Search PubMed⌕ Search

Biomedical subjects

E Corday

Publications and source records attributed to E Corday.

At least 91 records · Page 5Linked to original sources

Evaluation of changes in left ventricular end-diastolic pressure by left atrial two-dimensional echocardiography.

Two-dimensional echocardiography (2DE) measurements of left atrial (LA) cross-sectional areas were compared in closed-chest dogs with concurrent high-fidelity recordings of left ventricular end-diastolic pressure (LVEDP) measurements. One hundred forty-three simultaneous determinations of LVEDP and end-diastolic as well as end-systolic LA cross-sectional areas were obtained in eight dogs during control, after coronary artery occlusion, and following alterations in LV preload and afterload. Correlation coefficients for LVEDP versus LA end-diastolic cross-sectional area ranged from 0.85 to 0.97 in the eight dogs, with standard errors of estimate from 1.89 to 5.43 mm Hg. These findings suggest that 2DE measurements of changes in LA size may facilitate noninvasive evaluation of alterations in LVEDP in patients with LV failure or undergoing interventions.

Animals↗

Hypothermic coronary venous phased retroperfusion: a closed-chest treatment of acute regional myocardial ischemia.

Hypothermic synchronized retroperfusion (HSRP) was applied in closed-chest dogs after acute coronary occlusion to determine whether this intervention can significantly retard the otherwise rapidly developing irreversible ischemic injury. The left anterior descending coronary artery (LAD) was occluded for 3 hours in 22 dogs and for 6 hours in 16 dogs. Starting 30 minutes after occlusion, HSRP was applied during maintained coronary occlusion in 21 dogs. The remaining dogs served as untreated controls. Arterial blood was cooled to 20 degrees C and retroperfused in diastole into the regional coronary veins. Hemodynamics, contrast cineangiography and two-dimensional echocardiography were measured sequentially. Glycogen-depleted ischemic areas and necrotic zones were delineated in transverse slices of the left ventricle. Untreated controls dogs further deteriorated; in contrast, HSRP between 30 minutes and 3- and 6-hour LAD occlusion significantly reduced the rate-pressure product (21.3 +/- 4.0% or 26.8 +/- 8.2%) and left ventricular end-diastolic pressure (39.5 +/- 9.5% or 51.4 +/- 7.7%) and increased ejection fraction (28 +/- 17% and 33 +/- 2.0%). HSRP caused no arrhythmias and led to much less necrosis of ischemic myocardium in the treated 3- or 6-hour occlusion series (7.4 +/- 2.7% or 28.9 +/- 12.6%) than in respective untreated controls (47.1 +/- 8.9% and 72.3 +/- 5.9%). Moderately hypothermic closed-chest phased retroperfusion appears to protect reversibly injured ischemic myocardium and improve cardiac function. Such treatment may be particularly suitable in the earliest stages of evolving myocardial infarction, when maintenance of myocardial viability is essential for preservation of jeopardized myocardium while awaiting coronary bypass revascularization or nonsurgical thrombolytic reperfusion.

Animals↗

Two-dimensional echocardiographic assessment of left ventricular stroke volume: experimental correlation with thermodilution and cineangiography in normal and ischemic states.

Left ventricular stroke volumes derived by two-dimensional echocardiography (2D echo) were compared with thermodilution and cineangiography measurements in closed-chest dogs before andone hour after proximal LAD occlusion. Stroke volume was calculated from end-diastolic and end-systolic volumes reconstructed by two models: 1) Simpson's rule employing left ventricular length and five short-axis cross-sectional areas; 2) a simplified volume formula (V = 5/6 area . length), utilizing a single short-axis area at either the mitral valve or midpapillary muscle level. The comprehensive Simpson reconstruction yielded a good correlation of 2D echo stroke volume against thermodilution (r = 0.89) over a range of normal (N = 14) and ischemic (N = 8) states. The simplified formula provided a satisfactory correlation (r = .90, N = 22) when using the midpapillary cross-section, which encompassed the induced ischemic dys-synergy. In contrast, when using the mitral valve level cross-section above the site of ventricular asymmetry, there was no significant statistical correlation. Comparison of cineangiography with 2D echo volume reconstruction based on the simplified formula with the midpapillary muscle level section yielded good correlations for stroke volume (r = 0.87) and ejection fraction (r = 0.97). Intraobserver and interobserver variability of duplicate echo stroke volume measurements was 8% and 10%, respectively. We conclude that 2D echocardiography in dogs permits quantitation of left ventricular stroke volume in normal and ischemic states.

