Search PubMed⌕ Search

Biomedical subjects

E C Williams

Publications and source records attributed to E C Williams.

At least 19 recordsLinked to original sources

Central venous device-related infection and thrombosis in patients treated with moderate dose continuous-infusion interleukin-2.

BACKGROUND: This study was performed to determine the incidence of central venous device-related blood stream infection and thrombosis in patients treated with moderate dose continuous-infusion interleukin-2 (IL-2). METHODS: The records of 160 consecutive patients treated at the University of Wisconsin Hospital and Clinics, between June 1990 and June 1997, with moderate dose continuous-infusion IL-2 (IL-2 [1.5-3.0 x 10(6) U/m(2)/day] Hoffman-LaRoche, Nutley, NJ or IL-2 [4.5 x 10(6) U/m(2)/day] Chiron Corporation, Berkley, CA) were reviewed retrospectively. The majority of patients had metastatic melanoma (78 patients) or renal cell carcinoma (70 patients). All of the patients had a surgically implanted central venous device placed before starting IL-2 therapy; 89% of these were cuffed Hickman catheters. Eighty-four patients received 1 mg of warfarin per day as prophylaxis against device-related thrombosis; none received periinsertion prophylactic antibiotics. RESULTS: Twenty-one patients (13%) developed central venous device-related bloodstream infection (DRBSI) during the study period, a rate of 2 DRBSI per 1000 device-days. DRBSIs were associated with the type of immunotherapy given with IL-2 (P = 0.01) and with thrombosis (odds ratio, 4.1; 95% confidence interval, 1.5-11.4; P = 0.008) but not with patient gender, type of cancer, duration of the central device, or site of device placement. Twenty-six patients (16%) developed central venous device-related thrombosis (DRT) during immunotherapy. Low dose warfarin did not appear to prevent thrombosis. Device-related thrombosis was associated with DRBSI but not with patient gender, type of cancer, type of device, duration or location of device, or concomitant immunotherapy. CONCLUSIONS: Central venous DRBSI and DRT are significant complications that can occur during moderate dose continuous-infusion IL-2 therapy. The risk of DRBSI appears lower than the risk reported with high dose IL-2 therapy by previous investigators. The risk of DRT appears to be higher than the risk reported for patients with similar devices but not given IL-2. Low dose warfarin did not prevent DRT when started after device placement.

Adult↗

Fludarabine and cytarabine as a sequential infusion regimen for treatment of adults with recurrent, refractory or poor prognosis acute leukemia.

We did a retrospective analysis on the safety and efficacy of sequential infusion fludarabine and cytosine arabinoside (ara-C) in treating refractory, recurrent or poor prognosis acute leukemia in adult patients. Forty-five adult patients with acute myelogenous leukemia (AML) or acute lymphoblastic leukemia (ALL) received a total of 68 courses of sequential continuous infusion of fludarabine for 2 days (total dose 71.5 mg/m(2) ) followed by 3 days of ara-C (total dose 7590 mg/m(2) ). Thirty-nine patients had refractory or recurrent disease, and six had other adverse prognostic features. Thirty-six patients had AML, seven had ALL, and two had CML in blastic phase. Complete remission was seen in 20 patients (44%), and partial remission in 5 patients (11%), giving a total response rate of 56%, similar for both AML and ALL. Duration of response to prior therapy did not affect the response rate. All 3 patients with Philadelphia chromosome positive ALL obtained complete remission. Median remission duration was 4.7 months (range 0.6-36.6), and median overall survival was 5.0 months (0.7-40+). Median overall survival was 10.1 months in responders. Pulmonary toxicity was seen in 8 patients, of whom 2 died from adult respiratory distress syndrome. No cardiac toxicity was observed, but 3 patients had transient cerebellar toxicity. Profound myelosuppression was seen in all patients. We conclude that the sequential infusion of fludarabine and ara-C is an effective non-cardiotoxic regimen for adults with refractory, recurrent or poor prognosis acute leukemia, may be particularly useful for resistant Philadelphia chromosome positive ALL, and may warrant further investigation in this subset. Pulmonary rather than neurological toxicity may be a unique side effect of the regimen.

