulated that the surface layer regeneration mechanism was purely mechanical and associated with movement of GAGs and lipids through the cartilage matrix during deformation, since the experimental set-up did not contain any means of biochemical activation.

Animals↗

The internal dynamic modes of charged self-assembled peptide fibrils.

Photon correlation spectroscopy is used to study the internal dynamics of self-assembled charged peptide fibrils. Short neutral and charged polymeric aggregates have diffusive modes due to whole macromolecular motion. For long semiflexible fibrils the logarithm of the intermediate scattering function follows a q(2)t(3/4) scaling at long times consistent with a Kratky-Porod free energy and preaveraged Oseen hydrodynamics. Persistence lengths on the order of micrometers are calculated for the peptide fibrils consistent with estimates from the liquid-crystalline phase behavior. Fibril diameters (5-35 nm) calculated from the initial decay of the correlation functions are in agreement with transmission electron microscopy measurements.

Algorithms↗

Influences of sterilising techniques on polyethylene wear.

Over the last 10 years there has been increasing concern over wear of polyethylene and osteolytic potential in the knee. During this period there have been considerable developments in both the design, materials and sterilisation techniques used for polyethylene in the knee. This paper reviews wear performance of polyethylene sterilised by different techniques, under a range of kinematics conditions in a single knee joint simulator system. Reducations in polyethylene wear were found with both stabilised polyethylene and cross-linked polyethylene, and with rotating platform mobile bearing designs.

Biomechanical Phenomena↗

Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris.

Ultra-high molecular weight polyethylene wear particles have been implicated as the major cause of osteolysis, implant loosening and late aseptic failure in total hip arthroplasties in vivo. This study initially screened 22 carbon-carbon composite materials as alternatives for UHMWPE in joint bearings. New bearing materials should satisfy certain criteria--they should have good wear properties that at least match UHMWPE, and produce wear particles with low levels of cytotoxic and osteolytic activity. Initial screening was based on wear resistance determined in short-term tribological pin-on-plate tests. Three materials (HMU-PP(s), HMU-RC-P(s), and SMS-RC-P(s)) which had superior wear resistance were selected for long-term testing. All materials had very low wear factors and SMS-RC-P(s), which had a wear factor of 0.08 +/- 0.56 x 10(-7) mm3/Nm, was selected for the subsequent biological testing and particle size analysis. SMS-RC-P(s) showed good biocompatibility in bulk material form and also the wear particles had low cytotoxicity for L929 fibroblasts in culture compared to metal wear particles. Wear debris size analysis by transmission electron microscopy showed that the particles were very small, with the vast majority being under 100 nm in size, similar to metal wear particles. The potential osteolytic effect of SMS-RC-P(s) wear particles was investigated by culturing particles with human peripheral blood mononuclear cells and measuring TNFalpha production. SMS-RC-P(s) did not significantly stimulate TNFalpha production at a particle volume to cell number ratio of 80:1, indicating that the debris had a low osteolytic potential. The results of this study suggest that carbon-carbon composites, particularly those composed of PAN-based fibers may be important biomaterials in the development of next generation bearing surfaces for use in total joint replacements that have very low wear rates and reduced osteolytic and cytotoxic potential.

Animals↗

Wear of surface engineered metal-on-metal hip prostheses.

The wear of existing metal-on-metal (MOM) hip prostheses (1 mm3/million cycles) is much lower than the more widely used polyethylene-on-metal bearings (30-100 mm3/million cycles). However, there remain some potential concerns about the toxicity of metal wear particles and elevated metal ion levels, both locally and systemically in the human body. The aim of this study was to investigate the wear, wear debris and ion release of fully coated surface engineered MOM bearings for hip prostheses. Using a physiological anatomical hip joint simulator, five different bearing systems involving three thick (8-12 microm) coatings, TiN, CrN and CrCN, and one thin (2 microm) coating diamond like carbon (DLC) were evaluated and compared to a clinically used MOM cobalt chrome alloy bearing couple. The overall wear rates of the surface engineered prostheses were at least 18-fold lower than the traditional MOM prostheses after 2 million cycles and 36-fold lower after 5 million cycles. Consequently, the volume of wear debris and the ion levels in the lubricants were substantially lower. These parameters were also much lower than in half coated (femoral heads only) systems that have been reported previously. The extremely low volume of wear debris and concentration of metal ions released by these surface engineered systems, especially with CrN and CrCN coatings, have considerable potential for the clinical application of this technology.

