Effects of voltage and respiration on impedance in nonthoracotomy defibrillation pathways.

The effects of applied voltage and phase of respiration on impedance of pathways used by implantable cardioverter-defibrillators were investigated. Patients were studied at implantation of cardioverter-defibrillators using epicardial (n = 12) or transvenous and subcutaneous (SQ) (n = 30) electrodes. Transvenous-SQ pathways were right ventricular cathode to SQ anode and coronary sinus cathode to SQ anode. Transvenous-transvenous pathways were right ventricle to coronary sinus and right ventricle to superior vena cava. Patients with nonthoracotomy electrode systems were studied at end-expiration and end-inspiration. Five shocks of 65 to 745 V (0.2 to 34 J) were given in random order in sinus rhythm. Over this range, end-expiratory impedance decreased monotonically for all pathways. This effect was greatest for transvenous-SQ pathways (13 +/- 3% to 17 +/- 4%, p < 0.001), intermediate for transvenous-transvenous pathways (5 +/- 4% to 8 +/- 5%, p < 0.001), and least for epicardial pathways (3 +/- 3%, p = 0.006). Paired data in inspiration and expiration showed that inspiration increased impedance in transvenous-SQ pathways (p < 0.001) but not in transvenous-transvenous pathways. Further, the effects of respiration and voltage on impedance in transvenous-SQ pathways were interactive (p < 0.001): Inspiration increased voltage-dependence of impedance. The magnitude of the inverse relationship between voltage and impedance depends on type of defibrillation pathway. The effect of respiration on impedance suggests that voltage-dependence of impedance is greatest in the lungs. These findings have potential relevance for intraoperative testing of cardioverter-defibrillators and selection of pathways for low-energy cardioversion.

Aged↗

Underdetection of ventricular tachycardia by algorithms to enhance specificity in a tiered-therapy cardioverter-defibrillator.

OBJECTIVES: The goal of this study was to determine the incidence and clinical significance of underdetection in 125 patients treated with a tiered-therapy cardioverter-defibrillator, the Medtronic PCD. BACKGROUND: Underdetection, distinct from undersensing, is a unique, potential complication of new algorithms that enhance specificity in tiered-therapy cardioverter-defibrillators. These algorithms may delay or prevent recognition of ventricular tachycardia even though electrograms are sensed accurately and RR intervals meet the programmed interval criterion. METHODS: Underdetection was defined as delay in detection > 5 s at electrophysiologic study or symptomatic delay or detection failure at follow-up of 15 +/- 8 months. RESULTS: We identified six specific mechanisms of underdetection caused by algorithms to discriminate sustained ventricular tachycardia from sinus tachycardia, atrial fibrillation, ventricular fibrillation and nonsustained ventricular tachycardia. Underdetection caused detection delays in 13 (1.9%) of 677 induced ventricular tachyarrhythmia episodes in 12 patients (9.6%). During follow-up, underdetection occurred in 7 (9.9%) of 71 patients in whom ventricular tachycardia therapies were programmed. Failure to detect ventricular tachycardia occurred in 6 (0.6%) of 988 spontaneous ventricular tachycardia episodes in four patients (5.6%); 2 episodes required external cardioversion. After defibrillator reprogramming, underdetection did not occur. CONCLUSIONS: Algorithms to enhance specificity cause underdetection of ventricular tachycardia in a significant minority of patients with tiered-therapy cardioverter-defibrillators. Optimal programming can minimize underdetection.

Algorithms↗

High dose oral amiodarone loading: electrophysiologic effects and clinical tolerance.

Although amiodarone is an effective drug for the treatment of life-threatening ventricular arrhythmias, no standard oral loading dose protocol has been defined, and patients often undergo prolonged hospitalization for amiodarone loading. High dose (greater than 1,800 mg/day) oral loading has usually been reserved for unstable patients with incessant ventricular tachyarrhythmias. The current study was designed to 1) examine the clinical and electrophysiologic effects of a high dose oral amiodarone loading regimen in more stable patients; and 2) ascertain its safety and tolerance, possibly allowing shortened amiodarone loading periods and potentially decreased length of hospital stay. The study group included 16 patients with a history of recurrent ventricular arrhythmias and decreased left ventricular function, who were refractory to prior antiarrhythmic drug therapy. The oral loading protocol was 50 mg/kg per day of amiodarone for 3 days, then 30 mg/kg per day for 2 days, followed by maintenance therapy of 300 to 400 mg twice daily. Electrophysiologic testing was performed at baseline, on days 1 and 5 and during week 6. Amiodarone and desethylamiodarone levels were measured and symptoms monitored. Clinically, the high dose loading protocol was well tolerated in 15 of the 16 patients. Arrhythmias were rendered noninducible by day 1 in three patients and remained noninducible throughout the study period in two of the three. The remaining patients continued to have inducible ventricular tachycardia. Ventricular tachycardia cycle length and right ventricular effective refractory period both progressively increased significantly over baseline, starting on day 1. The 15 patients who remained in the study had no significant side effects during the loading period.(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Oral↗

Syncope of unknown origin: clinical, noninvasive, and electrophysiologic determinants of arrhythmia induction and symptom recurrence during long-term follow-up.