Acute Disease↗

Activity and dosage of alteplase dilution for clearing occlusions of venous-access devices.

The activity and sterility of reconstituted alteplase solution and the effectiveness of an alteplase dose-escalation protocol for the clearance of midline-catheter and central-venous-access device occlusions were studied. Reconstituted alteplase solution was stored at -70, -25, or 2 degrees C at concentrations of 0.5, 1, or 2 mg/mL. Durations of storage in the freezer were 0, 7, and 14 days, and durations of storage in the refrigerator were 0, 48, and 72 hours and 7 and 14 days. Samples were also assayed and cultured without prior freezing after refrigeration at 2 degrees C for 0, 48, and 72 hours and 7, 14, and 28 days. Fifty-eight pediatric and adult patients were enrolled in a separate study in which catheter clearance was initiated with alteplase 0.5 mg, and the dose was escalated to 1 and 2 mg sequentially until the catheter was cleared. The primary endpoint was restoration of catheter patency, and the secondary endpoint was the occurrence of bleeding episodes within 24 hours of alteplase administration. Catheter removal due to failure to restore patency was also documented. The activity and sterility of alteplase were maintained under all conditions studied. Fifty catheters (86.2%) were cleared with alteplase 0.5 mg, 5 (8.6%) after dose escalation to 1 mg, and 1 (1.7%) after escalation to 2 mg. The alteplase solution did not clear the occlusion in 2 catheters (3.4%): 1 had a mechanical obstruction and 1 cleared two hours after the 1-mg dose was deemed a failure. None of the six catheter removals was due to recalcitrant clots. Bleeding observed was not considered to be the result of alteplase administration. For use in clearing occlusions of venous-access devices, alteplase 0.5, 1, and 2 mg/mL retained sufficient fibrinolytic activity when stored for up to 14 days at 2 degrees C (28 days for the 0.5-mg/mL dilution) and when stored for 14 days at -70 or -25 degrees C followed by up to 14 days at 2 degrees C. The dose-escalation protocol was effective.

Adolescent↗

Performance of para-Pak Ultra ECOFIX compared with Para-Pak Ultra formalin/mercuric chloride-based polyvinyl alcohol for concentration and permanent stained smears of stool parasites.

ECOFIX is a mercury and formalin-free fecal preservative that can be used for concentration of stool specimens and preparation of permanently-stained slides. In this study, the standard two-vial ParaPak Ultra system was compared with ECOFIX Ultra for the detection of intestinal parasites. A total of 261 specimens in 92 sets (77 with 3 specimens, 15 with 2 specimens) were collected in ECOFIX, formalin, and low viscosity polyvinyl alcohol (LV-PVA). Concentrations were performed from ECOFIX using Hemo-De and saline and from formalin using ethyl acetate and formalin. To prepare permanently-stained smears, ECOSTAIN (a modification of Wheatley's trichrome stain) was used on ECOFIX material and Wheatley's trichrome stain was used on specimens preserved in PVA. A total of 157 protozoa and helminths were detected; 132 (84.1%) were recovered in formalin/PVA and 129 (82.2%) in ECOFIX. In permanently-stained smears, 139 protozoa were observed, 116 (83.5%) in PVA-preserved material and 117 (84.2%) in ECOFIX. Fecal concentration yielded 111 parasites (103 protozoa and 8 helminths), of which 98 (88.3%) were detected in formalin-fixed stool and 48 (43.2%) in ECOFIX. Significantly fewer ECOFIX-preserved concentrates were positive for Blastocystis hominis (35 versus 15, p-value <0.001) and Endolimax nana (19 versus 2, p-value <0.001). In conclusion, use of the ECOFIX Ultra collection device in combination with ECOSTAIN resulted in largely comparable recovery of enteric parasites to the conventional two-vial ParaPak Ultra system when both sedimentation-concentration and permanently stained smears were performed, and 2-3 specimens per patient were evaluated.

Feces↗

Performance of three enzyme immunoassays and two direct fluorescence assays for detection of Giardia lamblia in stool specimens preserved in ECOFIX.

