Search PubMed⌕ Search

Biomedical subjects

E Frigerio

Publications and source records attributed to E Frigerio.

At least 19 recordsLinked to original sources

Bioanalytical method validation: a risk-based approach?

Bioanalysis frequently involves the measurement of very low analyte concentrations in complex and potentially variable matrices. It is not possible to test in validation every possible circumstance that may be encountered when analyzing study samples; logically, therefore, some risk of obtaining erroneous results exists when validated methods are applied to study samples. An initial attempt has been made to apply a risk management tool to the bioanalytical situation, with the hope that this will stimulate further discussion on the idea of more formally addressing "risk" with regards to bioanalytical method validation.

Biological Assay↗

Quantitation of SU1 1248, an oral multi-target tyrosine kinase inhibitor, and its metabolite in monkey tissues by liquid chromatograph with tandem mass spectrometry following semi-automated liquid-liquid extraction.

SU11248 is a potent inhibitor of PDGFR, VEGFR, KIT, and Flt3, and is currently under Phase I clinical evaluation as an anticancer drug. A sensitive and specific analytical method for the quantitation of SU11248 and its metabolite in several monkey tissues (liver, kidney, brain and white fat) using LC-MS-MS following semi-automated liquid-liquid extraction (LLE) was developed and validated. Amounts of 50 mg of tissue were homogenized using an ultrasonic processor. After addition of the stable labelled internal standard (IS) and ammonium hydroxide (0.3%), samples were extracted with 2.5 ml of tert-butyl methyl ether. Following centrifugation, aliquots of 1.8 ml of the organic phase were transferred into a 96-well plate. The Packard Multiprobe II robotic liquid handler was used to perform all steps mentioned above. The organic phase was dried and the residue was reconstituted with 800 microl of 15 mM ammonium formate buffer solution (pH 3.25) using a Tomtec Quadra 96 workstation. Aliquots of 10 microl of the resulting solution were injected into the LC-MS-MS system. A Symmetry Shield C8 column (50 mm x 2.1 mm, 3.5 microm) was used to perform the chromatographic analysis. The mobile phase was 15 mM ammonium formate buffer solution (pH 3.25)-acetonitrile (74:26 (v/v)) with a flow-rate of 0.35 ml/min. Retention times of the metabolite and SU11248 were about 2.5 and 3.5 min, respectively. Total cycle time was 5 min. MS detection used the Applied Biosystems-MDS Sciex API 3000 with TurbolonSpray interface and multiple reaction monitoring (MRM) operated in positive ion mode. The method was validated for both compounds over the calibration range of about 2 and 2000 ng/g. The suitability and robustness of the method for in vivo samples were confirmed by analysis of monkey tissues from animals dosed with SU11248.

Animals↗

Determination of PNU-248686A, a novel matrix metalloproteinase inhibitor, in human plasma by liquid chromatography-tandem mass spectrometry, following protein precipitation in the 96-well plate format.

A sensitive, specific and high-throughput analytical method for the quantitation of PNU-248686A (I), in human plasma has been developed. I, sodium (2R)-3-[[(4'-chloro(1,1'-biphenyl)-4-yl]sulfonyl]-2-hydroxy-2-[(phenylsulfanyl)methyl] propanoate, is an orally active matrix metalloproteinase (MMP) inhibitor developed for the treatment of solid tumors over-expressing MMPs. Concentrations of I, as free acid, were determined in human plasma by LC-MS-MS after plasma protein precipitation in the 96-well plate format. Aliquots of plasma (50 microl) were placed into the plates and 0.2 ml of methanol was added. The plates were shaken for 5 min and centrifuged at 1500 g for 10 min. Aliquots of 10 microl of the supernatants were then directly injected into the LC-MS-MS system. A Symmetry Shield C. column (50 x 2.1 mm, 3.5 microm) was used to perform the chromatographic analysis. The mobile phase was 5 mM ammonium formate buffer solution pH 5.0-acetonitrile (60:40. v/v) with a flow-rate of 0.3 ml/min. Retention time of I was about 1.2 min. Total cycle time was 2.5 min. MS detection used the Applied Biosystems-MDS Sciex API 3000 with TurbolonSpray interface and single reaction monitoring (461 --> 251 m/z transition) operated in negative ion mode. Calibration curves were constructed by plotting the area of the compound (y) against its concentration (x). A weighed linear regression (weighting factor 1/x(2)) was used to calculate I concentrations in quality control and unknown samples. The method was fully validated over the range of 5.0-5000 ng/ml. The suitability and robustness of the method for in vivo samples was confirmed by analysis of plasma samples from a pilot clinical study.