Biomedical Engineering↗

Proinflammatory cytokine production by human keratinocytes stimulated with Propionibacterium acnes and P. acnes GroEL.

BACKGROUND: Keratinocytes form the first line of defence in the skin and alert the host to danger by the production of a number of cytokines and chemokines. However, the interaction of commensal microorganisms with keratinocytes has not been well studied. OBJECTIVES: To investigate the effect of viable and nonviable cells of Propionibacterium acnes in both exponential and stationary growth phases, and of P. acnes GroEL on cytokine production by human primary keratinocytes. METHODS: Actively proliferating or contact-inhibited keratinocytes were cocultured with viable or formaldehyde-killed P. acnes cells in either the exponential or stationary phase of growth. Culture supernatants were assayed by enzyme-linked immunosorbent assay for the cytokines interleukin (IL)-1alpha, tumour necrosis factor (TNF)-alpha and granulocyte/macrophage colony-stimulating factor (GM-CSF). Keratinocytes were also stimulated with different concentrations of P. acnes GroEL and supernatants assayed for cytokines. RESULTS: Viable P. acnes in the stationary phase of growth stimulated keratinocyte monolayers to produce significantly higher amounts of IL-1alpha, TNF-alpha and GM-CSF than unstimulated keratinocytes. Viable exponential-phase bacteria stimulated production of significantly higher amounts of TNF-alpha and GM-CSF but these levels were significantly lower than those for stimulation with stationary-phase bacteria. Nonviable P. acnes from either growth phase was not able to stimulate cytokine production. P. acnes GroEL at concentrations in the range 0.05-1.0 micro g mL(-1) was able to induce increased production of cytokines by keratinocytes in a dose-dependent manner. This was analogous to stimulation with Escherichia coli GroEL. CONCLUSIONS: Stimulation of cytokine production by P. acnes and P. acnes GroEL may be important in the pathogenesis of inflammatory acne vulgaris and may have wider implications for the immunomodulation of the human immune system by commensal skin microorganisms.

Cell Division↗

Evidence for diversity within Propionibacterium acnes: a comparison of the T-cell stimulatory activity of isolates from inflammatory acne, endocarditis and the laboratory.

BACKGROUND: Propionibacterium acnes is primarily associated with the pathogenesis of acne vulgaris but reports are increasing in number implicating P. acnes in other diseases such as abscess formation, meningitis and endocarditis. The pathogenicity of P. acnes is thought to be partly due to the interaction of the bacterium with the immune system. Historically, investigations have focused on humoral and cell-mediated immune responses to P. acnes antigens without attention to the possibility that different antigens may be expressed by different isolates. OBJECTIVE: Investigations were performed to determine whether there were differences between a laboratory strain of P. acnes (P-37) and fresh clinical isolates in their ability to stimulate naive and adult lymphocytes. MATERIAL AND METHODS: The fresh isolates were collected from a patient with inflammatory acne and a patient with P. acnes-induced prosthetic valve endocarditis. The lymphocyte transformation assay was used to detect responses to whole-cell suspensions of stationary phase P. acnes isolates during 7 days of incubation. RESULTS: The acne isolate was significantly more stimulatory for cord blood mononuclear cells (CBMNCs) than the laboratory isolate (P. acnes P-37) at day 4 of incubation. There were no significant differences between the three strains at any other time points. However, the isolate cultivated from inflammatory acne was significantly more stimulatory for peripheral blood mononuclear cells (PBMNCs) from acne donors than the endocarditis isolate or the laboratory strain at most time points. There were no significant differences between the endocarditis strain and the laboratory strain. CONCLUSION: It can be hypothesized that in case of P. acnes-induced endocarditis lymphocyte stimulation is a disadvantage for the microorganism and therefore a lack of lymphocyte stimulation may be relevant to the pathogenesis of endocarditis.

Acne Vulgaris↗

Biological response to wear debris generated in carbon based composites as potential bearing surfaces for artificial hip joints.