ECOFIX is a single-vial stool preservative that is both formalin- and mercury-free. We evaluated the abilities of three commercial Giardia lamblia-specific enzyme immunoassays (EIAs) (ProSpecT Giardia Microplate Assay [Alexon-Trend Inc.], Giardia Test [Techlab], and Premier Giardia lamblia [Meridian Diagnostics, Inc.]) and two commercial direct fluorescent-antibody (FA) assays for G. lamblia (Crypto/Giardia IF Test [Techlab] and Merifluor Cryptosporidium/Giardia [Meridian Diagnostics, Inc.]) to detect G. lamblia in 34 G. lamblia-positive and 44 G. lamblia-negative stool specimens (determined by traditional examination for ova and parasites) preserved in ECOFIX compared to their abilities to detect G. lamblia in the same specimens preserved in formalin as the "gold standard" for each assay. Of the 34 formalin-fixed positive specimens, the number detected by each assay was as follows:, Alexon EIA, 34; Meridian EIA, 27; Techlab EIA, 29; Meridian FA assay, 31; and Techlab FA assay, 28. Both FA tests and the Alexon EIA performed well with ECOFIX, but the other two EIAs detected fewer positive specimens (the difference was statistically significant with the Techlab EIA) when ECOFIX was the preservative. Use of G. lamblia cyst antigen from cultured organisms preserved in formalin and ECOFIX demonstrated that the Alexon EIA could detect smaller amounts of antigen in ECOFIX than the other two EIAs could and suggested that cyst antigen is more stable in formalin. We recommend that laboratories use an FA assay or the Alexon EIA if they plan to use ECOFIX as their stool preservative.

Animals↗

Evaluation of two rapid assays for detection of Clostridium difficile toxin A in stool specimens.

Rapid laboratory diagnosis of Clostridium difficile-associated diarrhea (CDAD) is highly desirable in the setting of hospital cost containment. We tested 654 stool specimens to compare the performance of two assays for rapid detection of toxin A, the Immunocard Toxin A test (Meridian Diagnostics, Inc.) and the Culturette Brand Toxin CD enzyme immunoassay (EIA) (Becton Dickinson Microbiology Systems), with a cytotoxin assay (Cytotoxi Test; Advanced Clinical Diagnostics) and culture on cycloserine-cefoxitin-fructose agar followed by determination of the production of toxins A and B. A chart review was performed for patients whose stool specimens provided positive results on one to three of the assays. With the "gold standard" of all four assays positive or chart review evidence of CDAD, 97 (14.8%) stool specimens were positive by one or more assays and 557 (85.2%) were negative by all methods. Total agreement for all assays was 90.5% (592 of 654). The sensitivity, specificity, positive predictive value, and negative predictive value for toxigenic culture were 94.7, 98.6, 87.1, and 99.5%, respectively, for toxigenic culture; 87.7, 98.6, 86.2, and 98.8%, respectively, for the cytotoxin assay; 71.9, 99.3, 91.1, and 97.3%, respectively, for the Immunocard; and 68.4, 99.1, 88.6, and 96.9%, respectively, for the Culturette EIA. While easy to perform and highly specific, these rapid assays do not appear to be sufficient for accurate diagnosis of CDAD.

Bacterial Toxins↗

Coagulation parameters of ABO group-specific cryosupernatant.

Patients with thrombotic thrombocytopenic purpura that is refractory to conventional fresh frozen plasma (FFP) exchange therapy are sometimes switched to cryosupernatant as the replacement fluid, although its hemostatic properties are not well defined. We performed several key coagulation assays on three pools of four units from each of three ABO groups of cryosupernatant and FFP. Fibrinogen, factor VIII activity, and von Willebrand factor antigen (vWF:Ag) levels were all significantly lower in cryosupernatant compared with FFP, although at levels usually not considered clinically significant. We confirmed that group O FFP contained significantly less factor VIII activity and vWF:Ag compared with groups AB and B. In contrast to FFP, group AB cryosupernatant contained lower levels of fibrinogen, factor V activity, factor VIII activity, and vWF:Ag than groups O or B. Group AB cryosupernatant, with the lowest levels of vWF:Ag and universal ABO compatibility, may be the product of choice for refractory thrombotic thrombocytopenic purpura.