Animals↗

Early phase acute myocardial infarct size quantification: validation of the triphenyl tetrazolium chloride tissue enzyme staining technique.

Gross histochemical delineation of myocardium which has lost dehydrogenase enzyme activity has been shown to facilitate macroscopic recognition of necrotic myocardium. The present study was undertaken to assess the accuracy of the triphenyl tetrazolium chloride (TTC) technique for quantitating myocardial infarct size very early after coronary occlusion. In 16 closed-chest dogs the left anterior descending coronary artery was occluded with an intra-arterial balloon. Twelve dogs were killed 6 hours after occlusion, their hearts excised, cut from apex to base into 1 cm thick slices, and incubated in TTC. Whole-mount histologic sections of each slice were prepared. Myocardial infarct size was measured by planimetry of photographs of each gross slice and histologic section using classical criteria of necrosis. Myocardial infarct size determined in 54 slices by the TTC technique and histologically was similar (25 +/- 16% vs 27 +/- 16% of the left ventricular mass, mean +/- SD) with close correlation between the two methods (r = 0.91). Four dogs were killed 3 hours after occlusion and TTC stained and unstained myocardium was studied by electron microscopy. When the TTC technique identified necrosis so did electron microscopy. Areas identified by the TTC technique as non-necrotic were either normal or only ischemic by electron microscopy. Thus, using TTC, necrosis can be quantitated reliably 6, and even 3 hours after coronary occlusion, before histologic changes are clearly diagnostic. This technique represents a reliable, practical means for quantitation of recent infarction and for studying the evolution of ischemic injury in its early phase.

Acute Disease↗

Real time computerization of two-dimensional echocardiography.

A computerized system was developed for real time acquisition, enhanced processing, analysis, and display of cross-sectional images of the left ventricle derived by two-dimensional echocardiography (2DE). The new methodology couples a standard medical imaging computer system to the video output of any current 2DE unit, uses a 128 x 128 or 64 x 64 matrix window and stores the real time 30 frames/sec digitized images on a magnetic disk. Computerized beat-to-beat and frame-by-frame processing employs space-time smoothing the automatic detection of endocardial interfaces by standard threshold and second derivative techniques. Multiple views are displayed in real time with 256 levels of gray and color. The methodology was used to analyze and graphically display frame-by-frame changes throughout the cardiac cycle. In addition, regional wall motion and thickness were analyzed in 12 sectors of individual cross-sections using a standardized angular subdivision originating at the center of area and indexed by an external reference point. An algorithm was developed to correct cross-sectional interference definition from the commonly used trailing-to-leading edge to the more valid leading-to-leading outline technique. Computerized analysis of spatial and temporal variations of cardiac contraction were demonstrated in several clinical and experimental applications, including bicycle exercise testing, investigation of acute myocardial infarction, and assessment of interventions. Initial evaluation indicates that the new real time computerized digital acquisition and data analysis represents a major advances toward quantitation of left ventricular function using 2DE.

Animals↗

Characterization of left ventricular mechanical function during arrhythmias with two dimensional echocardiography. I. Premature ventricular contractions.

Two dimensional echocardiography was applied experimentally in the closed chest dog to quantitate left ventricular function during and immediately after single premature ventricular contractions induced through threshold stimulation at the apex. Coupling intervals were varied over a range from 35 to 85 percent of the R-R interval during normal sinus rhythm (920 to 980 ms). The quality of tomographic echocardiographic images during premature as well as postextrasystolic beats was found to be satisfactory for quantitating short axis section areas at end-diastole and end-systole. A systolic fractional area change was computed from two dimensional echocardiographic measurements to characterize mid ventricular cardiac function, which correlated significantly with peak left ventricular pressure and maximal first derivative of left ventricular pressure (dP/dt). Marked shortening of coupling intervals reduced fractional shortening during premature systole and enhanced the degree of potentiation during the postextrasystolic beat. By contrast, premature beats with relatively long coupling intervals caused less reduction in contraction and only minor postextrasystolic potentiation. Systolic shortening of left ventricular length as well as transverse diameters were studied in a two dimensional echocardiographic long axis cross section. During long coupling intervals contraction was normal except for distinct regional systolic outward "bulging" in the apical region. In contrast, short coupling intervals were associated with a more significant generalized derangement of ventricular wall motion during systole. It is concluded that the two dimensional echocardiographic method can be used to portray and quantitate global as well as regional left ventricular function during disturbances of cardiac rhythm.