UHMWPE wear particles have been implicated in osteolysis, implant loosening, and long-term failure of total hip arthroplasties in vivo. This study examined four carbon-based composite materials as alternatives for UHMWPE in joint bearings. These materials were HMU-CVD, SMS-CVD, P25-CVD, and CFR-PEEK. New bearing materials should satisfy certain criteria: they should have good wear properties that at least match UHMWPE, and produce wear particles with low levels of biological activity. Of the four materials tested in multidirectional pin-on-plate tribological tests, SMS-CVD, P25-CVD, and CFR-PEEK showed lower volumetric wear factors than UHMWPE. P25-CVD had the lowest wear factor of 0.54 +/- 0.34 x 10(-7) mm(3)/Nm. Analysis of P25-CVD wear particles by transmission electron microscopy showed that the debris was very small, with the vast majority of particles being under 100 nm in size, which was similar in size to metal wear particles. The P25-CVD particles were isolated and cultured with L929 fibroblasts and U937 monocytic cells to assess their effect on cell viability. P25-CVD particles were significantly less cytotoxic (p < 0.01, ANOVA) to both cell types than CoCr metal wear particles. This work suggests that carbon-carbon composite materials may have potential for use in total hip replacement bearings. Of the materials tested P25-CVD had the lowest wear factor, and produced very small wear debris that had minimal cytotoxic effect on L929 and U937 cells in vitro. Therefore carbon-carbon composites, such as P25-CVD, may be important in the development of next-generation implants with lower wear rates and reduced cytotoxic potential.

Animals↗

Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro.

Concern over polyethylene wear particle induced aseptic loosening of metal-on-polyethylene hip prostheses has led to renewed interest in alternative materials such as metal-on-metal and alumina ceramic-on-alumina ceramic for total hip replacement. This study compared the effects of clinically relevant cobalt-chromium and alumina ceramic wear particles on the viability of U937 histiocytes and L929 fibroblasts in vitro. Clinically relevant cobalt-chromium wear particles were generated using a flat pin-on-plate tribometer. The mean size of the clinically relevant metal particles was 29.5+/-6.3 nm (range 5-200 nm). Clinically relevant alumina ceramic particles were generated in the Leeds MkII anatomical hip simulator from a Mittelmieier prosthesis using micro-separation motion. This produced particles with a bimodal size distribution. The majority (98%) of the clinically relevant alumina ceramic wear debris was 5-20 nm in size. The cytotoxicity of the clinically relevant wear particles was compared to commercially available cobalt-chromium (9.87 microm+/-5.67) and alumina ceramic (0.503+/-0.19 microm) particles. The effects of the particles on the cells over a 5 day period at different particle volume (microm(3)) to cell number ratios were tested and viability determined using ATP-Lite(TM). Clinically relevant cobalt-chromium particles 50 and 5 microm(3) per cell reduced the viability of U937 cells by 97% and 42% and reduced the viability of L929 cells by 95% and 73%, respectively. At 50 microm(3) per cell, the clinically relevant ceramic particles reduced U937 cell viability by 18%. None of the other concentrations of the clinically relevant particles were toxic. The commercial cobalt-chromium and alumina particles did not affect the viability of either the U937 histiocytes or the L929 fibroblasts.Thus at equivalent particle volumes the clinically relevant cobalt-chromium particles were more toxic then the alumina ceramic particles. This study has emphasised the fact that the nature, size and volume of particles are important in assessing biological effects of wear debris on cells in vitro.

Aluminum↗

Effects of clinically relevant alumina ceramic wear particles on TNF-alpha production by human peripheral blood mononuclear phagocytes.