ABO Blood-Group System↗

Activated protein C resistance assay performance: improvement by sample dilution with factor V-deficient plasma.

OBJECTIVE: To evaluate a modification of a commercially available reagent kit (COATEST APC Resistance Kit) for functional activated protein C (APC) resistance testing, and to determine the ability of the modified assay to demonstrate APC resistance in patients receiving warfarin. DESIGN: Functional APC resistance testing was performed using both the first-generation COATEST APC Resistance Kit and a modified, or second-generation, version of the COATEST assay that uses predilution of the patient sample with factor V-deficient plasma. Factor V genotyping for APC resistance (FV R506Q) was performed using a well-characterized polymerase chain reaction-restriction fragment length polymorphism method. SETTING: University medical center. PATIENTS: Seventy-three individuals referred for hypercoagulability testing who were not receiving warfarin therapy and 29 patients with a history of venous thrombosis who were receiving warfarin therapy. MAIN OUTCOME MEASURE: Sensitivity and specificity as determined by comparing functional APC resistance to the FV R506Q genotype. RESULTS: In 73 patients referred for hypercoagulability testing, but not receiving warfarin therapy, a sensitivity of 0.86 and a specificity of 0.75 were obtained with the first-generation COATEST assay. In contrast, a sensitivity and specificity of 1.0 were obtained when the second-generation COATEST assay was employed. In 29 patients receiving warfarin, the first-generation assay exhibited a sensitivity and specificity of 0.88 and 0.95, respectively, whereas the sensitivity and specificity for the second-generation assay was 1.0. CONCLUSIONS: Predilution of patient plasma with factor V-deficient plasma results in improved sensitivity and specificity of the COATEST APC Resistance Kit, thus offering a simple modification to enhance APC resistance determination in the routine clinical laboratory setting.

Blood Coagulation Disorders↗

Use of cycloserine-cefoxitin-fructose agar and L-proline-aminopeptidase (PRO Discs) in the rapid identification of Clostridium difficile.

The PRO Disc (Carr-Scarborough Microbiologicals, Inc., Decatur, Ga.) can be used to screen for L-proline-aminopeptidase produced by Clostridium difficile grown on cycloserine-cefoxitin-fructose agar (CCFA). Fifty stored isolates of C. difficile (48 toxin-positive and 2 toxin-negative isolates) and 47 fresh C. difficile isolates (39 toxin-positive and 8 toxin-negative isolates) were all PRO Disc positive. Other Clostridium species that were PRO Disc positive could be differentiated from C. difficile by failure to grow on CCFA, different colonial morphology on CCFA, or morphology upon Gram staining.

Agar↗

The discovery of a novel R-phycoerythrin from an antarctic red alga.

A novel biliprotein, named R-phycoerythrin IV, has been discovered. It absorbs blue light better than any other known red algal biliprotein. The protein was found in Phyllophora antarctica, a benthic macroalga, which grows beneath the coastal waters of McMurdo Sound, Antarctica. Fluorescence emission and fluorescence excitation polarization spectroscopy demonstrated that R-phycoerythrin IV behaved as a typical R-phycoerythrin in the functioning of energy migration and has an emission maximum at 577 nm. The circular dichroism (CD) spectrum of the chromophores was compared with visible absorption spectrum, and both were deconvoluted. This process showed the energy states of various individual chromophores. The molecular weight of the protein suggested a alpha6beta6gamma polypeptide structure, and far UV CD studies revealed polypeptides with highly alpha-helical secondary structures. Dynamic light scattering indicated that the protein had a 5.54 nm radius, and its shape was nonspherical. R-phycoerythrin was also purified from a second benthic Antarctic red alga, Iridaea cordata. Its spectroscopic properties were similar to those of some R-phycoerythrins from nonpolar regions. The unique spectroscopic properties of R-phycocerythrin IV may help enable the alga to occupy its niche deeper in the water column than the red alga that has the typical R-phycoerythrin.

Antarctic Regions↗

Evaluation of two commercial microtiter cytotoxin assays for the detection of Clostridium difficile toxin B in stool specimens.