Biphenyl Compounds↗

LC-MS-MS determination of nemorubicin (methoxymorpholinyldoxorubicin, PNU-152243A) and its 13-OH metabolite (PNU-155051A) in human plasma.

A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for quantitative determination of nemorubicin, (PNU-152243A, 3'-deamino-3'[2(S)-methoxy-4-morpholinyl]doxorubicin) hydrocloride and its reduced metabolite PNU-155051 in human plasma has been developed and validated. The method involved solid phase extraction (SPE) in 96-well plates. Plasma samples (0.5 ml plasma, spiked with doxorubicin as internal standard and diluted with 0.5 ml of 0.01 M borate buffer, pH 8.4) were extracted using Oasis HLB SPE material. The elution of PNU-152243, PNU-155051 and of IS was performed with 1 ml of methanol:0.1 M formic acid mixture (90:10, v/v). The organic phase was reduced to dryness under a stream of nitrogen at 20 degrees C and the residue was reconstituted with 0.25 ml of 10 mM ammonium formate buffer pH 4.15:acetonitrile mixture (90:10, v/v). Aliquots of 60 microl of the resulting solution were injected onto the LC-MS-MS system. A Zorbax SB C18 column (2.1 x 150 mm, 3.5 microm) was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 10 mM pH 4.15:acetonitrile (73:27, v/v) with a flow-rate of 0.2 ml/min. Detection was achieved by a PE-SCIEX API 3000 with Turbo IonSpray interface, and multiple reaction monitoring (645 --> 321 for PNU-152243, 647 --> 363 for PNU-155051 and 545 --> 345 m/z for doxorubicin) operated in positive ion mode. A weighted linear regression was used to calculate PNU-152243 and PNU-155051 concentrations in QC and unknown samples. Linearity, precision, accuracy and recovery of the method were evaluated over the concentration range of 0.1-5 ng/ml for both compounds. No interference from blank human plasma was observed. The suitability of the method for in vivo samples was assessed by the analysis of samples obtained from patients who had received a single intrahepatic artery dose of PNU-152243A.

Chromatography, Liquid↗

High-performance liquid chromatographic analysis for the determination of a novel polymer-bound camptothecin derivative (MAG-camptothecin) and free camptothecin in human plasma.

A selective HPLC assay is described for the determination of free and total (free plus polymer-bound) camptothecin (CPT) in human plasma after administration of the anti-tumor drug MAG-CPT (polymer bound camptothecin). Total CPT levels were determined after hydrolysis and free CPT was extracted from acidified plasma using Oasis solid-phase extraction material. Extracts were analyzed on a Zorbax SB-C8 analytical column, using a mixture of acetonitrile-25 mM phosphate buffer (pH 4.0) as the eluent. Detection was performed fluorimetrically. Concentrations of polymer-bound CPT were calculated by subtraction of free from total CPT. The lower limits of quantitation of the methods were 100 ng/ml for total and 1.0 ng/ml for free CPT using 50 microl and 250 microl plasma, respectively. Special attention was paid to the stability of the analytes. The presented method was successfully applied in a clinical pharmacokinetic study in our institute.

Antineoplastic Agents, Phytogenic↗

Polymer-bound camptothecin: initial biodistribution and antitumour activity studies.