The recent introduction of microseparation of the components of ceramic-on-ceramic hip prostheses during hip simulations has produced clinically relevant wear rates, wear patterns and wear particles. This provided an opportunity to determine the response of primary human peripheral blood mononuclear cells to clinically relevant alumina ceramic wear particles in vitro. Alumina ceramic wear particles were generated in a hip joint simulator under microseparation conditions. The particles showed a bi-modal size distribution with nanometer sized (5-20nm) and larger particles (0.2->10 micrometer). The particles were cultured with human peripheral blood mononuclear cells obtained from six different donors at particle volume to cell number ratios of 1, 10, 100 and 500 micrometer(3). After 24h incubation the viability of the cells and the levels of TNF-alpha were determined. The response to the microseparation wear particles was compared to that of commercially available alumina powder with a uniform morphology and mean size of 0.5 micrometer. All six Donors PBMNC produced significantly elevated levels of TNF-alpha when stimulated with 100 micrometer(3) of the alumina powder per cell. Volumetric concentrations of 10 and 1.0 micrometer(3) per cell failed to stimulate a significant response by the cells from any of the six donors. Three of the six Donors PBMNC secreted significantly elevated levels of TNF-alpha when stimulated with 100 micrometer(3) of the microseparation wear particles, whereas the other three failed to respond to the wear debris at this concentration. All of the Donors PBMNC produced significantly elevated levels of TNF-alpha when stimulated with 500 micrometer(3) of the microseparation wear particles per cell. Thus, a greater volume of the microseparation wear particles was required to activate the PBMNC than the alumina powder. This was probably due to the microseparation wear particles having fewer particles in the critical size range (0.1-1 micrometer) for macrophage activation compared to the alumina powder. It can be concluded that alumina ceramic wear particles generated under microseparation conditions are capable of inducing osteolytic cytokine production by human mononuclear phagocytes. However, the volumetric concentration of the particles needed to generate this response is extremely high and given the low wear rates (<4mm(3) per million cycles) of ceramic-on-ceramic bearings, even under severe microseparation conditions, it is unlikely that this concentration threshold will be achieved in vivo.

Aluminum↗

Assessment of the biological properties of human split skin allografts disinfected with peracetic acid and preserved in glycerol.

Skin allografts derived from cadaveric human donors are widely used in the treatment of serious burn injuries and other conditions, such as ulcers. In order to render these allografts safe for clinical use, and to enable them to be preserved and banked for long periods, effective methods of decontamination and preservation are required. These methods must not adversely affect graft properties essential for clinical performance. We have investigated the application of a peracetic acid (PAA) disinfection protocol, coupled with preservation in either glycerol or propylene glycol to achieve these goals. An effective decontamination procedure, comprising of a 3h exposure to 0.1% (v/v) PAA in phosphate buffered saline (PBS) at pH 7.0, was developed and had no significant detrimental effects on the structure of skin. Cadaveric skin allografts were then treated with this disinfection protocol and subsequently preserved in either 85% (v/v) glycerol or propylene glycol in PBS, and the biological properties of the allografts thought to be essential to successful clinical performance were assessed. The cytotoxicity of the grafts was assessed using both extract and contact assays; damage to the skin collagen was assessed using a collagenase susceptibility assay and the capacity of the grafts to elicit an inflammatory response in vitro was assessed by quantifying the production of the pro-inflammatory cytokine TNF-alpha by human peripheral blood mononuclear phagocytes. Neither the disinfection protocol nor either of the preservation techniques rendered the grafts cytotoxic or pro-inflammatory. The PAA disinfection and glycerol preservation protocol had no effects on collagenase susceptibility, whereas the disinfection protocol in combination with propylene glycol rendered some of the test samples significantly more susceptible to collagenase digestion. Therefore, this study has demonstrated that PAA disinfection combined with glycerol preservation is suitable for skin allografts. The use of propylene glycol as a preservation agent for skin requires further development.

Bacillus subtilis↗

Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.

Wear of polyethylene and the resulting wear debris-induced osteolysis remains a major cause of long-term failure in artificial hip joints. There is interest in understanding engineering and clinical conditions that influence wear rates. Fluoroscopic studies have shown separation of the head and the cup during the swing phase of walking due to joint laxity. In ceramic-on-ceramic hips, joint laxity and microseparation, which leads to contact of the head on the superior rim of the cup, has led to localized damage and increased wear in vivo and in vitro. The aim of this study was to investigate the influence of joint laxity and microseparation on the wear of ceramic on polyethylene artificial hip joints in an in vitro simulator. Microseparation during the swing phase of the walking cycle produced contact of the ceramic head on the rim of the polyethylene acetabular cup that deformed the softer polyethylene cup. No damage to the alumina ceramic femoral head was found. Under standard simulator conditions the volume change of the moderately crosslinked polyethylene cups was 25.6 +/- 5.3 mm3/million cycles and this reduced to 5.6 +/- 4.2 mm3/million cycles under microseparation conditions. Testing under microseparation conditions caused the rim of the polyethylene cup to deform locally, possibly due to creep, and the volume change of the polyethylene cup when the head relocated was substantially reduced, possibly due to improved lubrication. Joint laxity may be caused by poor soft tissue tension or migration and subsidence of components. In ceramic-on-polyethylene acetabular cups wear was decreased with a small degree of joint laxity, while in contrast in hard-on-hard alumina bearings, microseparation accelerated wear. These findings may have significant implications for the choice of fixation systems to be used for different types of bearing couples.