Two commercial microtiter cytotoxin assays using a fibroblast cell line (Bartels, Baxter Diagnostics, Inc., Deerfield, IL) and an epithelial cell line (Cytotoxi Test, Advanced Clinical Diagnostics, Toledo, OH) were evaluated for their ability to detect Clostridium difficile toxin B in stool specimens. After 48 hours, the assays had comparable sensitivity (90 versus 92%) and specificity (99 versus 98%). Although not statistically significant, the Bartels assay detected more toxin-positive specimens at 24 hours (84 versus 72%, P = 0.089, Fisher's Exact Test) and the Cytotoxi assay had fewer nonspecific reactions requiring repeat testing (2.2 versus 1.1%, P = 0.186, Fisher's Exact Test). Both cytotoxin assays had comparable analytic performance.

Biological Assay↗

Assessment of vitamin K status in human subjects administered "minidose" warfarin.

Vitamin K is required to convert specific glutamyl residues in a limited number of proteins to gamma-carboxyglutamyl residues. The response of various measures of vitamin K insufficiency to the administration of 1 mg/d of the vitamin K antagonist warfarin was studied in two groups of nine older (55-75 y) or younger (20-28 y) subjects. The most consistent and extensive alteration was an increase in the concentration of serum under-gamma-carboxylated osteocalcin followed by increased immunochemical detection of plasma under-gamma-carboxylated prothrombin (PIVKA-II), and by a decreased urinary excretion of gamma-carboxyglutamic acid. Plasma concentrations of prothrombin were altered by this treatment but prothrombin times, factor VII activity, prothrombin F-1 x 2 concentrations, and a less sensitive assay for under-gamma-carboxylated prothrombine were not. The concentration of serum under-gamma-carboxylated osteocalcin was lower when subjects consumed 1 mg vitamin K/d than when they consumed their normal diet.

1-Carboxyglutamic Acid↗

Factor V R506Q gene mutation analysis by PCR-RFLP: optimization, comparison with functional testing for resistance to activated protein C, and establishment of cell line controls.

Resistance to activated protein C (APC) has been recently identified as a highly prevalent risk factor for the development of venous thrombosis. In the majority of cases, APC resistance correlates with the presence of a single point mutation in the factor V gene (FV R506Q). The mutation is present in 3% to 5% of the general population and in up to 50% of patients with a personal and family history of venous thrombosis. In the current study, the authors have optimized and implemented for clinical diagnosis a method for detection of FV R506Q using the polymerase chain reaction coupled with restriction fragment length polymorphism analysis (PCR-RFLP). Forty-one healthy adults and 139 patients referred for hypercoagulability testing were genotyped and their APC resistance ratios determined using commercially available reagents (COATEST APC Resistance Kit). Comparative analysis indicated that if functional APC resistance was defined as per manufacturer's guidelines, a significant number of individuals with a normal factor V genotype were categorized as APC resistant and conversely, a significant number of individuals heterozygous for FV R506Q were categorized as non-APC resistant. These results indicate that comparative functional and genotypic analyses in the individual clinical laboratory setting are critical for establishing normal ranges and cut-off values for functional APC resistance due to FV R506Q. To facilitate molecular evaluation of APC resistance, Epstein-Barr virus (EBV) immortalized B-lymphocyte cell lines were established from individuals heterozygous and homozygous for FV R506Q.

Adult↗

Cerebral venous thrombosis and activated protein C resistance.

BACKGROUND: Activated protein C resistance (APC-R) due to factor V Leiden has recently been established as an important risk factor for cerebral venous thrombosis (CVT). The clinical significance of abnormal or borderline functional APC-R in the absence of factor V Leiden is uncertain. Our observations suggest that APC-R due to mechanisms other than factor V Leiden may also contribute to the development of CVT. CASE DESCRIPTIONS: We describe three women who had superior sagittal and lateral sinus thrombosis while taking oral contraceptives and had a number of additional risk factors for CVT. Each had APC-R for different reasons. CONCLUSIONS: Inherited thrombophilia, including APC-R, should be looked for in all patients with CVT. Functional APC-R is a highly prevalent coagulopathy, but the reasons for this abnormality are diverse; abnormal and borderline functional APC-R results should be supplemented by DNA analysis for the presence of factor V Leiden.