Camptothecin (CPT) is a potent, antitumour drug acting mainly through inhibition of topoisomerase I during the S-phase of the cell cycle. Despite its impressive antitumour activity, clinical development was halted for unpredictable toxic events. Two soluble N-(2-hydroxypropyl) methacrylamide (HPMA) copolymers were synthesised to contain CPT (5 wt.% and 10 wt.%). CPT was covalently linked at its alpha-hydroxyl group to the polymers through a Gly-Phe-Leu-Gly- spacer. In-vitro, CPT-conjugates were fairly resistant to hydrolysis in plasma as in buffer at neutral pH (0.2-0. 4% free CPT/h), while elastase and cysteine-proteases were able to release the active drug. Plasma levels in mice after intravenous administration of CPT-conjugates confirmed the modest hydrolysis in plasma. Plasma levels were approximately 5-fold lower than those observed at the highest tolerated dose of CPT administered in classical vehicles. Biodistribution in HT29 human colon carcinoma bearing mice was carried out after i.v. injection of [3H]CPT-conjugate and free [3H]CPT. Radioactivity uptake in tumour was evident only after [3H]CPT-conjugate treatment. Repeated intravenous administration of CPT-conjugates to HT29-bearing mice gave more than 90% tumour inhibition, some complete tumour regressions and no toxic deaths. The improved pharmacological profile on HT29 human colon carcinoma xenografts of the first poly(HPMA)-CPT conjugates might be ascribed to their prolonged intra-tumour retention and sustained release of the active drug.

Animals↗

LC-MS-MS determination of exemestane in human plasma with heated nebulizer interface following solid-phase extraction in the 96 well plate format.

A sensitive, specific and rapid analytical method for the quantitation of exemestane (EXE) in human plasma has been developed. EXE, 6-methylen-androsta-1,4-diene-3,17-dione, is an orally active irreversible steroidal aromatase inhibitor used for the therapy of metastatic postmenopausal breast cancer, with estrogen-dependent pathological conditions. The method involves extraction of EXE from human plasma by solid phase extraction using C2 endcapped sorbent in the 96 well plate format (50 mg/2 ml). After conditioning of the sorbent with 1 ml of acetonitrile (x2) the plates were rinsed with 1 ml of water (x2). The prepared samples (0.5 ml plasma, spiked with [13C3] EXE as internal standard (IS) and diluted with 0.5 ml water) were loaded and drawn through the plate with a minimum of vacuum. The plates were then washed with 1 ml acetonitrile:water (10:90) followed by a drying step for 30 min at full vacuum. Elution was by 0.15 ml of 0.1% trifluoracetic acid in acetonitrile (x2) under a minimum of vacuum. Aliquots of 80 microl were finally injected into the LC-MS-MS system. A Zorbax SB C8 column (4.6 x 150 mm, 5 microm) was used to perform the chromatographic separation; the mobile phase was 100% acetonitrile. MS detection used the heated nebulizer interface, with multiple reaction monitoring (MRM) (297-->121 m/z for EXE and 300-->123 m/z for IS) operated in positive ion mode. A weighed linear regression analysis (weighing factor 1/x2) was used to calculate EXE concentration in standard and unknown samples. The method was fully validated in the concentration range 0.05-25 ng ml(-1).

Androstadienes↗

Determination of MAG-camptothecin, a new polymer-bound camptothecin derivative, and free camptothecin in dog plasma by HPLC with fluorimetric detection.

A high throughput. selective and sensitive high-performance liquid chromatographic (HPLC) method for the determination of a water-soluble polymer-bound Camptothecin conjugate (MAG-CPT) and Camptothecin (CPT) in dog plasma has been developed and validated. The method involved the analysis of free and total CPT (free + polymer-bound). Free CPT (intact lactone plus carboxylate) was extracted from acidified plasma using Oasis SPE material in 96-well plates. For the assay of the total CPT, plasma proteins were first precipitated with methanol in a 96-well plate containing a 10-microm melt blown polypropylene membrane. The methanolic supernatant was separated and collected into a second 96-well plate by simply applying vacuum to the plate. After hydrolysis at pH 9.8 for 18 h and re-acidification, samples were injected directly from the collection plate onto the HPLC system. MAG-CPT concentration was then calculated by subtraction of free from total CPT. The LLOQs of the method were 1.17 ng/ml for free CPT and 103.10 ng/ml (as CPT equivalent) for MAG-CPT using 0.1 and 0.05 ml of plasma, respectively. Linearity, precision, accuracy and recovery of the method were evaluated. The stability of MAG-CPT in plasma alone and after its stabilisation was carefully evaluated. No interference from blank dog, mouse and human plasma was observed. The suitability of the method for in vivo samples was assessed by the analysis of samples obtained from dogs that had received a single and 5-day repeated dose of MAG-CPT.