Ceramics↗

In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements.

Extremely low wear rates have been reported for metal-on-metal total hip replacements, but concerns remain about the effects of metal ion release, dissolution rates and toxicity. Surface-engineered coatings have the potential to improve wear resistance and reduce the biological activity of the wear debris produced. The aim of this study was to examine the wear and wear debris generation from surface-engineered coatings: titanium nitride (TiN), chromium nitride (CrN) and chromium carbon nitride (CrCN) applied to a cobalt-chrome alloy (CoCr) substrate. The coatings were articulated against themselves in a simple geometry model. The wear particles generated were characterized and the cytotoxic effect on U937 macrophages and L929 fibroblasts assessed. The CrN and CrCN coatings showed a decrease in wear compared to the CoCr bearings and produced small (less than 40 nm in length) wear particles. The wear particles released from the surface engineered bearings also showed a decreased cytotoxic effect on cells compared to the CoCr alloy debris. The reduced wear volumes coupled with the reduced cytotoxicity per unit volume of wear indicate the potential for the clinical application of this technology.

Cell Survival↗

Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision.

The aims of this study were to investigate the tissues from uncemented Mittelmeier alumina ceramic-on-ceramic total hip replacements using histological methods and to isolate and characterise the ceramic wear debris using laser capture microdissection and electron microscopy. Tissues from around 10 non-cemented Mittelmeier alumina ceramic on ceramic THRs were obtained from patients undergoing revision surgery. Tissues were also obtained from six patients who were undergoing revisions for aseptic loosening of Charnley, metal-on-polyethylene prostheses. Tissue sections were analysed using light microscopy to determine histological reactions and also the location and content of alumina ceramic wear debris. Tissue samples were extracted from sections using laser capture microdissection and the characteristics of the particles subsequently analysed by TEM and SEM. The tissues from around the ceramic-on-ceramic prostheses all demonstrated the presence of particles, which could be seen as agglomerates inside cells or in distinct channels in the tissues. The tissues from the ceramic-on-ceramic retrievals had a mixed pathology with areas that had no obvious pathology, areas that were relatively rich in macrophages and over half of the tissues had in the region of 60% necrosis/necrobiosis. In comparison, the Charnley tissues showed a granulomatous cellular reaction involving a dense macrophage infiltrate and the presence of giant cells and < 30% necrosis/necrobiosis. The tissues from the ceramic prostheses also showed the presence of neutrophils and lymphocytes, which were not evident in the tissues from the Charnley retrievals. There were significantly more macrophages (p < 0.05), and giant cells (p < 0.01) in the Charnley tissues and significantly more neutrophils (p < 0.01) in the ceramic-on-ceramic tissues. TEM of the laser captured tissue revealed the presence of very small alumina wear debris in the size range 5-90 nm, mean size + SD of 24 +/- 19nm whereas SEM (lower resolution) revealed particles in the 0.05-3.2 microm size range. This is the first description of nanometre sized ceramic wear particles in retrieval tissues. The bi-modal size range of alumina ceramic wear debris overlapped with the size ranges commonly observed with metal particles (10-30 nm) and particles of ultra-high molecular weight polyethylene (0.1-1,000 microm). It is possible that the two size ranges of contributed to the mixed tissue pathology observed. It is speculated that the two types of ceramic wear debris are generated by two different wear mechanisms in vivo, under normal articulating conditions, relief polishing wear and very small wear debris is produced. while under conditions of microseparation of the head and cup and rim contact, intergranular and intragranular fracture and larger wear particles are generated.

Aluminum Oxide↗