[Experimental study of the stresses induced by loading in the human femur].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to E Cucciniello.
Explore the source record for details and available documents.
The authors carried out an experimental study to quantify the stability of monolateral fixation devices of the Hoffmann type. The technical tests indicated that changes were needed in the geometry of the devices; these were achieved by designing a junction piece which enables the transfixion pins and the smooth stabilization rod to remain in the same plane, while leaving the rest of the instrumentation unchanged. The use of this component makes the fixation device more stable and lighter than the classic monolateral devices commonly used. It also prevents the separation and rotation of the fragments that can occur when rods not in the same plane are subjected to compression.
The equilibrium between plasma and peritoneal dialysis fluid has been studies for 23 amino acids during peritoneal exchanges at dwell times up to 8 hours in patients on CAPD. It is demonstrated that equilibration is a particular process typical for each amino acid which after 8 hour is nearly complete only for Glycine, Alanine and Asparagine.
The ideal dialysis access ensures adequate blood flow for dialysis, has a long life, and is associated with a low complication rate. Although no current type of access fulfills all these criteria, the native arteriovenous fistula (AVF) is close to doing so. Unfortunately, various kinds of vascular access (VA) are becoming more and more necessary to enable hemodialysis (HD). The central venous catheter (CVC), which is associated with higher morbidity and mortality, could be the only viable option to maintain permanent VA. We report an unusual complication in a patient, a 74-year-old female, who had been undergoing HD via a CVC for 14 yrs. A polyurethane CVC with a double lumen was inserted into the right internal jugular vein because an AVF was not feasible, and a polytetrafluoroethylene (PTFE) prosthesis was obstructed. In 2003, the CVC was removed due to stenosis and occlusion of the superior vena cava. A new CVC, also made of polyurethane and with a double lumen, was inserted into the left femoral vein. In January 2005, the patient reported a small rupture of about 3-4 mm located under the cuff of the CVC. For this reason, the left femoral vein had to be used, replacing the Optiflow one with a 40-cm long Tesio CVC, and the second catheter was inserted into the right femoral artery by conventional surgery. After 10 months, the patient returned once more, after the CVC in the left femoral vein had been removed because of malfunction and that the at-tempts to cannulate the same vein again had failed. Currently, two 70-cm long Tesio catheters implanted in the right femoral vein (whose tips almost reach the diaphragm) are used for dialysis sessions. The number of CVC implants has progressively increased amongst HD patients who are elderly, diabetic or who have been on long-term HD. The patient described in this case report is currently using a 70-cm long double Tesio catheter (single Tesio CVC in SPI silicon) placed in the right femoral vein. She has resumed therapy with dicumarol anticoagulants, maintaining INR within the 2.5-3.5 range. In conclusion, both the increase in the use of venous catheters for HD and in the survival of dialysis patients contribute towards the observation of rare complications associated with CVC use.
Bioelectrical analysis (BIA) is an easy, repeatable, low cost, operator-independent method. BIA obtains two different goals, i.e. body water content evaluation, by the RXc Graph or the BIVA Z score and morbidity and mortality predictions by the phase angle. Therefore, BIA can be considered as part of the clinical examination for the evaluation of both hydration and nutritional status.