Ninety-one consecutive patients with syncope of unknown origin underwent electrophysiologic studies (EPS). Univariate analysis identified the following variables: age, + signal-averaged ECG (SAECG), left ventricular ejection fraction (LVEF), history of myocardial infarction, coronary artery disease, left ventricular aneurysm, and history of sustained monomorphic ventricular tachycardia (SMVT) on Holter; multivariate analysis identified +SAECG, LVEF, and history of SMVT as risk factors for induction of SMVT at EPS. All patients were followed up for 19.0 +/- 8.3 months and 17 had recurrence of syncope. Patients were divided into empiric, EP-guided, and no therapy groups. The EP-guided therapy group included all patients with SMVT at EPS. Recurrence rates among all three groups were similar. We conclude that: (1) Patients who have inducible SMVT at EPS can be identified using certain clinical and noninvasive variables. When these patients undergo EP-guided therapy, their rate of recurrence of syncope becomes compatible with that of patients who had no arrhythmia induced at EPS. (2) Empiric therapy does not offer any benefit over no therapy in reducing the rate of recurrent of scope.

Aged↗

[Prevalence of late potentials in acute myocardial infarction and its relation to ventricular arrhythmias in early period of acute myocardial infarction (AMI)].

The prevalence of ventricular late potentials (LP) in acute myocardial infarction (AMI) and the relationship between the presence of LP and the occurrence of spontaneous sustained ventricular tachycardia (VT) or fibrillation (VE) in the early phase (within 10 days) of AMI were studied. A total of 251 consecutive patients who had an uninterrupted natural history before special treatment formed this study. Sustained VT or VF occurred in 20 patients (8%). LP were recorded in 67 patients (27%). The incidence of LP was significantly higher among patients with VT/VF than among those without VT/VF (12 of 20, or 60%, vs 55 of 231, or 24%, P less than 0.01). The subgroup of patients whose VT/VF occurred within 1 hour of onset of AMI also showed a higher incidence of LP (5 of 9, or 56%, vs 55 of 231, or 24%, P less than 0.05). The results showed that the mechanism of VT/VF in early period including those happened within 1 hour of onset of AMI in man is due to reentry, and that LP can help to identify those high risk patients with a propensity to develop VT/VF in early period of AMI.

Electrocardiography↗

Electrical safety during electrophysiological testing.

This report describes the inadvertent induction of non-sustained atrial and ventricular arrhythmias due to the malfunction of a programmable cardiac stimulator. The malfunction occurred when line power resumed after a brief municipal power outage ("blackout") during an invasive electrophysiological study. The stimulator spontaneously delivered very high frequency pulses through the electrode catheter to the myocardium which resulted in atrial and ventricular arrhythmias. During bench testing, the stimulator delivered a continuous train of high frequency output pulses (greater than or equal to 1 mA) when line voltage resumed normal level after it had dropped below 65 VAC. Electrical safety during electrophysiological testing requires a stimulator design which is immune to altered operating conditions, and which shuts down if abnormal operating or output conditions are detected.

Arrhythmias, Cardiac↗

Indirectly estimated sinoatrial conduction time by the atrial premature stimulus technique: patterns of error and the degree of associated inaccuracy as assessed by direct sinus node electrography.

The atrial premature stimulus method for estimating sinoatrial conduction time (SACT) is commonly used. When the stimulated atrial premature depolarization (APD) does not appear to affect sinus node automaticity or conduction, the indirectly estimated SACT (SACT1) is quite accurate. That is, SACT1 correlates quite highly with SACT measured directly (SACTD) on sinus node electrograms (SNE). In this study we used direct SNE recordings in 17 patients to assess SACT1 when factors thought to produce inaccuracy in SACT1 were present. Three patients had sinoatrial entrance block, which might make some expect sinoatrial exit delay to be present. However, SACTD was normal in two (60 and 70 msec) and prolonged (130 msec) only in the one who had other evidence of sinus node dysfunction. Therefore, sinoatrial entrance block does not necessarily indicate sinoatrial exit delay. Thirteen patients had apparent depression of sinus node automaticity by the induced APD (A3A4 greater than A1A1). In all 13, SACT1 overestimated SACTD. One patient had apparent sinoatrial conduction delay induced by the APD and/or vagal transmitter release induced by the APD. In this patient, too, SACT1 exceeded SACTD. Thus when sinoatrial automaticity or conduction are depressed by the stimulated APD, SACT1 will overestimate SACTD. If SACT1 is normal, SACTD will be normal; however, if SACT1 is prolonged, SACTD may or may not be prolonged.