Animals↗

Quantitative two dimensional echocardiography during bicycle exercise in normal subjects.

A quantitative two dimensional echocardiographic study was conducted in 10 normal subjects performing bicycle exercise in a supine position. Standardized two dimensional echocardiographic short axis and apical views of the left ventricle were analyzed to derive left ventricular sectional areas and length. Over a range of exercise heart rates from 108 to 152 beats/min, satisfactory two dimensional echocardiographic views and measurements were obtained for quantitative assessment of sectional and global left ventricular function. Variability of left ventricular short axis area measurements ranged from 2.9 to 8.3 percent. Left ventricular volume reconstruction employed a simplified formula (volume = 5/6 area X length) with a single papillary muscle level short axis area and left ventricular length. Changes in left ventricular function from rest to exercise quantitated by two dimensional echocardiography indicated a significant reduction in end-systolic volume (from 28.1 +/- 5.6 to 20.8 +/- 4.3 cc/m2, p less than 0.001) and increased left ventricular ejection fraction (from 63.4 +/- 6.3 to 72.1 +/- 5.7 percent, p less than 0.001). The change in end-diastolic volume was not significant. It is concluded that standardized two dimensional echocardiographic study during supine bicycle exercise in normal subjects provides good reproducibility of measurement of sectional and global left ventricular function. Quantitative two dimensional echocardiographic exercise study of global as well as segmental left ventricular performance in patients may be feasible using standardized procedure and analysis.

Adolescent↗

Experimental evaluation of the extent of myocardial dyssynergy and infarct size by two-dimensional echocardiography.

The extent of left ventricular (LV) dyssynergy was assessed noninvasively in 19 dogs with two-dimensional echocardiographic short-axis sections during myocardial ischemia and infarction. After coronary occlusion, two-dimensional echocardiography uniformly indicated an increase in LV end-diastolic volume and a decrease in LV ejection fraction. Two-dimensional echocardiographic measurements of dyssynergy were evaluated and compared in three subgroups against (1) the extent of LV dyssynergy determined by force-gauge mapping during 10 coronary occlusions of 30-60 minutes' duration in eight open-chest dogs, (2) infarct size delineated by nitroblue tetrazolium (NBT) staining of left ventricular slabs after 48 hours of left anterior descending coronary artery (LAD) occlusion in five closed-chest dogs, and (3) NBT infarct size after 3-hour LAD occlusion followed by 45 hours of reperfusion in six closed-chest dogs. Linear regression analysis of results from these three comparisons gave good correlations (r = 0.89) for groups 1 and 2; in group 2, the extent of dyssynergy by two-dimensional echocardiography was consistently greater than infarct size by NBT. In group 3, the correlation was poor (r = 0.39). These results suggest that an adequate estimate for the extent of LV dyssynergy or infarct size may be obtained with two-dimensional echocardiography during myocardial ischemia or infarction, but not in the presence of coronary reflow, which causes an acute discrepancy between myocardial viability and function.

Animals↗

[Quantitative study of left ventricular function by two-dimensional echocardiography].

The results of two dimensional echocardiography and cineventriculography in the calculation of left ventricular volumes and ejection fractions were compared. The study was performed experimentally in dogs and also in 12 patients with ischaemic heart disease. 25 measurements were performed in the animal: 19 basal and 6 measurements one hour after occlusion of the LAD. Reconstruction by Simpson's method showed good correlations with angiography (p less than 0,001) for enddiastolic volume (r = 0,94), end systolic volume (r = 0,97) and ejection fraction (r = 0,89). A preliminary clinical study was performed in 12 patients. All had significant stenosis of at least one main coronary artery and 10 had segmental abnormalities of left ventricular wall motion. Left ventricular volumes were calculated from the simplified 5/6 AL formula which only requires one long axis view and one short axis view at the level of the papillary muscles. The comparison between echocardiography and angiography showed a better correlation for end systolic volume (r = 0,91) than for end diastolic volume (r = 0,73). Echo underestimated end diastolic volume by 14% and end systolic volume by 13%. The correlation obtained for ejection fraction was excellent (r = 0,97) with no underestimation of this parameter by echocardiography. In conclusion, left ventricular volumes and ejection fractions may be calculated by two dimensional echocardiography. The technique allows a sequential quantitative study from beat to beat and in real time of cardiac function. It is a simple non-invasive method of following the evolution of cardiac disease and of assessing the effects of therapy on left ventricular function.

