Differential effect of amantadine hydrochloride on the systemic and local immune response to influenza A.

Anti-influenza serum and nasal antibody titers were followed during a double-blind, placebo-controlled, randomized study assessing the prophylactic efficacy of 50, 100, and 200 mg/day of amantadine hydrochloride against experimental challenge with influenza A/Beth/1/85. The geometric mean titers (GMT) of serum hemagglutination inhibition antibody (P = .05) as well as serum influenza-specific IgG (P = .004) were significantly lower for all amantadine groups when compared to placebo. There were no significant differences in the GMT of either type of serum antibody titer comparing any of the three amantadine groups. Viral titers were also lower in the amantadine groups compared to the placebo group and not significantly different among the three amantadine groups. Nasal antibody titers in the 100-mg and 200-mg amantadine groups were significantly lower than placebo titers (P = .002). Nasal antibody titers in the 50-mg amantadine group did not differ significantly from titers in the placebo group (P = .892). Possible reasons for the differential effect of amantadine on the serum and nasal antibody response are discussed.

Adolescent↗

Efficacy and safety of low dosage amantadine hydrochloride as prophylaxis for influenza A.

The efficacy and safety of prophylactic low dose amantadine hydrochloride was assessed in two double-blind, placebo-controlled, randomized studies. In a study of 476 subjects aged 18 to 55 years, adverse reactions were not significantly different between the group receiving 100 mg/day amantadine and the placebo group but significantly greater in the group given 200 mg/day (P less than 0.009). The influenza attack rate in this study was too low to assess efficacy. In an experimental challenge study of influenza A/Beth/1/85 in 78 subjects of similar age the prophylactic administration of 50 mg, 100 mg or 200 mg/day doses of amantadine were more effective than placebo in preventing influenza illness (P less than 0.02, 66, 74 and 82% protection, respectively), and in suppressing viral replication (P = 0.02). There was no significant difference between amantadine groups in influenza illness or viral shedding. Compared with the placebo group the 100 and 200 mg amantadine groups showed a significant decrease in infection rate (100 mg: 40% protection: P = 0.012; 200 mg: 32% protection: P = 0.045) whereas the 50 mg group did not (20% protection: P = 0.187). These results suggest that 100 mg/day of amantadine will reduce toxicity but maintain the prophylactic efficacy seen with 200 mg/day.

Adolescent↗

Effects of antibody to rotavirus on protection of adults challenged with a human rotavirus.

Effects of preinoculation rotavirus antibody titers on the probability of infection and illness were evaluated in adults challenged orally with different doses of a virulent human rotavirus (CJN strain). Preinoculation titers considered were serum neutralizing antibody, serum rotavirus IgA, serum rotavirus IgG, jejunal neutralizing antibody, jejunal rotavirus IgA, and stool rotavirus IgA. Doses of virus of either 9 x 10(1) or 9 x 10(3) focus-forming units were administered to 19 subjects each. Twenty-six were infected; 15 experienced illness. The probability of either outcome was unrelated to dose. Stool rotavirus IgA titers could not be correlated to either infection or illness, but the mean titers of the other five antibodies were significantly or nearly significantly lower in subjects infected or ill, when compared with those negative for either outcome. When analyzed by stepwise logistic regression, only serum rotavirus IgG remained significantly (P = .005) related to the probability of infection, and only jejunal neutralizing antibody remained significantly (P = .01) related to the probability of illness.

Adult↗

Ribavirin small-particle-aerosol treatment of influenza B virus infection.

In a randomized double-blind trial of aerosolized ribavirin for the treatment of influenza B virus infection, no significant difference was found in the febrile course or symptom score of the ribavirin-treated versus placebo-treated patients. The apparent lack of efficacy in this study as compared with that in previous studies is unexplained.

Adult↗

An experimental analysis of treatment effects on consonant clusters and ambisyllabic consonants in two adults with developmental phonological problems.

The effect of treatment on errors in consonant clusters and in ambisyllabic consonants were investigated in two adults with histories of developmental phonological problems. Using a multiple baseline across behaviors, ambisyllabic consonant errors were treated in bisyllabic words and consonant cluster errors were treated in two different cluster classes. Results indicated that treatment, consisting of a sound-referenced rebus approach, affected change in production of trained words as well as generalization to untrained words for targeted behaviors.

Adult↗

Human rotavirus studies in volunteers: determination of infectious dose and serological response to infection.

An unpassaged, safety-tested strain (CJN) of human rotavirus from a stool specimen of a hospitalized child was administered orally to 62 adult volunteers for determination of the dose required to produce infection with or without illness. Subjects ingested doses ranging from 9 X 10(-3) to 9 X 10(4) focus-forming units in buffered salt solution after consumption of 50 ml of 4% NaHCO3. The amount of virus in the inoculum required to cause infection (shedding of virus, seroconversion, or both) in study subjects was comparable to the minimum detectable in cultures of primary monkey kidney cells. Seventeen of 30 infected subjects became ill with doses equivalent to that required for infection. Although the preinoculation titers of serum neutralizing antibody to the challenge virus in study subjects ranged from less than 1:2 to 1:1,600, the concentration of serum antibody could not be correlated with protection from infection or illness in subjects given an infectious dose of virus.

Adult↗

Studies of echovirus-12 in volunteers: determination of minimal infectious dose and the effect of previous infection on infectious dose.

A two-part study of echovirus-12 was done in volunteers. In the first part the human infectious dose of the virus was determined in 149 healthy adults with undetectable serum antibody, each of whom drank 0-330,000 plaque-forming units (pfu) of virus in 100 ml of nonchlorinated water. Infection was defined as fecal shedding of virus or significant (fourfold or greater) increases in serum antibody titer. The HID50 (i.e., the dose required for infection of 50% of the volunteers) was 919 pfu. Through statistical analysis of the data by probit transformation, a 1% human-infectious dose of 17 pfu was predicted. These results were used in the second portion of the study to determine the effect of previous infection on the infectious dose. Previously infected volunteers (those with neutralizing serum antibody) were given a dose of echovirus-12 (1,500 pfu) that had been found to infect 60% of persons with undetectable serum antibody. The presence of serum antibody caused no significant change in the percentage of volunteers infected by this dose. Furthermore, the concentration of serum antibody did not affect the rate of infection or the duration of viral shedding. These results indicate that previous infection with echovirus-12 does not provide lasting protection against reinfection.

Adolescent↗

Care of endoscopic instrumentation.

1. Physicians and OR nursing personnel should be familiar with the use of--and recommendations for care and maintenance of--all endoscopes and accessories. Many costly repairs can be significantly reduced or eliminated by mandating attendance at comprehensive inservice programs for all personnel involved in handling and reprocessing. 2. Video photography is becoming an integral part of many endoscopic procedures. The video camera can make the operative case interesting and informative when it works properly. It can make that same procedure a nightmare if the camera or any of the components are not functioning properly. 3. Each instrument should be examined and tested according to the manufacturer's recommendation prior to and following decontamination, disinfection or sterilization, and use. Always refer to the manufacturer's operating and maintenance manuals for specific cleaning, disinfection, and sterilization guidelines.

Endoscopes↗

The scoop on scopes.

Explore the source record for details and available documents.

Endoscopy↗