Adult↗

PCR amplification of rRNA intergenic spacer regions as a method for epidemiologic typing of Clostridium difficile.

From January to March 1993, a suspected outbreak of antibiotic-associated diarrhea occurred on a pediatric oncology ward of the Clinical Center Hospital at the National Institutes of Health. Isolates of Clostridium difficile obtained from six patients implicated in this outbreak were typed by both PCR amplification of rRNA intergenic spacer regions (PCR ribotyping) and restriction endonuclease analysis of genomic DNA. Comparable results were obtained with both methods; five of the six patients were infected with the same strain of C. difficile. Subsequent analysis of 102 C. difficile isolates obtained from symptomatic patients throughout the Clinical Center revealed the existence of 41 distinct and reproducible PCR ribotypes. These data suggest that PCR ribotyping provides a discriminatory, reproducible, and simple alternative to conventional molecular approaches for typing strains of C. difficile.

Bacterial Typing Techniques↗

Profile of young people's advice clinic in reproductive health, 1988-93.

For an unprepared sexually active teenager the 1990s present a minefield of potential problems in addition to the most obvious problems of unplanned pregnancy and sexually transmitted disease. Promoting the importance of a healthy sexual and reproductive life to young people requires openness, better sex education, realistic discussion of related issues, and provision of contraception, as well as support if things go wrong. The Woodhouse Park Clinic in south Manchester opened in October 1988 with the aim of providing weekly advice sessions to young people up to the age of 18. Advice is given on topics such as substance misuse and smoking as well as on family planning. Attendance has steadily increased over the years; from April to June 1993 the average number of attenders per session was 39, one third of whom were young men.

Adolescent↗

Chromophore topography and exciton splitting in phycocyanin 645.

The biliprotein phycocyanin 645 has been purified from a photosynthetic cryptomonad Chroomonas species. It is composed of two copies each of two polypeptides (alpha and beta); each alpha polypeptide has one chromophore, and each beta polypeptide has three. There are one cryptoviolin and two phycocyanobilins on each beta polypeptide and one 697-nm bilin on each alpha polypeptide for a total of eight chromophores on the protein. Circular dichroism (CD) spectroscopy has been used to investigate the arrangement of these chromophores. Comparisons among the intact protein (alpha 2 beta 2) and various urea-treated products have yielded a tentative model for chromophore topography. The six chromophores on the two beta polypeptides are segregated into three pairs. The chromophores of each pair are close enough to experience electronic interactions. One pair, consisting of the two cryptoviolins, produces exciton splitting on the blue edge of the visible CD spectrum, and the two pairs of phycocyanobilins cause exciton splitting on the red edge of this spectrum. Deconvolution shows that the CD spectrum of each pair has a positive and a negative band, which are nearly conservative as expected for exciton coupling. The two chromophores on the alpha polypeptides are more isolated. The pairing of cryptoviolin chromophores occurs across two beta polypeptides, but the more likely position of each of the two pairs of phycocyanobilins is probably not across a beta-beta interface but within a single beta polypeptide. The exciton splitting events both increase the range of visible light absorption for the protein and establish the routes of exciton migration through the protein.

Circular Dichroism↗

Coronary arteriographic findings in black patients and risk markers for coronary artery disease.

Coronary arteriographic results are reported in 1535 black patients: 751 men (mean age 57 +/- 11) and 784 women (mean age 59 +/- 11). Among the black men 19%, 15%, 21%, and 4% had single-, double-, and triple-vessel and left main disease, respectively. Among the black women there were 12%, 10%, 15%, and 3% with similar involvement. Logistic regression models showed that most of the recognized risk factors were positively correlated with significant (at least one artery with > or = 50% stenosis) coronary disease, but a history of hypertension was not a significant independent predictor in either sex. ECG evidence of previous infarction increased the odds of detecting significant coronary disease by the greatest amount when controlling for other significant risk markers in women. In men both previous infarction and atypical pain (negative) were equally important. This study confirms but does not explain previous reports that have revealed less than expected angiographic evidence of significant coronary artery disease in black compared with white persons.

Analysis of Variance↗