Adult↗

Ventricular aneurysm: cross-sectional echocardiographic approach.

Current angiographic indexes of ventricular function have proved inadequate for prognostication in patients with ventricular aneurysm. Cross-sectional echocardiography can visualize residual myocardium in all four walls of the left ventricle. A new echocardiographic technique of calculating residual myocardium is presented. The echocardiographic technique yielded identical information to that of contrast angiography (r = 0.97). An index of residual myocardium was generated from the cross-sectional echocardiogram that correlated with the clinical state of the patients. In patients treated medically it predicted those patients likely to die within 6 months (p < 0.005). Preliminary observations in patients having aneurysmectomy revealed that there were good surgical results in those with an index of residual myocardium of 0.42 or greater, but more patients are necessary to establish the lower limit of a surgically acceptable level of residual myocardium.

Adult↗

[Cross-sectional echocardiography applied to the study of the effects of sodium nitroprusside on left ventricular function (author's transl)].

Quantitative measurement of the left ventricular function by means of cross-sectional echocardiography is now well established. The present study suggests that the method could be used to record and assess the effects of vasodilators on the performance of an ischaemic left ventricle. Congestive heart failure was induced in 3 dogs by occluding the anterior interventricular artery, and sodium nitroprusside was injected intravenously. Haemodynamic and echocardiographic data were recorded simultaneously. Using two echotomographic sections at a right angle, changes in left ventricular volume and stroke volume were calculated from the equation V = 5/6 AL, where V is the volume, A the surface and L the length of the ventricle. The application of this non-invasive technique to the analysis of global and regional left ventricular function in various clinical situations is discussed.

Animals↗

Cross-sectional echocardiography. III. Analysis of mathematic models for quantifying volume of symmetric and asymmetric left ventricles.

Cross-sectional echocardiography was utilized for quantification of volume in 19 formalin-fixed left ventricles in the presence or absence of ventricular symmetry, defined by the ratio of septal-lateral to anterior-posterior diameter. In 10 symmetric ventricles this ratio was 1.23 +/- 0.06 (mean +/- SEM), whereas in nine asymmetric ventricles the ratio was 1.80 +/- 0.07. Area, diameter, and length measurements were obtained from short- and long-axis cross-sectional images of the left ventricle and volume was calculated by five mathematical models previously described. To evaluate the reliability of each model, echocardiographic left ventricular volume was compared by linear regression and percent error analyses to directly measured fluid volume. In symmetric ventricles, excellent correlations (r = 0.996 to 0.967) and reasonable mean percent errors (6% to 31%) were observed for all models. In asymmetric ventricles, models utilizing short-axis area or two short-axis diameters retained high correlation coefficients (r = 0.985 to 0.956) and similar mean percent errors, but standard formulas previously used with M-mode echo and angiography showed lower correlations (r = 0.886 to 0.873) and higher mean percent errors (52% to 54%). Thus, in the presence of ventricular asymmetry, analysis of short-axis areas or diameters with cross-sectional echocardiography is well suited for quantification of left ventricular volumes.

Cardiac Volume↗

Cross-sectional echocardiography. II. Analysis of mathematic models for quantifying volume of the formalin-fixed left ventricle.

Cross-sectional echocardiography was used to quantify volume in 21 canine left ventricles that were fixed in formalin and immersed in mineral oil. Area, length and diameter measurements were obtained from short- and long-axis cross-sectional images of the left ventricle and volume was calculated by seven mathematic models. Calculated volume was then compared, by linear regression and percent error analyses, with fluid volume of the left ventricle, obtained by filling the chamber with a known amount of fluid. Volumes ranged from 13-146 ml. Mathematic models using short-axis area and long-axis length gave higher correlation coefficients (r = 0.982 and r = 0.969) and lower mean errors (10-20%) than standard formulas previously used for M-mode echo and angiography. Thus, short-axis area analysis with cross-sectional echocardiography is well-suited for quantifying left ventricular volumes in dogs.

Animals↗