Search PubMed⌕ Search

Biomedical subjects

E David-Neto

Publications and source records attributed to E David-Neto.

24 records · Page 2Linked to original sources

Experimental training model of pancreas transplant.

UNLABELLED: Pancreas transplant (Ptx) is the gold standard for the treatment of type I diabetes, mainly when associated with renal failure. The number of Ptx is increasing worldwide, but in developing countries, such as Brazil, the number of centers is small and transplant surgeons need to practice the technique. METHODS: For this model, 21 pancreas harvestings were performed in patient corpses after death from extra-abdominal causes, without pancreatic disease and peritoneal or systemic infection. The vessels of the grafts were prepared on the backtable according to the usual practice in humans. The pancreas was implanted in the inferior vena cava and aorta of mixed breed dogs, with 10 exocrine-bladder drainage and 11 duodenum-ileal anastomosis. RESULTS: There were anastomotic strictures of the portal vein in dogs 1 and 2. There was no arterial stricture or large bleeding. None of the animals died until the revascularization of the graft. Dogs 2, 5, and 8 died during the exocrine anastomosis. The arterial flow was initially high, but at the end of the procedure there were thromboses of small arteries. CONCLUSION: The experimental surgical technique model is feasible, repeating the stages of clinical pancreatic transplantation and allowing the training of surgeons.

Animals↗

Comparison of the fluorescent polarization (TDx) and the enzymatic competitive (EMIT 2000) immune assays for the measurement of cyclosporin A blood concentration.

Evaluation of Cyclosporin A (CyA) blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx) and the enzymatic competitive immune assay (EMIT 2000). There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, p<0.001). The within-run and between-days coefficient of variation were less than 4% for both assays. The cost for each CyA measurement was 50% lower for the EMIT assay when compared to the TDx assay. We concluded that the EMIT is as accurate as the TDx in measuring CyA blood concentration and has the advantage of a lower cost, as well as the possibility of widespread access to the EMIT methodology in contrast to the TDx equipment, allowing the laboratory to perform several routines within a working day.

Costs and Cost Analysis↗