Acrylamides↗

Population pharmacokinetics in phase I drug development: a phase I study of PK1 in patients with solid tumours.

Doxorubicin pharmacokinetics were determined in 33 patients with solid tumours who received intravenous doses of 20-320 mg m(-2) HPMA copolymer bound doxorubicin (PK1) in a phase I study. Since assay constraints limited the data at lower doses, conventional analysis was not feasible and a 'population approach' was used. Bound concentrations were best described by a biexponential model and further analyses revealed a small influence of dose or weight on V1 but no identifiable effects of age, body surface area, renal or hepatic function. The final model was: clearance (Q) 0.194 I h(-1); central compartment volume (V1) 4.48 x (1+0.00074 x dose (mg)) I; peripheral compartment volume (V2) 7.94 I; intercompartmental clearance 0.685 I h(-1). Distribution and elimination half-lives had median estimates of 2.7 h and 49 h respectively. Free doxorubicin was present at most sampling times with concentrations around 1000 times lower than bound doxorubicin values. Data were best described using a biexponential model and the following parameters were estimated: apparent clearance 180 I h-(-1); apparent V1 (I) 1450 x (1+0.0013 x dose (mg)), apparent V2 (I) 21 300 x (1-0.0013 x dose (mg)) x (1+2.95 x height (m)) and apparent Q 6950 I h(-1). Distribution and elimination half-lives were 0.13 h and 85 h respectively.

Adult↗

Phase I clinical and pharmacokinetic study of PK1 [N-(2-hydroxypropyl)methacrylamide copolymer doxorubicin]: first member of a new class of chemotherapeutic agents-drug-polymer conjugates. Cancer Research Campaign Phase I/II Committee.

PK1 comprises doxorubicin covalently bound to N-(2-hydroxypropyl)methacrylamide copolymer by a peptidyl linker. Following cellular uptake via pinocytosis, the linker is cleaved by lysosomal enzymes, allowing intratumoral drug release. Radically altered plasma and tumor pharmacokinetics, compared to free doxorubicin, and significant activity in animal tumors have been demonstrated preclinically. We aimed to determine the maximum tolerated dose, toxicity profile, and pharmacokinetics of PK1 as an i.v. infusion every 3 weeks to patients with refractory or resistant cancers. Altogether, 100 cycles were administered (range, 20-320 mg/m2 doxorubicin-equivalent) to 36 patients (20 males and 16 females) with a mean age of 58.3 years (age range, 34-72 years). The maximum tolerated dose was 320 mg/m2, and the dose-limiting toxicities were febrile neutropenia and mucositis. No congestive cardiac failure was seen despite individual cumulative doses up to 1680 mg/m2. Other anthracycline-like toxicities were attenuated. Pharmacokinetically, PK1 has a distribution t(1/2) of 1.8 h and an elimination t(1/2) averaging 93 h. 131I-labeled PK1 imaging suggests PK1 is taken up by some tumors. Responses (two partial and two minor responses) were seen in four patients with NSCLC, colorectal cancer, and anthracycline-resistant breast cancer. PK1 demonstrated antitumor activity in refractory cancers, no polymer-related toxicity, and proof of principle that polymer-drug conjugation decreases doxorubicin dose-limiting toxicities. The recommended Phase II dose is 280 mg/m2 every 3 weeks. Studies are planned in colorectal, NSCLC, and breast cancer patients.

Adult↗

Determination of a new polymer-bound paclitaxel derivative (PNU 166945), free paclitaxel and 7-epipaclitaxel in dog plasma and urine by reversed-phase high-performance liquid chromatography with UV detection.