Aged↗

Sinus node recovery time related to paced cycle length in normals and patients with sinoatrial dysfunction.

Depressed conduction in the sinoatrial junction, common in the sick sinus syndrome (SSS), should decrease the maximum pacing rate at which 1:1 capture of the SA node occurs. This may result in shorter than expected sinus recovery times (SRT) and maximal prolongation of SRT at relatively slow pacing rates. To test this hypothesis we evaluated the range of pacing rates necessary to demonstrate maximal SRT in 34 patients with and 20 patients without sinus node dysfunction. Atrial pacing was performed at multiple paced cycle lengths (PCL) between 400 and greater than or equal to 1000 msec, four times at each. A mean corrected SRT (CSRT) was determined at each PCL, and the PCL of the longest CSRT was determined (PCLp). PCLp varied linearly with sinus cycle length, was dependent on sinoatrial conduction time, and was longer in patients with SSS than in normal persons. Only 2 of 20 normal persons, but 21 of 34 patients with SSS, had a PCLp greater than 600 msec. A long PCLp (greater than 600 msec) suggests the possibility of recovery times that have been limited by A-S entrance block and appears to be indicative of sinus node dysfunction.

Arrhythmias, Cardiac↗

Electrophysiologic effects of procainamide on sinus function in patients with and without sinus node disease.

To compare the effects of procainamide on sinus node (SN) function in the presence (seven patients) and absence (nine patients) of SN dysfunction, sinus cycle length (SCL), maximal corrected sinus recovery time (maximal CRST), paced cycle length yielding peak SN suppression (PCLp), and indirect sinoatrial conduction time (SACT) were determined before and after intravenous administration of 10 to 15 mg/kg procainamide in each patient. Plasma procainamide concentration was in the therapeutic range in all patients. The mean SCL did not change significantly in either group (-24 +/- 58 and -73 +/- 171 msec for patients with normal and abnormal SN function, respectively). The maximal CSRT shortened 136 +/- 112 msec (p less than 0.01) in the group with normal SN function (nine of nine patients)( but tended to lengthen 85 +/- 95 msec (p less than 0.10) in the group with SN dysfunction (six of seven patients). PCLp shortened in only two of nine of the normal group but tended (NS) to shorten in five of seven patients with SN dysfunction. We conclude that in the absence of SN disease, procainamide does not adversely affect SN function. In apparent contrast in patients with SN dysfunction, procainamide tended (NS) to prolong CSRT and seemed (NS) to enhance conduction in the sinoatrial junction (PCLp and SACT both declined). The occasional lengthening of CSRT implies that procainamide might prolong post-tachycardia pauses and thus could worsen symptoms in certain patients with the bradycardia-tachycardia syndrome.

Adult↗

Clinical and electrophysiologic characteristics of sinoatrial entrance block evaluated by direct sinus node electrography: prevalence, relation to antegrade sinoatrial conduction time, and relevance to sinus node disease.

When AV conduction is normal, the absence of VA conduction is not abnormal. Analogous information about retrograde sinoatrial conduction is not available. Although the premature atrial stimulas (PAS) technique can demonstrate the presence of sinoatrial entrance block (SAEB), both its prevalence and its relationship to antegrade SA conduction are unknown. Using PAS, we determined the incidence of SAEB in 59 patients with known or suspected dysrrhythmias or conduction defects to be 6.8%. Using catheter recorded sinus node electrograms (SNE), we then directly measured sinoatrial conduction time (SACT) in three patients with SAEB. Antegrade SACT was normal in two and prolonged in one. Only the latter had sinus node dysfunction recognized by ECG and/or conventional sinus node testing. We conclude that SAEB occurs infrequently, may occur when antegrade SACT is normal, is probably analogous to behavior at the AV node, and should not be used as an indicator of sick sinus syndrome.

Adolescent↗

The human sinus node electrogram: a transvenous catheter technique and a comparison of directly measured and indirectly estimated sinoatrial conduction time in adults.

To improve methods for evaluating human sinus node function (SNF), we developed a transvenous electrode catheter technique for direct recording of sinus node electrograms in adults. Sinus node electrograms (SNE) characterized by low-frequency, anatomically localized pre-P-wave potentials were obtained in 19 of 23 patients. The SNE configuration was similar to that previously found for endocardial SNE recordings in in vitro atrial preparations, in open-chest dogs and during human open heart surgery. In 16 patients with normal SNF, directly recorded sinoatrial conduction times (SACTs) were 46-116 msec. In three patients with sick sinus syndrome, SACT was 110-126 msec. In 15 of the 19 patients, SACT was estimated by the atrial premature stimulus technique and was compared with the directly measured SACT. When atrial premature depolarizations produced no sinus node depression, the mean differences between the direct and estimated SACT was 1.8 +/- 5.6 msec.

Adult↗