A sensitive and selective high-performance liquid chromatographic method for the determination of PNU 166945, a new polymer-bound paclitaxel derivative, free paclitaxel and 7-epipaclitaxel in dog plasma and urine has been developed. The method involves a solid-phase extraction of free paclitaxel and its possible degradation product 7-epipaclitaxel from plasma and urine, previously buffered with an equal volume of 0.05 M or 1 M KH2PO4 respectively, on 1-ml cyanopropyl columns. Cartridges elution was performed with the mobile phase, 0.05 M (pH 4.6) monobasic potassium phosphate-acetonitrile mixture (45:55, v/v). The samples were chromatographed on a reversed-phase octyl 4-microns column with UV detection at 229 nm. The retention times of paclitaxel and 7-epipaclitaxel were about 14 and 22 min, respectively. Determination of total paclitaxel (free + polymer-bound) was performed after release of paclitaxel from the polymeric carrier by chemical hydrolysis at room temperature (22 degrees C) for 20 h. After addition of 0.5 ml of methanol-0.1 M KH2PO4 mixture (50:50, v/v, pH = 7.5) to 0.5 ml of plasma or urine, paclitaxel was analysed as described above. PNU 166945 concentration was then determined by subtraction of free from total paclitaxel. The linearity, precision, accuracy and recovery of the method were evaluated. The limit of quantitation of the method was 5 ng/ml for biological fluid for paclitaxel and 7-epipaclitaxel and 20 ng/ml for PNU 166945 (as paclitaxel equivalent).

Animals↗

Determination of PNU 153429, a new polysulphonated derivative of distamycin A, in rat plasma by reversed-phase ion-pair high-performance liquid chromatography with ultraviolet detection.

A rapid and selective ion-pair high-performance liquid chromatographic (HPLC) method for the determination of 2,2'-(carbonylbis(imino-N-methyl-4,2-pyrrole carbonylimino (N-methyl-4,2-pyrrole)carbonylimino)) -bis(1,5-naphtalenedisulphonic acid), tetrasodium salt (PNU 153429,I) in rat plasma has been developed. I is a new drug currently under investigation for the treatment of rheumatoid arthritis. Aliquots of 100 microliters of plasma spiked with 10 microliters of internal standard solution (PNU 145156E, I.S.) were added to 100 microliters of acetonitrile and vortex mixed. After centrifugation, diluted aliquots of the supernatant were transferred to autosampler vials and analyzed by reversed-phase ion-pair liquid chromatography under isocratic conditions. The retention times of I.S. and I were approximately equal to 8 and 12 min, respectively. Quantitation was achieved by ultraviolet detection at 323 nm. The assay had a limit of quantitation of 0.1 micrograms ml-1 when 100 microliters of plasma were analyzed. The linearity, precision and accuracy of the method were evaluated. No interference from blank rat, mouse, dog, monkey and human plasma was observed. The suitability of the method for in vivo samples was checked by analysis of plasma samples drawn from three cannulated male rats that had received a single 100 mg kg-1 i.v. dose of the test compound.

Animals↗

Pharmacokinetics of reboxetine enantiomers in the dog.

Reboxetine, (RS)-2-[(RS)-alpha-(2-ethoxyphenoxy)benzyl]morpholine methanesulphonate, is a racemic compound and consists of a mixture of the (R,R)- and (S,S)-enantiomers. The pharmacokinetics of reboxetine enantiomers were determined in a crossover study in three male beagle dogs. Each animal received the following oral treatments, separated by 1-week washout period: 10 mg/kg reboxetine, 5 mg/kg (R,R)- and 5 mg/kg (S,S)-. Plasma and urinary levels of the reboxetine enantiomers were monitored up to 48 h post-dosing using an enantiospecific HPLC method with fluorimetric detection (LOQ: 1.1 ng/ml in plasma and 5 ng/ml in urine for each enantiomer). After reboxetine administration mean tmax was about 1 h for both enantiomers. Cmax and AUC were about 1.5 times higher for the (R,R)- than for the (S,S)-enantiomer, mean values +/- SD being 704 +/- 330 and 427 +/- 175 ng/ml for Cmax and 2,876 +/- 1,354 and 1,998 +/- 848 ng.h/ml for AUC, respectively. No differences between the (R,R)- and (S,S)-enantiomers were observed in t1/2 (3.9 h). Total recovery of the two enantiomers in urine was similar, the Ae (0-48 h) being 1.3 +/- 0.7 and 1.1 +/- 0.7% of the enantiomer dose for the (R,R)- and the (S,S)-enantiomers, respectively. No marked differences in the main plasma pharmacokinetic parameters were found for either enantiomer on administration of the single enantiomers or reboxetine. No chiral inversion was observed after administration of the separate enantiomers, as already observed in humans.

Animals↗